Thứ Ba, 21 tháng 9, 2021
Beckett CG10B, homeappliance
Download!
Fire, Explosion and Asphyxiation Hazards COMMERCIAL PRODUCTS GAS-FIRED Failure to follow these instructions exactly could lead to fi re or explosion and result in death, severe personal injury or property damage. 1. Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance. 2. What to do if you smell gas: - Do not try to light any appliance. - Do not touch any electrical switch. - Do not use any phone in your building. - Immediately call your gas supplier from a telephone outside the building. - Follow the gas supplier's instructions. - Call the fi re department if you cannot contact your supplier. 3. Installation and service must be performed by a qualifi ed installer, service agency, or the gas supplier. 2 Contents General Information ....................................................4 Hazard Defi nitions .........................................................................4 Professional Installer's Responsibility ...........................................5 Pre-installation Checklist ...........................................5 Indoor Installation ..........................................................................5 Combustion Air Supply ..................................................................5 Clearances ....................................................................................5 Fuel Gas Supply ...........................................................................5 Flue Vent System ..........................................................................5 Electrical Supply ............................................................................7 Verify Burner Components ............................................................7 Verify Firing Input Range ...............................................................7 Verify Burner Air Tube Assembly ...................................................7 Mount the Burner ....................................................... 10 Connect Gas Piping .................................................. 10 Gas Trains ...................................................................................11 Wire the Burner .......................................................... 14 Sequence of Operation ............................................. 14 Prepare the Burner for Start-up ............................... 17 Start-up Checklist .......................................................................17 Start the Burner ........................................................ 18 Burner Start Procedure ...............................................................18 Initial Air Settings .........................................................................18 Optional Modulation Linkage Adjustment Instructions ................20 Adjustment Procedure .................................................................20 Modulation Control ......................................................................22 Verify Input Firing Rate ................................................................23 Estimating Rate ...........................................................................24 Clocking a Gas Meter ..................................................................24 Uncorrected Flow Rate ...............................................................24 Pressure Correction ....................................................................24 Temperature Correction ..............................................................24 BTU's and MBH...........................................................................24 Check Operation and Safety Controls .........................................26 Use Test Instruments to Set Combustion ....................................27 Recommended Combustion Test Sequence ...............................27 Maintenance and Service.......................................... 28 Annual Maintenance ..................................................................28 Appliance ....................................................................................28 Gas Supply Piping .......................................................................29 Installation Area ...........................................................................29 Adjust the Burner for Proper Combustion ..................................29 Flame Safeguard .........................................................................29 Manual Shutdown for Long Periods ............................................29 Ignition Reliability ........................................................................29 Propane Restrictor Description ..................................................31 Installation ..................................................................................31 For the Operator ..........................................................................33 Replacement Parts .................................................... 34 Limited Warranty Information .................................. 36 CG15, CG25, CG50 Burner Manual3 Section: General Information General Information Hazard Defi nitions Indicates a hazardous situation which, if not avoided, will result in death or serious injury. Indicates a hazardous situation, which, if not avoided, could result in death, or serious injury. Owner's Responsibility Failure to follow these instructions, misuse, or incorrect adjustment of the burner could lead to equipment malfunction and result in asphyxiation, explosion or fi re. Contact a professional, qualifi ed service agency for the installation, adjustment, and service of your gas burning system. Thereafter, have your equipment adjusted and inspected at least annually to ensure reliable operation. This work requires technical training, trade experience, licensing or certifi cation in some states and the proper use of special combustion test instruments. Please carefully read and comply with the following instructions: Used with the safety ⮹ alert symbol, indicates a ⮹ hazardous situation, which, if not avoided, may result in minor or moderate injury. ⮹ ⮹ Within the boundaries of the hazard warning, there will be information presented describing consequences if the ⮹ warning is not headed and instructions on how to avoid the hazard. ⮹ Used to address practices not related to personal injury. See the front cover for 'What to do if you smell gas'. Never store or use gasoline or other fl ammable liquids or vapors near this burner or appliance. Never attempt to burn garbage or refuse in this appliance. Never attempt to light the burner/appliance by throwing burning material into the appliance. Never attempt to burn any fuel not specifi ed and approved for use in this burner. Never restrict the air inlet openings to the burner or the combustion air ventilation openings in the room. Frozen Plumbing and Water Damage Hazard To the Owner: Thank you for purchasing a Beckett burner for use with your heating appliance. Please pay attention to the Safety Warnings contained within this instruction manual. Keep this manual for your records and provide it to your qualifi ed service agency for use in professionally setting up and maintaining your burner. Your CG series gas burner will provide years of effi cient operation if it is professionally installed and maintained by a qualifi ed service technician. If at any time the burner does not appear to be operating properly, immediately contact your qualifi ed service agency for consultation. We recommend annual inspection/service of your gas heating system by a qualifi ed service agency. If the facility is unattended in severely cold weather, burner primary control safety lockout, heating system component failures, power outages or other electrical system failures could result in frozen plumbing and water damage in a matter of hours. For protection, take preventive actions such as having a security system installed that operates during power outages, senses low temperature and initiates an effective action. Consult with your heating contractor or security agency. 4 Professional Installer's Responsibility Follow these instructions exactly Failure to follow these instructions could lead to equipment malfunction and result in asphyxiation, explosion or fi re. Section: Pre-installation Checklist Combustion Air Supply The burner requires combustion air and ventilation air for reliable operation. Assure that the building and/or combustion air openings comply with the latest edition of the National Fuel Gas Code ANSI Z223.1 (NFPA 54). For appliance/burner units in confi ned spaces, the room must have an air opening near the top of the room, plus ⮹ Please read all instructions before proceeding. Follow all instructions completely. ⮹ This equipment must be installed, adjusted, and started by a qualifi ed service agency that is licensed and experienced with all applicable codes and ordinances and responsible for the installation and commissioning of the equipment. ⮹ The installation must comply with all local codes and ordinances having jurisdiction and the latest edition of the National Fuel Gas Code ANSI Z223.1 (NFPA 54) and CAN1-B149.1 in Canada. Concealed damage – If you discover damage to the burner or one near the fl oor, each with a free area at least one square inch per 1000 Btu/hr input for all fuel-burning equipment in the room. For Canadian installations, refer to latest edition of CAN1- B149.1 standard. If there is risk of the space being under negative pressure, or of exhaust fans or other devices depleting available air for combustion and ventilation, the appliance/burner should be installed in an isolated room provided with outside combustion air. Clearances With the burner installed in the appliance, there must controls during unpacking, notify the carrier at once and fi le the appropriate claim forms. High altitude installations – Accepted industry practice requires no derate of burner capacity up to 2000 feet above sea level. For altitudes higher than 2000 feet, derate the burner capacity 2% for each 1000 feet above the 2000 feet. 50 Hz motors – The burner ratings, air settings and other adjustments are based on 60 Hz motors at 3450 rpm. Derate fi ring capacity 20% when using 50 Hz motors. Consult factory for specifi c application data. Pre-installation Checklist Indoor Installation Protect against Dust and Moisture Wet or dusty environments could lead to blocked air passages, corrosion damage to components, impaired combustion performance and result in asphyxiation, explosion or fi re. be adequate space in front of and on the sides of the burner to allow access and operation. Verify that the clearance dimensions comply with local codes and with the appliance manufacturer's recommendations. Fuel Gas Supply Verify that the gas supply