Download!
BCM5555-CN06EFM1.qxd 7/3/06 15:50 Page 1Digital COOL MIST HUMIDIFIER SAFETY PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS 11.DO NOT use outdoors. 12.Always place humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended for use under the humidifier. NEVER place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture. PLEASE SAVE THESE INSTRUCTIONS CONSUMER SAFETY INFORMATION THIS PRODUCT IS EQUIPPED 2. After filling the water reservoir, replace the water reservoir cap by firmly turning clockwise and then replace the water reservoir onto the base. The water reservoir will immediately begin to empty into the base. OPERATING INSTRUCTIONS If you do not plan to use the humidifier for two or more days, make sure any residual water is drained from the water reservoir, base and wick filters to prevent algae or bacteria growth. EXTENDED RUN TIME SETTING REMOTE INSTRUCTIONS 1. Insert 2 AAA batteries into back of remote control. 2. Press the Mode button on remote to begin operation. 3. Use the remote to control the Fig 3 CLEANING AND MAINTENANCE INSTRUCTIONS Humidifiers provide comfort by adding moisture to dry, heated indoor air. To get the most benefit from the humidifier and avoid product misuse, follow all instructions carefully, specifically the operation, care and maintenance guidelines. Please note that this is an Humidifier IMPORTANT SAFEGUARDS 13.DO NOT allow the Moisture Outlet to directly face the wall. Moisture could cause damage, particularly to wall WITH A POLARIZED PLUG (a plug having one blade wider Your humidifier is equipped with a technologically Fig 1 Filter Monitor Control Panel By setting your humidifier to a specific humidity level, you are actually also extending the run time. Since the unit same features as the base unit. NOTE: The timer function can only electrical appliance, and requires attention when in use. In addition, if you do not follow the recommended care MODEL BCM5555-CN When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. Read all instructions before using the appliance. 2. To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet. 3. Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs or near heat registers. paper. 14.Humidifier should be unplugged when not in use. 15.NEVER tilt, move, or attempt to empty unit while it is operating. Shut off and unplug before removing the water tank and moving the unit. If you have a warm mist humidifier, DO NOT attempt to remove the water tank within 15 minutes after the humidifier is turned off and unplugged. Serious injury may result. 16.This humidifier requires daily and weekly maintenance to operate appropriately. Refer to daily and weekly than the other). This plug will fit into the power outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact qualified personnel to install the proper outlet. DO NOT DEFEAT THE SAFETY PURPOSE OF THIS POLARIZED PLUG IN ANY WAY The length of cord used on this appliance was selected advanced Digital Humidistat. You can set the humidifier to run continuously in manual mode or set the Digital Humidistat to your desired humidity setting. The Digital Humidistat will automatically turn the humidifier ON or OFF, depending on the preset comfort level. The Reservoir Handle Water Reservoir Housing Wick Holder will turn on and off to maintain the set humidity level, less water will be used, so you will need to fill the unit less than you would on manual setting. USING THE PROGRAMMABLE TIMER The Digital Humidistat allows the user to program the humidifier to come on at a preset time, or turn off after a set amount of time. Setting the Off Timer: be activated on the base unit. It cannot be activated via the remote control. NOTE: The remote will not shut off the humidifier by holding the remote button for 2 seconds. The user needs to scroll to "OF" to shut off the humidifier with the remote control. NOTE: Do not mix new and old batteries. Do not mix alkaline, standard (carbon-zinc), or rechargeable (nickel cadmium) batteries. and maintenance instructions, micro-organisms may be able to grow in the water within the humidifier's reservoir. