Thứ Tư, 22 tháng 9, 2021
Belkin Multiquip Submersible Pumps ST4125D, homeappliance
Download!
OPERATION AND PARTS MANUAL Submersible Pumps Model ST4125D Model ST6125D Revision #1 (06/12/08) To find the latest revision of this publication, visit our website at: www.multiquip.com THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES. Multiquip ST-4125D/ ST-4125D/ST-6125D — TABLE OF CONTENTS Submersible Pump ST-6125D Submersible Pumps Table Of Contents ..................................................... 2 Parts Ordering Procedures ....................................... 3 Safety Message Alert Symbols ................................. 5 Rules For Safe Operation ...................................... 6-7 Dimensions ............................................................... 8 Specifications (Pump) ...............................................9 General Information ................................................10 Submersible Pump Components ............................11 Float Switches .........................................................12 Control Boxes..........................................................13 Component Drawings ST-4125D Submersible Pump Assembly ...........28-29 ST-6125D Submersible Pump Assembly ...........30-33 Terms and Condition of Sale ...................................34 Specification and part numbers Control Box Installation ...........................................14 230/460 VAC Voltage Selection ...............................15 Control Box Wiring Diagram ....................................16 Three-Phase Power Installation ........................ 17-18 Set-up .....................................................................19 Operation .......................................................... 20-21 Maintenance ...........................................................22 Troubleshooting ......................................................23 Performance Curves ...............................................24 Explanation Of Codes In Remarks Column ............26 Suggested Spare Parts ...........................................27 NOTE are subject to change without notice. PAGE 2 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) m Best Deal! PARTS ORDERING PROCEDURES Ordering parts has never been easier! Choose from three easy options: Effective: January 1st, 2006 Order via Internet (Dealers Only): If you have an MQ Account, to obtain a o c . pi u Order parts on-line using Multiquip's SmartEquip website! ■ View Parts Diagrams ■ Order Parts ■Print Specification Information Goto www.multiquip.com and click on Order Parts to log in and save! Order via Fax (Dealers Only): All customers are welcome to order parts via Fax. Domestic (US) Customers dial: 1-800-6-PARTS-7 (800-672-7877) Username and Password, E-mail us at: parts@multiquip.com. To obtain an MQ Account, contact your District Sales Manager for more information. Use the internet and qualify for a 5% Discount on Standard orders for all orders which include complete part numbers.* Note: Discounts Are Subject To Change Fax your order in and qualify for a 2% Discount on Standard orders for all orders which include complete part numbers.* Note: Discounts Are Subject To Change q i t l Non-Dealer Customers: Order via Phone: Domestic (US) Dealers Call: 1-800-427-1244 International Customers should contact u Contact your local Multiquip Dealer for parts or call 800-427-1244 for help in locating a dealer near you. their local Multiquip Representatives for Parts Ordering information. When ordering parts, please supply: m. w ❒ Dealer Account Number ❒ Dealer Name and Address ❒ Shipping Address (if different than billing address) ❒ Return Fax Number ❒ Applicable Model Number ❒ Quantity, Part Number and Description of Each Part ❒ Specify Preferred Method of Shipment: ✓ UPS/Fed Ex ✓ DHL ■ Priority One ✓ Truck ■ Ground ■ Next Day ■ Second/Third Day ww All orders are treated as Standard Orders and will ship the same day if received prior to 3PM PST. WE ACCEPT ALL MAJOR CREDIT CARDS! ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 3 NOTES PAGE 4 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) ST-4125D/ST-6125D — SAFETY MESSAGE ALERT SYMBOLS FOR YOUR SAFETY AND THE SAFETY OF OTHERS! Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the Safety Messages and Operating Instructions could result in injury to yourself and others. This Owner's Manual has been developed to provide complete instructions for the safe and efficient HAZARD SYMBOLS Rotating Parts NEVER operate equipment with covers, or guards removed. Keep fingers, hands, hair and clothing away from all moving parts to prevent injury. NOTE operation of the Multiquip Models ST 4125D/ST6125D Submersible Pumps. Before using these pumps, ensure that the operating individual has read and understands all instructions in this manual. SAFETY MESSAGE ALERT SYMBOLS The three (3) Safety Messages shown below will inform you about potential hazards that could injure you or others. The Safety Messages specifically address the level of exposure to the operator, and are preceded by one of three words: DANGER, WARNING, or CAUTION. DANGER You WILL be KILLED or SERIOUSLY injured if you DO NOT follow directions. WARNING WARNING You CAN be KILLED or SERIOUSLY injured if you DO NOT follow directions. CAUTION CAUTION CAUTION You CAN be INJURED if you DO NOT follow directions. Potential hazards associated with the submersible pump's operation will be referenced with Hazard Symbols which appear throughout this manual, and will be referenced in conjunction Accidental Starting ALWAYS place the power source circuit breaker or ON/OFF switch in the OFF position, when the pump is not in use. Sight and Hearing hazard ALWAYS wear approved eye and hearing protection, if required. Respiratory Hazard ALWAYS wear approved respiratory protection, if required. Equipment Damage Messages Other important messages are provided throughout this manual to help prevent damage to your submersible pump, other property, or the surrounding environment. This submersible pump, other property, or the surrounding with Safety Message Alert Symbols. NOTE environment could be damaged if you do not follow instructions. ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 5 ST-4125D/ST-6125D — RULES FOR SAFE OPERATION WARNING - Read This Manual Failure to follow instructions in this manual may lead to serious injury or even death! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only. The following safety guidelines should always be used when operating the ST-4125D/ST-6125D Submersible Pump: GENERAL SAFETY ■ DO NOT operate or service this equipment before reading this entire manual. ■ This equipment should not be operated by persons under 18 years of age. ■ NEVER operate this equipment without proper protective clothing, shatterproof glasses, steel-toed boots and other protective devices required by the job. ■ NEVER operate this equipment when not feeling well due to fatigue, illness or taking medicine. ■ NEVER operate this equipment under the influence or drugs or alcohol. ■ NEVER use accessories or attachments, which are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result. ■ Manufacturer does not assume responsibility for any accident due to equipment modifications. ■ Whenever necessary, replace nameplate, operation and safety decals when they become difficult read. ■ ALWAYS check the machine for loosened threads or bolts before starting. ■ NEVER operate the submersible pump in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death. ■ ALWAYS make sure submersible pump is grounded. ■ NEVER use gas piping as an electrical ground. ■ DO NOT place hands or fingers inside pump when pump is running. ■ ALWAYS make certain that the voltage supplied to the pump is correct. Always read the pump's nameplate to determine what the power requirements are. The ST-4125D and ST-6125D submersible pumps require 230 or 460 VAC (three-phase) for normal operation. ■ DO NOT restrict the flow of the discharge hose as it may cause overheating. ■ Be careful of discharge whipping under pressure. ■ Make sure pump installation is in accordance with national and local electrical codes. ■ ALWAYS have a qualified electrician perform the pump wiring installation. ■ ALWAYS mount the control box in a vertical position protected from the elements. ■ NEVER handle pump's AC power cord with wet hands. ■ NEVER let an extension cord or plug connection lay in water. ■ NEVER stand in water while AC power cord is connected to a power source. ■ NEVER use a pump with a defective, frayed power cord. Check the power cord on the pump for cuts in the insulation. ■ NEVER use a extension cord that is frayed or damaged where the insulation has been cut. ■ ALWAYS make certain that proper extension cord has been selected for the job. ■ NEVER attempt to use the power cord as a lifting or lowering device for the submersible pump. ■ When raising or lowering of the submersible pump is required, always attach an adequate rope or lifting device to the correct lifting point (handle) on the pump. ■ ALWAYS place the pump in an upright position on a platform before using. The platform will prevent the pump from burrowing itself on soft sand or mud. ■ NEVER operate pump on its side. ■ DO NOT allow the pump to freeze in water. ■ NEVER leave an open pump chamber unattended. ■ The electrical voltage required to operate the pump can cause severe injury or even death through physical contact with live circuits. ALWAYS disconnect the electrical power from the pump before performing maintenance on the pump. ■ ALWAYS make sure that electrical circuits are properly grounded per the National Electrical Code (NEC) and PAGE 6 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) ST-4125D/ST-6125D— RULES FOR SAFE OPERATION local codes before operating pump. Severe injury or death by electrocution can result from operating an ungrounded pump. ■ ALWAYS be sure the operator is familiar with proper safety precautions and operations techniques before using submersible pump. ■ ALWAYS check pump oil level only when pump is cool. Expansion due to heat may cause hot! oil to spray from the oil plug when the oil plug is removed. ■ DO NOT attempt to thaw-out a frozen pump by using a torch or other source of flame. Application of heat in this manner may heat the oil in the seal cavity above the critical point, causing pump damage. ■ DO NOT pump water greater than 104 degrees Fahrenheit. Also DO NOT pump liquids containing acid or alkali. ■ ALWAYS check strainer before pumping. Make sure strainer is not clogged. Remove any large objects, dirt or debris from the strainer to prevent clogging. ■ ALWAYS use a large basket strainer when pumping water that contain large debris. ■ ALWAYS flush pump after use when pumping water concentrated with heavy debris. Flush with clean fresh water. It is very important to always flush the pump before turning it off to prevent clogging. ■ ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children. ■ ALWAYS read, understand, and follow procedures in Operator's Manual before attempting to operate equipment. Maintenance Safety ■ NEVER lubricate components or attempt service on a running machine. ■ ALWAYS allow the machine a proper amount of time to cool before servicing. ■ Keep the machinery in proper running condition. ■ Fix damage to the machine immediately and always replace broken parts. Emergencies ■ ALWAYS know the location of the nearest fire extinguisher. ■ ALWAYS know the location of the nearest and first aid kit. ■ In emergencies always know the location of the nearest phone or keep a phone on the job site. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency. ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 7 13.5 in (343 mm) ST-4125D SUBMERSIBLE PUMP 11.75 in (298 mm) 33.5 in (851 mm) ST-4125D/ST-6125D — DIMENSIONS 13.5 in (343 mm) 11 in (279 mm) 39 in (991 mm) ST-6125D SUBMERSIBLE PUMP 11.75 in (298 mm) ST-4125D ST-6125DFigure 1. Submersible Pump Dimensions PAGE 8 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) ST-4125D/ST-6125D — SPECIFICATIONS TABLE 1. SPECIFICATIONS M D odel S D T-4125 ST-6125 T p ype C p entrifugal Submersible Pum Centrifugal Submersible Pum I n mpeller C n ast Ductile Iro Cast Ductile Iro S ) uction & Discharge Size 2 ) .00 in. (51 mm 2.00 in. (51 mm Maximum Pumping Capacity464 gallons/minute (1,756 liters/minute) 610 gallons/minute (2,309 liters/minute) M ) ax Head 1 ) 25 ft. (38 meters 125 ft (38 meters P ) ower 1 ) 0 HP (7.5 kw 15 HP (11 kw V Ø oltage/Phase 2 Ø 30/460 3 230/460 3 Starting Amps149 (230V) 75 (460V) Running Amps27 (230V) 14 (460V) 215 (230V) 108 (460V) 39 (230V) 19.7 (460V) C 3 ontrol Box Required S 3 ee Note See Note P ) ower Cable Length 5 ) 0 ft. (15.2 m 50 ft. (15.2 m D ) ry Net Weight 3 ) 30 lb (150 kg 390 lb (177 kg H ) eight 3 ) 2.7 in (83.1 cm 38.8 in (98.6 cm D ) iameter 1 ) 4.2 in (36 cm 14.2 in (36 cm 1. Motor Rotation – Upon start-up, the pump "kicks" in the opposite direction of motor rotation. The correct rotation is counterclockwise (CCW) as viewed from the impeller end of the pump. 2. Mechanical Seal Oil – Use a good grade 10 weight non-detergent hydraulic oil (i.e. Shell Turbo 32 or equivalent). Fill oil cavity 75% to 85% full (allow air space for expansion). 