piping complies with all applicable local codes and the latest edition of the National Fuel Gas Code ANSI Z223.1 (NFPA 54). Insure that the supply gas pipe size is capable of providing at least the minimum pressure required to the burner gas train inlet at the burner's full capacity rating. Refer to Table 1. Flue Vent System The fl ue gas vent system must be in good condition and must comply with National Fuel Gas Code ANSI Z223.1 (NFPA 54) and all other applicable codes having jurisdiction for vent construction, capacity, and sizing. ⮹ This burner is designed for clean, dry installations. ⮹ Electrical controls are not protected against rain or sprayed liquids. ⮹ Keep the installation clear of dust, dirt, corrosive vapors, and moisture. ⮹ Protective covers and more frequent maintenance may be required. CG15, CG25, CG50 Burner Manual 5 Section: Pre-installation Checklist Table 1 – Burner Specifi cations CG15 CG25 CG50 Input Firing Range†: USA Canada USA Canada USA Canada High Fire (Max.) High Fire (Min.) Low Fire (Max.) Low Fire (Min.) Fuel: 1,500 MBH 800 MBH 560 MBH 350 MBH 1,370 MBH 800 MBH 560 MBH 350 MBH 2,700 MBH 1,300 MBH 990 MBH 550 MBH ? MBH 1,300 MBH 990 MBH 550 MBH 5,000 MBH 2,000 MBH 1,400 MBH 730 MBH 4,000 MBH 2,000 MBH 1,400 MBH 730 MBH Natural Gas Propane (LP) Gas Train: Standard Options Gas Train Inlet Pressure: Minimum Maximum Manifold to Furnace Pressure Drop:** Highest High Fire Lowest High Fire 0.6 Specifi c Gravity Typical 1.53 Specifi c Gravity Typical UL Listed / CSD-1 confi guration IRI, FM 3.7" WC* 10 PSI 3.7" WC 2.7" WC 0.6 Specifi c Gravity Typ. 1.53 Specifi c Gravity Typ. UL Listed / CSD-1 confi guration IRI, FM 3.5" WC* 10 PSI 3.5" WC 2.5" WC 0.6 Specifi c Gravity Typ. 1.53 Specifi c Gravity Typ. UL Listed / CSD-1 confi guration IRI, FM 3.5" WC* 10 PSI 3.5" WC 2.5" WC Firing Modes Available: Low Fire Start High/Low Modulation Standard Flame Safeguard: - High/Low Modulation - High/Low Modulation Low Fire Start High / Low Modulation Flame Detector: Standard Optional RM7897A RM7897C RM7897C Flame Rod UV - RM7897C RM7840L UV - - RM7897C RM7840L UV - Airfl ow Proving Switch: Standard Standard Standard Gas Pressure Switches: Standard High and Low Standard High and Low Standard High and Low Ignition: Direct Ignition of Main Flame Direct Ignition of Main Flame Direct Ignition of Main Flame Motor: HP RPM Standard Voltage Motor FLA Optional Voltages 1/2HP 3450 RPM 120 volt, 1 ph, 60 Hz 6.4 Amps @120 volt AC 208/230v, 1 ph, 60 Hz 208/230v, 3 ph, 60 Hz 460v, 3 ph, 60 Hz 575v, 3 ph, 60 Hz 3/4 HP 3450 RPM 120 volt, 1 ph, 60 Hz 10.4 Amps @120 volt AC 208/230v, 1 ph, 60 Hz 208/230v, 3 ph, 60 Hz 460v, 3 ph, 60 Hz 575v, 3 ph, 60 Hz 2 HP 3450 RPM 208/230v, 1 ph, 60 Hz 13.4 Amps @230 volt AC 208/230v, 3 ph, 60 Hz 460v, 3 ph, 60 Hz 575v, 3 ph, 60 Hz Weight: 125 lbs. 145 lbs. 165 lbs. Dimensions: Refer to Figures 4 & 5. *See manufacturer's nameplate settings for specifi c minimum gas pressure requirements. ** See Figures 14A, 14B, & 14C. † Canada High Fire rate is reduced to accomodate 25% reserve air. Figure 1 - Burner Label Location General Model Information Serial Number, Including Date Code Rating Information Approval Agency Symbols Fuel R.W. Beckett Construction & Setting Data R.W. Beckett Specifi cation Number and Revision Boiler Manufacturer and Model, When Applicable Additional Codes 6 Test For Gas Pipe Leaks Electrical Supply Section: Pre-installation Checklist Leaking gas could result in asphyxiation, explosion, or fi re hazard. Check the nameplate on the burner to verify that the power connections available are correct for the burner. Refer to Figure 1. All power must be supplied through ⮹ The gas supply piping must be absolutely leak-free. ⮹ Pressure test the gas piping with air that is at least three times greater than the gas pressure being used. ⮹ Verify that there are no leaks before proceeding. fused disconnect switches and comply with the latest edition of National Electric Code NFPA 70 (Canada CSA C22.1) and all other local or applicable codes. Verify Burner Components Burner model can be checked from burner carton or Figure 2 - Minimum Combustion Chamber Dimensions Minimum Inside Dimensions (inches) Burner rating label on burner. Flange mounting arrangement (Includes high temperature gasket and/or fi ber rope for pressure fi ring). Verify Firing Input Range Refer to appliance manufacturer's instructions (if available) for the fi ring input range. Otherwise the maximum recommended fi ring range for the burner depends on the length and width of the fi ring chamber and the distance from the burner center to the chamber fl oor. Verify that the chamber dimensions are at least as large as the minimum values given in Figure 2. If the appliance dimensions are smaller, reduce the fi ring rate Burner Model Width 'W' Height 'H' Length 'L' at Min H & W* Head Centerline to fl oor 'A' accordingly. Flames are shaped by their CG15.1S 15 16 42 7 CG15.2S 16 17 45 8 CG15.3S 17 18 47 8 CG15.4S 18 19 50 9 CG25.1S 19 20 45 9 CG25.2S 20 21 48 10 CG25.3S 21 22 50 10 CG25.4S 22 23 52 11 CG25.5S 23 25 55 11 CG50.1S 21 23 55 10 CG50.2S 22 24 58 11 CG50.3S 24 26 62 12 CG50.4S 25 27 65 12 CG50.5S 27 29 70 13 furnaces and by its fl ue locations. Increased height and width can decrease the length requirement. When shaping is too severe fl ames impinge on the walls. Impingement causes CO and carbon deposits and may damage the wall. Maintaining these minimum dimensions should prevent impingement, but smaller furnaces may be acceptable depending upon the results of applications testing. We recommend factory testing of all new burner/furnace combinations by the furnace manufacturer and/or R. W. Beckett Corp. The volume of the furnace also infl uences the combustion process. R. W. Beckett Corp. recommends at least 1 cubic foot of furnace volume for each 150,000 BTU/Hr of fi ring rate. Verify Burner Air Tube Assembly ○ Dimensions shown are for cast iron sectional boilers with uptakes between sections. For minimum dimensions of other ○ furnace types consult R. W. Beckett Corporation. ○ The information in this section may be disregarded if the burner supplied by the appliance manufacturer is a matched component. Maximum fi ring capacity depends on the furnace pressure. Use the charts shown in Figure 3A, Figure 3B, and Figure 3C, to verify the correct burner confi guration for the input rate. Refer to Figures 4 & 5 to verify the air tube assembly length and mounting insertion dimensions. CG15, CG25, CG50 Burner Manual 7 Section: Pre-installation Checklist Figure 3A - Maximum Capacity (at 3% O2) vs Furnace Pressure - CG15, 60Hz. Figure 3B - Maximum Capacity (at 3% O2) vs Furnace Pressure - CG25, 60Hz. Figure 3C - Maximum Capacity (at 3% O2) vs Furnace Pressure - CG50, 60Hz. 8 Figure 4 - Burner Dimensions DIM. A DIM. B O.D. DIM. E DIM. C DIM. D DIM. F Section: Pre-installation Checklist DIM. G DIM. H Model Dim. A Dim. B Dim. C Dim. D Dim. E Dim. F Dim. G Dim. H O.D. Pipe Thread CG15 20.8 9.4 32.7 13.7 5.2 18.4 6.2 10.8 5.6 1-1/4 NPT CG25 20.9 9.3 33.2 13.4 6.8 17.8 6.7 12.6 6.9 2 NPT CG50 24.4 10.5 33.6 13.5 7.5 17.4 6.7 14.6 7.7 2-1/2 NPT NOTE: All dimensions are in inches. Figure 5 - Panel and Modulating Valve Dimensions 16.00 8.00 DIM. A FEMALE PIPE THREAD 6.00 12.4 DIM. B Model Dim. A Dim. B Pipe Thread CG15 5.12 11.75 1-1/4 NPT CG25 5.12 11.75 2 NPT CG50 5.81 13.25 2-1/2 NPT *Dimensions are in inches CG15, CG25, CG50 Burner Manual 9 Section: Mount the Burner & Connect Gas PipingMount the Burner Mount the burner to the appliance. The burner specifi ed for packaged equipment will have a fl ange welded for the required insertion. Follow the appliance manufacturer's instructions for mounting. In the absence of instructions, or for retrofi ts, make sure that the air tube insertion dimension, measured along the side of the air tube from the welded fl ange to the end of burner air tube, is correct. Protect the Air Tube from Overheating Overheating could cause damage to the air tube and other combustion components leading to equipment malfunction and impaired combustion performance. Figure 6 - Custom Mounting Plate C B A Key: ⮹ The end of the air tube must not extend into the combustion chamber unprotected unless it has been factory-tested and specifi ed by the appliance manufacturer. ⮹ The end of the air tube should be set back ¼" from fl ush with the refractory inside wall to prevent damage from overheating. ⮹ Refer to the instructions outlined in this section for methods of additional protection. If this dimension cannot be achieved, protect the ○ end of the air tube by installing a suitable ceramic refractory material such as a refractory mill board A = Burner mounting fl ange B = Gasket C = Appliance mounting plate Connect Gas Piping Do Not Use Tefl on Tape on Gas Piping Damage to gas valve cutoff seals and valve bodies could cause gas leaks and result in asphyxiation, explosion or fi re. capable of withstanding at least 2300 degrees F. ⮹ The entry hole diameter in the appliance should be 1" larger than the air tube to facilitate ease of installation and provide adequate protection. ⮹ Referring to Figure 6, if the front plate opening (C) ○ in the boiler is larger than the burner fl ange bolt circle, then a custom mounting plate (A) of at least 1/4" thickness must be used with a suitable high ⮹ temperature refractory material anchored on the fi re side. A suitable high-temperature gasket (B) must be used for an effective seal. Attach the plate and gasket to the boiler and tighten ○ the mounting nuts or bolts securely. Pieces of tape can be cut loose during installation and lodge in gas valves causing cutoff seal problems. Tefl on tape 'lubricates' pipe threads, allowing iron pipes to penetrate too deeply into aluminum valve bodies causing distortion and leakage. Use only pipe sealant compounds that are resistant to the gas being used. All gas piping installation must comply with the latest edition of the ○ Verify that the air tube is ¼" back from fl ush (see Figure 2), and there is nothing blocking the fl ame zone that could cause fl ame impingement. National Fuel Gas Code ANSI Z223.1 (NFPA 54) and other applicable local codes. The gas supply system must be sized to deliver at least the minimum required pressure to the gas train inlet. Contact your local gas utility for verifi cation of gas pressures, allowable pressure drops, and any local piping code requirements. Refer to Figure 7 for an illustration of a gas piping layout and refer to Table 2 for pipe sizing. 