Thứ Bảy, 28 tháng 8, 2021
Aube Technologies TH136, homeappliance
Download!
■ Installation 1. 1.1 Guidelines TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician. • For a new installation, choose a location about 5 ft. (1.5 m) above the floor. • The thermostat must be installed facing the heating system and on TH140-28 Installation and User Guide Electronic Programmable Thermostat 1.2 Thermostat Wiring NORTH AMERICA LOW VOLTAGE < 30 V: no polarity 120/240 V Connection to a circulator through an inside wall. • Avoid locations where there are air drafts (top of staircase, air out let), dead air spots (behind a door), direct sunlight or concealed chimneys or stove pipes. Relay Relay LINE VOLTAGE 120 to 240 VAC a 24 V relay 24 V transformer Connection to the thermostat terminals of a furnace Furnace ■ Loosen the captive screw holding the faceplate to the mounting plate. □ Pull the lower part of the faceplate to remove it from the mount ing plate. 🞐 Loosen the screw (captive) holding the wire cover and remove the wire cover. ❑ Pull wires through the hole in the mounting plate and secure the mounting plate to the wall (or onto an electrical box for line volt age wiring) using the enclosed wall anchors and screws. ❒ Wire the thermostat to the heating system (see section 1.2) and, if necessary, connect the remote input (see section 1.3). ⬧ Once wiring is complete, re-install the wire cover. ⧫ Use the switches located at the back of the faceplate to config ure your thermostat (see section 1.4) according to your applica tion. ◆ Install the batteries (see section 1.5). ❖ Mount the faceplate on the mounting plate and tighten the screw. Must be installed onto a certified electrical box. 2 A maximum load 120/240 V Connection to a circulator (pump) of a water heating system EUROPE For a 2-wire connection: no polarity 240 V Relay Furnace For a 3-wire connection: observe the polarity 240 V Power supply Load Provided wires Direct wiring to the circulator Connection to the thermostat terminals of a furnace Wiring to a power-operated mixing control valve TH140-28 400-140-000-C 2008-01-15 1/4 1.3 Remote Input Wiring The TH140 is equipped with a remote input which allows connection of a telephone controller (optional Aube CT240), a home automation system or any other remote control system. When a signal is received through this input, the TH140 will automatically switch from normal operating mode to Vacation mode, or vice versa when the sig nal is removed. 1.3.1 Connection to the CT240 Connect CT240 terminals A and C to TH140 terminals X and C. You must respect the polarity. For details on operating the telephone control ler, refer to the instruction manual. 1.3.2 Connection to a home automation system Heating Cycle Selection (switches #1 and #2) Select the cycle using switches #1 and #2. Short cycles help eliminate temperature variations, thus increasing user comfort. Since shorter cycles can lead to premature system wear, it is important to select the temperature control cycles appropriate to your heating system. In general, the bigger your heating unit is, the longer the cycles should be. Cycles EUROPE AMERICA Position 5 minutes Not recommended for furnaces Not recommended for central units 10 minutes Gas or electric wall furnace Radiant or convection electric heating 15 minutes Fuel or gas floor furnace, forced air heating Central heating 20 minutes Commercial unit Connect the TH140 to the home auto mation system as displayed in the wir ing diagram. 1.4 Configure the Thermostat Home automation system The switches are located on the back of the faceplate. Default set tings are highlighted. Switch Description UP DOWN 1 & 2 Cycles (proportional) 15 min (see 1.4.1) Span (conventional) 0.5°C (0.9°F) (see 1.4.2) 3 Clock display 12H 24H 4 Temperature display 1 °F °C 5 Temperature control mode Proportional (see 1.4.1) Conventional (see 1.4.2) 6 Pump protection 2 Deactivate Activate 1. If you change from °C to °F (or vice versa), you will need to reprogram your Comfort, Economy and Vacation settings. 2. For hot water installations, it is recommended to enable this option to acti vate the pump for one minute every 24 hours to prevent pump seizure. 1.4.1 Proportional Adaptive Mode (switch #5) This mode analyzes previous cycles to define the the next duty cycle. This control mode guarantees optimal temperature control based on the system's capacity. To extend the life of the system, a minimum On/Off time of 10% of the cycle has been implemented. For example with a 15-minute cycle, the system would not start or stop for less than 1.5 minutes. Ideal for: • Radiant or convection electrical heating system • Circulator control in a hot water system • Electrical hot-air furnace • Conventional gas or fuel hot-air furnace Not recommended for: • Gas or fuel furnace or boiler with a wall chimney having a 30-sec ond or higher combustion gas purging cycle. To figure out the gas purging cycle of your system, count the time between the heating command sent by the thermostat and the moment when the burner actually goes on. • Multi-zone systems, where several thermostats command a single heating unit. Note: In these last two cases, conventional mode with anticipation is recommended. 