Thứ Ba, 21 tháng 9, 2021

Beckett CG10(A), homeappliance





Download!

Suggested Specification For Model CG10, CG10A & CG10B Beckett Gas Burners R.W. Beckett Corporation _________________________________________________________________________________________________________________________________________________________________________________________________________________ Mail: P.O. Box 1289, Elyria, OH 44036 | Ship: 38251 Center Ridge Rd., North Ridgeville, OH 44039 | Ph: (440)327-1060 | Fax: (440)327-1064 General Burner Description: Install __________ Beckett Model ________ Gas Burner forced draft flame retention power gas burners. Burners shall be capable of burning ______BTUs (natural gas or propane) with a specific gravity of ____(0.64 or 1.56). Gas Pressure supplied to the burner gas train connection shall be a minimum of _____ inches W.C. (PSIG) at full high rate and a maximum of _____ inches W.C. at static conditions. Each burner shall be listed by Underwriters Laboratories and shall bear the appropriate UL label. In addition to the UL requirements, all equipment and installation procedures will meet the requirements of CSD-1 (FM, Swiss RE). Each burner shall be designed and constructed as an integrated combustion system package. Burner Construction: Burner housing shall be of cast aluminum construction. The burner mounting flange must support the burner weight on the appliance independent of any support and shall be seal welded to the air tube. Burners shall be furnished with a stainless steel flame retention head, capable of withstanding temperatures up to 1400 degrees F. The combustion head assembly shall incorporate an air diffuser, gas spuds downstream of air diffuser and direct ignition electrodes. The combustion gun assembly shall be removable and have the ability to be set or replaced. Full access to the burner combustion gun assembly shall be available without removing the burner chassis from the appliance. Air required for combustion shall be supplied by a blower, mounted integral to the burner. The blower wheel shall be of a forward curved "squirrel Cage" design and shall be directly driven by a 1/3HP, 3450rpm, _____volt, 60Hertz, ____Phase motor. The burner shall be equipped with an SPDT differential air pressure switch interlocked and continuously monitored to prevent burner operation if there is insufficient combustion air. Ignition: The burner ignition system shall directly ignite the natural gas or propane fuel. The ignition spark shall be generated by a 6000 volt electronic igniter, and directed by porcelain insulated electrodes located on the combustion head assembly. Ignition shall occur only at a reduced firing rate, and only after the flame is proven shall full rate be actuated. Burner Control Panel: All control components shall be mounted and wired in a remote 12 x 16 panel. The panel shall incorporate an Easy Access cover and Power On and Fuel On indicating lights. All wiring for remote panel electrical components shall be factory pre-wired to a terminal strip within the control panel. A junction box pre-wired to the burner components shall be mounted on the burner. It shall have a terminal strip, which will match a terminal strip in the remote panel. Field wiring will be required between the burner mounted junction box and the remote control panel. Gas Train: The gas train shall consist of a manual shutoff cock, redundant gas valve and regulating gas valve. The gas train shall meet UL and CSD-1 requirements and include a manual reset low gas pressure switch and manual reset high gas pressure switch. Mode of Operation: On-Off with low fire start- The main gas supply shall be controlled by a diaphragm regulating gas valve. The air inlet control band and shutter shall be fixed at the optimum fuel/air ratio at the high fire position. Product Liability Insurance: The burner manufacturer will provide an insurance certificate documenting his current coverage of Product Liability Insurance with minimum coverage of $10,000,000. Burner Start up Information and Test Data: On completion of the burner system start up- the installing contractor will complete the attached "Burner Start Up and Test Data" form and deliver to the Specifying Engineer. Burner Start Up Information & Test Data Beckett Model ____________________ Serial Number_______________________ Job Location_____________________________________________________________ Start Up Date_____________ Company Name_________________ Technician Name________________ Type of Gas: NAT____ Propane____ Gas Pressure at Train Inlet Flame Signal Readings Draft @ Breech Burner off position ______w.c Low Fire _______DC volts High Fire _______DC volts High Fire_________w.c Gas Pressure Train Inlet O2 Net Stack Temperature Light-Off ________w.c Light-Off _______% High Fire ________w.c High Fire _______% High Fire _________degrees Gas Pressure at Burner CO Combustion Efficiency Light-Off ________w.c Light-Off _______% High Fire ________w.c High Fire _______% High Fire _________% Power Supply Input Rate BTU/HR Air Damper Settings Volts____ PH____ Hz____ Shutter___________ High Fire_______ Band___________ Control Settings: Operating Control Cut/Out Limit Control Cut/Out Setting Low/High Gas Pressure ____________________ ________________________ _________/___________ Operating Control Cut/In Setting Limit control Cut/In Setting _______________________ _______________________ Checked for Proper Operation YES NO Checked for Proper Operation YES NO Low water cut off Barometric Damper High water cut off Boiler Room combustion air Flame Safeguard control ignition failure All gas lines checked for leaks Flame Safeguard control main flame failure Gas lines and controls properly vented Burner air flow switch Other system components specify Notified___________________________ of the following system deficiencies__________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________

Không có nhận xét nào:

Đăng nhận xét

Black & Decker Black&Decker Vacuum NV4820CN, homeappliance

Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...