Chủ Nhật, 15 tháng 8, 2021
Aprilaire 2210, homeappliance
Download!
WARNING 1. High voltage may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation. 2. Sharp edges may cause injury from cuts. Use care when cutting and handling sheet metal. SPECIFICATIONS Airflow Capacity: up to 2000 CFM maximum Replacement Media: Media Air Cleaners Installation Instructions CAUTION 1. To prevent component failure, do not install the air cleaner on the warm air supply or in an area where the temperature may exceed 140°F. This may include areas above heat exchangers in downflow furnaces or above exhaust flues in lowboy furnace cold air returns. 2. Installation must be done by a qualified heating and air conditioning professional. Read instructions thoroughly before beginning installation. 3. Do not install air cleaner downstream of a UV light. UV lamps will cause degradation of the filtering media. Max. Equipment Weight: Cabinet will support 400 lb. static load 1210, 2210, 3210: Model 210 or 213 with SelfSeal™ 1310, 2310, 3210: Model 310 or 313 with SelfSeal™ 1410, 2410, 3410: Model 410 or 413 with SelfSeal™ DIMENSIONS B without door C A Air Cleaner Operating Environment: Temperature: 0°F – 140°F Humidity: 0-90% non-condensing D E with door F G H 90-1333 TABLE 1 – Dimensions (inches) Model A B C D E F G H 1210, 2210, 3210 19-3/4 25-3/8 21-3/16 6-3/4 27-3/8 21-3/16 19-3/4 22-1/16 1310, 2310, 3310 18-1/16 20-1/16 15-7/8 6-3/4 22-1/16 15-7/8 18-1/16 20-3/8 1410, 2410, 3410 15-7/16 28-1/16 23-7/8 6-3/4 30-1/16 23-7/8 15-7/16 17-3/4 INSTALL THE AIR CLEANER CABINET LOCATING THE AIR CLEANER 1. Leave sufficient space in front of the air cleaner for the removal of the filtering media (see Figure 1). 2. DO NOT INSTALL DOWNSTREAM OF A UV LIGHT. UV lamps will cause degradation of the filtering media. 3. Figures 2-4 show typical applications. Figure 2 – Horizontal Installation Airflow 90-1319 Figure 3 – Highboy Installation Airflow Airflow 90-1318 Figure 4 – Highboy Upflow Installation Figure 1 – Filtering Media Clearance 90-1374 29" Airflow Airflow Airflow 30° max 45° max 90-1320 2 INSTALLATION 1. Disconnect power to the furnace or air handler at the electrical service panel. WARNING 120 Volts may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation. Leave power disconnected until installation is completed. 2. Remove the air cleaner door from the outer housing and pull out the filtering media. 3. If replacing an existing filter, remove the filter and thoroughly clean the blower compartment. 4. Use screws (field supplied) to mount the outer housing to the furnace/air handler. There is no inlet or outlet side on the outer housing (the outer housing can be mounted on the left or right side of the furnace/air handler). Figure 5 90-1374 NOTE FOR UPFLOW INSTALLATIONS: Provide support under the outer housing to ensure the quality of the seals (see Figure 5). 5. Mount the return ductwork to the outer housing. 6. Seal all connections using mastic, foil tape or silicone based caulk. 7. Install the filtering media (see Figure 6). 8. Install the door. 9. Reconnect power to the furnace or air handler at the electrical service panel. Figure 6 Expand clean filter. Install filter with Air Flow pointing toward Furnace or Air Handler. Align filter in top and bottom rails and slide into place. Reinstall door. 3 P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 • www.aprilairepartners.com 10009757 1.12 Printed in U.S.A. B2701229A © 2012 Aprilaire – A division of Research Products Corporation
Đăng ký:
Đăng Nhận xét (Atom)
Black & Decker Black&Decker Vacuum NV4820CN, homeappliance
Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...
-
Download! BCM7255CN06EFM3.qxd 8/24/06 09:44 Page 1 Digital COOL MIST Humidifier MODEL BCM7255-CN HUMIDIFIER SAFETY PLEASE READ AN...
-
Download! BEFORE AFTER MODEL TH110A-DP-P B 240 VAC B B SUMMARY 60 HZ OPTIONS SELECTION B At the back of the thermostat...
-
Download! KV Push Owner's Manual BILLY GOAT KV VACUUM Owner's Manual KV600, KV650H, KV600FB, KV650HFB Accessories ON B...
Không có nhận xét nào:
Đăng nhận xét