10 Install a Drip Leg in Gas Supply Piping Foreign matter could lodge in gas valve cutoff seals, resulting in gas leak-through, explosion or fi re. Install a full-size drip leg or dirt pocket in the piping directly ahead of the main shutoff valve to capture foreign matter. Gas Trains Gas Leaks and Explosion Hazards Provide Over-pressure Protection CSD-1 requires that if gas pressure entering the building exceeds the rating of any gas train component an overpressure protection device must be installed. Standard – An Underwriters Laboratories (UL) listed gas train is standard for the CG10 gas burner. This confi guration also meets CSD-1 requirements. See Figures 8A and 8B for typical component layout. Propane (LP) – When the correct propane restrictor is added to a burner's gas pipe assembly it changes the burner's gas pressure drop so that the propane pressure drop is equal to the natural gas pressure drop of the same BTU fi ring rate. That is why the Manifold Figure 7 - Typical Gas Piping Layout Section: Connect Gas Piping to Furnace Pressure Drop curves of Figures 14A, 14B, and 14C are correct for both propane and natural gas. That is also why a gas train adjusted for the burner's natural gas requirements will be correctly adjusted for its propane requirements. R. W. Beckett provides the same pressure regulating safety shutoff valve in the gas train (usually a Honeywell V4944B) for both natural gas and propane. The valve is marked for natural gas due to its primary usage in a pressure range normally used by natural gas appliances. It is safe and effective for propane usage in this design application. Optional – Gas trains for IRI and FM are available and must be specifi ed when ordering a burner. Verify – Verify that the train components are not damaged and all piping and fi ttings are clean inside and out. The gas train is normally shipped as components and must be assembled and installed at the site. Vent Lines – Install vent lines to any gas valve component that requires atmospheric air pressure to balance a diaphragm. Vent lines must be run to the outdoors, with the termination point away from fresh air intakes and windows. The terminal opening must be fi tted with a wire mesh screen to block insects and other contaminants from entering the vent and must be mounted in such a position that water, ice, dirt, or any other foreign matter cannot infi ltrate and block the vent piping. Make sure the fi nal assembly is anchored securely. ABBREV. HGPS LGPS MSC MLTC PG S SSOV1 TC U 2PRV ITEM DESCRIPTION HIGH GAS PRESSURE SWITCH LOW GAS PRESSURE SWITCH MAIN SHUTOFF COCK MAIN LEAK TEST COCK PRESSURE GAUGE STRAINER SAFETY SHUTOFF VALVE #1 TEST COCK UNION TWO POSITION REGULATING VALVE LGPS HGPS METER BURNER REGULATOR PG U MSC U SSOV1 TC 2PRV TC MLTC U TC DRIP LEG S (IF USED) GAS UTILITY PIPING FACILITY PIPING GAS TRAIN BURNER CG15, CG25, CG50 Burner Manual 11 Section: Connect Gas Piping Table 2A - Natural Gas Supply Piping Capacity Schedule 40 metallic pipe with 0.50 psi or less inlet pressure and 0.30" W.C. pressure drop Maximum capacity in cubic feet of gas per hour (CFH). Natural gas with 0.60 specifi c gravity. Pipe size (inches) IPS Pipe length (feet) 0.75" 1.0" 1.25" 1.5" 2.0" 2.5" 3.0" 4.0" 10 278 520 1050 1600 3050 4800 8500 17500 20 190 350 730 1100 2100 3300 5900 12000 30 152 285 590 800 1650 2700 4700 9700 40 130 245 500 760 1450 2300 4100 8300 50 115 215 440 670 1270 2000 3600 7400 60 105 195 400 610 1150 1850 3250 6800 70 96 180 370 560 1050 1700 3000 6200 80 90 170 350 530 990 1600 2800 5800 90 84 160 320 490 930 1500 2600 5400 100 79 150 305 460 870 1400 2500 5100 125 72 130 275 410 780 1250 2200 4500 150 64 120 250 380 710 1130 2000 4100 175 59 110 225 350 650 1050 1850 3800 200 55 100 210 320 610 980 1700 3500 Table 2B - Propane (LP) Gas Supply Piping Capacity Schedule 40 metallic pipe with 11"W.C. inlet pressure and 0.50" W.C. pressure drop Maximum capacity in thousands of BTU/HR (MBH). LP Gas with 1.53 Specifi c Gravity. Pipe Size (inches) IPS Pipe length (feet) 0.5" .75" 1.0" 1.25" 1.5" 2.0" 2.5" 3.0" 10 275 567 1,071 2,205 3,307 6,221 10,140 17,990 20 189 393 732 1,496 2.299 4,331 7,046 12,510 30 152 315 590 1,212 1,858 3,465 5,695 10,110 40 129 267 504 1,039 1,559 2,992 4,778 8,481 50 114 237 448 913 1,417 2,646 4,343 7,708 60 103 217 409 834 1,275 2,394 3,908 6,936 80 89 185 346 724 1,086 2,047 3,329 5,908 100 78 162 307 630 976 1,811 2,991 5,309 125 69 146 275 567 866 1,606 2,654 4,711 150 63 132 252 511 787 1,496 2,412 4,281 200 54 112 209 439 665 1,282 2,038 3,618 12 Section: Connect Gas Piping Figure 8A - UL Gas Train - High/Low and Low Fire Start LGPS TC TC HGPS MSC SSOV1 2PRSSOV MLTC U TP U SK9982 SK9983 Figure 8B - UL Gas Train - Modulating LGPS TC TC HGPS MSC PRV U SSOV1 SSOV2 MLTC U MV TP SK9984 SK9985 ABBREV. HGPS LGPS MSC MLTC MV SSOV1 SSOV2 ITEM DESCRIPTION HIGH GAS PRESSURE SWITCH LOW GAS PRESSURE SWITCH MAIN SHUTOFF COCK MAIN LEAK TEST COCK MODULATION VALVE SAFETY SHUTOFF VALVE #1 SAFETY SHUTOFF VALVE #2 When pressure reducing safety shutoff valves are used, the distance from the fi nal shutoff valve (2PRSSOV in Figure 8A) to the burner manifold must be kept to a minimum for good light-off reliability. R. W. Beckett recommends the following maximum lengths: TC TP U 2PRSSOV TEST COCK TEST PORT UNION HIGH/LOW PRESSURE REGULATING SAFETY SHUTOFF VALVE Pipe Size 1" 1-1/4" 1-1/2" 2" Maximum Length 12" 15" 18" 24" If Normally Open Vent Valve (not shown) is used, the distance between the SSOVs must be kept to a minimum using the shortest practical nipples. CG15, CG25, CG50 Burner Manual 13 Section: Wire the Burner & Sequence of OperationWire the Burner Install the burner and all wiring in accordance with the National Electric Code ANSI/NFPA 70 (Canada CSA C22.1) and all applicable codes and requirements. Wire the burner in compliance with all instructions and diagrams provided by the appliance manufacturer. Verify operation of all controls in accordance with the appliance manufacturer's guidelines. Incorrect Wiring Will Result in Improper Control Operation Fire or Explosion Hazard Can cause severe injury, death, or property damage. ⮹ Do Not Bypass Safety Controls ⮹ Tampering with, or bypassing safety controls could lead to equipment malfunction and result in ⮹ asphyxiation, explosion or fi re. The control can malfunction if it gets wet, leading to accumulation of explosive vapors. Never install where water can fl ood, drip or condense on the control. Never use a control that has been wet - replace it. ⮹ Safety controls are designed and installed to provide protection. ⮹ Do NOT tamper with or bypass any safety control. ⮹ If a safety control is not functioning properly, shut off all main electrical power and gas supply to the burner Sequence of Operation RM7897C & RM7840L Flame Safeguard Controls 1. and call a qualifi ed service agency immediately. See Figures 9A & 9B for typical wiring diagrams, with the fl ame safeguard control, for reference purposes only. Check 2. the literature that was packaged with the burner for the primary control manufacturer's instructions and the exact wiring diagram for your specifi c burner. 3. Electrical Shock Hazard Electrical shock can cause severe personal 4. injury or death. Initiate – The primary control enters the INITIATE sequence when the control is fi rst powered on or power returns after an interruption. The initiate sequence is a ten second delay during which the control verifi es line voltage stability. Standby – The control enters STANDBY until the limits, operating limit control, burner switch, and all microcomputer-monitored circuits are in the correct state. Load Demand – Operating limit control contacts close on drop in temperature (or pressure) and initiates the start sequence. Prepurge – The control will signal the PREPURGE sequence when the airfl ow interlock and all ⮹ Disconnect electrical power before installing or servicing the burner. switches are in the correct state. The Prepurge sequence is the amount of time the blower motor ⮹ Provide ground wiring to the burner, metal control enclosures and accessories. (This may also be required to aid proper control system operation.) Perform all wiring in compliance with the National ⮹ Electrical Code ANSI/NFPA 70 (Canada CSA C22.1) Keep Service Access Covers Securely Installed 5. runs prior to the ignition start sequence. Timing for the Prepurge sequence is determined by a card mounted inside the control module (typically 30 seconds). For the RM7897A control, Prepurge is conducted with the air damper in the low fi re position. For the RM7840 control the air damper opens to the high fi re position for the timed prepurge period and returns to the low fi re position before releasing the control for ignition. Trial for Ignition (TFI) – After the Prepurge These covers must be securely in place to prevent electrical shock, damage from external elements, and protect against injury from moving parts. sequence has timed out, the ignition and main gas valves will be energized. Because the burner has direct spark ignition for the main fl ame, the fl ame ⮹ All covers or service access plates must be in place at all times except during maintenance and service. 6. ⮹ This applies to all controls, panels, enclosures, switches, and guards or any component with a cover 7. as part of its design. must be established and detected by the control within 4 seconds or lockout will occur. Flame Stabilization – The burner will operate in low fi re for 10 seconds before initiating high fi re. Run – With a fl ame established and the control 14 continuing to detect a fl ame, the burner will operate ○ in the RUN mode until the load demand is satisfi ed or a limit opens. Section: Sequence of Operation For modulating control wiring (Figure 9B), the burner starts at Low and is released to modulate after the fl ame stabilization period. It can ○ For High/Low control wiring (Figure 9A), if terminals RC1 and RC2 are jumpered, the burner operates in the Low-High-Off mode. The burner starts at Low and goes to High after the 8. fl ame stabilization period. Flame is extinguished when the load is satisfi ed or a limit opens, and the burner is sent to post purge. ○ For High/Low control wiring (Figure 9A), if a high / low control has been wired between modulate between low and high as necessary to meet load demand until the load is satisfi ed or a limit opens, and the burner is sent to post purge. Load Satisfi ed – The fuel valves are closed. After a 15 second post purge, the burner switches to idle until the next call for operation. This operation sequence is typical and for reference only. The terminals RC1 and RC2 the burner starts at Low and is released to go to High after the fl ame stabilization period. It can repeatedly cycle between low and high as necessary to meet load demand until the load is satisfi ed or a limit opens, and the burner is sent to post purge. primary control could vary, depending on the customer specifi cation and code requirements. For the specifi c operating sequence that applies to your installation, consult the appliance manufacturer's directions, wiring