Thứ Bảy, 28 tháng 8, 2021

Aube Technologies TH131-15S, homeappliance





Download!

Thank you for choosing the Aube TH132, a programma ble thermostat that provides both energy savings and total comfort. WARNING: This control module has 20-second cycles and must be installed ONLY with a TRIAC relay. 🖉 DAY/HOUR/MIN—Set the day and clock settings. ✂ PGM—Program the schedule (programs). ✁ MODE—Select the operating mode. RETURN—To exit a function. 👓 To configure temperature setpoints: Comfort, Economy and Vacation. 🕭 Adjust the floor temperature limit (AF only). 🕮 —Increase and decrease temperature. 🕯 —Indicates the number of the current program when Automatic mode is enabled. 🕿 Current operating mode (auto manual ). In Auto mode, the program's associated setpoint icon is also displayed ( ). ✆ Indicates the room OR floor temperature. 🖂 Heating indicators (see "Temperature Control" below). TH132-A This model has been designed to control a room's ambi ent temperature. The TH132-A has one temperature sensor located in the control module. TH132-AF This model is designed to use a floor sensor to control the room temperature. The TH132-AF has two temperature sensors: • The first one, installed in the control module, controls the ambient temperature. • The second one, installed in the floor (and connected to the power base), limits the temperature of the floor (the default setting of this limit is 82°F). TH132-F This model is designed to control floor heating systems. The TH132-F has one temperature sensor installed in the floor (sensor is connected to the power base). The TH132 has two switches, located on the upper-left part on the rear of the control module, which are used to set the following options: Early Start When the Early Start function is enabled (disabled by default), the TH132 calculates the optimum system start time to obtain the desired temperature by the set time. To enable this function: Position switch #1 down. Note: When this function is enabled, the system can be activated before the pro gram's start time. Temperature Display By default, the TH132 displays the temperature in °C. If you wish to change to °F: Position switch #2 up. Note: When you switch from °C to °F or vice versa, the , and setpoints must be redefined. ! " # & $ ! ! Align the bracket tabs on the control module with the holes located on top of the power base. This control module must be installed on a PB130-024T series power base. Note: Keep the thermostat's air vents clean and free from obstructions. On the first installation, the screen displays: 0:00, MO, and temperature (room/floor). For Floor Heating Installations: One of the two following messages may be dis played when a problem occurs: LO: The floor temperature is below 32°F (0°C), or the temperature sensor is defective, or not connected. The heating indicator is displayed and the relay is closed (energized). HI: The floor temperature is above 140°F (60°C), or the temperature sensor is defective. $ ! !% 🖉 Set the time (HOUR - MIN). ✂ Set the day (DAY). Comfort and Economy Setpoints These setpoints are associated with the schedule's pro grams (prog. 1 & 3 = Comfort, prog. 2 & 4 = Economy) and are preprogrammed as follows: A & AF models— 68°F, 64°F F model— 82°F, 68°F To modify a setpoint: 🖉 Set the temperature using and press and hold the or button until it is displayed on the screen. ✂ Press MODE/RETURN to exit. Vacation Setpoint The vacation setpoint is associated to the Vacation oper ating mode and is preprogrammed to 50°F. To modify this setpoint, repeat above steps. Floor Temperature Setpoint (AF model only) The floor temperature limit is preprogrammed to 82°F to avoid damage to your floor. The TH132 offers three operating modes: Automatic —Executes the schedule. 🖉 Press MODE to select . The current program number is displayed. You can temporarily bypass the current program by setting a specific temperature setpoint or by selecting one of the pre-defined setpoint buttons ( ). The new setpoint will be maintained until the beginning of the next program. Manual —Maintains a constant temperature. 