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up. DAILY MAINTENANCE 1. Be sure the unit is OFF and is disconnected from the 4. DO NOT place humidifier near heat sources such as stoves, radiators, and heaters. DO locate your humidifier on an inside wall near an electrical outlet. cleaning procedures. Use only cleaners and additives recommended by the manufacturer. Never use gasoline, glass cleaner, furniture polish, paint thinner, to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary, an approved extension cord may be used. The electrical comfort level ranges from 30% and 65% relative humidity. 1. Select the Mode and or humidity you wish the A humidifier to run in. Fig 2 PERMAtech™ FILTER CLEANING INSTRUCTIONS 1. The water tray should be cleaned electrical outlet. 2. Remove the housing and the reservoir from the The humidifier should be at least 4" away from the wall for best results. 5. NEVER place humidifier in an area where it is accessible to children. NEVER use humidifier in a closed room, particularly where a child may be sleeping, resting, or playing (a closed room may result in excessive humidity). or other household solvents to clean any part of the humidifier. 17.Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn the humidifier OFF. 18.Do not use humidifier in an area where humidity level is in excess of 50%. Use a hygrometer, available at rating of the extension cord must be equal to or greater than the rating of the humidifier. Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over. HOW YOUR COOL MOISTURE HUMIDIFIER WORKS MANUAL MODE INSTRUCTIONS 1. Plug the humidifier into a 120V AC electrical outlet. 2. The display will show the current room humidity. 3. To start the unit, push the MODE/ OFF button once for the HIGH (3) manual setting. 4. Press the button again for the MEDIUM (2) manual 2. While the humidifier is C running, press and hold the D up and down buttons B simultaneously for 2 seconds. The display will flash "00". 3. By pressing the up and when you clean the filter. The water tray is a convenient way to carry the filter to prevent dripping. 2. Mix 1 gallon warm tap water with 1 teaspoon concentrated antibacterial liquid dish washing soap. Fig 4 humidifier and place in sink or tub. 3. Carry the base of the unit to the sink, remove the wick frame and wicks, place in sink, drain any remaining water and rinse thoroughly to remove any sediment or dirt. Wipe clean, and dry with a clean cloth or paper towel. NOTE: the base and wick frame are dishwasher safe 6. WARNING: Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet. your local retailer or through the manufacturer to measure the humidity. Your Bionaire® Cool Moisture humidifier draws dry air through the rear air intake grill area. This air is then setting and again for LOW (1). After the selection is made, the display will return to show the current room down buttons, program the humidifier to turn off up to A. Control Panel B. Mode/Off Button C. UP/DOWN Buttons D. Timer Light LED Display 3. Fully submerge filter in soap solution for 15-20 minutes. TOP RACK ONLY. 4. Drain the water from the tank into the sink and rinse Filter: BWF100P Read instructions before operating. Retain for future reference. Instruction Leaflet ☎ INFO-LINE If after having read this leaflet, you have any questions or comments on your air humidifier, call 1-800-253-2764 in North America. 9100030004077 Disinfect Humidifier Base and Reservoir: Failure to heed this warning may cause personal injury. Be sure to unplug the unit by pulling on the plug and not the cord. 7. Never place anything over moisture outlet when the unit is running. 8. NEVER drop or insert any object into any openings. DO NOT place hands, face or body directly over or near Moisture Outlet while unit is in operation. DO NOT cover Moisture Outlet while the unit is operating. 9. DO NOT operate any appliance with a damaged cord or plug, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Return appliance to manufacturer for examination, electrical or mechanical adjustment, or repair. 10.Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold the manufacturer may cause hazards. SERVICE INSTRUCTIONS 19.DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only. 20.Never place housing under water flow, or immerse in liquids. 21.DO NOT plug in the cord with wet hands, electric shock could result. 22.DO NOT pour water in any openings other than the water tank. 23.If you have a warm mist humidifier, allow unit to cool before refilling water tank or maintenance as the heater bulb is hot. 24.To prevent damage to surfaces, do not place humidifier under overhanging surfaces. 25.NEVER operate unit without water in the tank. 26.Use both hands when carrying full tank of water. Frequently Asked Questions passed through 4 moisture–laden wick filters which retains the minerals and deposits. The resulting moist air is directed back into the room from the top air grill. ☛ Tip: This humidification system provides a cool, invisible moisture output. It is normal not to see the mist. PRE-OPERATING INSTRUCTIONS 1. Be sure the humidifier is switched to OFF and the unit is disconnected from the electrical outlet. 2. Select a location for your humidifier, on a flat surface, about 4" away from the wall. DO NOT place the humidifier on a finished floor or near furniture, which can be damaged by moisture or water. Place on a moisture-resistant surface. 3. Remove the water reservoir, by holding the reservoir handle and lifting straight upwards. FILLING THE WATER TANK 1. Twist off the water reservoir cap located on the bottom of the water reservoir by turning counter clockwise and fill the water reservoir with cool fresh water. Do not fill with warm water as this may cause leaking. Troubleshooting for your Cool Mist Humidifier humidity. 5. To stop the unit, press and hold the button for two seconds, or keep pressing the button until the display reads "OF". HUMIDISTAT INSTRUCTIONS To take advantage of the Digital Humidistat, press the MODE/ OFF button until the speed is set in either the Auto HIGH (A3), Auto MEDIUM (A2) or Auto LOW (A1) setting. Then adjust the set humidity by using the up and down buttons. Humidity will increase in increments of 5%. When the humidity level is set, the display will return to show the current room humidity. When the room humidity level rises above the set humidity, the humidifier will stop. When the humidity level drops below the set humidity, the humidifier will turn on automatically. NOTE: Allow up to 30 minutes for the filter to fully absorb water and for the unit to produce moisture. NOTE: The Digital Humidistat has memory. This means that when you turn the unit back on, it will be at the last setting the humidifier was set at. TWO (2) YEARS LIMITED WARRANTY 16 hours later in increments of 1 hour. 4. After setting the timer, the display will return to show the current room temperature. The Timer light will illuminate to show that the timer is activated. 5. After the predetermined length of time has passed, the humidifier will automatically shut off. Setting the On Timer: 1. While the humidifier is off, press and hold the up and down buttons simultaneously for 2 seconds. 2. By pressing the up and down buttons, program the humidifier to turn on up to 16 hours in advance in increments of 1 hour. 3. The humidifier will continue to run on Auto Mode (HI) at 45% for 2 hours of run time. b) A dated sales receipt or PROOF OF PURCHASE, 4. Dunk filter in soap solution several times then gently press to release the soapy water. Be sure not to wring, pull or scrub filter as this will degrade the filter. 5. Run under cool tap water until there is no soap remaining. Some discoloration may still be visible, this is normal and does not affect performance. 6. Gently shake or press the filter to remove excess water. 7. The filter can be put directly into the humidifier while still damp if it is to be used right away, or allow filter to dry completely if humidifier is to be stored. Should your filter become damaged or lost, please call the customer service number listed in the manual for a replacement part: BWF100P. tank thoroughly. Wipe clean, and dry with a clean cloth or paper towel. 