3. Control Box - Control box (Table 2) is required for use to provide thermal overload protection to the pump. ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 9 ST-4125D/ST-6125D — GENERAL INFORMATION The Multiquip Model ST-4125D and ST-6125D submersible pumps are designed to pump water. These pumps work best when faced with high head applications where you need an appreciable flow. The ST-4125D and ST-6125D submersible pumps have dual voltage, easily switched between 230 and 460 volts. These pumps have a heavy-duty cast iron body that is very durable and able to withstand rough handling. The ST-4125D comes with NPT threads for standard hose connections while the ST-6125D is equipped with 6-inch flange fittings. The mechanical seal of these pumps operates within an oil filled chamber that provides positive lubrication. This helps prevent damage in the event the pump is run dry for short periods of time. PAGE 10 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) ST-4125D/ST-6125D — SUBMERSIBLE PUMP COMPONENTS 6 5 5 4 6 4 ST-4125D SUBMERSIBLE PUMP 3 3 ST-6125D SUBMERSIBLE PUMP 2 2 7 7 1 1 8 8 ST-4125D ST-6125D Figure 2. Submersible Pump Components Figure 2 shows the location of the basic components, for the ST-4125D and ST-6125D submersible pumps. Listed below is a brief explanation of each component. 1. Strainer Base – This strainer base is made of stainless steel which is resistant to hardware corrosion. For dewatering purposes, always place the strainer base on a platform. 2. Volute/Impeller – Impellers are constructed of cast ductile iron to minimize wear and prolong service life. 3. Electric Motor – The ST-4125D pump utilizes a 60 Hz, three-phase, 230/460 VAC, 10 HP electric motor and the ST-6125D pump utilizes a 60 Hz, three-phase, 230/ 460 VAC, 15 HP electric motor. Consult with a licensed electrician before connecting motor to a power source. Observe all city and local safety codes. 4. Discharge Port – Connect a 4-inch hose (ST-4125D) or 6-inch hose (ST-6125D) to this port. Remember to adequately support the discharge hose to avoid stress on the pump. 5. AC Power Cable – These pumps are supplied with a 50 ft. (15.2 meters) AC power cable. Always check the cable for signs of wear. NEVER use a defective power cable. Replace the cable immediately if the cable is worn or defective. 6. Eye Bolts – Always lift the submersible pump by the eye bolts using a chain and lifting device capable of lifting about 400 lbs. NEVER lift the pump by its power cord! Lifting the pump by the power cord will cause undue stress on the cord and ultimately the cord will become dislodged from the pump. 7. Mechanical Seal Oil – This oil-filled seal provides lubrication when running the pump dry. NEVER run the pump dry! Running the pump dry will cause severe damage to the pump. 8. Mechanical Seal Oil Plug – Remove this plug to check and add hydraulic oil (Shell 32 or equivalent) to the oil cavity. This oil protects the mechanical seal. Oil cavity should be full enough to cover seal spring. ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 11 Float Switch Theory ST-4125D/ST-6125D — FLOAT SWITCHES Float Switch (Dual) There is a tilt-sensitive mercury switch hermetically sealed within each float. As the liquid level (water) rises or falls, the float changes its angle until the mercury switch makes (close) or breaks (open) the circuit. The length of cord between the float and point of attachment determines the amount of water to be pumped. Contact Multiquip sales department to order float switches. EXTERNAL 3-PHASE (230 OR 460 VOLT) POWER SOURCE CIRCUIT BREAKER Float switches (Figure 3) are used for the unattended operation of the submersible pump. The ST-4125D and ST-6125D pumps require the use of a control box to perform this function. Shown in Figure 3 is an example of a dual float control switch application. The Models ST-4125D and ST-6125D submersible pumps require one each of the Model SW-1WOPA float type mercury switches. These switches have a pumping range level between 5.5~18 feet (1.67~5.5 meters). All float switch connections are bare wire (no plug). The ST-4125D/ST-6125D uses the CB12 control box for 230V and the CB14 control box for 460 V when float switches are required for the job application. L1 L2 L3 RED WHITE BLACK N E E R G GROUND R E W O L LIFTING CHAIN CONTROL BOX CAUTION! HIGH VOLTAGE! RESET CB12/14 4 or 6-INCH DISCHARGE HOSEPOWER CORD SUPPORT PLATFORM ST-6125D SUBMERSIBLE PUMP Figure 3. Dual Float Control Switch PUMP ON FLOAT SWITCHES PUMP OFF PAGE 12 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) ST-4125D/ST-6125D — CONTROL BOXES Control Boxes Control boxes (Figure 4) are required for remote control and thermal shutdown capability for the submersible pump. These water-resistant control boxes provide electronic overload protection, watertight housing and glands to prevent water from leaking into the box, and a float switch interface. Refer to Table 2 for the control box model that meets your pumping requirements. Contact Multiquip sales department to order control boxes as listed in Table 2. ALWAYS have a qualified CAUTION! HIGH VOLTAGE! RESET CB12/14 MAN OFF AUTO NOTE licensed electrician perform the installation of the control box. Figure 4. Electrical Control Box (Model CB12/14) Table 2. Control Box Specifications Control Box Used With UL/CSA Thermal Float Model No. Pump Model VoltageTypeHeater Size Full Load Amps Listed Overload Protection Switch Capability C D B12 ST-4125 230 VAC Three-PhaseK 7 67 2 S Y S E Y S E YE C D B12 ST-6125 230 VAC Three-PhaseK 9 73 3 S Y S E Y S E YE C D B14 ST-4125 460 VAC Three-PhaseK 4 56 1 S Y S E Y S E YE C D B14 ST-6125 460 VAC Three-PhaseK 7 62 1 S 9. Y S E Y S E YE ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 13 ST-4125D/ST-6125D — CONTROL BOX INSTALLATION DANGER - Hazardous Voltage DANGER - Hazardous Voltage To place the ST-4125D/ST6125D submersible pumps into operation requires the use of a control box. The control box contains the necessary electronics (thermal overload module, float switch connections and 230/460 voltage transformer) to operate the pump. Remember this control box contains hazardous voltages. Disconnect all sources of power before installing or servicing. There exists the possibility of electrocution, electric shock or burn, which can cause severe bodily harm or even death! CAUTION - Installation CAUTION - Installation This control box should only be installed or serviced by a licensed electrician or qualified personnel. CONTROL BOX MOUNTING Mount the control box in an upright vertical position. Make