🖉 Press MODE to select . ✂ Set temperature or select one of the pre defined setpoint buttons ( ). Vacation —Maintains the Vacation setpoint during a prolonged absence. Press . Note: The screw cannot be removed completely. If you remove the module from its base for more than 2 hours, the time and day will have to be reprogrammed. To modify, press the adjustment button (below ) using a pointed object, set the desired temperature using and press MODE/RETURN to exit. 400-132-012-A " !$ ' The schedule is used with the Automatic mode. The schedule controls the heating system to automatically Note: It is sometimes faster to program the same sched ule for the entire week and then to modify the exception days. ✁ Press PGM to select the program number (e.g. 1). Programming Example Programs MO TU WE TH FR SA SU 6:00 6:00 6:00 6:00 6:00 6:00 6:00 👓 Press PGM to select program 2. Set the time (8:30) using the HOUR and MIN buttons. 🕭 Repeat step 4 for remaining programs: program 3 (16:00) and program 4 (23:00). switch between the Comfort and Economy temperature setpoints at the times you have programmed. 👓 Press HOUR and MIN to set the start time. 🕭 Repeat steps 3 to 4 for remaining programs (e.g. 2, 3 8:30 8:30 8:30 8:30 8:30 --:-- 16:00 16:00 16:00 16:00 16:00 --:-- --:-- --:-- 🕮 When all programs are configured, press MODE/ RETURN to exit. The schedule consists of 4 programs per day defined as follows: Programs Setpoint Time i and 4). 🕮 Press MODE/RETURN to exit. 23:00 23:00 23:00 23:00 23:00 23:00 23:00 Comfort : To erase programs 2 and 3 for Saturday and Sunday Wake-up Leave home Back home Night Note: After 60 seconds of inactivity, the thermostat will automatically exit programming mode. To clear a program time: When you clear a program time entry, the TH132 will maintain the temperature setpoint of the last executed program until the beginning of the next program. • Monday to Friday, between 6:00 and 8:30 and between 16:00 and 23:00. • Saturday and Sunday, between 6:00 and 23:00. Economy : • Monday to Friday, between 8:30 and 16:00 and between 23:00 and 6:00. 🖉 Press PGM. ✂ Press PGM to select program 2. ✁ Press DAY to select SAturday (SA). 👓 Press CLEAR to erase the time (--:--). 🕭 Press DAY to select SUnday (SU). 🕮 Press CLEAR to erase the time (--:--). i. The programs' start time can be different for each day of the week. To enter the programs' start time To shorten programming, you simply have to enter the start time for each program. 🖉 Press PGM. ✂ Press DAY to select the day (hold for 3 seconds to select all days of the week). $ ! The TH132 thermostat works differently than conventional electromechanical thermostats. It is equipped with a proportional integral adaptive (PIA) controller which determines heating cycles by analyzing 🖉 Repeat steps 1 to 3 above. ✂ Press CLEAR to erase the time entry. The time por tion of the LCD indicates --:-- when the program is inactive. ✁ Press MODE/RETURN to exit. ! ! Model: TH132 A / AF / F Display range: 32°F to 140°F (0°C to 60°C) Setting range (ambient): 40°F to 86°F (5°C to 30°C) • Saturday and Sunday, between 23:00 and 6:00. To program this schedule 🖉 Press PGM. ✂ Press and hold DAY for 3 seconds to select all days of the week. ✁ Press PGM to select program 1. Set the time (6:00) using the HOUR and MIN buttons. (! ! % AUBE TECHNOLOGIES INC. TWO (2) YEAR LIMITED WARRANTY This product is guaranteed against workmanship defects for a two-year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or 🕯 Press PGM to select program 3. 🕿 Repeat steps 3 to 6. ✆ Press MODE/RETURN to exit. If you have any questions concerning the programming of the TH132 programmable thermostat, call our technical support team at: the temperature behavior history within the room. The PIA controller reduces temperature swings providing accurate temperature control while increasing user com fort. The controller determines the amount of power required by the heating system to maintain the setpoint tempera ture. When the heating system is activated, one of the following Setting range (floor): 40°F to 104°F (5°C to 40°C) Pre-programmed temperature setpoints: Comfort: A/AF: 68°F (20°C) and F: 82°F (28°C) Economy: A/AF: 64°F (18°C) and F: 68°F (20°C) Vacation: A/F/AF: 50°F (10°C) Floor limit: AF: 82°F (28°C) replace, at our option and without charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. 