Thứ Sáu, 27 tháng 8, 2021

Aube Technologies Thermostat TH106, homeappliance





Download!

Temperature preset buttons Time and day TH106-A-347S4 User Guide Programmable Thermostat ■ Appears when the setpoint is displayed Set the day Temperature Set the time Program the Operating mode icons schedule Temperature Skip a period Select the operating mode Periods Temperature adjustment buttons preset icons Heating power indicator □ Connect the thermostat wires to the line wires and to the load wires using solderless connectors for copper wires. 2-wire installation ■ Description 1. This programmable thermostat can be used to control an electric heating system such as an electric baseboard heater, a radiant ceil ing, a radiant floor, a convector, etc. The thermostat cannot be used with the following: • a resistive load greater than 16.7 A • a resistive load less than 2 A • a system driven by a contactor or relay (inductive load) • a central heating system SUPPLIED PARTS: • One (1) thermostat • Two (2) 6-32 screws • Two (2) solderless connectors □ Installation 2. TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. THE INSTALLATION MUST BE PERFORMED BY AN ELECTRI CIAN. All cables and connections must conform to the local electrical code. Special CO/ALR solderless connectors must be used when con necting with aluminum conductors. Install the thermostat onto an electrical box. Install the thermostat about 5 feet high, on an inside wall facing the heater. Avoid locations where there are air drafts (such as the top of a staircase or an air outlet), dead air spots (such as behind a door), or direct sunlight. Do not install the thermostat on a wall that conceals chimney or stove pipes. The thermostat wires are not polarized; either wire can be con nected to the load or to the power supply. NOTE: Always keep the thermostat's vents clean and unobstructed. 4-wire installation 🞐 Push any excess wire back into the electrical box. ❑ Before installing the TH106 thermostat base, install provided adapter plate (U-shaped) on 347V electrical box which is bigger than regular electrical boxes. NOTE: If necessary, before re-installing the front component, config ure the thermostat (see section 3). ❒ Return power to heating system. TH106-A-347S4 400-106-011-A 22/1/07 1/3 🞐 Configuration 3. The configuration switches are on the back of the thermostat. The factory settings are indi cated by the gray cells in the following table. SW1 Early Start a Off On SW2 Temperature / time format b °C / 24-hour °F / 12-hour SW3 Cycle length c 15 seconds 15 minutes SW4 Not used - - a. Early Start can be used in Automatic mode only. When this func tion is enabled, the thermostat calculates the optimal time to start heating in order to obtain the desired temperature by the set time. The thermostat re-assesses the start time daily based on the pre vious day's performance. b. If you change the temperature display format, the preset temperatures ( , and ) will return to their default settings. c. 15-second cycles should be selected in most cases as it provides better temperature control. 15-minute cycles must be selected if you have a fan-equipped heater or if 15-second cycles causes light flickering (especially in rural regions). ❑ Power-up 4. Upon power-up, the thermostat is in manual mode ( ) and displays the actual (ambient) temperature. ■ Press the Hour and Min buttons to set the thermostat's clock. □ Press the Day button to set the day. ❒ Temperature Setting 5. Setpoint The thermostat normally displays the actual temperature. To view the setpoint, press the or button briefly. The setpoint will appear for the next 5 seconds. To change the setpoint, press the or button until the desired temperature is displayed. To scroll faster, hold the button. Using a preset temperature The thermostat has 3 preset temperatures: Comfort temperature Economy temperature Vacation temperature Icon Intended use Factory setting Comfort (when at home) 21°C (70°F) Economy (when asleep or away from home) 16.5°C (62°F) Vacation (during prolonged absence) 10°C (50°F) • To use the Comfort or Economy temperature, press the or button respectively. The corresponding icon will be displayed. • To use the Vacation temperature, press both and buttons simultaneously. The icon will be displayed. Storing a preset temperature To store the Comfort or Economy temperature: Set the desired temperature using the or button. Press and hold the appropriate button ( or ) for approximately 3 sec onds until the corresponding icon is displayed. To store the Vacation temperature: Set the desired temperature using the or button. Press and hold both and buttons simultaneously for approximately 3 seconds until the icon is displayed. ⬧ Operating Modes 6. Automatic - The temperature is set according to the programmed schedule. To place the thermostat in this mode, press Mode until is displayed. The icons of the current period and preset temperature are also displayed. Temporary Bypass: If you modify the setpoint (by pressing the , , or button) when the thermostat is in automatic mode, the new setpoint will be used until the end of