5. Put filters back in wick frame, replace on base, replace the housing, then refill tank with cool tap water as instructed earlier in the Filling Instructions. Do not overfill. 6. Follow Operating Instructions. WEEKLY MAINTENANCE Remove Scale: 1. Repeat steps 1-4 above. 2. Clean the base by partially filling the base with one 8-oz cup of undiluted white vinegar, or use Clean-Away™ by Bionaire®. Let solution stand 20 minutes, cleaning all interior surfaces with a soft brush. Dampen a cloth with undiluted white vinegar and wipe out entire base to remove scale. 3. Rinse with clean warm water to remove scale and the white vinegar solution before beginning to disinfect the reservoir. 1. Fill humidifier base with 1/4 gallon of water and 1/2 teaspoon of chlorine bleach. 2. Fill the reservoir 1/2 full with water and 1/2 teaspoon of chlorine bleach. 3. Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces. 4. Carefully empty the base and reservoir after 20 minutes, and rinse with water until you cannot detect any bleach smell. Dry with a clean cloth or paper towel. 5. Check the Filter Monitor to see if it is time to clean the filters. Depending on water hardness in your area, it may be necessary to clean the filter every 1-2 months. Re-insert the wick filters into the wick frame. 6. Refill the water tank as directed with cool tap water, repace the humidifier housing, and turn the unit on. STORAGE INSTRUCTIONS If your humidifier will not be in use for two days or more, or at the end of the season follow these instructions. 1. Clean and dry the humidifier thoroughly as per the "Weekly Maintenance" instructions. 2. Let the humidifier dry completely before storing. Do not store with water inside the base or water reservoir. 3. Remove the reservoir cap. Do not store with the reservoir cap in place. 4. Do not leave wick filters inside the humidifier. 5. Store in a cool dry location. 1. Do NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void the warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only. 2. If you need to exchange the unit, please return it in its original carton, with a sales receipt, to the store where you purchased it. If you are returning the unit more than 30 days after the date of purchase, please see the enclosed warranty. 3. Should your humidifier require service, please call 1-800-253-2764 in North America for further assistance. 4. If you have any other questions or comments, feel free to write to us or visit our website www.bionaire.com. Bionaire JCS/THG, LLC 303 Nelson Avenue Neosho, MO 64850 Question • What are the variables that affect run time? • How do I remove film on water tank? • How can I extend the run time? Answer The estimated run time for this humidifier is based on average room conditions. The actual run time of your humidifier is dependent on numerous variables such as: ✔ Air exchange in the room where the humidifier is placed. ✔ Room construction of the room where the humidifier is placed. ✔ Temperature of the room where the humidifier is placed. ✔ Humidity levels in the room where the humidifier is placed. ✔ Movement of occupants and the opening and closing of doors in the room where the humidifier is placed. ✔ Home furnishings in the room where the humidifier is placed. ✔ See Daily Maintenance instructions. Regular cleaning is recommended. ✔ Run your unit on the lowest setting. ✔ If your unit has electronics, set it to your desired humidity level. The unit will turn on and off, which will extend the run time. ✔ Fill the tank all the way full, place it on the base, let the water empty into the base until it stops bubbling, then refill the tank full again. This ensures maximum water capacity and will extend run time. Trouble • LED not illuminated. • Mist output minimal to none. • Water leaks from water reservoir. • Water Filter turns brown. • Film on water reservoir. • Water cloudy. • Humidistat cycles on/off. • Very tight reservoir cap. Probable Cause ☛ Unit not plugged in. ☛ Power failure. ☛ Filter has not absorbed water. ☛ Mineral buildup in base. ☛ Humidistat is set too low. ☛ Wick Filter needs to be replaced. ☛ Normal operation. ☛ Rubber O-ring is missing or improperly placed. ☛ Reservoir Cap not