sure the control box is securely fastened to a flat surface, that is free of dust, dirt, moisture or any elements that may contaminate or erode the electronic components of the control box. 3-Phase Power Installation (Input) The ST-4125D/ST6125D submersible pump requires 230/ 460V 3-phase power for normal operation. The pump is shipped from the factory in the 230 VAC configuration. To change the voltage setting from 230 VAC to 460 VAC refer to the 230/460 VAC Selection section. If you cannot determine what your pump's power requirements are, look at the vendor supplied identification name tag attached to the pump or please contact Multiquip's Service/Technical Assistance department. CAUTION - Voltage Phasing CAUTION - Voltage PhasingApplying incorrect power (voltage phasing) to the submersible pump can cause severe damage to the pump. Please make sure that the correct voltage and phase are transferred to the pump at all times. POWER CORD REQUIREMENTS When routing the three phase power via a power cord to the control box, ALWAYS use the correct wire size. Please reference Table 3 below (Cord Length and Wire Size) to determine the correct wire size. Incorrect wire size can adversely affect the performance of the pump. TABLE 3. CORD LENGTH AND WIRE SIZES A . MPS 5 . 0 FT 1 . 00 FT 150 FT 6 G 1 G 6 AW 1 G 6 AW 14 AW 8 G 1 G 6 AW 1 G 4 AW 12 AW 1 G 0 1 G 6 AW 1 G 4 AW 12 AW 1 G 2 1 G 4 AW 1 G 4 AW 12 AW 1 G 4 1 G 4 AW 1 G 2 AW 10 AW 1 G 6 1 G 2 AW 1 G 2 AW 10 AW FLOAT SWITCH INSTALLATION 1. Remove the float switch input connector housing, then route the float switch wires through the cable gland on the control box. Attach the wires to the float switch terminal block as indicated by Table 4. Refer to Figures 7 and 8. TABLE 4. FLOAT SWITCH CONNECTIONSS FLOAT SWITCH FLOAT SWITCH TERMINAL BLOCK NUMBER S 2 TART TERMINALS 1 AND S 4 TOP TERMINALS 3 AND 2. Tighten the connector housing to ensure a tight fit between the cord and the connector body. This will prevent the cable from pulling out of the terminal block and also prevent moisture from entering the control box. 3. Determine the length of the float switch wires, then secure float switch wires to pump discharge hose. PAGE 14 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) ST-4125D/ST-6125D — 230/460 VAC VOLTAGE SELECTION 230/460 VAC Voltage Selection The ST-4125D/ST-6125D submersible pump is factory set at 230 VAC. To change the voltage from 230 VAC to 460 VAC, perform the following (refer to Figure 5): 1. Place pump in a suitable area free of dirt and debris. 2. Remove the four retaining screws, using a 19 mm socket, and the two Allen screws using an 8 mm socket, that secure the pump casing. 3. Lift the top of the pump by attaching a chain on the eye bolts and using a crane or similar equipment. Be careful not to fully stretch the cable connections inside the pump. 4. Cut the tie-wrap holding the 460 VAC motor winding wires as shown in Figure 5. Then remove the protective covering from the wires (labeled 4, 5, and 6). 5. Remove the sleeving covering the large red wire and separate the 2 wires labeled 1 and 7. 6. Connect the wire labeled 4 from step 4 to the wire labeled 7 from step 5 and join them with the large red wire. Cover the wires with sleeving. 7. Repeat steps 5 and 6 for the large black wire and the large white wire. Refer to the table in Figure 5 for wires to separate (column 2) and wires to connect (column 4). 8. Using electrical tape, bind the 3 wires that were separated and disconnected (labeled 1, 2, and 3). Place these wires neatly inside the housing. 9. Reinstall the top of the pump and reinsert the six screws and tighten securely. CUT TIE-WRAP REMOVE PROTECTIVE COVERING TO GAIN ACCESS TO 460 VAC WIRES 4, 5, AND 6. REMOVE SLEEVING WHITE (LARGE) BLACK 9 WHITE (SMALL) RED 4 56 BLACK (SMALL) BLACK (SMALL) GREEN 45 6 8 7 CONNECT TO GROUND SCREW IN UPPER CASING 460 VAC MOTOR WINDINGS 230/460 VAC MOTOR WINDINGS 230 VAC MOTOR WINDINGS 1 2 1 2 3 230 VAC 3 9 87 COMMON 460 VAC (HIGH VOLTAGE) U X W (LOW VOLTAGE) U 7 9 Z X 9 Y Z MOTOR WINDING 7 MOTOR WINDING 8 Y V STAR WITH NEUTRAL W 8 MOTOR WINDING CONFIGURATION STAR WITH NEUTRAL V 230 VAC INPUT 3Ø U (RED) V (WHITE) W (BLACK) MOTOR WINDINGS 1 AND 7 2 AND 8 3 AND 9 460 VAC INPUT 3Ø U (RED) V (WHITE) W (BLACK) MOTOR WINDINGS 4 AND 7 5 AND 8 6 AND 9 NOTEPUMP IS SHIPPED FROM THE FACTORY FOR 230 VAC OPERATION. FOR 460 VAC OPERATION SEE ABOVE WIRING ILLUSTRATION AND TABLE. Figure 5. 230/460 VAC Pump Voltage Selection ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 15 ST-4125D/ST-6125D — CONTROL BOX WIRING DIAGRAM THREE PHASE WIRING CONNECTIONS EXTERNAL 3-PHASE (230 OR 460 VOLT) POWER SOURCE CIRCUIT CB-12/CB-14 POWER INPUT M O/L L1 L2 L3 BREAKER RED WHITE BLACK N E E R L1 L2 L3 L1 L2 L3 RED AWG 8 RED AWG 8 RED AWG 8 H1 H3 H2 H4 BLK RED WHT T1 T2 T3 PUMP MOTOR GRN G GROUND XF F1 FUSE 1/2 AMP CONTROL TRANSFORMER 50VA CPT WHT X1 X2 GRN SEE TABLE 2 FOR CORRECT HEATER SELECTION 2 MAN OVERLOAD RELAY BLK 1 OFF O/L 4 AUTO RED NC X2 ON INDICATOR LAMP WHT AWG 10 G AWG 10 RED AWG 10 NO 3 4 RED AWG 10 CONTACTOR 5 HP M A2 A1 TERMINAL BLOCK WHT AWG 10 SELECTABLE 230 OR 460 VAC VOLTAGE INPUTS 43 2 STOP FLOAT SWITCH 1 START FLOAT SWITCH FUSE X1 XF X2 115120 X1 TRANSFORMER 110 H4 H2 H3 H1 JUMPER TAB L1 L2 230V INPUT H1 H3 H2 H4 CB-12 L1 L2 460V INPUT H1 H3 H2 H4 CB-14 Figure 7. Control Box Wiring Diagram PAGE 16 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) ST-4125D/ST-6125D — 3-PHASE POWER INSTALLATION 3-PHASE POWER CORD (INPUT TO BOX) INSTALLATION 1. The three phase input power cord should have four wires. Each wire is color coded. The colors are RED, WHITE, BLACK and GREEN. 2. Remove the 3-phase AC input connector housing from the control box, then route the three phase input power cable through the cable gland on the control box. Attach the wires to the AC terminal block inside the control box as indicated by Table 5 and Figure 8. TABLE 5. 3-PHASE AC INPUT POWER CONNECTIONSS 3-PHASE POWER INSTALLATION (OUTPUT TO PUMP) 1. The three phase output power cord should have four wires. Each wire is color coded. The colors are RED, WHITE, BLACK and GREEN. 2. Remove the 3-phase AC output power connector housing on the control box, then route the three phase output power cable through the cable gland on the control box. Attach the wires to the AC terminal blocks on the overload relay as indicated by Figure 8. Electrical connections to the power NOTE C # ABLE WIRE COLOR AC TERMINAL BLOCK R 1 ED L W 2 HITE L B 3 LACK L G D REEN GROUN 3. Tighten the connector housing to ensure a tight fit between the power cord and the connector body. This will prevent the cable from pulling out of the terminal block and also prevent moisture from entering the control box. It is recommended that the power being supplied to the control box ALWAYS be connected to a circuit breaker or a quick disconnect switch. This safety feature allows for quick removal of power from the control box in the event of an emergency. 