Thứ Sáu, 27 tháng 8, 2021
Aube Technologies TH115 A, homeappliance
Download!
■ Description 1. Aube's TH115 programmable thermostats have three temperature control modes: A mode: controls the ambient air temperature F mode: controls the floor temperature using an external temperature sensor AF mode: controls the ambient air temperature maintains the floor temperature within desired limits using an external temperature sensor On/Standby switch 1 TH115 A/F/AF User Guide Programmable Thermostat ❑ Clock and Day Setting 4. ■ Press the Hour button to set the hour. □ Set the Min button to set the minutes. 🞐 Set the Day button to set the day. ❑ Press Mode/Ret to exit. Daylight Savings Time The thermostat can automatically re-adjust its clock at Daylight Sav ings Time changeover. When this function is enabled (On), the ther mostat switches to Daylight Savings Time on the second Sunday of March and to normal time on the first Sunday of November. and GFCI reset 2 Appears when the setpoint is displayed Day and time Time and day display Temperature display Mode display NOTE: The function is disabled (default setting) when the clock loses its setting. ■ Press the Day button (3 seconds) until DLS appears settings Percentage of heating time 3 Program button Preset temperature indicator Ground fault indicator 4 Temperature control mode indicator on the screen. □ Press the to toggle between On (enabled) and Off (disabled). 🞐 Press the Day button briefly. The year setting is dis Program clear button Mode selection / program exit Backlight button Temperature preset buttons Period display Temperature adjustment buttons played. ❑ Press the to set the current year. ❒ Press the Day button briefly. The month setting is dis played. ⬧ Press the to set the current month. 1 Place the switch in Standby to cut power to the heater when not in use (e.g., in the sum mer). This will not affect the time and temperature settings. 2 If your thermostat is installed on a power base equipped with a ground fault protection, to reset the ground fault protection, switch the thermostat to Standby and back to On. 3 The thermostat displays the percentage of heating time required to maintain the desired temperature. For example, is displayed when heating is activated 40 percent of the ⧫ Press the Day button briefly. The date setting is dis played. ◆ Press the to set the current date. ❖ Press Mode/Ret to exit. time. Display % of heating time 1 to 24% 25 to 49% 50 to 74% 75 to 99% 100% 4 GFI appears when the ground fault protection has tripped. □ Configuration 2. Some thermostat configurations can be modified via switches on the back of the faceplate (control module). Default (factory) settings are inside the gray cells. # Configurations UP DN 1 Display format °F / 12 h °C / 24 h 2 Early Start a Enable Disable 3 Temperature control mode b F AF a. Early Start can be used in Automatic mode only. When this function is enabled, the thermostat calculates the optimal time to start heating in order to obtain the desired temperature by the set time. The thermostat re-assesses the start time daily based on the previous day's results. b. To select the F mode, place the switch in the F position. To select the AF mode, place the switch in the AF position and ensure that the remote temperature sensor is connected to the thermostat. To select the A mode, place the switch in the AF position and ensure that the remote temperature sensor is NOT connected to the thermostat. 🞐 Installation 3. ■ Refer to the installation ❒ Backlight 5. The display illuminates for 12 seconds when the backlight button is pressed. When either of the buttons is pressed, the display also illuminates for 12 seconds. The setpoint temperature appears for 5 seconds, then the actual (measured) temperature is displayed. ⬧ Temperature Adjustment 6. 6.1 Setpoint Temperature The thermostat normally displays the actual (measured) temperature. To view the setpoint, press one of the buttons once. The setpoint will appear for the next 5 seconds. To change the setpoint, press one of the buttons until the desired temperature is displayed. To scroll faster, press and hold the button. 6.2 Preset Temperatures The thermostat has 3 preset temperatures: Comfort temperature Economy temperature Vacation temperature To use a preset temperature, press the corresponding button. The corresponding icon , or will be displayed. instructions of the power base. □ Insert the tabs at the top of the control module in the slots at the top of the power base. 🞐 Secure the control module using the captive screw underneath the base. Control module Air vents Power base Air vents The following table shows the intended use and the default setting of each of the preset temperatures. Icon Intended use A/AF modes F mode Comfort (when at home) 21 °C (70 °F) 28 °C (82 °F) Economy (when asleep or away from home) 17 °C (63 °F) 20 °C (68 °F) Vacation (during prolonged absence) 10 °C (50 °F) 10 °C (50 °F) To store a preset temperature: NOTE: Keep the thermostat's air vents clean and unobstructed at all times. ■ Set the desired temperature using the buttons. □ Press and hold the corresponding button until the corresponding icon is displayed. TH115 A/F/AF 400-115-003-B 27/2/07 1/2 6.3 Floor Temperature Limits (AF mode only) NOTE: To avoid damaging your floor, follow your floor supplier's recom mendations regarding floor temperature limits. The minimum and maximum floor temperature limits are 5 °C (41 °F) and 28 °C (82 °F) by default. To modify these limits, proceed as follows: ■ Switch the thermostat to Standby. □ Press and hold the button. 🞐 Switch the thermostat back to On. ❑ Release the button when the minimum temperature limit (FL:LO) appears. ❒ Set the minimum temperature limit using the buttons. 