tight enough. ☛ Your filter needs to be cleaned. ☛ In areas with particular hard water your wick filter will need to be changed frequently. ☛ Mineral deposits cause film on tank to build up. ☛ Filter needs to be washed. ☛ Using warm water to refill reservoir. ☛ Humidifier is reacting to room humidity level. ☛ Over tightened. Solution ✔ Plug in unit. ✔ Check circuit breaker or outlet. ✔ Wait 15 minutes before starting humidifier. ✔ Regular cleaning of tray after each use will help keep the unit functioning properly. ✔ Set the humidistat to high. ✔ Follow cleaning instructions in manual. ✔ Mist is invisible. ✔ Check to see if inlet or outlet grills are blocked. ✔ Remove reservoir cap then replace or reposition ring. ✔ Tighten the reservoir cap. ✔ Follow cleaning instructions in manual. ✔ Use Clean-Away™ Solution (DMS216), to order call 1-800-253-2764, or visit www.bionaire.com. ✔ Follow cleaning instructions in manual. ✔ Refill using cool water. ✔ Set the humidistat to a higher or lower setting. ✔ Add liquid soap or petroleum jelly to cap gasket to ease opening. SAVE THIS WARRANTY INFORMATION A. This Warranty applies only to the original purchaser of this product. B. This Warranty applies ONLY to repair or replacement of any supplied or manufactured parts of this product that, upon inspection by JCS/THG, LLC authorized personnel, is shown to have failed in normal use due to defects in material or workmanship. JCS/THG, LLC will determine whether to repair or replace the unit. This Warranty does not apply to installation expenses. C. Operating this unit under conditions other than those recommended or at voltages other than the voltage indicated on the unit, or attempting to service or modify the unit, will render this WARRANTY VOID. D. Unless otherwise proscribed by law, JCS/THG, LLC shall not be liable for any personal injury, property or any incidental or consequential damage of any kind resulting from malfunctions, defects, misuse, improper installation or alteration of this product. E. All parts of this product excluding filters, which are covered under separate warranty, are guaranteed for a period of 2 years as follows: 1. Within the first 30 days from date of purchase, the store from which you purchased your product should replace this product if it is defective in material or workmanship (provided the store has in-stock replacement.) If you intend to assert any claim in connection with the product, please follow the instructions in paragraph F. 2. Within the first 24 months from date of purchase, JCS/THG, LLC will repair or replace the product if it is defective in material or workmanship, subject to the conditions in paragraph G. F. If you have any other problem or claim in connection with this product, please write to our Consumer Service Department. G. IMPORTANT RETURN INSTRUCTIONS. Your Warranty depends on your following these instructions if you are returning the unit to JCS/THG, LLC: 1. Carefully pack the item in its original carton or other suitable box to avoid damage in shipping. 2. Before packing your unit for return, be sure to enclose: a) Your name, full address with zip code and telephone number c) Your $10.00 check for return shipping and handling, and d) The model number of the unit and the problem you are having. (Enclose in an envelope and tape directly to the unit before the box is sealed.) 3. JCS/THG, LLC recommends you ship the package U.P.S. ground service for tracking purposes. 4. All shipping charges must be prepaid by you. 5. Mark the outside of your package: Bionaire JCS/THG, LLC 303 Nelson Avenue Neosho, MO 64850 SHIPPING AND HANDLING CHARGES: $10.00 (USD) This Warranty gives you specific legal rights, and you may have other rights which vary from state to state. The provisions of this Warranty are in addition to, and not a modification of, or subtraction from, the statutory warranties and other rights and remedies contained in any applicable legislation. To the extent that any provision of this Warranty is inconsistent with any applicable law, such provision shall be deemed voided or amended, as necessary, to comply with such law. © 2006 