instructions, and control manufacturer's literature supplied with your burner. Figure 9A - Typical Wiring Using Model RM7897C for High/Low Control (For Reference Only) CG15, CG25, CG50 Burner Manual 15 Section: Sequence of Operation Figure 9B - Typical Wiring Using Model RM7840L for Modulating Control (For Reference Only) 16 Prepare the Burner for Section: Prepare the Burner for Start-up 2. Gas Supply Piping ○ Start-up ○ Professional Installation and Service Required ○ Insure that the gas piping is properly sized and has been inspected by the gas utility, leak tested at all joints, and purged. To protect the gas train and controls, insure that a drip leg or dirt pocket has been properly installed. Insure that the fuel gas being supplied is compatible Incorrect installation and mishandling of start up could lead to equipment malfunction and result in asphyxiation, explosion or fi re. ○ ⮹ This burner must be installed and prepared for start up by a qualifi ed service technician who is trained ○ and experienced in commercial gas burner system installation and operation. ⮹ Carefully follow the wiring diagrams, control with the burner specifi cation and is available at the correct regulated pressure. (See burner name plate and specifi cation sheets). Insure that the vent lines for the diaphragm valves have been run to the outside and properly terminated. Use RWB recommended maximum pipe lengths for good light-off (Figure 8A/B). instruction sheets, fl ame safeguard sequence 3. Electrical of operation, test procedures and all appliance ○ manufacturer's directions that pertain to this installation. If any of these items are not clear or are unavailable, ⮹ ○ call Beckett at 1-800-645-2876 for assistance. Delayed Ignition, Explosion Insure that all wiring has been completed and complies with the National Electric Code NFPA 70 and local requirements. Refer to Figure 1 and verify that the electrical supply to the burner matches the voltage specifi cation on the label. and Fire Hazards 4. Boiler or Appliance This is a direct spark ignition burner and ○ by code requirements must have a primary control with a 4-second fl ame establishment period. Exceeding 4 seconds could result in ○ delayed ignition, explosions and fi re. ○ Always verify the primary control has a 4-second fl ame ○ establishment period by carefully following the control manufacturers' confi guration instructions. ○ Example: Honeywell RM Series requires clipping and removing the JR1 resistor. Insure that the fl ue passages and combustion area have been thoroughly cleaned and are in good condition. Set the breech damper to the required position for system operation. Fill the appliance with water (boilers). Check all safety and operating controls for correct application, installation, wiring, and operation. Insure that the maximum capacity of the appliance is compatible with the specifi ed burner input fi ring rate. Start-up Checklist Verify the following before attempting to start 5. Burner - See Replacement Parts Illustration for Familiarization the burner. 1. General ○ Insure that the gas burner model and capacity meet the requirements for the installation. ○ Insure that the gas train meets operating ○ Carefully read and become familiar with the manual, fl ame safeguard control instructions, sequence of ○ operation, pertinent wiring diagrams, gas system layout, insurance requirements, other controls and valve literature pertinent to the installation. ○ ○ Follow the appliance manufacturer's start-up procedures (when available). ○ Inspect the combustion air supply and exhaust venting and verify that they are free of obstructions ○ and installed and sized in accordance with all applicable codes. ○ Notify appropriate personnel to schedule start-up (gas utility, owner, operators, subcontractors, etc.). ○ specifi cations, all safety codes and insurance requirements. Refer to Table 3 and Figures 10A and 10B to insure that the burner air damper is positioned for initial start-up preliminary settings. Insure that the burner is securely mounted in the appliance with the pressure fi ring plate and all gaskets in place for pressurized chamber applications. For propane-fi ring burners, insure that the propane restrictor has been correctly selected for your burner model (see Table 4) and properly installed (see Propane Restrictor Installation instructions). Before operating insure that all protective cover CG15, CG25, CG50 Burner Manual 17 Section: Start the Burner plates, enclosures and guards are in place and securely fastened. Burner Start Procedure When available, refer to the appliance ○ manufacturer's instructions and install the burner accordingly. (Before proceeding, turn off and lock out electrical power and close the main leak test cock to shut off gas to the burner.) 6. Test Instruments 1. With the power and main gas supply to the burner turned off, make sure gas has not accumulated in The following calibrated test equipment is required ○ to properly install the appliance. Whether these are 2. included in one kit or are individual test components, they should be calibrated and in good working order. A combustion analyzer capable of measuring ○ oxygen (or carbon dioxide), carbon monoxide, stack temperature, ambient temperature, and appliance effi ciency. Electrical multi-meter capable of measuring voltage, ○ 3. ohms, amps, and DC micro-ammeter for measuring the fl ame signal. These could be included in one meter or separate meters, but should be calibrated and accurate. Calibrated manometers and gauges capable of ○ 4. measuring all pressure ranges in the gas supply and appliance draft. This could typically range from a few psi to 0.01" W. C. ○ Having several manometers or U tubes with the correct range can simplify the testing and set up procedures. 5. the boiler or fl ues. Check the initial air settings for the input fi ring rate. Check the manufacturer's settings either on the nameplate shown in Figure 1 or listed in Table 3. If adjustment is necessary refer to Figures 10A & 10B and set the damper motor cam so that the indicator points to the values shown on the nameplate or listed in Table 3. With the main gas supply valve closed. Set the limit or controller to call for heat then apply power to start the burner. Reset the high and low gas pressure switches if necessary. In order to check the function of each component (i.e: fl ame safeguard sequence, airfl ow proving switch, ignition transformer, gas valves, safety lockout timing, etc.), with the gas supply closed off, monitor a complete burner run sequence. Note that the fl ame safeguard control will lock out since the fuel supply has been closed off. If component operation sequence and function is correct, reset the fl ame safeguard and initiate a new cycle. Monitor the start-up cycle and manually Start the Burner Professional Installation and Service Required Incorrect installation and mishandling of start up could lead to equipment malfunction and result in asphyxiation, explosion or fi re. open the main leak test cock as soon as the fl ame safeguard powers the safety shutoff valves. If the boiler room is quiet you may be able to hear the valve open, if not you can generally place your hand on the valve and feel it open. After you have observed main fl ame for a brief time, trip any of the switches in the limit string to shut the burner down. Monitor the fl ame and safety shutoff valves to assure that shutdown is controlled by the valves and that they operate properly. With this test passed you may safely initiate ⮹ This burner must be installed and prepared for start up by a qualifi ed service technician who is trained and experienced in commercial gas burner system installation and operation. ⮹ Do not attempt to start the burner unless you are fully qualifi ed. ⮹ Do not continue with this procedure until all items in the 'Prepare the Burner for Start-up' section have been verifi ed. ⮹ Carefully follow the wiring diagrams, control instruction sheets, fl ame safeguard sequence of operation, test procedures and all appliance manufacturer's directions that pertain to this installation. automatic start-ups on subsequent cycles. Initial Air Settings If your burner was built for a specifi c OEM (Original Equipment Manufacturer) application, the "Mfr's Settings" label (see Figure 1) will indicate the application and the initial air settings made at Beckett. Please verify those settings using the following procedure. If your burner was not built for a specifi ed application, the following steps outline the procedure for initially setting the damper (these settings may be different from settings specifi c to a particular OEM). Refer to Figure 10A and 10B for this procedure. If any of these items are not clear or are unavailable, ⮹ 1. call Beckett at 1-800-645-2876 for assistance. Remove the cover screw (A) then the cover (B) and set aside. 18 Push in on pin (G) to disengage the motor from the 2. damper shaft and cam stack. Rotate the damper shaft by hand to place the adjustment cams in a position where their adjustment scale can be easily seen. Release pin (G) to secure the damper shaft and cam stack to the motor. Using the wrench (C) supplied with the damper 3. motor, adjust the blue low fi re cam (D) to the initial setting listed in Table 3. Using the same wrench, adjust the red high fi re 4. cam (H) to the initial settings listed in Table 3. To adjust the high fi re transition, use a small straight 5. edge screwdriver. For high/low fi ring burners, turn the white adjustment screw located in the orange transition cam (J) until the cam indicator is half way between the high and low settings on the scale. For modulating burners the orange transition cam is not used. After setting all the cams, make sure the damper 6. shaft and cam stack is set between its low fi re setting and its high fi re setting. (If you don't it may not move when it is powered.) Push in pin (G), move the damper by hand so that notch (E) is between the low fi re setting and high fi re setting on scale (F), then release pin (G) to re-engage the motor. When the motor is powered it will go to its low fi re setting. 