Thứ Sáu, 13 tháng 8, 2021
APC NETWORKAIR ACPA4000, homeappliance
Download!
InRoom™ Precision Air Conditioner Technical Data ACPDX21-86, ACPCW40-150 American Power Conversion Legal Disclaimer The information presented in this manual is not warranted by the American Power Conversion Corporation to be authoritative, error free, or complete. This publication is not meant to be a substitute for a detailed operational and site specific development plan. Therefore, American Power Conversion Corporation assumes no liability for damages, violations of codes, improper installation, system failures, or any other problems that could arise based on the use of this Publication. The information contained in this Publication is provided as is and has been prepared solely for the purpose of evaluating data center design and construction. This Publication has been compiled in good faith by American Power Conversion Corporation. However, no representation is made or warranty given, either express or implied, as to the completeness or accuracy of the information this Publication contains. IN NO EVENT SHALL AMERICAN POWER CONVERSION CORPORATION BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL, OR INCIDENTAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, CONTRACT, REVENUE, DATA, INFORMATION, OR BUSINESS INTERRUPTION) RESULTING FROM, ARISING OUT, OR IN CONNECTION WITH THE USE OF, OR INABILITY TO USE THIS PUBLICATION OR THE CONTENT, EVEN IF AMERICAN POWER CONVERSION CORPORATION HAS BEEN EXPRESSLY ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AMERICAN POWER CONVERSION CORPORATION RESERVES THE RIGHT TO MAKE CHANGES OR UPDATES WITH RESPECT TO OR IN THE CONTENT OF THE PUBLICATION OR THE FORMAT THEREOF AT ANY TIME WITHOUT NOTICE. Copyright, intellectual, and all other proprietary rights in the content (including but not limited to software, audio, video, text, and photographs) rests with American Power Conversion Corporation or its licensors. All rights in the content not expressly granted herein are reserved. No rights of any kind are licensed or assigned or shall otherwise pass to persons accessing this information. This Publication shall not be for resale in whole or in part. Contents Overview ..................................................................................................... 1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Scalable Solution for Critical Environments . . . . . . . . . . . . . . . . . . . . . . . . .2 Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Optional Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Condensers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Display Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 InRoom Model Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 InRoom Cooling Unit Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 60Hz Performance Specifications .......................................................... 23 Chilled Water (CW) – 60Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Air Cooled (DX) System – 60Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 MultiCool – Air Cooled (DX) with CW – 60Hz. . . . . . . . . . . . . . . . . . . . . . . .27 Fluid Cooled (Glycol 40%) – 60Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Fluid Cooled (Glycol 0%) – 60Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 Fluid Cooled (Glycol 0%) with CW – 60Hz . . . . . . . . . . . . . . . . . . . . . . . . . .34 Fluid Cooled (Glycol 40%) with CW – 60Hz . . . . . . . . . . . . . . . . . . . . . . . . .37 Fluid Cooled (Glycol 40%) with Economizer - 60Hz . . . . . . . . . . . . . . . . . .40 60Hz InRoom Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 50Hz Performance Specifications .......................................................... 45 Chilled Water (CW) - 50Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 Air Cooled (DX) System - 50Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 MultiCool - Air Cooled (DX) with CW - 50Hz . . . . . . . . . . . . . . . . . . . . . . . .49 Fluid Cooling (Glycol 40%) – 50Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 Fluid Cooled (Glycol 0%) – 50Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 Fluid Cooled (Glycol 40%) with CW - 50Hz . . . . . . . . . . . . . . . . . . . . . . . . .56 Fluid Cooled (Glycol 40%) with Economizer - 50Hz . . . . . . . . . . . . . . . . . .59 50Hz InRoom Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 General Specifications ............................................................................ 63 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 Transporting and Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 Guidelines for Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 Piping Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 InRoom Guide Specifications ................................................................. 74 Warranty ................................................................................................... 