JCS/THG, LLC Bionaire®, the Bionaire logo™, Clean-Away™ and PERMAtech™ are trademarks of JCS/THG, LLC. BCM5555CN06EFM1 Printed in China BCM5555-CN06EFM1.qxd 7/3/06 15:50 Page 2 SÉCURITÉ DE L'HUMIDIFICATEUR VEUILLEZ LIRE ET 10.Ce produit est conçu pour une utilisation domestique seulement telle que décrite dans ce guide. Tout autre 19.Ne PAS tenter de réparer ou de mettre au point toute fonction électrique ou mécanique de cet appareil. Le IL NE FAUT PAS ESSAYER DE CONTOURNER LA FONCTION DE CETTE FICHE POLARISÉE. DIRECTIVES POUR L'UTILISATION Votre humidificateur est REMARQUE: Allouez jusqu'à 30 minutes pour permettre au filtre d'absorber entièrement l'eau et pour la production de Réglage de mise en marche du compteur horaire : 1. Quand l'humidificateur est à l'arrêt, appuyez et tenez les deux HUMIDIFICATEUR CONSERVER CES usage non recommandé par le fabricant peut causer des risques d'incendie, de choc électrique ou de fait de le faire annulerait la garantie. L'intérieur de l'appareil ne contient aucune pièce de service par le La longueur du cordon d'alimentation utilisé avec cet appareil électrique a été choisie pour réduire les risques équipé d'un hygrostat numérique de technologie Fig 1 Panneau de Moniteur de filtre contrôle l'humidité par l'unité. REMARQUE: L'humidificateur avec humidistat numérique est boutons enfoncés simultanément pendant 2 secondes. 2. En appuyant sur les boutons haut et bas, programmez numérique à VAPEUR FRAÎCHE MODÈLE BCM5555-CN CONSIGNES DE SÉCURITÉ IMPORTANTES DIRECTIVES IMPORTANTES Lors de l'usage de tout appareil électrique, des blessure. L'usage d'accessoires non recommandés ou non vendus par le fabricant peut présenter des dangers. 11.Ne PAS utiliser l'humidificateur à l'extérieur. 12.Toujours placer l'humidificateur sur une surface plane, ferme et à niveau. Nous vous recommandons de placer un napperon ou tapis imperméable sous l'appareil. Ne PAS placer l'humidificateur sur un tapis propriétaire. Les réparations et tâches d'entretien ne doivent être faites que par la personnel qualifié. 20.Ne jamais placer le boîtier sous l'eau courante ou l'immerger dans tout liquide. 21.Évitez de brancher le cordon si vos mains sont mouillées. Vous risqueriez un choc électrique. 22.Ne PAS verser d'eau dans les ouvertures de l'humidificateur, sauf le réservoir. d'emmêlement ou de trébuchement sur une corde plus longue. Si une corde plus longue est nécessaire, une corde de rallonge homologuée peut être utilisée. Le calibre du fil électrique de la corde de rallonge doit être le même ou plus élevé que celui de l'appareil. Des précautions doivent être prises pour disposer la corde de rallonge de manière à éviter de la passer par-dessus un de pointe. Vous pouvez régler l'humidificateur pour fonctionner continuellement en mode manuel ou régler l'hygrostat numérique au niveau d'humidité désirée. L'hygrostat numérique Poignée du réservoir Réservoir Boîtier doté d'une mémoire. Ceci signifie que lorsque vous remettez l'appareil en marche, il reviendra au dernier réglage précédemment enregistré. Si vous ne planifiez pas d'utiliser l'humidificateur pour deux jours ou plus, assurez-vous que toute eau résiduelle soit vidée du réservoir, de la base et des filtres à mèche pour prévenir la formation d'algues ou de bactéries. l'humidificateur pour être activé jusqu'à 16 heures à l'avance, en incréments de 1 heure. 3. L'humidificateur continuera de fonctionner en mode Auto (HI) à 45 % pour une période de 2 heures. DIRECTIVES D'UTILISATION DE LA TÉLÉCOMMANDE précautions fondamentales doivent être observées pour réduire le risque d'incendie, de choc électrique et de blessure, y compris celles-ci : ou plancher fini pouvant être endommagé par l'eau ou l'humidité. 13.Ne pas permettre à la sortie d'humidité de faire 23.Si votre humidificateur est à vapeur chaude, permettez à l'unité de se refroidir avant de remplir le réservoir comptoir ou un dessus de table où elle pourrait être tirée par un enfant ou causer un trébuchement accidentel. mettra automatiquement l'humidificateur en marche ou à l'arrêt, selon le niveau d'eau Porte-mèche RÉGLAGE DE FONCTIONNMENT POUR UNE PÉRIODE PROLONGÉE 1. Insérez 2 piles AAA à l'arrière de la télécommande. 