7. This initial setting should be adequate for starting the burner at low fi re. Once the burner is in operation, the air setting will be adjusted for best performance as discussed later in this manual. Don't forget to re-install the cover after all adjustments have been made. The damper plate is attached by screws to its shaft, and bears Section: Start the Burner Figure 10A - Damper Motor with Cover B A Figure 10B - Damper Motor with Cover Removed C G F E against a fl at on the shaft for alignment. The shaft is secured to the damper motor by a sleeve coupling with two setscrews bearing against the damper shaft and two more against the motor shaft. The motor shaft has a fl at matching the one on the damper shaft. The fl ats on the damper shaft and the motor shaft should be aligned so that the position indicator in the damper motor reads accurately. The best way to align the fl ats is to tighten the setscrews that bear against the fl ats on the shafts fi rst, and then tighten the ones that bear against the J D H Legend (Figures 10A & 10B) round surface of the shafts afterward. The test for proper alignment is to disengage the damper motor from its shaft using the disengaging pin (Item G in Figure 10B) and rotate the damper plate to its full closed position. The position indicator should point to 0° within +/- 5° tolerance. A - Cover screw B - Cover C - Wrench D - Low fi re cam (blue) E - Cam notch F - Damper motor scale G - Disengaging pin H - High fi re cam (red) J - Transition cam (orange) CG15, CG25, CG50 Burner Manual 19 Section: Start the Burner Optional Modulation Linkage Adjustment Instructions The optional modulation linkage assembly has been designed as an economic means to adjust the damper and the butterfl y valve to maintain air to gas ratios. When the optional Modulation linkage assembly is supplied with the burner, initial adjustments will be made at the factory. To ensure optimum operation, minor additional adjustments must be made after the burner is fi red on a boiler. The following adjustment will be pre-set at the factory, but may require minor adjustment at start-up: Figure 12 - Modulation Assembly for Left Handed Gas Entry (Standard Construction) ○ The damper motor high fi re and low fi re cams will be preset. ○ The linkage between the damper and the butterfl y valve will be preset as illustrated in the manual. ○ The butterfl y valve shaft will be set to a nominal position. Figure 11 - Modulation Assembly for Right Handed Gas Entry (Optional Construction) Adjustment Procedure Referring to the appliance manufacturer's literature, insure that all preliminary adjustments and calibrations required for the burner and appliance have been performed. A) Prior to starting the burner 1. Verify that the damper motor high fi re and low fi re cam settings match the nameplate (Figure 1) or Table 3. Examine the linkage for signs of damage. 2. Referring to the illustrations in Figures 11 or 12, 3. verify that the linkage is installed as shown. Prior to adjusting the burner, have available all the 4. necessary test equipment. A manometer to check pressures downstream ○ of the gas pressure regulator; at the manifold pressure test connection and in the furnace A draft gauge to check breaching pressure ○ A fl ue gas analyzer that can measure O2 (or ○ CO2) and CO. Adjust the gas pressure regulator to about ½" WC 5. higher than the anticipated high fi re gas pressure (see Table 3). To prevent the burner from modulating to high fi re, 6. set the modulation controller to the manual control mode. If necessary, refer to the manual supplied with the modulation controller. 20 Section: Start the Burner Table 3 - Initial Burner Settings for Both Propane & Natural Gas Furnace Pressure at High Fire 0" W.C. 0.25" W.C. 0.50" W.C. 1.00" W.C. H B M e t a R e r i F h g i H CG15 H B M e ta R e r i F w o L l e do M r e n r u B , e r u s s e r P s a G e r i F w o L C W hc n i g n it te S r e p m a D e r i F w o L , e r u s s e r P s a G e r i F h gi H C W hc n i r e p m a D e r i F h gi H g n i tt e S , e r u s s e r P s a G e r i F w o L C W hc n i g n it te S r e p m a D e r i F w o L , e r u s s e r P s a G e r i F h gi H C W hc n i r e p m a D e r i F h gi H g n i tt e S , e r u s s e r P s a G e r i F w o L C W hc n i g n it te S r e p m a D e r i F w o L , e r u s s e r P s a G e r i F h gi H C W hc n i r e p m a D e r i F h gi H g n i tt e S , e r u s s e r P s a G e r i F w o L C W hc n i g n it te S r e p m a D e r i F w o L , e r u s s e r P s a G e r i F h gi H C W hc n i r e p m a D e r i F h gi H g n i tt e S 800 468 CG15.1S 0.9 9 2.7 25 1.0 9 2.9 26 1.1 9 3.2 27 1.3 10 3.7 31 900 468 CG15.1S 0.9 9 3.4 32 1.0 9 3.7 34 1.1 9 3.9 37 1.2 10 4.4 43 950 548 CG15.2S 0.9 12 2.6 30 0.9 13 2.9 33 1.0 13 3.1 36 1.2 14 3.6 42 1050 548 CG15.2S 0.9 12 3.2 38 0.9 13 3.4 48 1.0 13 3.7 58 1.1 14 4.2 84 1150 641 CG15.3S 0.9 16 2.8 42 0.9 17 3.1 49 1.0 17 3.3 56 1.2 19 3.8 74 1250 641 CG15.3S 0.9 16 3.3 52 0.9 17 3.6 68 1.0 17 3.8 85 - - - - 1300 750 CG15.4S 0.9 20 2.7 51 1.0 21 2.9 66 1.0 22 3.2 80 - - - - 1400 750 CG15.4S 0.9 20 3.1 66 1.0 21 3.3 100 - - - - - - - - CG25 1350 669 CG25.1S 0.7 17 2.7 38 0.7 17 3.0 38 0.8 17 3.2 39 0.9 18 3.7 41 1450 669 CG25.1S 0.7 17 3.1 41 0.7 17 3.4 41 0.8 17 3.6 42 0.9 18 4.1 41 1550 774 CG25.2S 0.7 20 2.7 41 0.7 20 2.9 42 0.8 21 3.2 43 0.9 23 3.7 46 1700 774 CG25.2S 0.7 20 3.2 48 0.7 20 3.4 49 0.8 21 3.7 51 0.9 23 4.2 56 1800 896 CG25.3S 0.7 23 2.7 54 0.7 23 2.9 55 0.8 24 3.2 56 0.9 26 3.7 60 2000 896 CG25.3S 0.7 23 3.3 66 0.7 23 3.6 68 0.8 24 3.8 70 0.9 26 4.3 78 2100 1037 CG25.4S 0.7 27 2.8 66 0.7 27 3.1 71 0.8 28 3.3 76 0.9 30 3.8 90 2300 1037 CG25.4S 0.7 27 3.4 84 0.7 27 3.6 93 0.8 28 3.9 102 - - - - 2400 1200 CG25.5S 0.6 30 2.5 85 0.7 30 2.8 100 0.8 31 3.0 115 - - - - 2500 1200 CG25.5S 0.6 30 3.0 100 0.7 30 3.2 115 - - - - - - - - CG50 2000 888 CG50.1S 0.5 7 2.4 20 0.5 7 2.6 20 0.6 7 2.9 21 0.7 8 3.4 23 2200 888 CG50.1S 0.5 7 3.1 22 0.5 7 3.3 23 0.6 7 3.6 24 0.7 8 4.1 26 2400 1044 CG50.2S 0.5 8 2.5 23 0.5 8 2.8 24 0.6 9 3.0 25 0.7 10 3.5 28 2700 1044 CG50.2S 0.5 8 3.2 28 0.5 8 3.5 29 0.6 9 3.7 30 0.6 10 4.2 34 2900 1228 CG50.3S 0.5 9 2.6 27 0.5 9 2.9 28 0.6 10 3.1 29 0.6 11 3.6 33 3200 1228 CG50.3S 0.5 9 3.2 31 0.5 9 3.5 33 0.6 10 3.7 35 0.6 11 4.2 41 3400 1443 CG50.4S 0.5 11 2.7 33 0.5 11 2.9 35 0.6 12 3.2 37 0.7 13 3.7 42 3800 1443 CG50.4S 0.5 11 3.3 44 0.5 11 3.6 46 0.6 12 3.8 48 0.6 13 4.3 54 4000 1700 CG50.5S 0.5 13 2.7 50 0.5 13 3.0 52 0.6 14 3.2 54 0.7 17 3.7 60 4500 1700 CG50.5S 0.5 13 3.5 70 0.5 13 3.7 76 0.6 14 4.0 82 0.6 17 4.5 96 4800 1700 CG50.5S 0.5 13 4.0 98 0.5 13 4.2 115 - - - - - - - - Gas pressures are as measured at the manifold test connection. Notice: The settings in this chart are for reference only. The actual conditions at the installation may require further adjustment by the fully qualifi ed and experienced start-up technician. Notice: The light-off rate must not be set below the low fi re recommendation. Lower rates will lengthen the time it takes for gas to get to the burner head and may cause ignition failures. CG15, CG25, CG50 Burner Manual 21 Section: Start the BurnerModulation Control Figure 13A - Display Meaning Figure 13C - Manual Operation Operation in manual mode: ACTUAL VALUE (CURRENT OPERATION) SET POINT VALUE BURNER RELEASED FOR OPERATION DAMPER CLOSING (MODULATE DOWN) DECREASE VALUE ○ ○ MANUAL OPERATION WHEN LIT DAMPER OPENING (MODULATE UP) INCREASE VALUE Once in Manual Mode, the damper motor can be driven from high to low using the up/down arrows. To return to the automatic mode, press and hold exit button for ten seconds. EXIT BUTTON PROGRAM BUTTON The damper motor can be driven from low to high or high to low by pressing the up and down arrows as shown in Figure 13C. Pressing EXIT for 10 seconds returns the controller to the automatic mode. Modulation of the burner's fi ring rate is accomplished by driving the damper motor in small increments to either increase or decrease rate in response to boiler demand. A pressure transducer (for steam boilers) or temperature sensor (for water boilers) senses boiler Figure 13D - Operation Set Point Setting operation set point: demand and communicates it to the controller. Display ○ and programming functions for the Siemens RWF40 controller are shown in Figure 13A with the controller in the basic display mode. ○ ○ ○ Figure 13B - Manual Mode Putting in manual mode: From the original display, press program button once. (User level) Set point 1 is displayed. Use up/down arrows to change setting. When fi nished, press exit. ○ Press and hold exit button for 10 seconds. ○ Manual operation light will illuminate. The operating set point can be changed as shown in Figure 13D. Pressing the PGM button accesses the User Level of the software, where this change is made. The up and down arrow buttons raise and lower the operating set point. Pressing EXIT returns the control to the Basic Display level and saves your changes. Programming functions within the software are used to match its settings to the connected hardware, and to adjust the control's response to unusual job site The damper motor can be manually operated for set up and service of the burner by placing the controller in the manual mode, as shown in Figure 13B. Press and hold the EXIT button for 10 seconds to enter the manual mode. The manual operation light will illuminate. requirements if necessary. A manual for the controller is provided with the burner to allow programming at that level. 22 B) At burner start-up - Note, as soon as the burner lights, be prepared to adjust the butterfl y valve to set the low fi re rate adjustment. Section: Start the Burner It is acceptable for a burner with linkage control of the fuel to show 2% variation in O2 through the range as long as O2 stays 1. Monitor the fl ame through the observation port. If it appears to be too rich (yellow-orange fl ame), move the butterfl y valve shaft slot setting toward a more vertical position. (This adjustment is made by turning the nut holding the spring-loaded swivel on the butterfl y valve arm. If insuffi cient adjustment is available by this method the butterfl y valve shaft can be repositioned in the arm. Care must be taken to make only small changes.) 2. Use a fl ue gas analyzer to check the fl ue gas above the target points. If the O2 drops below the target points it may lead to a CO problem. Moving the damper arm position on the damper shaft changes mid-range O2. Loosening the clamping screws and moving the swivel end of the arm downward increases midrange O2, upward decreases it. This change will affect the low fi re O2 setting, and you'll need to re-set it. Verify Input Firing Rate 3. 4. 5. 6. 7. 8. 9. 