84 InRoom Precision AC Tech Data Manual i InRoom Nomenclature Product Range Cooling System Model Size Number of Refrigeration Circuits Airflow Pattern D - Downflow, U - Upflow 0, 1, 2 DX: 21, 31, 45, 61, 86 CW: 40, 66, 90, 110, 150 P = Perimeter unit Voltage Phase/Hertz Reheat Humidification Mains Input Selection 0 - Standard Disconnect, 1 - Dual Power with ATS *, 2 - Dual Power without ATS **, X - None, E - Immersed Electrode X - None, E - Electric A: 3/60 A: Air-cooled G: Glycol-cooled ACW: Air-cooled with MultiCool GCW: Glycol-cooled with MultiCool GE: Glycol-cooled with Economizer CW: Chilled Water a 8 6 8 2 a n B: 208-230V G: 380-415V K: 460-480V M: 575-600V Z: 400V B: 3/50 Refrigerant Head Pressure Control Valve Chilled Water Valve Hot Gas By-pass Valve Placeholder X - Reserved for Future Use X - None H - HGPV X - None, 2 - 2-way, 3 - 3-way X - None, 2 - 2-way, 3 - 3-way X: None H: R407C * Dual Power with ATS - Base Cooling Units without Heat and Humidifier with two Disconnects. ** Dual Power without ATS - Units with Heat and Humidifier with one Disconnect. ii InRoom Precision AC Tech Data Manual Overview General The InRoom product family is an assemble to order (ATO) line of perimeter air conditioning systems that provide precision cooling for data centers and server rooms. Precision environmental close control requirements now reach far beyond the confines of the traditional data center or computer room to encompass a larger suite of applications, referred to as technology rooms. Critical environment applications include: • Computer rooms • Telecommunication facilities • Clean rooms • Power equipment • Medical equipment rooms • Archives • LAN/WAN environments A worldwide network of APC representatives is fully qualified to provide engineering, sales, installation and service for our products. APC warrants all parts for 1 year. Models The InRoom precision air conditioning unit is available in five sizes. The system is available in both chilled water and direct expansion for a combination of six heat rejection methods. Select from ACPDX21-86 and ACPCW40-150. Room Air Distribution The InRoom downflow system draws warm exhaust air in through the top of the unit and cools it. The cool air is distributed back into the room through a raised floor plenum. These systems are ideal for areas with raised floors greater than 305 mm (10 in) high. Upflow systems draw warm exhaust air in through the front of the unit. The warm exhaust air is then cooled and discharged back into the room through a plenum or ductwork. Upflow systems are ideal for areas without a raised floor, but can also be used in a raised floor environment. The InRoom precision air conditioner delivers high volume airflow to help eliminate hot spots in densely populated environments. Configurations • Air Cooled • Air Cooled with Chilled Water Coil (MultiCool) • Chilled Water Coil • Fluid Cooled (Glycol) • Fluid Cooled (Glycol) with Economizer Cooling Coil • Fluid Cooled (Glycol) with Chilled Water Coil Compliance Approval 1. ETL/CETL 2. NTRL Listed 3. Electrical Systems comply with NEC and UL 1995/ CSA22.2 No.236 C US Standard Features 1. Insulated Cabinet 2. Direct Drive Fans 3. Electrical Panel 4. Main Power Disconnect Switch 5. Refrigeration System with Scroll Compressor and Crankcase Heater (DX only) 6. Redundant Group Control 7. Network Management Card 8. Electronic Expansion Valve (DX only) 9. Duct Flange (Upflow only) 10. 30% ASHRAE Air Filters 11. Brazed plate condenser 12. 2 or 3 Way Fluid Regulating Valves (Glycol models) 13. 2 or 3 Way Fluid Regulating Valves (CW only) 14. Discrete Input/Output Interface 15. Resettable Circuit Breakers 16. Microprocessor Controller 17. Graphical User Interface 18. Electrically Commutated (EC) Fans 19. Stainless Steel Condensate Pan 20. Automatic Transfer Switches Optional Features 1. Plenum 2. Sub-base Plenum 3. Floorstand 4. Seismic Floorstand 5. Immersed Electrode Humidifier 6. Condensate Pump 7. Electric Heat 8. Spot Water Detector(s) 9. Cable Water Detector(s) (60 Hz only) 10. Smoke Detector 11. Hot Gas Bypass Valve InRoom Precision AC Tech Data Manual 1 Scalable Solution for Critical Environments Temperature and Humidity Design Conditions Maintenance of temperature and humidity design conditions is critical to the smooth operation of a technology room. Based on ASHRAE TC9.9, the recommended design conditions for class one and class two environments should be 20–25°C (68–77°F) and 40–55% relative humidity (R.H.). Precision air conditioning is designed to maintain temperature at ±2°F and humidity at ±3–5% R.H. 24 hours a day, 365 days a year. Vapor barriers and sealed rooms are required to maintain these tolerances. In contrast, comfort systems are designed to maintain ±5°F from the temperature setpoint. There is usually no dedicated humidity control and the simple controllers cannot maintain the setpoint tolerance required for temperature, allowing potentially harmful temperature and humidity swings to occur. This is not acceptable for sensitive electronic equipment. Air Quality Precision air conditioners provide a high volume of air flow, around 600 CFM/ton (286 L/m, 150 CFM/kW). This high CFM moves more air through the space improving air distribution and reducing the chance of localized hot spots. It also allows more air to move through filters, ensuring a cleaner environment. This requires a moderate-to high efficiency filter bank to minimize airborne particles. Low Humidity Low humidity greatly increases the possibility of static electric discharges. Static discharges can corrupt data and damage hardware. High Humidity High humidity can result in tape surface deterioration, head crashes, condensation, corrosion, paper handling problems and gold and silver migration leading to component and board failure. High & Low Temperature A high or low temperature or rapid temperature swings can corrupt data processing and shut down an entire system. Temperature variations can alter the electrical and physical characteristics of electronic chips and other board components causing faulty operation or failure. These problems may be transient or may last for days. Transient problems can be very difficult to diagnose and repair. Efficiency and Reliability The use of energy efficient, direct drive fans along with fewer moving internal parts eliminate most potentials for failure. Scroll compressor technology provides unparalleled efficiency and con stant, reliable operation with an ability to withstand liquid refrigerant 'slugging' which is a major cause of compressor fail ure. The compressor is also equipped with an internal high pressure sensor which opens a bypass valve in case of high pressure. This ensures internal pressure compensation takes place and damage to the compressor is avoided. APC InRoom - The Right Solution The APC InRoom cooling unit provides the maximum amount of precision cooling in a compact footprint with the lowest operating cost and noise level. Dedicated Dehumidification Cycle A dedicated dehumidification cycle allows the system to increase latent capacity without boosting compressor capacity, and also lowers the requirement for reheat. To achieve dehumidification, the electronic expansion valve is first partially closed. The reduction of the refrigerant mass flow makes the evaporation temperature drop, which lets the surface temperature in a part of the evaporator fall below the dew point of the air, causing dehumidification. For increased dehumidification, the fan speed is reduced. With a constant cooling capacity, the temperature of the air which flows through the heat exchanger coil passes below the dew point. The moisture contained in the air condenses on the heat exchanger, gathers in the condensate pan, and is carried away by the drain. To achieve humidification for the DX units with cabinet size 1 and all CW units, the fan speed is reduced. For the DX units with cabinet size 2–5, approximately one third of the evaporator is isolated from the refrigerant flow by a solenoid valve to achieve dehumidification by lowering the evaporator temperature below the dew point. 2 InRoom Precision AC Tech Data Manual Standard Features Insulated Panels The frame is constructed of 16 gauge steel sheet metal for maximum strength. All exterior panels and corner posts on the frame are powder coated for durability and an attractive finish. The side panels are double wall construction (inner and outer panels) with insulation between. The insulation is 12 mm (1/2 in) thick fiberglass. The walls isolate the insulation from the air stream and further reduce sound levels. Panels are hinged and removable for easy access. The cabinet is serviceable from the front of the unit. Electronically Commutated (EC) Fans Each unit is equipped with electronically commutated (EC) fan modules. This technology increases fan efficiency by up to 30% while reducing operating costs. Each fan module has an anti-vibration mounting to isolate it from the unit structure. Electrical Panel The electrical panel contains the contactors, starters, overload protection devices, and input power disconnects. Main Power Disconnect Switch A main power disconnect switch disconnects all high voltage power to the unit if necessary. The disconnect switch is accessible without removing the electric box cover. Network Management Card Permits multi-level access to monitoring, control, and event notification features over the building management network. Refrigeration System and Compressor The refrigeration system operates under a master controller for greater efficiency and accuracy. Suction and discharge pressures (DX models) are monitored and electronically controlled. The scroll compressors are designed for year-round operation with a 15-year life expectancy. The controller microprocessor provides real-time suction and discharge pressure readings reported by transducers installed on the refrigeration system. For compressor protection, the InRoom precision air conditioner utilizes charge isolation and crank case heaters during off cycles (DX only). This eliminates the threat of liquid refrigerant migration that could lead to compressor slugging and lubrication issues. Mains Automatic Transfer Switches