Thứ Sáu, 27 tháng 8, 2021

Aube Technologies TH113 F, homeappliance





Download!

GFCI Test and Warning Light On/StandBy Switch Thank you for choosing Aube's TH113-R Regulator. The TH113-R is specially designed to control a floor heating installation, a baseboard or a convector. The TH113-R regulator operates like a dimmer switch to allow you to easily adjust the amount of power sent to your heating system. It features an integrated GFCI, and includes a test button and warning light for added security. This regulator is also equipped with an ON/STANDBY switch making it possible to put it in sleep mode when its use is not required (e.g. summer). Align the bracket tabs on the regulator with the holes located on the power base. Control Module The TH113-R regulator operates on perpetual 15-minute heating cycles. For example, if the dial is set halfway, the system will heat for 50% of the cycle; it will be ON for 7.5 minutes and OFF for 7.5 minutes. Below is a detailed table of the cycle duration based on the dial's position: IMPORTANT! The GFCI and Remote Input options are not available Position and equivalent % I 0% 2 20% 4 40% 6 60% 8 80% 10 100% with a low voltage power base. Skip sections 3 and 4. Power Selection Dial Power Base This regulator must be installed on a PB112 power base. The screw cannot be removed completely. Keep the regulator's air vents clean and free from obstructions. ON 0 min 3 min 6 min 9 min 12 min 15 min OFF 15 min 12 min 9 min 6 min 3 min 0 min NOTE: Depending on the power base used, the heating cycles can be 15 seconds or 15 minutes. ! "# $ % & ' ( ! ) ' Model: TH113-R If you have any questions concerning the TH113-R The GFCI monitors the electrical flow for any loss of current; if there is any loss, the thermostat will cut off power to the heating system. We recommend you test the GFCI immediately after installing the control module, and once a month thereafter to ensure it is operating properly. To test: ■ Press the TEST button: • Successful: TEST warning light is ON and power to heating system is cut off. • Unsuccessful: TEST warning light is OFF. Cut power to heating system from the main power panel and call customer service. □ When successful, reset thermostat (STANDBY/ON) to power heating system. NOTE: If the test warning light comes ON during normal operation, cut power to heating system from the main power panel and have an electrician verify the installation. When a remote control interface (Aube CT241 or any other remote control system) is connected to the power base's remote input and a signal is received, the TH113-R module automatically lowers the percentage by 35% based on the dial's current position. The LED lights up to indicate the signal's presence (except for GA and GB models). The TEST button can be used to bypass the signal for a 2-hour period. The LED goes off to indicate the bypass. NOTE: When combined with a GA or GB power base, the TEST button is used only for GFCI testing. The percentage is decreased, but the bypass function and indicator are not available. Power setting range: 0 to 100% Storage: -20°C to 50°C (-4°F to 120°F) AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address: Aube Technologies Inc. 705 Montrichard Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8 Regulator, call our technical support team at: Phone: Montreal area: (450) 358-4600 Canada / U.S.: 1-800-831-AUBE (2823) Fax: (450) 358-4650 Email: service@aubetech.com Monday to Friday from 8:30 AM to 5:00 PM EST. For more information on our products, visit us at: www.aubetech.com 05/11/03 400-113-004-A ■ Applications 1. The PB112-024T-15S power base can be used on any TH11x series thermostat (with the exception of the TH110 model). This low-voltage power base operates on 15-second cycles and can be connected to a line-voltage load using a solid-state relay. The PB112-024T-15S is compatible with most solid-state relays; however, the following Aube relays are optimized for use with this power base: • RT850 solid-state relay (SSR) • RT850T solid-state relay (SSR) with built-in 24-V transformer WARNING This power base MUST be used ONLY with solid-state relays. The use of electromechanical relays will result in reduced life expect ancy and in the possibility of overheating of these devices. PB112-024T-15S Installation Instructions 24 V Low-Voltage Power Base ⬧ Install the control module onto the base. ⧫ Apply power to the heating system. ◆ Verify the installation by checking that the heating system can be turned on or off using the thermostat. 4.1 Single SSR with Built-in Transformer Electrical Panel Heater Blue Red Black □ Supplied Parts 2. ■ One (1) power base □ Two (2) plastic anchors 🞐 Two (2) mounting screws 🞐 Installation Guidelines 3. 4.2 Multiple SSRs with External Transformer Electrical Panel Black External 24 V Transformer For a new installation, choose a location about 1.5 m (5 ft.) above the floor. The thermostat must be installed on an inside wall facing the heating system (except for floor heating systems). Avoid locations where there are air drafts (top of staircase, air Heater Heater Red Black Red outlet), dead air spots (behind a door), direct sunlight or concealed chimney or stove pipes (except for floor heating systems). ❑ Installation Procedure 4. The installation must be carried out by an electrician and com ply with local electrical codes. ■ Turn off power to the heating system at the main electrical panel to avoid electrical shock. □ Wire the base according to your application. See typical wiring diagrams in sections 4.1 and 4.2. 🞐 For a floor heating system installation, con nect the floor sensor between the S and R ter minals. ❑ Secure the base to the wall using the provided screws and wall anchors. ❒ Configure the switches located on the control module (if any). Refer to the user guide. ❒ Technical Specifications 5. Maximum load: 0.5 A / 24 VAC Heating cycle length: 15 seconds Operating temperature: 32°F to 122°F (0°C to 50°C) Storage: -4°F to 122°F (-20°C to 50°C) Size (H • W • D): 124 x 70 x 23 mm (4.89 x 2.76 x 0.91 in) Wire gauge: 14 to 22 AWG PB112-024T-15S 400-112-024-A 18/1/06 1/1

Không có nhận xét nào:

Đăng nhận xét

Black & Decker Black&Decker Vacuum NV4820CN, homeappliance

Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...