2. Appuyez sur le bouton Mode de Fig 3 1. Lisez toutes les directives avant d'utiliser l'appareil. 2. Pour éviter les risques d'incendie ou de choc électrique, branchez l'appareil directement dans une prise de courant de 120 volts de courant alternatif. 3. Éviter de laisser traîner le cordon dans un endroit achalandé. Pour éviter les risques d'incendie, ÉVITEZ de placer le cordon d'alimentation sous les tapis et près des bouches d'air chaud. 4. ÉVITEZ de placer l'humidificateur près de sources de chaleur comme des cuisinières, radiateurs ou chaufferettes. PLACEZ-LE plutôt près d'un mur intérieur et d'une prise murale. Pour de meilleurs résultats, l'humidificateur doit être placé à au moins 4 po du mur. directement face à un mur. L'humidité peut causer des dommages, surtout au papier peint. 14.L'humidificateur doit être débranché s'il n'est pas utilisé. 15.NE JAMAIS incliner, déplacer ou tenter de vider l'unité pendant qu'elle fonctionne. Placez-la à l'arrêt et débranchez le cordon d'alimentation avant de retirer le réservoir d'eau et de déplacer l'unité. Si votre humidificateur est à vapeur chaude, NE PAS tenter d'enlever le réservoir d'eau avant 15 minutes après la mise à l'arrêt et le débranchement du cordon d'alimentation. Des blessures graves pourraient en résulter. 16.Cet humidificateur exige l'entretien quotidien et d'eau de nouveau ou d'en faire l'entretien, car l'élément de chauffage est chaud. 24.Pour prévenir les dommages aux surfaces, ne placez pas l'humidificateur sous les surfaces en saillie. 25.Ne JAMAIS faire fonctionner l'appareil sans que le réservoir soit rempli d'eau. 26.Lors du transport d'un réservoir plein d'eau, utilisez les deux mains. VEUILLEZ CONSERVER CES DIRECTIVES INFORMATION DE SÉCURITÉ DU CONSOMMATEUR COMMENT VOTRE HUMIDIFICATEUR À VAPEUR FRAÎCHE FONCTIONNE Votre humidificateur à vapeur fraîche Bionaire® aspire l'air sec par la grille d'admission d'air de la section arrière. Cet air est alors poussé à travers 4 filtres à mèche chargés d'humidité qui retiennent les minéraux et les dépôts de l'eau. L'air humide qui en résulte est dirigé dans la pièce en passant par la grille d'air supérieure. ☛ Consei: Ce système d'humidification fournit un débit d'humidité fraîche et invisible. Il est normal de ne pas voir la vapeur. INSTRUCTIONS AVANT L'UTILISATION 1. Assurez-vous que l'humidificateur est hors de service et que l'unité est débranchée de la prise de courant. de confort préréglé. Le niveau de confort est entre 35% et 65% d'humidité relative. UTILISATION EN MODE MANUEL 1. Branchez l'humidificateur dans une prise de courant de 120 volts de courant alternatif. 2. L'affichage indiquera le pourcentage d'humidité réelle de la pièce. 3. Pour activer l'unité, appuyez sur le bouton MODE/OFF une fois pour le réglage manuel HAUT (3). 4. Appuyez sur le bouton de nouveau pour le réglage manuel MOYEN (2) et une autre fois pour BAS (1). Quand le choix est fait, l'affichage reviendra pour indiquer le degré d'humidité actuel de la pièce. En réglant votre humidificateur à un niveau d'humidité spécifique, vous prolongez également la période du fonctionnement. Alors que l'unité s'activera et se placera hors de service automatiquement pour maintenir le niveau d'humidité réglé, moins d'eau sera utilisée et vous n'aurez pas à faire le plein d'eau aussi souvent que vous seriez requis de le faire en mode manuel. USAGE DU COMPTEUR HORAIRE PROGRAMMABLE L'hygrostat numérique permet à l'utilisateur de programmer l'humidificateur pour être activer ou mis hors de service à une heure prédéterminée. Réglage de l'arrêt du compteur horaire : 1. Choisissez le mode et ou la télécommande pour activer l'unité. 3. Utilisez la télécommande pour le contrôle des caractéristiques, de même manière que les contrôles de l'unité de base REMARQUE: La fonction du compteur horaire ne peut être activée qu'à l'unité de base. Elle ne peut pas être activée par la télécommande. REMARQUE: L'extérieur ne coupera pas l'humidificateur en tenant le bouton à distance pendant 2 secondes. L'utilisateur doit faire défiler à <
Không có nhận xét nào:
Đăng nhận xét