Thứ Sáu, 27 tháng 8, 2021
Aube Technologies TH102D, homeappliance
Download!
RESET: To set the day To set the time To set the minutes To access programming mode and view programs To exit a function MODE: to select the desired operating mode Temperature adjustment buttons FAN: displayed when conventional temperature control is selected Heating indicators Room temperature Current program number when the Automatic mode is active Automatic Current time and day Econo SETPOINT: displayed when viewing or setting the temperature TIME: displayed when time needs to be adjusted LP: displayed during a power failure Current program number when Econo schedule is active To reset the thermostat mode Manual mode mode This thermostat has been designed to control a RESISTIVE load not exceeding 3500 W @ 240 VAC or 1750 W @ 120 VAC, such as electric baseboards, convectors, radiant ceilings, floor heating sys tems, etc. It is not compatible with a low voltage controller used by a cen tral heating system or systems using a contactor or a relay whose current is under 2 A. TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician. This thermostat is designed to be used with a self-pro tected heating system equipped with linear limit control and circuit breaker. For a new installation, choose a location about 5 ft. (1.5 m) above the floor, facing the heating system and on an inside wall. Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or con cealed chimneys or stove pipes. All cables and connections must conform to the local electrical code. Special CO/ALR solderless connectors must be used when connecting with aluminum conductors. The wires are not polarized, therefore the connections can be made on either terminal. PROVIDED PARTS 🖉 One (1) TH104 thermostat ✂ Two (2) 6-32 mounting screws ✁ Two (2) solderless connectors Connect the rear wires to the power and load using solderless con nectors for copper wires. 2 WIRES 4 WIRES 1/4 400-104-000-A Push the excess wire into the electrical box to prevent interference with the thermostat. Secure the base to the electrical box using the provided screws. The base can be secured on the left or right hand side of the electri cal box. ! To change the time display format from 12 to 24 hours and vice-versa: Press and hold ; do not release. Reset the thermostat using a pointed object (e.g. paperclip). Release the button. ! TO RESET THE THERMOSTAT Once the thermostat is configured and installed, return power to heating system. Keep the thermostat's air vents clean and free from obstructions. $ % & '(% To view the ambient temperature, peel the lower-right section of the The TH104 is factory-set to use the proportional temperature con trol type (15-second cycles). Since this temperature control type uses a fast commutation rate, it is not compatible with fan-equipped systems. Also, it can also cause light flickering, especially in rural regions. If you have a fan-equipped system, use the conventional tempera ture control type (15-minute cycles). To change the type: Press and maintain , do not release. Reset the thermostat using a pointed object (e.g. paperclip). sticker and remove it from the display. When you first power on the thermostat, the display indicates: 0:00, MO (Monday), the ambient temperature and the MANual mode is selected (framed). The default setpoint is preset to 20°C. Protected memory Release the button. Following the change, the FAN indicator is displayed on the screen. To revert to proportional control, repeat above steps. )*" ( #( ) ) + NOTE: You should select the options before you adjust the clock During a power failure, all programs are protected. The thermostat display remains on for approximately 15 minutes after which the LP indicator is displayed (low power). Only the time must be reset if the power failure exceeds 6 hours. The thermostat will automatically return to the previous mode when power returns. & ( ( The TH104 offers the following options: Temperature display °C °F Time display 24 h 12 h Temperature control Proportional Conventional Highlighted options are factory pre-set. If these options fit your requirements, go to the next menu. ! To change the temperature display from °C to °F and vice-versa: Press and hold , do not release. Reset the thermostat using a pointed object (e.g. paperclip). Release the button. and day settings because using the reset button when selecting options will reset the clock. The TIME icon flashes to indicate that the clock needs to be adjusted. 