7.3 Vacation Mode In this mode, the thermostat is set to Vacation temperature. There are two ways to place the thermostat in Vacation mode: By pressing the button on the thermostat. When the Vacation mode is activated using the button, the icon appears on the screen without flashing. From an Aube telephone controller (CT240/CT241) or any other remote control device equipped with a dry contact if your power base is equipped with the ECONO input. When the contact closes, the Vacation mode is activated and the icon flashes on the screen. All buttons on the thermostat are locked. When the ⬧ Press the button to display the maximum temperature limit (FL:HI). ⧫ Set the maximum temperature limit using the buttons. ◆ Press Mode/Ret to exit. contact opens, the thermostat returns to the preceding mode. NOTE: When the Vacation mode is activated using a remote control device, it can only be deactivated using the device. ⧫ Modes of Operation 7.◆ Error Messages 8. The measured temperature is below the thermostat's display The thermostat has 3 modes of operation. 7.1 Automatic Mode The thermostat follows the programmed schedule. To place the ther mostat in this mode, press Mode/Ret until is displayed. The data of the current schedule period are also displayed. range. Heating is activated. The measured temperature is above the thermostat's display range. Heating is deactivated. Verify the thermostat and sensor connections. : Temporary Bypass If you modify the setpoint temperature (by pressing the , or button) when the thermostat is in automatic mode, the new tempera ture will be used until the beginning of the next period. flashes dur ing the bypass. You can cancel the bypass by pressing Mode/Ret. Programmed Schedule The schedule consists of 4 periods per day which represents a typi cal week day. You can program the thermostat to skip the periods that do not apply to your situation. For example, you can skip periods 2 and 3 for the weekend. Period Description Associated temperature setting Wake-up Away from home Return home Sleep The Comfort ( ) temperature is used in periods 1 and 3 and the Economy ( ) temperature is used in periods 2 and 4. For example, when the period changes from 1 to 2, the setpoint automatically changes from Comfort ( ) temperature to Economy ( ) temperature. You can have a different program for each day of the week; i.e., each period can start at different time for each day of the week. The thermostat has been programmed with the following schedule. Period Setting MO TU WE TH FR SA SU 6:00 6:00 6:00 6:00 6:00 6:00 6:00 8:30 8:30 8:30 8:30 8:30 --:-- --:-- 17:00 17:00 17:00 17:00 17:00 --:-- --:-- 23:00 23:00 23:00 23:00 23:00 23:00 23:00 To modify the schedule: ■ Press Pgm to access the programming mode. Period 1 is selected. □ Press Day to select the day to program (hold for 3 seconds to select the entire week). 🞐 Press Hour and Min to set the start time of the selected period, or press Clear if you want to skip the period (--:-- is displayed). NOTE: If you intend to use only 2 periods, set periods "1 and 4" or periods "2 and 3". Early Start will not work if you set periods "1 and 2" or periods "3 and 4" . ❑ Press Pgm to select another period, or press Day to select another day. Then repeat step 3. ❒ Press Mode/Ret to exit the programming mode. NOTE: If no button is pressed for 60 seconds, the thermostat will automatically exit the programming mode. 7.2 Manual Mode The programmed schedule is not used. The temperature must be set manually. To place the thermostat in this mode: ■ Press Mode/Ret until is displayed. □ Set the temperature using the , or button. ❖ Technical Specifications 9. Power supply: Refer to the power base's installation guide. Display range: 0 °C to 70 °C (32 °F to 158 °F) Ambient setpoint range (A/AF modes): 5 °C to 30 °C (40 °F - 86 °F) Floor setpoint range (F mode): 5 °C to 40 °C (40 °F - 104 °F) Floor limit range (AF mode): 5 °C to 40 °C (40 °F - 104 °F) Display resolution: 0.5 °C (1 °F) Operating temperature: 0 °C to 50 °C (32 °F to 120 °F) Storage temperature: -20 °C to 50 °C (-4 °F to 120 °F) Heating cycle length: Refer to the power base's installation guide Data backup: In the event of a power failure, most settings are saved. Only the time must be re-adjusted if the power failure lasts more than 6 hours. The thermostat will return to the mode that was active prior to the power failure. 🖴 Warranty 10. Aube warrants this product, excluding battery, to be free from defects in the work manship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube's option). If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or (ii) contact Aube. Aube will make the determination whether the product should be returned, or whether a replacement product can be sent to you. This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or malfunction was caused by dam age which occurred while the product was in the possession of a consumer. Aube's sole responsibility shall be to repair or replace the product within the terms stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PROD UCT. Some provinces, states or regions do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some provinces, states or regions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from province, state or region to another. Customer Assistance 11.For any questions regarding product installation or operation, contact us at: 705 Montrichard Saint-Jean-sur-Richelieu, Quebec J2X 5K8 Canada Tel.: (450) 358-4600 Toll-free: 1-800-831-AUBE Fax: (450) 358-4650 E-mail: aube.service@honeywell.com For more information on our products, visit us at: www.aubetech.com TH115 A/F/AF 400-115-003-B 27/2/07 2/2
Đăng ký:
Đăng Nhận xét (Atom)
Black & Decker Black&Decker Vacuum NV4820CN, homeappliance
Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...
-
Download! BCM7255CN06EFM3.qxd 8/24/06 09:44 Page 1 Digital COOL MIST Humidifier MODEL BCM7255-CN HUMIDIFIER SAFETY PLEASE READ AN...
-
Download! BEFORE AFTER MODEL TH110A-DP-P B 240 VAC B B SUMMARY 60 HZ OPTIONS SELECTION B At the back of the thermostat...
-
Download! KV Push Owner's Manual BILLY GOAT KV VACUUM Owner's Manual KV600, KV650H, KV600FB, KV650HFB Accessories ON B...
Không có nhận xét nào:
Đăng nhận xét