4. Connect the other end of the 3-phase input power cord to the voltage source. Remember to provide a means of disconnecting the power from the control box (circuit breaker or quick disconnect switch). Also make sure to provide a good earth ground to the control box. source should only be performed by a licensed electrician or qualified personnel. ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 17 ST-4125D/ST-6125D — 3-PHASE POWER INSTALLATION MOUNT CONTROL BOX IN AN UP-LEFT VERTICAL POSITION AS SHOWN. L 7 T I 0 R ( S 7 2 X 0 0 AN T C 1L1 3 L2 5L3 40 24 X 8) 547 - 09 00 S FO RM ER O N TR OL E D M I C R O N 1 N C 2 O A . H 1- 2- 3- 4- T . B I m CONTROLLER 0 p U . . 7 e S T r P 5 E v A M 7 T i B 3 T . 5 . P N A V R . O T H C 3 A . L 5 Z 1 -3 N 6 0 01/ 8 - MNF ( 1 0 4 ) R 1 3 5 X 0 5 0 2 J F / FUSE K 6 C 0 H TESUFUEL-ELE D H Z 1 X 2 2 1 H 0 2 X TRANSFORMER 2 3 AC POWER TERMINAL BLOCK 2 0 2 1 3 4 1 0 1 4 4 0 H 1 1 5 2 H 1 2 0 3 H -4 1 2 0 4 4 3 0 4 8 X F 6 4 0 H 4 4 X 1 1- 2- 3- 4- 2T1 4T2 6T3 AEG 6 1 1 3 L3 L2 L1 L2 L3 0 OFF/ON LAMP MANUAL/AUTO FLOAT SWITCH 3 / 2 0 5 0 - SWITCH 0 2 TERMINAL BLOCK R M E A I S N E T T R EXTERNAL 3-PHASE 4 I L1 L2 L3 3 2 1 P OVERLOAD RELAY (230 OR 460 VOLT) POWER SOURCE CIRCUIT BREAKER BLK RED WHITE BLACK T2 T1 T3 BLK RED WHT HEATER SEE TABLE 2 L1 L2 L3 RED WHITE BLACK N E E R G 3 PHASE AC INPUT POWER CABLE GRN FLOAT SWITCH INPUTS GRN GROUND 3 PHASE AC OUTPUT POWER CABLE 1.SECURE FLOAT SWITCH WIRES TO PUMP DISCHARGE HOSE 2. START FLOAT SWITCH. CONNECT WARNING INSTALLATION OF THIS CONTROL BOX IS TO BE PERFORMED ONLY BY A LICENSED ELECTRICIAN OR QUALIFIED PERSONNEL. TO TERMINALS 1 AND 2 3. STOP FLOAT SWITCH. CONNECT TO TERMINALS 3 AND 4 Figure 8. Three Phase Control Box/Pump System Diagram PUMPING RANGE ST-6125D SUBMERSIBLE PUMP PAGE 18 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) Control Box Setup ST-4125D/ST-6125D — SETUP Reset 1. From the voltage source set the circuit breaker or quick disconnect switch to the ON position. 2. For manual operation of the pump, place the 3-position operation switch (Figure 9) on the control box in the MANUAL position. 1. When the overload module detects an overload, the unit will shut down. Check the unit and remove cause of overload. 2. Let the unit cool down and press the RESET button (see Figure 12) on the front of the control box to reset the unit (restore power). Figure 9. Manual-Off-Auto SW. (Manual Position) 3. Verify that the ON indicator (Figure 10) on the control box Figure 12. RESET Button Shut-Down is LIT. This means that power is being supplied to the control box. Figure 10. Control Box Power ON Indicator 4. In the manual mode the pump will run continuously. Pay close attention when running the pump in this mode. DAMAGE to the pump may occur if pump is not immersed in water. 5. To operate the pump automatically (float switches), place the 3-position operation switch in the AUTO position (Figure 11). Figure 11. Manual-Off-Auto SW. (Auto Position) 6. In the AUTO mode the pump will run as long as there is a sufficient amount of water. This amount is determined by the setting of the float switches. The stop float switch contacts will open when the water level is low and power will be removed from the pump's motor. Once the water level has risen back to the appropriate level the start float switch contacts will close and power will be restored to the pump's motor. 1. Place the 3-position operation switch on the control box to the OFF position (Figure 13). Figure 13. Manual-Off-Auto SW. (OFF Position) 2. Verify that the control box power ON light is OFF. 3. Turn the circuit breaker or quick disconnect switch to the OFF position. ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 19 ST-4125D/ST-6125D — OPERATION Operation 1. Attach a suitable lifting chain to the eye bolts (Figure 14) on the pump and using a crane, or similar equipment, lower the pump into place. For applications where there is an exces sive amount of mud, grit or silt, the use of a support platform is desirable. R E W O L 2. Make sure the pump is always placed in an upright position, not tilted (Figure 15). Never position the pump directly on a soft, loose bottom. Remember to attain maximum pumping capacity and prevent excessive wear, position the pump so it will not burrow itself into sand or clay. R E W O L LIFTING CHAIN 4 or 6-INCH DISCHARGE HOSE ST-6125D SUBMERSIBLE PUMP CONNECT TO CONTROL BOX POWER CORD SUPPORT PLATFORM ST-6125D SUBMERSIBLE PUMP Figure 14. Placing the Submersible Pump (Correct Upright Position) CAUTION - Pump Use CAUTION - Pump UseDO NOT use this pump for swimming pool applications! Figure 15. Incorrect Tilted Position 3. After the pump has been positioned correctly into place, power can be applied to the pump's electric motor. PAGE 20 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) 4. NEVER grab or touch a live power cord (Figure 16) with wet hands, the possibility exists of electrical shock, electrocu tion and even death. WET HANDS POWER CORD (POWER ON) Figure 16. Power Cord (Wet Hands) DANGER - Electrocution Hazard DANGER - Electrocution Hazard NEVER grab or touch a live power cord. DO NOT stand in water when connecting the pump's power cord into a voltage source. The possibility exist of electrical shock, electrocution and possibly death! 3. If all of the pump's electrical requirements have been met, insert the power plug on the pump into the power source receptacle. 4. Wait a few seconds and water should begin to flow from the discharge hose. 5. If water is not flowing from the discharge hose or not flowing freely after a few minutes, remove the power from the pump and check the system for leaks. ST-4125D/ST-6125D — OPERATION Pump Shut-Down/Clean-up 1. Remove the power from the pump by turning off the circuit breaker or switch that provides power to the pump. Remem ber to make sure that hands are dry (not wet), and feet are not standing in water when removing disconnecting power from the pump. 2. Using the chain and lifting crane, lift the pump up from its current position. Remove the discharge hose from the dis charge port on the pump. 3. Remove all power cables and float switches from the control box. Place cables and float switches in a suitable container where they will not get damaged. 