🖉 Press to set the day. ✂ Use the and buttons to set the clock. ✁ Press to exit. &(% # )( The TH104 has three operating modes: " This mode automatically runs your programs. Press MODE until AUTO is outlined. The current program number is displayed above the AUTO icon. To temporarily bypass the current program, simply select the desired temperature using the tempera ture adjustment buttons. The new setpoint will be maintained until the beginning of the next program. # Maintains a constant temperature setpoint. Press MODE until MAN is outlined and select the desired temperature using the temperature adjust ment buttons. 2/4 400-104-000-A ( This mode automatically runs the programs of the Econo schedule. Press MODE until ECONO is outlined. The current program number is displayed above the ECONO icon. " # ()" ( The TH104 schedule offers 4 programs per day for the weekdays and 4 programs per day for the weekend. There are no preset pro grams. The schedule maintains the setpoint associated to a pro gram until the beginning of the next one. For maximum energy savings, the following schedule is recom mended: Programs Time Setpoint Monday to Friday (same programs for all days of the week) 1 Morning 6:00 21°C 2 Day 8:00 17°C 3 Evening 17:00 21°C 4 Night 23:00 17°C Saturday and Sunday (same programs for the weekend) 1 Morning 6:00 21°C 2 Day 8:00 17°C 3 Evening 17:00 21°C 4 Night 23:00 17°C ( ()" ( Ideal for cottages, chalets or weekend residences, this schedule enables the user to enter 2 settings. The first setting lets the user enter a time (i.e. shortly before expected arrival) at which the thermostat commands the heating system to warm to comfort setpoint. The second setting commands a temperature decrease. Programs Day Time Setpoint 1 Arrival (start heating) Friday 3:00 p.m. 21°C 2 End of heating period Friday 8:00 p.m. 15°C " , ( # At your arrival, switch to Automatic mode. The thermostat will run your programs of the automatic schedule, keeping a comfortable temperature during the day and decrease the temperature during the night. When you leave, switch to Econo mode. The thermostat will auto matically maintain the setpoint of the last program (e.g. 2) until the beginning of the next program. & , , ( # Before you start programming your thermostat, press MODE until ECONO is selected (outlined). 🖉 Press . The program number is displayed (1). , Before you start programming your thermostat, press MODE until AUTO is selected (outlined). 🖉 Press . The program number is displayed. ✂ Press to select the expected arrival day. ✁ Use and to set the time. Weekdays are displayed (MOTUWETHFR). 👓 Use the temperature adjustment buttons to define the setpoint. 🕭 Press to select the next program (2). ✂ Use HOUR and MINUTE to set the time. To skip a program (inactive --:--), do not set the time. ✁ Use the temperature adjustment buttons to define the setpoint. 👓 Repeat steps 1 to 3 for remaining programs. For the weekend programs: 🕭 Press . The program number is displayed (1). Weekend days are also displayed (SU and SA). 🕮 Repeat steps 2 to 4. 🕯 Press to exit programming mode. 🕮 Repeat steps 2 to 4 to select the day, time and setpoint. 🕯 Press to exit programming mode. 3/4 400-104-000-A ( &( $ Model: TH104 Supply: 120/240 VAC, 50/60 Hz Power consumption (off): 860 mW Load: 14.6 A maximum (resistive only), 2 A minimum Power: 1750 W @ 120 VCA / 3500 W @ 240 VCA Temperature display range: 0°C to 99°C (0°F to 99°F) Temperature setting range: 5°C to 27 °C (40°F to 80°F) Display resolution: 1° Storage temperature: -20°C to 50°C (-4°F to 120°F) Accuracy: proportional: ± 0.15°C (0.27°F) from the setpoint conventional: ± 0.5°C (0.9°F) from the setpoint Approval: CSA / UL Dimensions: 120 x 115 x 26 mm (4.8 x 4.5 x 1 inch) - " (#&(% "%( % The TH104 works differently than conventional electromechanical thermostats which can have a temperature differential up to 4°C and 5°C. The TH104 has a temperature differential of ± 0.15°C from the setpoint. This slight oscillation eliminates the discomfort often found with conventional electromechanic thermostats. For each cycle, the proportional controller determines the "On" operating time required by the heating system to maintain the set point temperature. The following table displays the percentage of the "On" operating time for the heating cycle: 1 to 25% 26 to 50% 51 to 75% 