705 Montrichard Saint-Jean-sur-Richelieu Quebec, Canada J2X 5K8 Tel.: (450) 358-4600 Toll Free: 1-800-831-AUBE Fax: (450) 358-4650 Email: service@aubetech.com 10 rue Ampère 95500 Gonesse France 33 (0) 1 34 07 99 00 33 (0) 1 34 07 99 19 advaube@comintes.com icons is displayed: 1 to 20% 21 to 40% 41 to 60% 61 to 80% 81 to 100% Temperature resolution display scale: 0.1° Storage:-4°F to 120°F (-20°C to 50°C) Software: Class A Controller: Electronic Temperature control: Proportional integral adaptive, 20-second heating cycles Programming protection: Protected memory Clock protection: 2 hours Size (H/W/D): 3.3 x 3.1 x 0.5 in (83 x 79 x 13 mm) cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the nearest shipping address. For more information on our products, visit us at: www.aubetech.com As an ENERGY STAR® partner, Aube Technologies has determined that this product meets the ENERGY STAR guidelines for energy efficiency. 20/04/2004 400-132-012-A The PB130-024T power base is designed to power a TH13X Series control module. This low voltage power base can be used to drive a line voltage load using a relay or connect directly to equipment (such as a hot water system) using a 24 V signal. Although the PB130-024T is compatible with most relays, it has been optimized for use with an Aube relay. Aube offers triac relays (SSR) such as the RT850 and RT850T (with built-in 24 V transformer), and electromechanical relays such as the RC840 and RC840T (with built in 24 V transformer). Cut power to the heating system at the main power panel to avoid electrical shock. Installation should be carried out by an electrician. For a new installation, choose a location about 5 ft. (1.5 m) above the floor. The thermostat should be installed facing the heating system and on an inside wall. Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or con cealed chimneys or stove pipes. ■ One (1) PB130-024T low voltage power base □ Two (2) anchors 🞐 Two (2) mounting screws ■ Connect the base. See the typical wiring diagrams. a) Electric heating (figures 1, 2 and 3) • Connect the base to the relay: • Use a relay with a built-in 24 V transformer or • Use a relay and an external 24 V transformer. • Connect the relay to the load (see relay's instructions). b) Hot water heating (figure 4) • Connect the base to the 24 V valve of the water heating system. □ For a floor heating installation, connect the floor sensor between the S and R terminals. 🞐 Push the excess wire into the wall and secure the base using the provided screws and wall anchors. ❑ Before mounting the control module onto the base, select the heating cycle, set the switches (if necessary) and mount the control module. Refer to the control module's user guide for more information. ❒ Once the control module is configured (switches) and installed, Maximum load: 0.5 A / 24 VAC Operating temperature: 32°F to 122°F (0°C to 50°C) Storage: -4°F to 122°F (-20°C to 50°C) Size (H • W • D): 2.94 x 2.94 x 0.53 in. (74.6 x 74.6 x 13.3 mm) Wire gauge: 14 to 22 AWG return power to the heating system. If you have any questions concerning the PB130-024T low voltage power base, call our technical support team at: AUBE TECHNOLOGIES INC. TWO (2) YEAR LIMITED WARRANTY This product is guaranteed against workmanship defects for a two-year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. 705 Montrichard Saint-Jean-sur-Richelieu Quebec, Canada J2X 5K8 Tel.: (450) 358-4600 Toll Free: 1-800-831-AUBE Fax: (450) 358-4650 Email: service@aubetech.com 10 rue Ampère 95500 Gonesse France 33 (0) 1 34 07 99 00 33 (0) 1 34 07 99 19 advaube@comintes.com AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address. For more information on our products, visit us at: www.aubetech.com 14/11/2003 400-130-002-B

Không có nhận xét nào:

Đăng nhận xét

Black & Decker Black&Decker Vacuum NV4820CN, homeappliance

Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...