Thứ Hai, 20 tháng 9, 2021

BEA Wizard, homeappliance





Download!

FALCON DR / FALCON XL-DR USER'S GUIDE MOTION SENSORS FOR INDUSTRIAL DOORS FALCON DR: double relay / high mount • FALCON XL-DR: double relay / low mount TECHNICAL SPECIFICATION Technology : Microwave and microprocessor Transmitter frequency : 24.125 GHz Transmitter radiated power : <20 dBm EIRP Transmitter power density : < 5 mW/cm² Mounting height • FALCON DR : from 11.5' (3.5m) to 23' (7m) • FALCON XL-DR : from 6.5' (2m) to 11.5' (3.5m) Tilt angles : 0° to 180° in elevation Detection zone Hold time : 0.5s to 9s (adjustable) Temperature range : -22°F to +122°F (-30°C to +60°C) Degree of protection : IP65 Norm conformity : R&TTE 1999/5/EC EMC 89/336/EEC Dimensions : 4" (W) x 5" (D) x 3 ¾" (H) 102 mm (W) x 127 mm (D) x 96 mm (H) Weight : 0.88 lbs (0.4 kg) Material of housing : ABS and polycarbonate Material of bracket : Anodized aluminium • FALCON DR (mounting height of 5m) • FALCON XL-DR (mounting height of 2.5m) : 13' (W) x 16' (D) 4m (W) x 5m (D) : 13' (W) x 6.5' (D) 4m (W) x 2m (D) Length of cable : 33' (10m) Manual adjustment • Orientation of sensing field (mechanically) • Multiple functions (by push buttons) DESCRIPTION OF THE SENSOR INSTALLATION TIPS Detection mode : Motion Minimum speed : 2 in (5cm)/s (measured in the sensor axis) Supply voltage : 12V to 24V AC ±10% 12V to 24V DC +30% / -10% Mains frequency : 50 to 60 Hz Power consumption : < 2W (VA) Two Output relay (free of potential change-over contact) • Max. contact voltage : 42V AC • Max. contact current : 1A (resistive) • Max. switching power : 30W (DC) / 60VA (AC) Remote control adjustments • Sensitivity • Hold time • Detection mode • Pedestrian and parallel traffic rejection mode • Output configuration • Security Tranceiver module (planar antenna) Green LED Infrared Receiver Red LED 2 Push Buttons Microprocessor Terminal block The sensor must be firmly fastened to prevent from vibrating. The sensor must not be placed directly behind a panel or any kind of material. The sensor must not have any object likely to move or vibrate in its sensing field. The sensor must not have any fluorescent lighting in its sensing field. 75.5268.01 20070111 Page 1 of 7 OPENING AND CLOSING THE SENSOR BRACKET MOUNTING WIRING SENSOR DIMENSIONS AND MOUNTING • Loosen the retaining nut until the cable slides easily into the grommet ; • Partially unscrew the 2 front cover screws ; • Pull out the front cover with the 2 front cover screws. BROWN-GREEN Power supply YELLOW COM 1 WHITE NC 1 PINK NO 1 BLACK COM 2 RED NC 2 BLUE NO 2 Ceiling mounting Wall mounting 2.5 in • Connect the quick disconnect terminal block to the main electronic circuit ; • Slide the main electronic circuit into the 2 housing slot guides and pull the main cable gently at the same time ; • Gently push the front cover and make sure that the external housing is properly seated (front cover must be flush with housing). • Screw the 2 front cover screws and tighten the retaining nut. • Check that both locking collars are at the same position • Align the bracket slot to the locking collar guide as shown To insert or to remove the cable: • Unscrew the retaining nut • Pass the cable through the retaining nut and the grommet • Screw the retaining nut n i 5. 6 n i 6 5 in 6.25 in n i 6 n i 5 . 5 5 in 6.25 in n i 3 Bracket dimensions Note: The bold-type values give the minimum distance required to be able to fully adjust the sensor. 75.5268.01 20070111 Page 2 of 7 SENSING FIELD DIMENSIONS 3 6 FALCON (Mounting height: 16.5' (5m) 6 3 0 3 6 The sensing fields here on the left correspond to the 3 following adjustments: 6 6 3 0 3 6 3 3 6 6 The sensing fields here on the left correspond to the following adjustments: 9 12 15 18 21 9 12 15 18 21 H = 16.5 ft. S = 9 • Tilt angle: 15°, 30°, 45° • Sensitivity: 9 9 12 15 18 21 9 12 15 18 21 H = 16.5 ft. Angle = 30° • Tilt angle: 30° • Sensitivity: 9,6,3 FALCON (Mounting height: 11.5' (3.5 m) 6 3 0 3 6 The sensing fields here on 6 3 0 3 6 The sensing fields 3 6 9 12 15 18 21 3 6 9 12 15 18 21 H = 11.5 ft. S = 9 the left correspond to the following adjustments: • Tilt angle: 15°, 30°, 45° • Sensitivity: 9 3 6 9 12 15 H = 11.5 ft. Angle = 30° 3 6 9 12 15 here on the