10. ratings for O2 and CO. Your target should be 4% O2 1. and CO should be well below 50 PPM. (Note that the CO is usually near 0 at 4% O2.) If the O2 and CO levels are not on target, turn the low fi re adjustment nut as required to meet the target listed in Step 2. Check the low fi re rate. Either clock the meter or 2. compare the manifold pressure drop to factory standards. Adjust the low fi re cam setting in the damper motor (if necessary refer to the Initial Air Setting procedure described previously) and 3. the butterfl y valve shaft slot position as described in Step 1. Refer to Step 2 in this procedure and double check the O2 and CO readings. When low fi re is set, use the modulation controller to manually step the burner up to its high fi re rate. Check fl ue gas O2 and CO. Your target should be 3% O2. CO should be well below 50 PPM, and is usually near 0 for that O2. Adjust the regulated gas pressure as required to meet the target. Check the high fi re rate and adjust the high fi re cam setting and regulated gas pressure as required to meet the target. (If necessary, refer to the Initial Air Setting procedure described previously.) Using the modulation controller, manually step the burner back down to low fi re and verify the O2 and CO ratings. If the high fi re adjustments were signifi cant they may have affected the low fi re settings as well. Refer to Step 4 in this procedure to make adjustments as necessary. Using the modulation controller, manually step the burner through its range, stopping at several points to check O2 and CO measurements. After you are satisfi ed with the modulation linkage adjustments secure all linkage fasteners and continue the start-up procedure. Clock the meter, correct for pressure and termperature to get SCFH and calculate the input fi ring rate. Compare the calculated rate to the specifi ed input for the boiler found on the specifi cation sheets and on the rating plates for the burner and boiler. Do not exceed the specifi ed maximum input for the boiler. Attach a manometer to the manifold test port, clock the meter, and adjust the regulated pressure until the specifi ed input level is achieved. Refer to Table 3. Be sure to set the breech or furnace pressure to the correct value, since this will have an effect on the manifold pressure. CG15, CG25, CG50 Burner Manual 23 Section: Start the Burner Estimating Rate Manifold to Furnace Pressure information can be used to estimate the burner's fi ring rate when it is not possible to clock a meter for the rate. To estimate the burner's fi ring rate: Temperature Correction Gas volume also changes with the temperature of the gas. Most gas meters are temperature compensated. They say so on the face of the index and don't require temperature correction. The temperature we correct to is 60° F. That's close to the temperature of the ground, ○ Measure the furnace pressure over fi re ○ Measure the manifold pressure (at the manifold so usually it's not necessary to correct for temperature from underground lines. pressure test connection). ○ ○ Subtract the furnace pressure from the manifold ○ pressure ○ Compare the result to the data in Figures 14A, 14B, ○ or 14C as appropriate for your burner. Measure the gas temperature at the meter. Add 460 to the gas temperature and divide 520 by the result to obtain the correction factor. Multiply the pressure corrected fl ow rate times the temperature correction factor. Clocking a Gas Meter Before you clock the meter you must make sure that the burner is operating at a steady rate, and that it is the only thing that is using gas that would fl ow through the meter. Uncorrected Flow Rate Example: The meter in the example is connected to an above ground line on a hot day and shows 100° F gas temperature. 460 + 100 = 560; 520 / 560 = 0.929; 465 x 0.929 = 432 CFH corrected for pressure and temperature. This fi gure is often called SCFH (for standard cubic feet per hour). BTU's and MBH Natural Gas ○ Locate the dial that moves the fastest and determine how many cubic feet are represented by one revolution of its dial. ○ Use your watch for timing and observe how many cubic feet are used in one minute. ○ Multiply by 60 The BTU content of natural gas varies from one location to another, and even from day to day at a fi xed location. For fi ring estimates it is usually assumed to be 1000 BTU's per standard cubic foot. To calculate BTU/Hr fi ring rates multiply SCFH times 1000. Example: The dial is a one cubic foot dial, and goes around 7 ½ times in one minute. That gives 7.5 cubic feet per minute. Multiply by 60 to get 450 cubic feet per hour (CFH) as your uncorrected fl ow rate. Pressure Correction Gas is compressible, the higher the pressure on it, the smaller the number of cubic feet it occupies. To correct for that you will need to know the gas pressure at the meter. Example: 432 SCFH x 1000 = 432,000 BTU/Hr. MBH stands for thousands of BTU's per hour. Since 1 cubic foot of natural gas contains 1000 BTU, 1 MBH equals 1 SCFH of gas fl ow. Example: 432 SCFH = 1,080 MBH LP (Liquifi ed Petroleum) Gas The BTU content of LP gas varies with the relative quantities of propane and butane in each delivery of gas and changes as liquid level in the tank falls. For fi ring estimates it is usually assumed to be 2,500 BTUs per standard cubic foot. If there's a gauge at the meter, read it while the gas ○ is fl owing. (If not, measure the gas pressure in the line downstream of the meter before any valves or regulators, with no gas fl owing.) Convert the gas pressure to PSI if you measure it in ○ any other units. (1 PSI = 27.7 inches water column) Add 14.7 to the meter pressure, divide their sum by ○ 14.7, and multiply that result times the uncorrected fl ow rate to obtain the pressure corrected fl ow rate. To calculate BTU/Hr fi ring rates multiply SCFH times 2,500. Example: 432 SCFH x 2500 = 1,080,000 BTU/Hr. MBH stands for thousands of BTU's per hour. Since 1 cubic foot of propane gas contains 2,500 BTU, 1 MBH equals 0.4 SCFH of gas fl ow. Example: 432 SCFH = 1,080 MBH Example: The meter in the example above is operating at 14" WC. 14 / 27.7 = 0.5 PSI at the gauge; 14.7 + 0.5 =15.2; 15.2 / 14.7 = 1.034 correction factor; 1.034 x 450 = 465 CFH corrected for pressure 24 Section: Start the Burner Figure 14A - Manifold to Furnace Pressure Drop vs Rate CG15 * 1800 1600 1400 1200 HCG15.4S B M , e ta R 1000 800 600 400 200 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 Pressure Drop, In. WC CG15.3S CG15.2S CG15.1S Figure 14B - Manifold to Furnace Pressure Drop vs Rate CG25* 3500 3000 2500 CG25.5S H B M , e ta R 2000 1500 1000 500 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 Pressure Drop, In. WC CG25.4S CG25.3S CG25.2S CG25.1S * Charts represent both natural and propane gas. CG15, CG25, CG50 Burner Manual 25 Section: Start the Burner Figure 14C - Manifold to Furnace Pressure Drop vs Rate CG50* 6000 5000 4000 H B CG50.5S CG50.4S M , e ta R 3000 2000 1000 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 Pressure Drop, In. WC CG50.3S CG50.2S CG50.1S * Charts represent both natural and propane gas. Check Operation and Safety Controls 2. Testing by Qualifi ed Technician Required. Failure to properly test and verify the correct function of operation and safety controls could lead to equipment malfunction and result in asphyxiation, explosion or fi re. 3. Operating control – Run the burner until the operating control shuts it off. If necessary, make adjustments to ensure the control cycles the burner in the desired temperature or pressure range. Operating controls should be set to minimize the number of fi ring cycles that the burner runs. High cycling rates increase the possibility of light-off lock outs. Low water cutoff (LWCO) – With the burner fi ring, ⮹ The testing of operation and safety controls requires technical training and experience with commercial gas burning systems. ⮹ Carefully follow the manufacturer's instructions supplied with the controls. ⮹ Verify the correct function of all operation and safety controls used in the installation. 4. ⮹ If instructions are not available, use the following recommended procedures and record all results in a start-up log. ⮹ Refer to Figure 7 for typical test points and component locations. 5. 1. High limit – To check the High Limit, raise the temperature or pressure of the operating control to a higher level and lower the limit to a setting less than the operating control. Run the burner until the high limit opens and shuts the burner off. Adjust the controls back to the desired settings. open the blow down valve on the low water cutoff, if applicable. As the water level drops, the LWCO switch contacts open and shut the burner off. When the water level rises, the LWCO contacts close and restart the burner. Monitor the LWCO switch operation in relation to the water level in the sight glass for synchronization. Airfl ow proving switch – With the burner fi ring at its lowest rate, loosen the tubing connection to the airfl ow proving switch. A loss in air pressure at the tubing should immediately cause the diaphragm in the switch to open and recycle or lockout the safeguard control. Low gas pressure switch – With the burner fi ring and a manometer attached to a test port near the low pressure switch, gradually close the main leak test cock to shut off the gas supply. Note the pressure at which the low gas pressure switch opens and shuts the burner off. Manually reset the switch. The low gas pressure switch should be set at half of the normal supply pressure in the line. 26 6. High gas pressure switch – With the burner fi ring and a manometer attached to the test port nearest the high pressure switch, gradually increase the gas pressure until the high pressure switch opens and shuts the burner off. Note the pressure and manually reset the switch. The high gas pressure switch should be set at one and one half times the high fi re manifold pressure (see nameplate data in Figure 1 or set switch as determined by testing). 7. Leak-test valve – With the burner fi ring and manometer attached to the leak-test valve port, turn the burner electrical switch off and observe that the gas pressure does not increase after several minutes. This proves total closure of the main gas valve. 