Thứ Sáu, 27 tháng 8, 2021
Aube Technologies TH113-R, homeappliance
Download!
! ' " Aube's TH114 Series non-programmable thermostats can be used to control ambient or floor temperature. The following models are available: A model: controls and displays the ambient temperature F model: controls and displays the floor temperature uses an external temperature sensor AF model: controls and displays the ambient temperature maintains the floor temperature within desired limits uses an external temperature sensor GFCI fault light * Actual or setpoint Arrow appears temperature when the setpoint ■ Refer to the installation instructions of the power base. □ Insert the tabs at the top of the control module in the slots at the top of the power base. 🞐 Secure the control module using the cap tive screw underneath the base. Note: Do not obstruct the thermostat's vents. # $ As soon as the thermostat is powered, it undergoes a series of tests before displaying the actual tempera ture. ( ) is displayed Power output 1 to 24% 25 to 49% 50 to 74% 75 to 99% 100% GFCI fault indicator * Temperature adjustment button GFCI test button * / Backlight button * The measured temperature is below 0°C (32°F). Heat ing is turned On. The measured temperature is above 50°C (122°F) (A or AF model) or 60°C (140°F) (F model). The floor sensor is defective or not properly connected (F model only), or the thermostat is defective. On/Standby button * available on certain models only * +%" Note: This procedure must be performed if the thermostat is Each thermostat consists of a control module which must be mounted on a PB112 Series power base. For the selection and installation of the power base, refer to its installation instructions. "# $ ! % & The DIP switches are located at the back of the control module. To switch between °C and °F. Note: Available on certain models only F: To select the F model AF: To select the A or AF model mounted on a GFCI-equipped power base. Test the GFCI immediately after installing the control module, and once a month there after. ■ Raise the temperature until the heat ing power indicator appears. □ Press the Test button. 🞐 If the test is successful, you will hear a click caused by the GFCI relay tripping. The heating power indicator will disap pear, GFI will appear and the Fault light will illuminate. Reset the thermostat by switching it to Standby and back to On. ❑ If the test has failed, cut power to the heating system from the main electrical panel and call customer service. Note: If the Fault light is On during normal operation, cut power to heating system at the main electrical panel and have an electrician verify the installation. TH114 400-114-000-B 21/2/05 1/2 , 1 , - !. When either of the buttons is pressed, the display is lit for 10 seconds. The setpoint appears for 5 seconds, then the actual tem perature is displayed. When the backlight button is pressed, the display is lit for 5 sec onds. NOTE: If the thermostat is mounted on a GFCI-equipped power base, this button is used for the GFCI test. , The thermostat normally displays the actual temperature. To view the setpoint, press once on one of the buttons. The setpoint is displayed for 5 seconds. During the setpoint display, press one of the buttons to change it. To scroll the setpoint faster, press and hold the button. , ' + / 0+ The thermostat generally turns heating On or Off to con trol the ambient temperature. However, if the floor tem perature drops below the set minimum floor temperature limit or rises above the maximum limit, the thermostat will turn heating On or Off respectively, regardless of the 2 ! ! ! & ! Power supply: Refer to the power base installation instructions. Ambient setpoint range (A/AF models): 5°C to 30°C (40°F - 86°F) Floor limit range (AF model): 5°C to 40°C (40°F - 104°F) Floor setpoint range (F model): 5°C to 40°C (40°F - 104°F) Setpoint resolution: ± 0.5°C (1.0°F) Display resolution: ± 0.5°C (1.0°F) Duty cycle: Refer to the power base installation instructions. Storage: -20°C to 50°C (-4°F - 120°F) 3 4 AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installa tion. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commit ment. ambient temperature, to maintain the floor temperature within the desired limits. The minimum and maximum floor temperature limits are AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the factory-set at 10°C (50°F) and 28°C (82°F) respectively. To modify the limits, proceed as follows: ■ Switch the thermostat to Standby. □ While pressing any button, switch the thermostat back to On to access the floor temperature limit settings. 🞐 Press the Test button briefly to switch between minimum and maximum floor temperature settings. ❑ Press the buttons to set the desired limit. ❒ Press the Test button for 3 seconds to save your modifications. After the data are saved, the thermostat displays the actual ambient temperature or "– –". Note: Your modifications are also saved if no button is pressed for 60 seconds. ⬧ Switch the thermostat to Standby and back to On to reset the GFCI and return to the normal display. : place of purchase or mailed, prepaid and insured, to the following address. 5 6 ! 705 Montrichard Saint-Jean-sur-Richelieu, Quebec J2X 5K8 Canada T: (450) 358-4600 1-800-831-AUBE (2823) F: (450) 358-4650 service@aubetech.com For more information on our products, visit us at: www.aubetech.com TH114 400-114-000-B 21/2/05 2/2 ■ Applications 1. The PB112-024T-15S power base can be used on any TH11x series thermostat (with the exception of the TH110 model). This low-voltage power base operates on 15-second cycles and can be connected to a line-voltage load using a solid-state relay. The PB112-024T-15S is compatible with most solid-state relays; however, the following Aube relays are optimized for use with this power base: • RT850 solid-state relay (SSR) • RT850T solid-state relay (SSR) with built-in 24-V transformer WARNING This power base MUST be used ONLY with solid-state relays. The use of electromechanical relays will result in reduced life expect ancy and in the possibility of overheating of these devices. PB112-024T-15S Installation Instructions 24 V Low-Voltage Power Base ⬧ Install the control module onto the base. ⧫ Apply power to the heating system. ◆ Verify the installation by checking that the heating system can be turned on or off using the thermostat. 4.1 Single SSR with Built-in Transformer Electrical Panel Heater Blue Red Black □ Supplied Parts 2. ■ One (1) power base □ Two (2) plastic anchors 🞐 Two (2) mounting screws 🞐 Installation Guidelines 3. 4.2 Multiple SSRs with External Transformer Electrical Panel Black External 24 V Transformer For a new installation, choose a location about 1.5 m (5 ft.) above the floor. The thermostat must be installed on an inside wall facing the heating system (except for floor heating systems). Avoid locations where there are air drafts (top of staircase, air Heater Heater Red Black Red outlet), dead air spots (behind a door), direct sunlight or concealed chimney or stove pipes (except for floor heating systems). ❑ Installation Procedure 4. The installation must be carried out by an electrician and com ply with local electrical codes. ■ Turn off power to the heating system at the main electrical panel to avoid electrical shock. □ Wire the base according to your application. See typical wiring diagrams in sections 4.1 and 4.2. 🞐 For a floor heating system installation, con nect the floor sensor between the S and R ter minals. ❑ Secure the base to the wall using the provided screws and wall anchors. ❒ Configure the switches located on the control module (if any). Refer to the user guide. ❒ Technical Specifications 5. Maximum load: 0.5 A / 24 VAC Heating cycle length: 15 seconds Operating temperature: 32°F to 122°F (0°C to 50°C) Storage: -4°F to 122°F (-20°C to 50°C) Size (H • W • D): 124 x 70 x 23 mm (4.89 x 2.76 x 0.91 in) Wire gauge: 14 to 22 AWG PB112-024T-15S 400-112-024-A 18/1/06 1/1
Đăng ký:
Đăng Nhận xét (Atom)
Black & Decker Black&Decker Vacuum NV4820CN, homeappliance
Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...
-
Download! BCM7255CN06EFM3.qxd 8/24/06 09:44 Page 1 Digital COOL MIST Humidifier MODEL BCM7255-CN HUMIDIFIER SAFETY PLEASE READ AN...
-
Download! BEFORE AFTER MODEL TH110A-DP-P B 240 VAC B B SUMMARY 60 HZ OPTIONS SELECTION B At the back of the thermostat...
-
Download! KV Push Owner's Manual BILLY GOAT KV VACUUM Owner's Manual KV600, KV650H, KV600FB, KV650HFB Accessories ON B...
Không có nhận xét nào:
Đăng nhận xét