left correspond to the following adjustments: • Tilt angle: 30° • Sensitivity: 9,6,3 FALCON XL (Mounting height: 8' (2.5 m) 6 3 0 3 6 The sensing fields here on 6 3 0 3 6 The sensing fields 3 6 9 12 15 H = 8 ft. S = 9 3 6 9 12 15 the left correspond to the following adjustments: • Tilt angle: 15°, 30°, 45° • Sensitivity: 9 3 6 9 12 15 H = 8 ft. Angle = 30° 3 6 9 12 15 here on the left correspond to the following adjustments: • Tilt angle: 30° • Sensitivity: 9,6,3 LED SIGNAL • When the power is turned ON the red and green LED flash for a few seconds. • During a detection the red LED lights on. • During configuration the red LED flashes a number of times corresponding to the parameter being changed (see table). The green LED flashes a number of times corresponding to its setting. 75.5268.01 20070111 Page 3 of 7 CONFIGURATION WITH REMOTE CONTROL 1. DESCRIPTION OF THE INFRARED REMOTE CONTROL • Open the battery compartment at the back of the remote control ; • Insert two AAA batteries supplied with the remote control as shown beside ; • Close the battery compartment. (10) Not used 0-9 Number keys (1) Output redirection (2) Plus (3) Unlock (4) Minus (5) Holdtime (6) Sensitivity (7) Detection mode (8) Rejection mode (9) 2. CONFIGURATION OF THE SENSOR (11) Not used (12) Not used (13) Not used (14) Not used (15) Check Values (16) Lock (17) Output configuration (18) Not used (19) Setup (20) Not used Note: For optimum results point the remote control to the sensor before pressing its buttons. Every adjustment session using the infrared remote control must start with unlocking and end with a double locking. The table below lists the parameters able to be adjusted by remote control and the operations required in order to adjust these parameters. PARAMETERS ACTIONS LED SIGNAL Press the UNLOCK key (4). Enter your 4-digit access code using 0-9 NUMBER keys (1). During the first sensor adjustment or if the access code is reset to the "0000" value (factory setting) or during the first minute after the power-on, press only the UNLOCK key (4) (no access code required). UNLOCK with access code UNLOCK without access code UNLOCK The red LED flashes quickly waiting for the LOCK When all the parameters have been set, press the LOCK key (16). access code. After entering the correct access code or if no access code is required, the red LED flashes slowly to indicate that the unlock is successful and the adjustment session has begun. Note: = Adjustment session ON The red LED stops flashing to return to its normal If you wish to enter a new access code, use 0-9 NUMBER keys (1) to enter the new 4-digit access code within 1 minute. If no access code is entered or if you want to keep the current access code, press the LOCK key (16) once more. If no remote control key is pressed within 1 minute, the adjustment session is automatically locked. function. LOCK with access code change LOCK without access code or access code change 75.5268.01 20070111 Page 4 of 7 Note: All parameters or functions listed in the following tables are only accessible if the sensor is in adjustment session. The red LED is then slowly flashing. During an adjustment session each parameter may be checked or changed at any time in the following way: PARAMETERS ACTIONS CHECK VALUES Press the key corresponding to the parameter to be checked and then press the CHECK VALUES key (15). Count the number of times the green LED flashes, which corresponds to the value of the checked parameter. No green LED flash corresponds to the value 0. Repeat this operation to check the value of the other parameters if required. Example: SENSITIVITY key (7) – 7 flashes of the LED: the radar sensitivity is set at the value 7. CHECK VALUES : PLUS Press the key corresponding to the sensitivity (7) or holdtime (6) parameter to be modified and then press the PLUS key (3) to increase the value by 1 unit. PLUS : MINUS Press the key corresponding to the sensitivity (7) or holdtime (6) parameter to be modified and then press the MINUS key (5) to reduce the value by 1 unit. MINUS : Note about LED signal: The red LED flashes quickly waiting for the value. Once this has been entered, it flashes slowly again. ACTIONS Press the SENSITIVITY key (7). Use the