4. If the pump was used to pump mud, grit or silt, flush vigorously with clean water. 5. Remove the pump from the water. Wipe off any mud or debris that might have attached itself to the pump. 6. Store pump in a clean dry place away from dirt and debris. ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 21 LUBRICATION ST-4125D/ST-6125D— MAINTENANCE 5. If oil level is low fill with SAE 10 weight non-detergent To check the oil level of the mechanical seal perform the following: 1. Lay the pump (Figure 17) on its side with the oil plug facing upwards. 2. Remove oil fill plug. 3. Visually inspect oil plug hole to verify that oil cavity is full enough to cover seal spring. Check every 300 hours, change hydraulic oil every 6 months (1,000 hours) or as needed. 4. While checking the hydraulic oil level, also check the condition of the hydraulic oil in the seal cavity . Block the opening with a finger and roll pump to one side to drain oil into a small transparent container. If oil is cloudy or has water in it, drain oil from pump cavity and replace hydrau lic oil. Check the seal for wear damage. LAY PUMP FLAT ON ITS SIDE hydraulic oil (i.e. Shell Turbo 32 or equivalent). Fill oil cavity 75% to 85% full (allow air space for expansion). Pump oil cavity capacity is approximately 180 cc. IMPELLER 1. Make sure the clearance between the impeller and the friction disk is approximately .012 - .020 inches (.304 - .508 mm.) 2. If impeller is defective or badly worn, replace impeller imme diately. REMOVE FILL PLUG, AND VISUALLY INSPECT THAT OIL CAVITY IS FULL ENOUGH TO COVER SEAL SPRING. FILL TO 75-80% CAPACITY (APPROXIMATELY 180 CC.) FILL WITH 10 WEIGHT NON DETERGENT HYDRAULIC OIL. USE SHELL TURBO 32 OR EQUIVALENT. CHECK HYDRAULIC OIL EVERY 300 HOURS. CHANGE EVERY 6 MONTHS OR AS NEEDED. Figure 17. Checking Hydraulic Oil PAGE 22 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) ST-4125D/ST-6125D — TROUBLESHOOTING Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 6 (Pump Troubleshooting) as a basic guideline for troubleshooting the pump. If the problem cannot be remedied, contact Multiquip's service department. TABLE 6. PUMP TROUBLESHOOTING SYMPTOM POSSIBLE PROBLEM SOLUTION Check that proper voltage (230/460 3Ø) is being supplied to the pump. Incorrect voltage/amps? Also check that there is an adequate amount of current (amps) to run the pump. Check power source circuit breaker. Pump Fails To Start Check electrical connections? If using float switches check wiring, inspect power cord. Blown power fuse? Replace fuse, check cause of blown fuse. Impeller locked? Disconnect power cord and check for clogging and improper impeller clearance. Unclog pump. Check overload protection device. Use multimeter to check motor insulation. Insulation resistance must Wet motor windings? Defective motor and pump bearings? Twisted or restricted discharge hose? be approximately 15 megaohms. If resistance is low, disassemble pump motor and bake windings to dry them. Check for excessive bearing wear, if worn replace bearings. Replace motor if defective. Lay hose flat un-kinked. Remove clog from hose line. Pump Fails to Deliver Full Output Clogged pump strainer? Clean strainer. Use a voltmeter to check voltage while pump is energized. Voltage must be within ±10%. Check power source (no load and load). If an Low voltage? extension cord is used, make sure it has adequate current-carrying capacity for the required length. Water in Seal Oil Impeller worn? Replace impeller. Defective water seal? Replace water seal. Loose Oil Fill Plug? Tighten securely. ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 23 ST-4125D/ST-6125D — PERFORMANCE CURVES ST4125D Performance Curve 140 120 100 80 ) t e 60 60 e F ( d a e H l a t o T 40 20 0 100 200 300 400 500 600 TOTAL HEAD Max 125 ft CAPACITY Max 464 G.P.M Capacity(US.G.P.M) ST6125D Performance Curve 140 120 100 80 ) t e 60 60 e F ( d a e H l a t o T 40 20 0 100 200 300 400 500 600 TOTAL HEAD Max 125 ft CAPACITY Max 610 G.P.M Capacity(US.G.P.M) Figure 18. Pump Performance Curves PAGE 24 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) NOTES ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 25 EXPLANATION OF CODE IN REMARKS COLUMN The following section explains the different symbols and remarks used in the Parts section of this manual. Use the help numbers found on the back page of the manual if there are any questions. The contents and part numbers listed in the parts section are subject to change without notice. Multiquip does not guarantee the availibility of the parts listed. Sample Parts List: NO. PART NO. PART NAME QTY. REMARKS 1 12345 BOLT ...................... 1 ......INCLUDES ITEMS W/* 2* WASHER, 1/4 IN. .............NOT SOLD SEPARATELY 2* 12347 WASHER, 3/8 IN. ... 1 ......MQ-45T ONLY 3 12348 HOSE ................... A/R ....MAKE LOCALLY 4 12349 BEARING ............... 1 ......S/N 2345B AND ABOVE NO. Column Unique Symbols - All items with same unique symbol (*, #, +, %, or >) in the number column belong to the same assembly or kit, which is indicated by a note in the "Remarks" column. Duplicate Item Numbers - Duplicate numbers indicate multiple part numbers are in effect for the same general item, such as different size saw blade guards in use or a part that has been updated on newer versions of the same machine. When ordering a part that has more than one item number listed, check the remarks column for help in determining the proper part to order. PART NO. Column Numbers Used - Part numbers can be indicated by a number, a blank entry, or TBD. TBD (To Be Determined) is generally used to show a part that has not been assigned a formal part number at time of publication. A blank entry generally indicates that the item is not sold separately or is not sold by Multiquip. Other entries will be clarified in the "Remarks" Column. QTY. Column Numbers Used - Item quantity can be indicated by a number, a blank entry, or A/R. A/R (As Required) is generally used for hoses or other parts that are sold in bulk and cut to length. A blank entry generally indicates that the item is not sold separately. Other entries will be clarified in the "Remarks" Column. REMARKS Column Some of the most common notes found in the "Remarks" Column are listed below. Other additional notes needed to describe the item can also be shown. Assembly/Kit - All items on the parts list with the same unique symbol will be included when this item is purchased. Indicated by: "INCLUDES ITEMS W/(unique symbol)" Serial Number Break - Used to list an effective serial number range where a particular part is used. Indicated by: "S/N XXXXX AND