1.4.2 Conventional mode with anticipation (switch #5) This mode is compatible with all heating systems. Programmable Span Selection (switches #1 and #2) Select the span using switches #1 and #2. The default temperature span is 0.5°C (0.9°F). For example, if the temperature setpoint is 20°C (68°F), the heating system will turn on at 19.5°C (67.1°F) and turn off at 20.5°C (68.9°F). Span Hot Water Heating Forced Air Heating Position 0,3°C (0,5°F) Not recommended for furnaces Not recommended for central units 0,4°C (0,7°F) Gas or electric wall furnace Radiant or convection electric heating 1 0,5°C (0,9°F) Fuel or gas floor furnace Central heating 0,6°C (1,1°F) Commercial unit 1. 240 volt heating with relay (baseboard, convector, radiant ceiling, etc.) TH140-28 400-140-000-C 2008-01-15 2/4 1.5 Install the Batteries When you first install the batteries, the unit runs a sequence of tests and a complete reset to zero. The screen should display 0:00 MO and the ambient tem perature. The current setpoint is 20°C. The ambient temperature could be higher if you are holding the TH140 in your hands. It will return to normal about one 🞐 Select the Operating Mode 3. The TH140 offers three operating modes: 3.1 Automatic This mode executes the schedule. To activate: hour after installation. 1.5.1 Replacing the batteries The TH140 will display an icon indicating that the batteries must be replaced. This icon will be • Press Manual/Auto until is displayed. The program setpoint icon is displayed. 3.1.1 Temporary Bypass When in Automatic mode, you can temporarily bypass the displayed for 60 days; after this delay, the TH140 will shut down the heating unit. The time and programming are saved for 15 seconds when replacing the batteries. □ Basic Configuration 2. Note: You may program the thermostat while holding it in your hands or when it is mounted on the mounting plate. current program setpoint until the beginning of the next program. To bypass: • Set the desired temperature OR quickly press or to use a pre-defined setpoint. 3.2 Manual This mode allows you to maintain a constant temperature. To activate this mode: 2.1 Set the Time and Day ■ Set the time, using the Hour and Minute buttons. □ Set the day, using the Day button. 2.2 Configure the Setpoints 2.2.1 Comfort and Economy These setpoints are associated to the schedule's programs and are pre-programmed as follows: • Press Manual/Auto until is displayed. • Set temperature OR quickly press or to use a pre-defined setpoint. 3.3 Vacation Maintains a specific temperature when away for a pro longed absence (e.g. vacation). • From the TH140, quickly press to activate. • Can also be activated remotely (CT240, home automa tion system or any other system) if the remote input is connected to one of these systems. Comfort 20°C (68°F) Programs 1 and 3 Economy 18°C (64°F) Programs 2 and 4 2.2.2 Vacation This pre-programmed setpoint is used when the Vacation mode is activated. Vacation 10°C (50°F) 2.2.3 To Modify a Setpoint ■ Set the temperature using . Note: When the Vacation mode is activated remotely, it can only be deactivated remotely. Note: For details on how to activate the Vacation mode using a tele phone, refer to the CT240 Instruction Manual. ❑ Program Your Schedule 4.The TH140 allows four setting changes for each day of the week. There are no pre-set programs. Your heating system switches betw wen the Comfort setpoint and the Economy setpoint according to the □ Press and hold one of the setpoint buttons ( or or ) until the icon is displayed on the screen (approx. 3 seconds). 2.3 View the Current Setpoint To view the current setpoint, quickly press once one of the arrow buttons . The screen displays the setpoint; the arrow indicates a setpoint. times you would have set. For example, enter each day the time at which you wake up (PROG 1), the time you leave for work (PROG 2), the time you return home (PROG 3) and the time you go to bed (PROG 4): Programs Associated Setpoint Time PROG 1 (Comfort) Wake-up PROG 2 (Economy) Leave PROG 3 (Comfort) Return PROG 4 (Economy) Sleep Note: For temperature increases (PROG 1 and 3), allow at least 15 minutes per 1°C (2°F). For example, if you have lowered the temperature by 3°C (6°F) while you sleep and you wake up at 7 a.m., change the setting at 6:15 a.m. TH140-28 400-140-000-C 2008-01-15 3/4 4.1 Set or Modify the Programs • After 60 seconds of inactivity, the thermostat will automatically exit programming mode. • It is sometimes faster to program the same schedule for the entire week and then modify the exception days. ■ Press Program. The screen displays MO and PROG 1. □ Press Day to select the day (hold for 3 seconds to select all days of the week). 