NUMBER keys 0-9 (1) to enter the sensitivity required (or adjust this parameter using the PLUS (3) or MINUS (5) keys as explained above) SENSITIVITY : Press the HOLD TIME key (6). Use the NUMBER keys 0-9 (1) to enter the required hold time (0.5 s to 9 s) (or adjust this parameter using the PLUS (3) or MINUS (5) keys as explained above). HOLD TIME : Press the DETECTION MODE key (8). Use the NUMBER keys 1-3 (1) to select the required mode : Key 1 : bidirectional mode Key 2 : unidirectional mode Key 3 : unidirectional mode with the MTF function DETECTION MODE : Press the REJECTION MODE key (8). Perturbations immunity is used to avoid detection due to environmental perturbations (vibrations, rains, etc). "Pedestrian/parallel traffic rejection" provides both rejection of pedestrian and rejection of any parallel traffic simultaneously. Use the NUMBER keys 1- 5 (1) to enter the required rejection mode : Key 1 : detection of all kind of targets in motion Key 2 : detection of all kind of targets in motion + perturbations immunity Key 3 : Low "Pedestrian/parallel traffic" rejection + perturbations immunity Key 4 : Mid "Pedestrian/parallel traffic" rejection + perturbations immunity Key 5 : High "Pedestrian/parallel traffic" rejection + perturbations immunity Press the OUTPUT REDIRECTION key (2) to switch from one mode to another. Key 0: regular operating mode (standard FALCON). Key 1: pedestrian or vehicle mode detection Any motion detected activates relay 1. Motion of vehicle triggers relay 2. PARAMETERS DEFINITIONS - ADVICES SENSITIVITY To increase the sensitivity means to increase the sensor capabilities to detect small useful signals. Practically, to increase the sensitivity leads to increase the dimensions of the sensing field. HOLD TIME The hold time allows extended output activation time after a DETECTION MODE REJECTION MODE OUTPUT REDIRECTION motion detection has stopped. It is recommended to use this parameter instead of the operator's one with the same function (interferences with the sensor) With the bidirectional mode, the approaching and departing target is detected. With the unidirectional mode, only the approaching target is detected. Using the MTF (Motion Tracking Feature) enables the sensor to automatically switch from the unidirectional mode to bidirectional mode as soon as a target is detected. This function is recommended for applications with elderly people or anyone approaching the door hesitantly. The discrimination between a pedestrian and the different vehicles depends mainly on the mounting height and the microwave module tilt angle. Be careful that the rejection function increases the response time of the sensor. Use the next table as suggestions and do not hesitate to increase or decrease the rejection level to obtain the required rejection. 23 ft 16.5 ft 11.5 ft 10 ft 7.5 ft Pedestrian or vehicle mode detection only works if pedestrian rejection is enabled (immunity parameter set to 3,4 or 5). Otherwise the sensor does not classify target types and as a consequence is never able to trigger relay 2. 75.5268.01 20070111 Page 5 of 7 OUTPUT REDIRECTION OUTPUT CONFIGURA TION Key 2: towards or away mode detection Motion towards the detector triggers relay 1. Motion away from the detector triggers relay 2. Press the OUTPUT CONFIGURATION key (17). Use the NUMBER keys 1-4 (1) to select the required output configuration : Active Passive Detection No Detection Towards or away mode detection only works if the detection parameter is set to 1 (bi-directional). Otherwise the sensor does not detect any motion anymore. This works also if pedestrian rejection is enabled (immunity parameter set to 3,4 or 5) During an adjustment session all parameters may be reset to their factory values in the following way : PARAMETERS ACTIONS FACTORY VALUES Press the SETUP key (19), then press the NUMBER key 9. All the parameters (except the access code) are reset to the factory values. FACTORY VALUES : Factory Values Table Parameter Values Factory setting Sensitivity 0 - 9 7 Hold time 0 - 9 0 Detection mode 1 - 3 2 Rejection mode 1 - 5 1 Output redirection 0 - 2 0 Output configuration 1 - 4 1 CONFIGURATION WITH PUSH BUTTONS Without remote control all of the parameters can be set