BELOW" "S/N XXXX AND ABOVE" "S/N XXXX TO S/N XXX" Specific Model Number Use - Indicates that the part is used only with the specific model number or model number variant listed. It can also be used to show a part is NOT used on a specific model or model number variant. Indicated by: "XXXXX ONLY" "NOT USED ON XXXX" "Make/Obtain Locally" - Indicates that the part can be purchased at any hardware shop or made out of available items. Examples include battery cables, shims, and certain washers and nuts. "Not Sold Separately" - Indicates that an item cannot be purchased as a separate item and is either part of an assembly/kit that can be purchased, or is not available for sale through Multiquip. PAGE 26 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) ST-4125D/ST-6125D — SUGGESTED SPARE PARTS ST-4125D/ST-6125D SUBMERSIBLE PUMP 1 TO 3 UNITS Qty. P/N Description Remarks 1 1027620 KIT, MECHANICAL SEAL, SLEEVE, O-RINGS ST4125D 1 1027622 KIT, MECHANICAL SEAL, SLEEVE, O-RINGS ST6125D ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 27 ST-4125D SUBMERSIBLE PUMP ASSY. 1 3 2 4 6 5 ST-4125D — SUBMERSIBLE PUMP ASSY. 50 19 46 18 33 MECHANICAL SEAL, SLEEVE, O-RINGS KIT 2820 27 7 29 21 36 43 32 30 22 16 23 44 31 49 910 11 8 12 17 34 35 1314 45 42 37 40 38 39 41 48 47 15 26 25 PAGE 28 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) ST-4125D — SUBMERSIBLE PUMP ASSY. ST-4125D SUBMERSIBLE PUMP ASSY. NO PART NO PART NAME QTY. REMARKS 1 1025754 CABLE, POWER, 22 MM 50' 1 2 1042600 CABLE GLAND, DIA.38 1 3 ST4125D031 BOLT, M12X25L 2 4 1040546 CABLE BUSH, DIA.34 1 5 1042601 CABLE ENTRY ASSY. 1 6 ST4125D061 BOLT 7 7 1042602 MOULDING TUBE 1 8 1042604 VOLUTE, HOUSING 1 9 ST4125D0201 BOLT, M12X40L 1 10# ST4125D0204 O-RING, DIA.35X190 4 11 1042605 LOWER PACKING 1 12 1042607 IMPELLER 1 13 1042608 SUCTION COVER 1 14 ST4125D0221 BOLT, M12XM20L 4 15 1042609 STRAINER 1 16# ST4125D025 MECHANICAL SEAL 1 17 1040547 OIL SEAL 2 18 ST4125D032 HOSE CONNECTION, DISCHARGE 2" 1 19 ST4125D0321 BOLT, M10X25L 4 20# ST4125D0324 O-RING, DIA.3.1X105 1 21 1040548 OIL PLUG, M12 1 22 1042612 SEAL STOPPER 1 23 ST4125D0391 BOLT, M5X10L 3 25 1042613 BOTTOM PLATE 1 26 ST4125D0491 BOLT, M12X120L 3 27 1042614 MOTOR COVER 1 28 ST4125D0501 BOLT, M12X35L, M10X35L 6 29# ST4125D0504 O-RING, DIA.35X232 1 30 1042615 PACKING, UPPER 1 31 1042616 BALL BEARING, UPPER, #6306ZZC3 1 32 1042617 THERMAL PROTECTOR 3 33# TBD GASKET, FLANGE HOSE CONNECTION 1 34 1042618 NUT, IMPELLER, M20X2.5P 1 35 ST4125D055 ROTOR, UNIT 1 36 1042619 STATOR 1 37 1042620 BALL BEARING (LOWER)#6308/#7308 2 38 1042621 BEARING HOUSING, LOWER 1 39 ST4125D0601 BOLT, M8X20L 6 40# ST4125D0604 O-RING, DIA.3.1/135 1 41 1042623 BEARING COVER 1 42 ST4125D0611 BOLT, M6X16L 4 43 1042624 STATOR HOUSING 1 44 ST4125D0641 BOLT, M10X100L 2 45 1042625 KEY, 7X7X30 1 46 1042627 EYE BOLT, LIFTING,W3/4" 2 47 1033125 SEAL, LEAKAGE SENSOR 1 48 1040549 STOP RING 1 49 ST4125D0157 WAVE WASHER, DIA.55X70.5X0.4 1 50 1027620 KIT, MECHANICAL SEAL, SLEEVE, O-RINGS..........1 ...........INCLUDES ITEMS W/ # ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 29 ST-6125D SUBMERSIBLE PUMP ASSY. 1 ST-6125D — SUBMERSIBLE PUMP ASSY. 3 2 6 5 18 4 24 50 19 24 46 33 MECHANICAL SEAL, SLEEVE, 2820 27 7 29 O-RINGS KIT 21 36 43 32 30 22 16 23 44 31 49 910 11 8 17 12 34 35 1314 45 42 37 40 38 39 41 48 47 15 26 25 PAGE 30 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) ST-6125D SUBMERSIBLE PUMP ASSY. ST-6125D — SUBMERSIBLE PUMP ASSY. NO PART NO PART NAME QTY. REMARKS 1 1035149 CABLE, POWER, 24 MM 50' 1 2 1042637 CABLE GLAND, DIA.38 1 3 ST6125D031 BOLT, M12X25L 2 4 1042638 CABLE BUSH, DIA.34 1 5 1042639 CABLE ENTRY ASSY. 1 6 ST6125D061 BOLT 7 7 1042640 MOULDING TUBE 1 8 1042641 VOLUTE, HOUSING 1 9 ST6125D02011 BOLT, M12X40L 1 10# ST6125D0204 O-RING, DIA.35X190 4 11 1042642 LOWER PACKING 1 12 1042643 IMPELLER 1 13 1042644 SUCTION COVER 1 14 ST6125D0221 BOLT, M12XM20L 4 15 1042645 STRAINER 1 16# ST6125D025 MECHANICAL SEAL 1 17 1042646 OIL SEAL 2 18 1042647 FLANGE, HOSE CONNECTION DISCHARGE 1 19 ST6125D0321 BOLT, M10X25L 4 20# ST6125D0324 O-RING, DIA.3.1X105 1 21 1042648 OIL PLUG, M12 1 22 1042649 SEAL STOPPER, (OPTIONAL) 1 23 ST6125D0391 BOLT, M5X10L 3 24 1042611 HOSE CONNECTION, DISCHARGE 1 25 1042650 BOTTOM PLATE 1 26 ST6125D0491 BOLT, BOTTOM PLATE, M12X120L 3 27 1042651 MOTOR COVER 1 28 ST6125D0501 BOLT, M12X35L, M10X35L 6 29# ST6125D0504 O-RING, DIA.35X232 1 30 1042652 UPPER PACKING 1 ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 31 ST-6125D SUBMERSIBLE PUMP ASSY. 1 ST-6125D — SUBMERSIBLE PUMP ASSY. 3 2 6 5 18 4 24 50 19 24 46 33 MECHANICAL SEAL, SLEEVE, 2820 27 7 29 O-RINGS KIT 21 36 43 32 30 22 16 23 44 31 49 910 11 8 17 12 34 35 1314 45 42 37 40 38 39 41 48 47 15 26 25 PAGE 32 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) ST-6125D — SUBMERSIBLE PUMP ASSY. (CONTINUED) ST-6125D SUBMERSIBLE PUMP ASSY. (CONTINUED) NO PART NO PART NAME QTY. REMARKS 31 1042653 BALL BEARING, UPPER, #6306ZZC3 1 32 1042617 THERMAL SENSOR 3 33# TBD GASKET, DISCHARGE CONNECTION 1 34 1042655 NUT, IMPELLER, M20X2.5P 1 35 1042654 ROTOR UNIT 1 36 1042663 STATOR 1 37 1042664 BALL BEARING, LOWER, #6308/#7308 2 38 1042665 BEARING HOUSING, LOWER 1 39 ST6125D0601 BOLT, M8X20L 6 40# ST6125D0604 O-RING, DIA.3.1/135 1 41 1042666 BEARING COVER 1 42 ST6125D0611 BOLT, M6X16L 4 43 1042667 STATOR HOUSING 1 44 ST6125D0641 BOLT, M10X100L 2 45 1042668 KEY, IMPELLER, 7X7X30 1 46 1042670 EYE BOLT, LIFTING, W3/4" 2 47 1033125 SEAL LEAKAGE SENSOR 1 48 1042671 STOP RING, S-40 1 49 ST6125D0157 WAVE WASHER, DIA.55X70.5X0.4 1 50 1027622 KIT, MECHANICAL SEAL, SLEEVE, O-RINGS .... 1 ....................INCLUDES ITEMS W/ # ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 33 TERMS AND CONDITIONS OF SALE — PARTS PAYMENT TERMS Terms of payment for parts are net 30 days. FREIGHT POLICY All parts orders will be shipped collect or prepaid with the charges added to the invoice. All shipments are F.O.B. point of origin. Multiquip's responsibility ceases when a signed manifest has been obtained from the carrier, and any claim for shortage or damage must be settled between the consignee and the carrier. MINIMUM ORDER The minimum charge for orders from Multiquip is $15.00 net. Customers will be asked for instructions regarding handling of orders not meeting this requirement. RETURNED GOODS POLICY Return shipments will be accepted and credit will be allowed, subject to the following provi sions: 1. A Returned Material Authorization must be approved by Multiquip prior to ship ment. 2. To obtain a Return Material Authorization, a list must be provided to Multiquip Parts Sales that defines item numbers, quanti ties, and descriptions of the items to be returned. a. The parts numbers and descriptions must match the current parts price list. b. The list must be typed or computer generated. c. The list must state the reason(s) for the return. d. The list must reference the sales order(s) or invoice(s) under which the items were originally purchased. e. The list must include the name and phone number of the person request ing the RMA. 3. A copy of the Return Material Authoriza tion must accompany the return shipment. 