76 to 100% If you are using the conventional control (fan-forced heater), the screen will show the FAN indicator as well as all flame icons ( ) when the system is activated. In this case, the thermostat differen tial is ± 0.5°C from the setpoint. NOTE: The temperature display resolution is 1°C, but the tempera ture is internally controlled at 0.01°C. ( "&& % If you have any questions concerning the installation of the TH104 thermostat, contact our technical support team at: Tel.: (450) 358-4600 1-800-831-AUBE (2823) Fax: (450) 358-4650 Email: service@aubetech.com Monday to Friday from 8:30 AM to 5:00 PM EST For more information on our products, visit us at www.aubetech.com ' %% + AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. cannot be held lia ble for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address: Aube Technologies Inc. 705 Montrichard Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8 PROBLEM POSSIBLE CAUSE SOLUTION No display Circuit breaker is open Power failure Verify voltage presence at the thermostat Thermostat is hot In normal use, at full capacity (3000 W), the thermostat housing may reach a temperature of 35°C to 40°C This state is normal and does not affect temperature control Displayed temperature is wrong • A draft is near the thermostat • The sticker is still on the thermostat display • Eliminate the draft • Remove the sticker The lights are flickering Fast current switching in the baseboards, mainly in rural regions • Use conventional control mode See Options selection section System is always on Bad installation • Verify installation • Reset the thermostat: press PROGRAM while resetting the unit, release PROGRAM (see Options selection section) Screen shows the heating icon, but the system is not heating • Bad installation • Power failure (LP indicator is displayed) • Verify installation 03/06/2004 4/4 400-104-000-A TH104-SW PROCEDURE LOCKED KEYBOARD MAINTAINING THE TEMPERATURE AROUND THE CLOCK 1- Press the MODE button to place the thermostat in ECONOMY mode. 2- Press the PGM button to select ECONO 1 or ECONO 2. 3- Choose the desired temperature. It is not necessary to specify a time or day. 4- Press on the RET button to end the programming. Wait a minimum of 30 seconds for the program to be saved. 5- To prevent access to the thermostat keyboard, start by turning off the heating system to avoid electrical shocks. LOCKED IN AUTO MODE 1- Press the MODE button to place the thermostat in AUTO mode. 2- Press on the PGM button and enter the desired programming (see the Suggested Typical Programming section in the instruction sheets). 3- Press on the RET button to end the programming. Wait a minimum of 30 seconds for the program to be saved. To prevent access to the thermostat keyboard: 1- Start by turning off the heating system to avoid electrical shocks. 2- Remove the thermostat from the electrical box and set the appropriate switches as follows: 6- Remove the thermostat from the electrical box and set the appropriate switches as follows: AUTO MODE: Switches #1 ON and #2 OFF 3- Put the thermostat back on the electrical box and turn the heating system back on. ECONO 1: Switches #1 and #2 ON ECONO 2: Switches #1 OFF and #2 ON The word REMOTE as well as the program number will show on the screen. The buttons are now disabled. 4- If you wish to modify your programming, turn the heating system off again to avoid electrical shocks. 5- Next, set all switches to OFF and repeat the above steps. 7- Put the thermostat back on the electrical box and turn the heating system back on. The word REMOTE as well as the program number will show on the screen. The buttons are now disabled. 8- If you wish to change the programmed temperature, turn the heating system off again to avoid electrical shocks. 9- Next, set all switches to OFF and repeat the above steps. 04/12/00 720-104001
Đăng ký:
Đăng Nhận xét (Atom)
Black & Decker Black&Decker Vacuum NV4820CN, homeappliance
Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...
-
Download! BCM7255CN06EFM3.qxd 8/24/06 09:44 Page 1 Digital COOL MIST Humidifier MODEL BCM7255-CN HUMIDIFIER SAFETY PLEASE READ AN...
-
Download! BEFORE AFTER MODEL TH110A-DP-P B 240 VAC B B SUMMARY 60 HZ OPTIONS SELECTION B At the back of the thermostat...
-
Download! KV Push Owner's Manual BILLY GOAT KV VACUUM Owner's Manual KV600, KV650H, KV600FB, KV650HFB Accessories ON B...
Không có nhận xét nào:
Đăng nhận xét