🞐 Press Hour and Minute to set the start time. To clear an entry, press Clear, the time zone displays --:-- when the program is inactive. ❑ Press Program to select the program number (2, 3 or 4). ❒ Repeat steps 3 and 4 for remaining programs. ⬧ Press Manual/Auto to exit. 4.1.1 Programming Example Comfort (programs 1 and 3): • Monday to Friday between 6:00 a.m. and 8:30 a.m. and between 4:00 p.m. and 11:00 p.m. • Saturday and Sunday between 6:00 a.m. and 11:00 p.m. Economy (programs 2 and 4): • Monday to Friday between 8:30 a.m. and 4:00 p.m. and between 11:00 p.m. and 6:00 a.m. • Saturday and Sunday between 11:00 p.m. and 6:00 a.m. PROG MON TUE WED THU FRI SAT SUN 1 6:00 6:00 6:00 6:00 6:00 6:00 6:00 2 8:30 8:30 8:30 8:30 8:30 --:-- --:-- 3 PM 4:00 PM 4:00 PM 4:00 PM 4:00 PM 4:00 --:-- --:-- 4 PM 11:00 PM 11:00 PM 11:00 PM 11:00 PM 11:00 PM 11:00 PM 11:00 To program this schedule: ■ Press Program. The screen displays MO and PROG 1. □ Press and hold Day for 3 seconds to select all days of the week (MOTUWETHFRSASU). 🞐 Set the time (6:00) for the first program (PROG 1) using the Hour and Minute buttons. ❑ Press Program to select PROG 2. Set the time (8:30) using the Hour and Minute buttons. ❒ Press Program to select PROG 3. Set the time (4:00 p.m.) using the Hour and Minute buttons. ⬧ Press Program to select PROG 4. Set the time (11:00 p.m.) using the Hour and Minute buttons. ❒ Technical Specifications 5. Power supply: 2 AA or LR6 alkaline batteries 1.5 V Max. resistive load: 5 A @ 240 VAC / 5 A @ 30 VDC Max. inductive load: 2 A @ 240 VAC / 2 A @ 30 VDC (P.F. = 0.4) Remote input: 12 VDC, ± 10%, 2.5 mA Certifications: CE, c UL us Control device: Electronic Automatic action: Type 1 B Number of programs: 4 programs / day, total of 28 programs Storage temperature: -20°C to 50°C (-4°F to 122°F) Operating temperature: 0°C to 50°C (32°F to 122°F), 95% R.H. Temperature setting range: 5°C to 30°C (40°F to 85°F) Temperature display resolution: 0.1 degree Temperature reading accuracy: ± 0.5°C (± 0.9°F) Software: Class A Protection class: II Protection degree: IP 40 The terminals are designed to handle a cross-section of wire measur ing up to 2.5 mm2 (14 AWG). 🖴 Warranty 6. Aube warrants this product, excluding battery (if applicable), to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube's option). If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or (ii) contact Aube. Aube will make the determination whether the product should be returned, or whether a replacement product can be sent to you. This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Aube's sole responsibility shall be to repair or replace the product within the terms stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces and states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WAR RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some provinces and states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from province or state to another. Technical Assistance 7. ⧫ Press Manual/Auto to exit. To erase programs 2 and 3 for Saturday and Sunday: ■ Press Program to access programming mode. □ Press Program until PROG 2 is selected. 🞐 Press Day to select SAturday (SA). ❑ Press Clear to erase the time (--:--). 705 Montrichard Saint-Jean-sur-Richelieu Québec, Canada J2X 5K8 Tel. : (450) 358-4600 1-800-831-AUBE Fax : (450) 358-4650 aube.service@honeywell.com 10 rue Ampère 95500 Gonesse France 33 (0) 1 34 07 99 00 33 (0) 1 34 07 99 19 advaube@comintes.com ❒ Press Day to select SUnday (SU). ⬧ Press Clear to erase the time (--:--). ⧫ Repeat steps 2 to 5 for PROG 3. ◆ Press Manual/Auto to exit. For more information on our products, visit us at www.aubetech.com TH140-28 400-140-000-C 2008-01-15 4/4
Đăng ký:
Đăng Nhận xét (Atom)
Black & Decker Black&Decker Vacuum NV4820CN, homeappliance
Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...
-
Download! BCM7255CN06EFM3.qxd 8/24/06 09:44 Page 1 Digital COOL MIST Humidifier MODEL BCM7255-CN HUMIDIFIER SAFETY PLEASE READ AN...
-
Download! BEFORE AFTER MODEL TH110A-DP-P B 240 VAC B B SUMMARY 60 HZ OPTIONS SELECTION B At the back of the thermostat...
-
Download! KV Push Owner's Manual BILLY GOAT KV VACUUM Owner's Manual KV600, KV650H, KV600FB, KV650HFB Accessories ON B...
Không có nhận xét nào:
Đăng nhận xét