the current period. When the next period starts, the temperature set for that period becomes the new setpoint. Manual - The programmed schedule is not used. The temperature must be set manually. To place the thermostat in this mode: ■ Press Mode until is displayed. □ Set the temperature using the , , or button. ⧫ Schedule 7.The schedule consists of 4 periods per day which represents a typi cal weekday. You can program the thermostat to skip the periods that do not apply to your situation. For example, you can skip periods 2 and 3 for the weekend. Period Description Associated temperature preset Wake Leave Return Sleep The Comfort ( ) temperature is used in periods 1 and 3 and the Economy ( ) temperature is used in periods 2 and 4. For example, when the period changes from 1 to 2, the setpoint automatically changes from Comfort setting ( ) to Economy setting ( ). You can have a different program for each day of the week; i.e., each period can start at different time for each day of the week. The thermostat has been programmed with the following schedule. Period Setting MO TU WE TH FR SA SU 6:00 AM 6:00 AM 6:00 AM 6:00 AM 6:00 AM 6:00 AM 6:00 AM 8:00 AM 8:00 AM 8:00 AM 8:00 AM 8:00 AM --:-- --:-- 6:00 PM 6:00 PM 6:00 PM 6:00 PM 6:00 PM --:-- --:-- 10:00 PM 10:00 PM 10:00 PM 10:00 PM 10:00 PM 10:00 PM 10:00 PM To modify the schedule: ■ Press Pgm to access the programming mode. Period 1 is selected. □ Press Day to select the day to program (hold for 3 seconds to select the entire week). 🞐 Press Hour and Min to set the start time of the selected period, or press Clear if you want to skip the period (--:-- is displayed). ❑ Press Pgm to select another period, or press Day to select another day. Then repeat step 3. TH106-A-347S4 400-106-011-A 22/1/07 2/3 ❒ Press Mode to exit the programming mode. NOTE: If no button is pressed for 60 seconds, the thermostat will automatically exit the programming mode. ◆ Power Outage 8. During a power outage, the settings are stored in memory. However, only the thermostat's clock must be re-adjusted if the power failure lasts more than 2 hours. When power comes back, the thermostat will return to the operating mode that was active prior to the power failure. ❖ Troubleshooting 9. PROBLEM SOLUTIONS Thermostat is hot. This condition is normal. Under normal operation, the thermostat housing can reach a temperature between 35°C (95°F) and 40°C (104°F). Wrong temperature is displayed. The thermostat is exposed to air draft. Eliminate the draft. The sticker on the thermostat's screen has not been removed. Wrong time is displayed. The thermostat was without power for more than 2 hours. Temperature does not change according to the programmed schedule. Check that the thermostat is in Automatic mode. Check the schedule and clock set tings. Display disappears and reappears after a few minutes. The thermal protection device on the heater is open. This can happen after a power failure or if the heater is obstructed by furniture or curtains. Display looks faded when heating is acti vated The heating system is less than the required minimum load. This thermostat cannot be used below that rating. ⬥ Technical Specifications 10. Power: 347 VAC, 50/60 Hz Minimum load: 700 W / 2 A (resistive only) Maximum load: 5800 W / 16.7 A (resistive only) Display range: 0°C to 60°C (32°F to 140°F) Display resolution: 0.5°C (1°F) Setpoint range: 5°C to 30°C (40°F to 86°F) Setpoint interval: 0.5°C (1°F) Storage: -20°C to 50°C (-4°F to 120°F) 🖴 Warranty 11. Aube warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube's option). If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or (ii) contact Aube. Aube will make the determination whether the product should be returned, or whether a replacement product can be sent to you. This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or mal function was caused by damage which occurred while the product was in the possession of a consumer. Aube's sole responsibility shall be to repair or replace the product within the terms stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCI DENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces and states do not allow the exclu sion or limitation of incidental or consequential damages, so this limi tation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some provinces and states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from province or state to another. Customer Assistance 12. If you have any questions about the product installation or operation, or concerning the warranty, contact us at: 705 Montrichard Saint-Jean-sur-Richelieu, Quebec J2X 5K8 Canada Tel.: (450) 358-4600 Toll-free: 1-800-831-AUBE Fax: (450) 358-4650 Email: aube.service@honeywell.com For more information on our products, go to www.aubetech.com As an ENERGY STAR® partner, Aube Technologies has determined that this product meets the ENERGY STAR guidelines for energy efficiency. TH106-A-347S4 400-106-011-A 22/1/07 3/3

Không có nhận xét nào:

Đăng nhận xét

Black & Decker Black&Decker Vacuum NV4820CN, homeappliance

Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...