using the 2 push buttons. Note: These two buttons are accessible from the sensor front cover with a small point. • To adjust the sensor using the buttons : Press and hold either push button for 2 seconds (until the LEDs flash) and then release the button ; • To end adjusting the sensor using the buttons : Press and hold either push button for 2 seconds (until the LEDs stop flashing) and then release the button; Note : if no button is pressed within 20 seconds the adjustment session is automatically ended. • To reset all the parameters to the factory values : Press and hold both push buttons simultaneously until the two LEDs switch on for 1 second (after 2 seconds). During the manual adjustment session the red and green LEDs flash successively and continuously. • The flashing number of the red LED provides the number of the displayed parameter (see next table); • The flashing number of the green LED provides the value of the displayed parameter ; Note: no green flashing indicates the zero value. During the manual adjustment session : • Each press on the right button increases the number of the displayed parameter by one unit ; • Each press on the left button increases the value of the displayed parameter by one unit. Note: When the maximum value or the highest number of the parameter is reached, it will return to its minimum values. For example, to change the sensitivity from 7 to 9 and the rejection mode from "detection of all kind of targets in motion" to High "Pedestrian/parallel traffic" rejection. • Press any button for 2 seconds to enter the adjustment session and then release it. • The red LED flashes once (1 = sensitivity) and the green LED flashes 7 times (sensitivity=7). • Press the left button twice to increase the sensitivity from 7 to 9. • The red LED still flashes once (1 = sensitivity) but the green LED flashes 9 times now (sensitivity=9). • Now press the right button 4 times to move to function 5 (rejection mode). • The red LED flashes 5 times (5 = rejection mode) and the green LED flashes once (detection of all kind of targets in motion) • Press the left button 4 times to set the parameter to High "Pedestrian/parallel traffic" rejection. • The red LED still flashes 5 times (5 = rejection mode) but the green LED flashes 5 times now (High "pedestrian/parallel traffic" rejection). • Press any button during 2 seconds to end the adjustment session and then release it. 75.5268.01 20070111 Page 6 of 7 TROUBLE SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION SHOOTING The door will not open and no red LED lights up. The sensor power is off. The sensor "sees" the door moving. When closing the door creates vibrations picked up by the sensor. Improper access code being entered. Batteries in the remote control are weak or installed improperly. Remote control is badly pointed. Check the wiring and the power supply. The door opens and closes Increase the tilt angle and/or reduce the sensitivity. constantly. Ensure that the sensor is correctly fixed. If the rejection mode is set at level 1, set this parameter to level 2. Reduce the sensitivity. Switch to unidirectional mode. The sensor will not unlock when access code is entered. The sensor does not respond to the remote control. COMPANY CONTACT Cut and restore power supply. No access code is required to unlock during the first minute after powering. Press on "unlock", then on "lock" and introduce a new access code. Check the batteries insertion. Change the batteries. Point the remote control towards to the sensor. Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call B.E.A., Inc. If you must wait for the following workday to call B.E.A., leave the door inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or gate for an incomplete solution. The following numbers can be called 24 hours a day, 7 days a week. For more information, visit www.beasensors.com. West: 1-888-419-2564 Mid-West: 1-888-308-8843 South-East: 1-800-407-4545 North-East: 1-866-836-1863 US and Canada: 1-866-249-7937 Canada: 1-866-836-1863 75.5268.01 20070111 Page 7 of 7

Không có nhận xét nào:

Đăng nhận xét

Black &amp; Decker Black&amp;Decker Vacuum NV4820CN, homeappliance

Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...