4. Freight is at the sender's expense. All parts must be returned freight prepaid to Multiquip's designated receiving point. 5. Parts must be in new and resalable con dition, in the original Multiquip package (if any), and with Multiquip part numbers clearly marked. 6. The following items are not returnable: a. Obsolete parts. (If an item is in the price book and shows as being re placed by another item, it is obsolete.) b. Any parts with a limited shelf life (such as gaskets, seals, "O" rings, and other rubber parts) that were pur chased more than six months prior to the return date. c. Any line item with an extended dealer net price of less than $5.00. d. Special order items. e. Electrical components. f. Paint, chemicals, and lubricants. g. Decals and paper products. h. Items purchased in kits. 7. The sender will be notified of any material received that is not acceptable. 8. Such material will be held for five working days from notification, pending instruc tions. If a reply is not received within five days, the material will be returned to the sender at his expense. 9. Credit on returned parts will be issued at dealer net price at time of the original purchase, less a 15% restocking charge. 10. In cases where an item is accepted, for which the original purchase document can not be determined, the price will be based on the list price that was effective twelve months prior to the RMA date. 11. Credit issued will be applied to future purchases only. PRICING AND REBATES Prices are subject to change without prior notice. Price changes are effective on a spe cific date and all orders received on or after that date will be billed at the revised price. Rebates for price declines and added charges for price increases will not be made for stock on hand at the time of any price change. Multiquip reserves the right to quote and sell direct to Government agencies, and to Original Equipment Manufacturer accounts who use our products as integral parts of their own products. SPECIAL EXPEDITING SERVICE A $35.00 surcharge will be added to the invoice for special handling including bus shipments, insured parcel post or in cases where Multiquip must personally deliver the parts to the carrier. LIMITATIONS OF SELLER'S LIABILITY Multiquip shall not be liable hereunder for damages in excess of the purchase price of the item with respect to which damages are claimed, and in no event shall Multiquip be liable for loss of profit or good will or for any other special, consequential or incidental dam ages. LIMITATION OF WARRANTIES No warranties, express or implied, are made in connection with the sale of parts or trade accessories nor as to any engine not manufac tured by Multiquip. Such warranties made in connection with the sale of new, complete units are made exclusively by a statement of war ranty packaged with such units, and Multiquip neither assumes nor authorizes any person to assume for it any other obligation or liability whatever in connection with the sale of its products. Apart from such written statement of warranty, there are no warranties, express, implied or statutory, which extend beyond the description of the products on the face hereof. Effective: February 22, 2006 PAGE 34 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) NOTES ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 35 OPERATION AND PARTS MANUAL HERE'S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING UNITED STATES Multiquip Corporate Office MQ Parts Department 18910 Wilmington Ave. Tel. (800) 421-1244 800-427-1244 Fax: 800-672-7877 Carson, CA 90746 Fax (800) 537-3927 310-537-3700 Fax: 310-637-3284 Contact: mq@multiquip.com Mayco Parts Warranty Department 800-306-2926 Fax: 800-672-7877 800-421-1244, Ext. 279 Fax: 310-537-1173 310-537-3700 Fax: 310-637-3284 310-537-3700, Ext. 279 Service Department Technical Assistance 800-421-1244 Fax: 310-537-4259 800-478-1244 Fax: 310-631-5032 310-537-3700 MEXICO UNITED KINGDOM MQ Cipsa Multiquip (UK) Limited Head Office Carr. Fed. Mexico-Puebla KM 126.5 Tel: (52) 222-225-9900 Hanover Mill, Fitzroy Street, Tel: 0161 339 2223 Momoxpan, Cholula, Puebla 72760 Mexico Fax: (52) 222-285-0420 Ashton-under-Lyne, Fax: 0161 339 3226 Contact: pmastretta@cipsa.com.mx Lancashire OL7 0TL Contact: sales@multiquip.co.uk CANADA BRAZIL Multiquip Multiquip 4110 Industriel Boul. Tel: (450) 625-2244 Av. Evandro Lins e Silva, 840 - grupo 505 Tel: 011-55-21-3433-9055 Laval, Quebec, Canada H7L 6V3 Fax: (450) 625-8664 Barra de Tijuca - Rio de Janeiro Fax: 011-55-21-3433-9055 Contact: jmartin@multiquip.com Contact: cnavarro@multiquip.com.br, srentes@multiquip.com.br © COPYRIGHT 2008, MULTIQUIP INC. Multiquip Inc and the MQ logo are registered trademarks of Multiquip Inc. and may not be used, reproduced, or altered without written permission. All other trademarks are the property of their respective owners and used with permission. This manual MUST accompany the equipment at all times. This manual is considered a permanent part of the equipment and should remain with the unit if resold. The information and specifications included in this publication were in effect at the time of approval for printing. Illustrations, descriptions, references and technical data contained in this manual are for guidance only and may not be considered as binding. Multiquip Inc. reserves the right to discontinue or change specifications, design or the information published in this publication at any time without notice and without incurring any obligations. Your Local Dealer is:
Đăng ký:
Đăng Nhận xét (Atom)
Black & Decker Black&Decker Vacuum NV4820CN, homeappliance
Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...
-
Download! BERNINA® www.berninausa.com What is BSR? The BERNINA® Stitch Regulator The revolutionary Bernina Stitch Regulator (BSR) all...
-
Download! Power Vent & Power Direct Vent Replacement Parts No. Part Name and Description Repair Parts Illustration Repair Part...
-
Download! Service Handbook RESIDENTIAL HYBRID ELECTRIC HEAT PUMP WATER HEATER FOR MODELS: HPE10260H045DV (60 GAL.) HPE10280H045DV (...
Không có nhận xét nào:
Đăng nhận xét