8. Flame safeguard safety lockout – Simulate a fl ame failure by turning the main gas supply off. The control should shut the burner off on safety within the safety lockout time. 9. Flame sensor circuit (fl ame rod) – With the burner power switch turned off, refer to the wiring diagram supplied with the control and locate the Section: Start the Burner Oxygen – For both low fi re and high fi re it is recommended that you measure the oxygen (O2) early in the test sequence because high levels of carbon monoxide can be created at very low or even very high O2 levels. The typical operating range is between 2.5% – 4.5 %. The equivalent carbon dioxide (CO2) operating range is 9% – 10.5%. High excess air levels reduce the fl ame's UV output and the scanner signal that proves the burner is fi ring. Carbon monoxide (CO) – An operating range of 0 -50 PPM is recommended for the burner. The maximum carbon monoxide (CO) level permitted in the fl ue gas by the UL 795 Standard is 400 PPM (0.04%). Stack Temperature – The stack temperature should be within the range specifi ed by the appliance manufacturer. It is infl uenced by input fi ring rate, fl ame shape, excess air ratio, and cleanliness of boiler fl ue passages. This temperature, combined with the ambient temperature, and O2% (or CO2) is used in calculating the appliance effi ciency. Recommended Combustion Test Sequence 10. sensor connection terminals. Place DC voltmeter 1. probes in the fl ame amplifi er test jacks. With the burner fi ring, the fl ame signal should be steady and 2. at least 1.25 VDC. Flame sensor circuit (UV scanner) – With the burner power switch turned off, refer to the wiring 3. diagram supplied with the control and locate the sensor connection terminals. Place DC voltmeter probes in the fl ame amplifi er test jacks. With the 4. burner fi ring, the fl ame signal should be steady and at least 1.25 VDC. Adjust the draft or breech pressure to the appliance manufacturer's recommended level. Measure the carbon monoxide level and adjust air settings, if necessary, to regulate it to about 50 PPM for a starting point. Measure the O2 or CO2 at the 50 PPM CO level. For this discussion, assume the O2 is 1.5% (11% CO2). Open the air adjustment until the O2 level is increased by at least 1% or to 3% O2 (whichever is higher). This should reduce the CO level and provide a margin of reserve air to accommodate Use Test Instruments to Set Combustion 5. Verify that all boiler sections, canopy, and access plates or doors are fully equipped with gaskets and sealed 6. against any leakage, which could affect the combustion test results. Before making these tests, operate the burner for several minutes to allow the heating system temperature to stabilize or nearly reach steady-state 7. levels. Record all results in the start-up log for future reference. Draft – Set the breech or furnace pressure to the level specifi ed by the appliance manufacturer. Typical example: +0.10" W. C. Always use calibrated test instruments to set combustion levels. Verify that test instruments are calibrated and in good working condition. If not already provided, drill test access holes in the fl ue pipe near the breech (or upstream of the boiler breech damper, if applicable) and in the front mounting plate area for fi rebox pressure. Be careful not to damage any water-backed surface. variable conditions. Sample the CO level again. It should be in the 0 to 20 PPM range. Check the draft to ensure it still meets specifi cations. If a major change in draft is required, repeat the above steps. Perform any fi nal adjustments and lock the air settings securely. Run the burner through several cycles to verify prompt ignition and stable burner operation. CG15, CG25, CG50 Burner Manual 27 Section: Maintenance and Service Maintenance and Service 6. Annual Professional Service Required Tampering with or making incorrect 7. adjustments could lead to equipment malfunction and result in asphyxiation, explosion or fi re. 8. specifi cations are maintained (blower wheel hub to motor clearance should be .020"). Clean the inside surfaces of the burner housing scroll and especially the air intake area and airfl ow proving switch suction tube. If the blower motor does not have permanently lubricated bearings, oil the motor. Clear any debris from the air vents on the motor body. Clean the ignition transformer, baseplate, and ⮹ Do not tamper with the burner or controls or make any adjustments unless you are a trained and qualifi ed service technician. 9. ⮹ To ensure continued reliable operation, a qualifi ed service technician must service this burner annually. ⮹ More frequent service intervals may be required in 10. dusty or adverse environments. ⮹ Operation and adjustment of the burner requires technical training and skillful use of combustion test 11. instruments and other test equipment. Turn Off Electric and Gas 12. Supply Before Servicing terminal bushings. Inspect the ignition leads for signs of deterioration and loose terminals. If the burner fl ame detection is a UV scanner, inspect the mounting and clean the lens according to the component manufacturer's recommendations. Remove the gas gun assembly and clean the entire unit, paying special attention to the air diffuser and spuds. Inspect the fl ame rod (if used) for oxidation or distortion. Clean all surfaces, set the probe position, and insure that the fl ame rod is securely fastened. Refer to Figures 15A, and 15B. Inspect the ignition electrode for any damage. Clean all surfaces, set the proper electrode gap, Failure to turn off electric and gas supply could result in electrical shock, gas leakage, explosion, or 13. fi re hazards. and make sure it is securely fastened. Clean the inside of the air tube and inspect the combustion end for any deterioration. Referring ⮹ Turn main gas valves and electric power off before performing any maintenance. 14. ⮹ If a maintenance procedure requires electrical power, use extreme caution. to Figure 2, check the recess dimension from refractory. Inspect gas tube O-ring condition and replace if damaged. Install gas gun assembly back into the burner and use the jacking screw to tighten the gas gun securely in place. (Automotive chassis or Annual Maintenance 15. (The following should be performed by a qualifi ed service technician only.) 16. Burner: bearing grease is suitable for o-ring lubrication.) Inspect the condition of the appliance mounting plate and burner mounting fl ange gaskets and replace any damaged materials. See Figure 6. Inspect all burner control wiring and the burner control panel for damaged insulation and loose Run the burner and perform a complete combustion 1. test using the proper instruments before 17. proceeding. If necessary refer to the section labeled Start the Burner. Record the results for reference. Inspect and clean all dirt accumulation from the 2. terminals/connections. Verify that the source voltage to the burner and control panel is within 10% of the burner rating as listed on the nameplate. (Figure 1) gas train, burner exterior, burner air damper, and surrounding area. Remove the blower motor and clean any 3. accumulated matter from the blower wheel and motor end bell. Appliance (Follow appliance manufacturer's service procedures. The following steps are emphasized because they relate to burner operation) Clean all fl ue passages and fl ue pipe. Replace 4. 1. corroded or damaged pipes. Check wheel for damage and the hub setscrew for 5. tightness. If the blower wheel must be removed 2. from the motor shaft, insure that clearance Check the condition of the combustion chamber refractory, the front-plate insulation, and all gaskets and seals. Repair or replace as necessary Insure that the fl ue passages, fl ue vent pipes, and chimney fl ues are clean and unobstructed. 28 3. Check barometric damper or draft hood for proper operation. Section: Maintenance and Service Flame Safeguard 4. Inspect boiler sections and system load piping for possible leaks. Make all necessary repairs. 5. Check all operating and safety controls on the boiler for proper installation and operation. 6. Perform all maintenance and tests according to the burner control manufacturer's instructions (limits, controllers, low water cutoff, relief valves, feed Follow the control manufacturer's instructions and verify that the control is functioning to specifi cations. See Page 14 or 16 for appropriate sequence of operation and Items 8 through 10 on Page 28 for control system checks. Manual Shutdown for Long Periods valves, etc.) 1. Gas Supply Piping 2. 3. Inspect all piping for leakage and proper installation. Perform necessary repairs to comply with all codes. Close all gas valves in the gas supply piping system. Turn off all electrical power to the burner. Protect the burner and controls from moisture and dirt. Installation Area Ignition Reliability 1. 1. Insure that there are no combustible materials, fl ammable liquids or vapors in the vicinity of the 2. heating appliance. 3. 2. Verify that the combustion air supply is functioning 4. properly, adequately sized, clean, and properly 5. lubricated. 6. Examine ignition electrode inslators for cracks. Examine ignition wires for worn insulation. Examine ignition electrodes for wear. Check ignition transformer functionality. Verify that the head is centered in the airtube and that the head is not damaged. Check inlet pressure to the gas train SSOVs. Adjust the Burner for Proper Combustion 7. Follow the guidelines under Start the Burner to set the 8. combustion levels using test instruments. Figure 15A – Gas Gun Assembly (if used) Verify maximum recommended pipe lengths used in gas trains (Figure 8A/B) Verify low fi re light-off rate (Table 3) * Automotive chassis or bearing grease is satisfactory o-ring lubricant. CG15, CG25, CG50 Burner Manual 29 Section: Maintenance and Service Figure 15B – Gas Gun Assembly 3/8" Burner Head Adjustment - There is an optimum gas orifi ce size and burner head setting for each fi ring rate of the burner. The gas orifi ce size sets the gas fl ow velocity; the head setting establishes the airfl ow velocity. When those velocities are properly matched the burner provides its best performance and stability. The gas orifi ce size is built into the burner head. You can verify the correct selection by looking for the burner model number stamped on the top centerline of the stainless steel tube that forms the base of the burner head. It should match the model number on the Beckett burner data label on the blower housing. The head setting is established by a notched sleeve on the gas tube that can be rotated to positions on a scale marked by the burner's model number. The scale should normally be set to the model number on the Beckett burner data label. (If specifi c application requirements dictate an alternate head setting it will be noted by a label on the gun assembly.) For normal service requirements it is not necessary to disassemble the head from the gas tube. If you disassemble the gas gun, make sure that when you re-assemble it: 1. The adjustment scale is set to the correct position as indicated by the burner model number or Gun Label. 2. The alignment marks on the head, scale and stop are in alignment. 3. The O-ring between the head and the adjustment scale is in place, is lubricated with grease, and is compressed between the head and scale as the setscrews that retain the head are tightened. 