Chủ Nhật, 15 tháng 8, 2021
Aprilaire Air Cleaner 16, homeappliance
Download!
WARNING 1. High voltage may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation. 2. Sharp edges may cause injury from cuts. Use care when cutting and handling sheet metal. SPECIFICATIONS Airflow Capacity: up to 2000 CFM maximum Model 1610 Easy Install™ Media Air Cleaner Installation Instructions CAUTION 1. To prevent component failure, do not install the air cleaner on the warm air supply or in an area where the temperature may exceed 140°F. This may include areas above heat exchangers in downflow furnaces or above exhaust flues in lowboy furnace cold air returns. 2. Installation must be done by a qualified heating and air conditioning professional. Read instructions thoroughly before beginning installation. 3. Do not install air cleaner downstream of a UV light. UV lamps will cause degradation of the filtering media. Replacement Media: Model 410 or 413 with SelfSeal™ Air Cleaner Operating Environment: Temperature: 0°F – 140°F DIMENSIONS Figure 1 – Air Cleaner Dimensions 15.7" 17.8" 28.2" 30.1" 22.0" 15.5" 10-11479 LOCATING THE AIR CLEANER 1. The air cleaner can be mounted on the right or left side of the HVAC equipment (see Figure 2). 2. The door can be facing the front or rear of the HVAC equipment cabinet (see Figure 2). 3. The door and blanking plate are reversible to allow filter access from the front or rear of the HVAC equipment cabinet (see Figure 2). 4. Leave sufficient space (29") for the removal of the filtering media (see Figure 3). Figure 2 The door and blanking panel are reversible to allow filter access from the front or back. BLANKING PLATE 10-11481 Figure 3 10-11483 29" FOR FILTER REPLACEMENT DOOR Easy to Install Air Cleaner Features The air cleaner has many features to make retrofit easier: 1. The cold air return opening is adjustable between 8" and 10". This is done by bending up the appropriate tabs. The 8" dimension can be offset to the right or left by moving the "L" bracket to either side to match up with the location of the return drop. Figure 4 – 8" x 24" Offset Right Figure 5 – 8" x 24" Offset left L BRACKET 2 L BRACKET BEND UP TABS BEND UP TABS 10-11490 10-11490 2. The "L" bracket can removed to form a 10"x 24" drop opening. See Figure 6. 3. If the cold air drop is less than 24 inches deep an angle bracket can be field fabricated and installed to reduce the drop width. See Figure 7. 4. The cold air return can be moved into position over the top of the air cleaner (Figure 8) or transition pieces field fabricated (Figure 9). 5. Four tabs are located on the outlet side of the air cleaner. These tabs can be bent into the cold air return opening on the HVAC equipment to hold the air cleaner in position during installation. See Figure 10. Figure 6 BEND ALL Figure 7 TABS UP FIELD FABRICATED ANGLE BRACKET Figure 8 Figure 10 COLD AIR RETURN DROP MOVED 10-11490 10-11491 10-11498 Figure 9 FIELD FABRICATED TRANSITION 30° MAX ANGLE 10-11490 10-11491 3 INSTALL THE AIR CLEANER CABINET WARNING 120 Volts may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation. Leave power disconnected until installation is completed. 1. Disconnect power to the furnace or air handler at the electrical service panel. 2. Remove filtering media from the air cleaner cabinet. 3. If replacing an existing filter, remove the filter and thoroughly clean the blower compartment. 4. Determine which side of the furnace the air cleaner cabinet will be mounted to and set up the blanking plate accordingly. 5. Determine the cold air return drop sizing and location and bend up tabs on the top of the air cleaner cabinet accordingly. 6. Use the tabs to fix the air cleaner cabinet to the opening in the furnace. Use screws (field supplied) to mount the unit to the furnace/air handler. 7. Mount the return ductwork over the bent-up flanges on the top of the air cleaner cabinet with sheet metal screws (field supplied). 8. Seal all connections using mastic, foil tape or silicone based caulk. 9. Install the filtering media (see Figure 11). 10. Install the door. 11. Reconnect power to the furnace or air handler at the electrical service panel. Figure 11 Expand clean filter. Install filter with Air Flow pointing toward Furnace or Air Handler. 10-11500 Align filter in top and bottom rails and slide into place. Reinstall door. P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 • www.aprilairepartners.com 10010740 3.14 Printed in U.S.A. B2701329A 4 © 2014 Aprilaire – A division of Research Products Corporation
Đăng ký:
Đăng Nhận xét (Atom)
Black & Decker Black&Decker Vacuum NV4820CN, homeappliance
Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...
-
Download! BERNINA® www.berninausa.com What is BSR? The BERNINA® Stitch Regulator The revolutionary Bernina Stitch Regulator (BSR) all...
-
Download! Power Vent & Power Direct Vent Replacement Parts No. Part Name and Description Repair Parts Illustration Repair Part...
-
Download! Service Handbook RESIDENTIAL HYBRID ELECTRIC HEAT PUMP WATER HEATER FOR MODELS: HPE10260H045DV (60 GAL.) HPE10280H045DV (...
Không có nhận xét nào:
Đăng nhận xét