30 Propane Restrictor Description Section: Maintenance and Service Installation The Beckett Propane Restrictor Conversion Kit allows for the conversion of CG15, CG25, and CG50 burners for use with propane gas. With the proper installation of the restrictor and attached O-ring, adjustments and settings for propane use will be the same as the adjustments and settings for natural gas use as detailed in the burner manual. This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction. (In Canada, in accordance with the requirements of the CAN/CGA-B149 Installation Code.) If the information in these instructions is not followed exactly, a fi re, explosion, or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualifi ed service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked, as specifi ed in the manufacturer's instructions supplied with the kit. Figure 16 – Propane Conversion Major Components B C Note that Steps 1 and 2 on the reverse side refer to fully assembled burners. Skip to Step 3 when converting a burner without the air tube assembly installed. Refer to Figures 16 and 17 when performing the following steps. CG15 is shown in the illustrations. CG25 and CG50 are similar. CG10 is similar with the exception of having the gas gun assembly mounted into the air tube instead of the housing. Figure 17 – Component Locations B E C H G E H G F D A F Major Component Key for Figure 16 & 17 A Air Tube E External Gas Manifold B Jacking Screw F Propane Restrictor C Internal Gas Tube G Restrictor O-ring D Burner Housing H Gas Tube O-ring CG15, CG25, CG50 Burner Manual 31 Section: Maintenance and Service Use authorized replacement parts only. Restrictors are precision machined parts and O-rings are rated for fuel contact. Do not attempt to replicate or modify any parts. Refer to Table 4. The gun assembly is secured inside the air tube by a spring-loaded jacking screw. It is spring loaded in order to control the force it can impose on the gun assembly. When installing the jacking screw look inside the air tube to verify that the pointed tip of the jacking screw pin is seated into the small slot on the locating pad on top of the gun. There is also an external verifi cation of correct assembly: when the screw is fully tightened, the e-clip on the top of the center pin should come fl ush with the top of the screw. Refer to Figure 18. Figure 18 – Gas Gun Installation Table 4 - Propane Restrictors Replacement Part Numbers Remove the jacking screw (B) from the housing to 1. free the internal gas tube (C). Gently rock the internal gas tube (C) to loosen the 2. tube from the burner housing (D). Burner Model Restrictor Part Number Restrictor Inside Diameter O-Ring Part Number Inspect the O-rings and insure that they are 3. properly lubricated. (A silicon O-ring lubricant is recommended, but automotive chassis or bearing grease is an acceptable substitute.) Referring to Figure 17, place the restrictor (F) 4. with pre-attached, pre-lubricated O-ring (G) into the internal gas tube (C). Use your hand to press the restrictor into the tube. The O-ring will hold the restrictor in place. Insure that the O-ring (H), attached to the outside 5. diameter of internal gas tube, is properly lubricated and seated against the fl ange on the internal gas tube. Install the internal gas tube (C) back into the 6. housing, refer to Figure 16. Fit the end of the tube into the external gas manifold (E). 7. Re-install the jacking screw (B). (Refer to the above notice for installation details.) 8. Fill out and place the supplied Conversion Data Plate adjacent to the rating plate. 9. Complete and attach the supplied Adjustment Data With the gas restrictor installed, as shown in Figures 16 & 17, CG15.1S 3246709U 0.532 3226401U CG15.2S 3246710U 0.576 3226401U CG15.3S 3246711U 0.623 3226401U CG15.4S 3246712U 0.677 3226401U CG25.1S 3246713U 0.712 3226402U CG25.2S 3246714U 0.742 3226402U CG25.3S 3246715U 0.796 3226402U CG25.4S 3246716U 0.833 3226402U CG25.5S 3246717U 0.889 3226402U CG50.1S 3246718U 0.925 3226403U CG50.2S 3246719U 0.980 3226403U CG50.3S 3246720U 1.031 3226403U CG50.4S 3246721U 1.103 3226403U CG50.5S 3246722U 1.150 3226403U all burner air adjustments and gas manifold pressure adjustments for propane will be approximately the same as the natural gas adjustments shown in the burner manual, or printed on the "Mfr's Settings" label on the burner housing. For a copy of the current burner manual go to http://www.beckettcorp.com/protect/tech.asp. If furtherTechnical assistance is required, call 800-645- 2876, Monday thru Friday, 8AM to 5PM EST. 32 For the Operator Inspect Heating System Regularly Lack of regular inspections and inadequate maintenance could lead to equipment malfunction and result in asphyxiation, explosion or fi re. Section: Maintenance and Service ⮹ (Always follow the appliance manufacturer's recommended service instructions, when available.) ⮹ The following checklist is intended to be used as a minimum reference guide only and does not supersede or replace the heating appliance manufacturer's recommended service and maintenance instructions or any code requirements. ⮹ Consult the installation and service instructions provided by the individual control or component manufacturer and carefully follow their directions. ⮹ Maintenance and testing may be required more frequently due to dusty or severe operating conditions. ⮹ If unusual or questionable performance is observed, shut the system down and contact your qualifi ed service agency immediately. Table 5 - Periodic Inspection Sheet Test/Inspection Frequency Comments Inspect area surrounding heating plant Daily Keep area clean and free of clutter Inspect gas supply system for leaks Daily Use visual and electronic leak detection Inspect appliance & piping for water leaks Daily Keep burner and controls dry at all times Inspect gauges, indicators, monitors Daily Note condition. Replace defective parts Check temperature and pressure levels Daily Compare to manufacturer's specifi cations Make visual inspection of fl ame Daily Look for changes in shape, size, and color. Monitor burner start-up Daily Verify prompt ignition and fl ame stability. Monitor stack temperature Daily Compare to start-up and trend level. Test low water cutoff and alarm Daily Follow control manufacturer's instructions & procedures in ASME Boiler & pressure vessel Code, Section VI - Recommended rules for care and operation of heating boilers. Calculate fuel gas input fi ring rate Weekly Compare to appliance manufacturer's Specifi cations Check fl ame safeguard sequence of operation. Weekly Follow control manufacturer's instructions Flame failure response & lockout timing. Weekly Follow control manufacturer's instructions Flame sensor signal level (if meter is hard wired) Weekly Compare to control manufacturer's specifi cations Main fuel gas valves Weekly Open high limit and verify cutoff operation Inspect exhaust vent system for blockage Weekly Remove any restrictions Inpect combustion air supply Monthly Remove any restrictions Check high and low gas pressure interlocks Monthly Follow control manufacturer's instructions Check safety valves As needed Follow control manufacturer's instructions & procedures in ASME Boiler & Pressure Vessel Code, Section VI - Recommended Rules for Care and Operation of Heating Boilers. CG15, CG25, CG50 Burner Manual 33 Replacement Parts For best performance specify genuine Beckett replacement parts. 1 2 3 5 4 8 7 6 9 12 15 1314 17 20 18 19 10 11 21 24 22 23 16 27 26 25 Note 1: See Burner Confi guration Table. 34 Item Description CG15 Part No. CG25 Part No. CG50 Part No. 1 Timer (if used) 21295U 21295U 21295U 2 Air Proving Switch 22181U 22181U 22182U 3 Ignition Transformer 7503U 7503U 7503U 4 Spring Latch (Dzus Fastener) 32444U 32444U 32444U 5 Sight Glass** 31346U 31346U 31346U 6 Rear Access Door* For UV For Flame Rod 5201303U 5201301U 5201304U 5201302U 5201304U 5201302U 7 Control Refer to UL Label for Model Numbers 8 Control Subbase Refer to UL Label for Model Numbers 9 UV Sensor (If Not Using Flame Rod) 7247U 7247U 7247U 10 Damper Motor Lo/Hi Modulation 750601U 750603U 750601U 750603U 750601U 750603U 11 Nylon Bushing 32294U 32294U 32294U 12 Air Tube Specify Model 13 Motor 115-208-203V 208-230/380-460V 575V 21401U 21638U 21735U 21402U 21499U 21734U 21527U 21547U 21733U 14 Mounting Flange N/A 31347U 31449U 15 Blower Wheel 21268U 21267U 21528U 16 Flame Rod 2191302U N/A N/A 17 Ground Electrode 2191106U 2191107U 2191108U 18 Head, Welded Assembly Specify Model 19 Cable, Flame Rod (If Used) Panel No Panel 5990480U 5990360U 5990480U 5990360U 5990480U 5990360U 20 O-ring Set (2 included) 3226402U 3226403U 3226404U 21 Gas Tube, Welded Assembly 5193202BKU 5193203BKU 5193204BKU 22 Restrictor O-ring (LP Only) 3226401U 3226402U 3226403U 23 Propane Restrictor (LP Only) See Table 4 24 Jacking Screw Assembly 5193402U 5193403U 5193403U 25 Ignition Electrode 2191206U 2191207U 2191208U 26 Clamp 4474U 4474U 4474U 27 Cable, Ignition Electrode 5990184U 5990184U 5990184U NS Low Gas Pressure Switch 2190902U 2190902U 2190902U NS High Gas Pressure Switch 2190903U 2190903U 2190903U * Includes Sight Glass, Label, Gaskets, and Fasteners **Includes Beckett Label and Window Gasket NS = Not Shown CG15, CG25, CG50 Burner Manual 35 Limited Warranty Information The R. W. BECKETT CORPORATION ("Beckett") warrants to persons who purchase its "Products" from Beckett for resale, or for incorporation into a product for resale ("Customers"), that its equipment is free from defects in material and workmanship. To qualify for warranty benefi ts, products must be installed by a qualifi ed service agency in full compliance with all codes and authorities having jurisdiction, and used within the tolerances of Beckett's defi ned product specifi cations. To review the complete warranty policy and duration of coverage for a specifi c product, or obtain a written copy of warranty form 61545, please choose one of the following options: 1. Visit our website at: www.beckettcorp.com/warranty 2. Email your request to: rwb-customer-service@beckettcorp.com Write to: R. W. Beckett Corporation, P. O. Box 1289, Elyria, OH 44036 3. NOTE: Beckett is not responsible for any labor cost for removal and replacement of equipment. THIS WARRANTY IS LIMITED TO THE PRECISE TERMS SET FORTH ABOVE, AND PROVIDES EXCLUSIVE REMEDIES EXPRESSLY IN LIEU OF ALL OTHER REMEDIES, AND IN PARTICULAR THERE SHALL BE EXCLUDED THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT WILL BECKETT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGE OF ANY NATURE. Beckett neither assumes, nor authorizes any person to assume for Beckett, any other liability or obligation in connection with the sale of this equipment. Beckett's liability and Customer's exclusive remedy is limited to the cost of the product. USA: P.O. Box 1289 ● Elyria, Ohio 44036 Canada: R.W. Beckett Canada, Ltd. ● Unit #3, 430 Laird Road ● Guelph, Ontario N1G 3X7 www.beckettcorp.com Part Number 6104 BCF50 R13, Printed in the U.S.A. 06/10
Đăng ký:
Đăng Nhận xét (Atom)
Black & Decker Black&Decker Vacuum NV4820CN, homeappliance
Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...
-
Download! BERNINA® www.berninausa.com What is BSR? The BERNINA® Stitch Regulator The revolutionary Bernina Stitch Regulator (BSR) all...
-
Download! Power Vent & Power Direct Vent Replacement Parts No. Part Name and Description Repair Parts Illustration Repair Part...
-
Download! Service Handbook RESIDENTIAL HYBRID ELECTRIC HEAT PUMP WATER HEATER FOR MODELS: HPE10260H045DV (60 GAL.) HPE10280H045DV (...
Không có nhận xét nào:
Đăng nhận xét