Mains automatic transfer switches allow two power sources to be connected to the cooling unit. A secondary power source (generator or UPS) can be automatically transferred in the event of a failure of the main power source to maintain cooling. Programmable switches are voltage adjustable with On and Off delay which can be adjusted from 0 to 20 seconds. The Off delay should be set to 3 seconds. Contact customer support for assistance to determine your requirements. Duct Flange A 25 mm (1 in) duct flange is included for the upflow units to provide convenient connection to external ductwork for either supply or return air as needed. Evaporative Freeze Protection Suction pressure is actively monitored by two individual sensors and controlled by the microprocessor controller to calculate the opening of the electronic expansion valve, eliminating the risk of condensate freeze-up on the evaporator coil. Redundant Group Control Allows up to 16 units to communicate with each other for redundancy, demand fighting prevention, and mode assist. Global sharing of certain settings requires a twisted pair shielded wiring interconnection. 30% ASHRAE 52.1 Filters The filtration of conditioned air is extremely vital to maintaining the clean, particle-free environment required by electrical equipment. The system uses 30% (100 micron) filters, with full depth filter pleats. Deeper filters produce a lower pressure drop, requiring less energy during normal operation. Filters are replaceable through the front of the upflow unit and through the top of the downflow unit. Condenser (Direct Expansion units only) Standard air cooled condensers are suitable for cooling up to the maximum ambient temperature of either 35°C (95°F) or 46.1°C (115°F) depending on the requirement. These condensers have variable fan speed controls to allow operation down to -28.9°C (-20°F). InRoom Precision AC Tech Data Manual 3 Optional Features Humidifier The humidifier utilizes a pure steam generator specifically designed for precision environmental close control. The pure steam eliminates contaminating mineral deposits, potentially harmful bacteria, white dust, and excessive humidity. The humidifier requires little scheduled maintenance. The humidifier is proportionally controlled to meet the humidification demands of the conditioned space. Humidifier canisters are replaceable. Electric Reheat Electric reheat elements are low watt density, wired for 3-phase and loaded equally on all three phases, SCR controlled, and electrically and thermally protected by both automatic and manual reset thermal cut outs. Reheat coils are stainless steel, tubular fin construction. Spot Water Detector The solid-state spot water detector is available for both 50 and 60 Hz cooling units. The spot water detector activates an audible alarm on the controller when moisture is detected. Smoke Detector The factory-installed smoke detector is designed to sense smoke in the return air stream. Upon detection of smoke, an audible and visual alarm on the microprocessor controller will be activated and the unit will be shut down immediately. Hot Gas Bypass Valve The hot gas bypass valve (HGBV) adjusts the flow of compressor discharge gas to the evaporator coil at low load conditions to protect the coil from freezing and the compressor from excessive cycling. 60 Hz cooling units use a mechanical HGBV. 50 Hz cooling units use an electronically controlled HGBV. On 50 Hz cooling units, the HGBV option requires the analog extension board EAIO. Cable Leak Detector (60 Hz only) The optional 6 m (20 ft) leak detection sensing cable (APC part number ACAC75105) is available for 60 Hz cooling units only. The cable leak detector is placed on the floor or subfloor around all possible leak sources. If water or other conductive liquids contact the cable anywhere along its length, the master controller visually and audibly announces the leak. Floorstand The floorstand raises the unit above the subfloor to match the height of the raised floor. Heights are available from 254 mm (10 in) to 610 mm (24 in) in 76.2 mm (3 in) increments and are adjustable +/– 38.1 mm (1.5 in). Adjustment is provided by threaded pedestals. Vibration absorbing pads are included. The floorstand, pedestal, and pads ship loose. In areas where earthquakes are a concern, seismic floorstands are available in 305 mm (12 in), 457 mm (18 in), and 610 mm (24 in) heights. Plenums Discharge plenums are available on upflow configurations. This application is recommended in rooms where raised floors are not available for air distribution. Discharge air should be ducted down cold aisles. Base Plenum Insulated base plenums are available for downflow cooling units where raised floors are not available for air distribution. Four front-discharge configurations are available equipped with dampers, grilles, flexible ductwork or open. All configurations are 450 mm (17.7 in) high and sit beneath the InRoom cooling unit. Water Regulating Valves Water and fluid cooled systems utilize two- or three-way valves to regulate the amount of water or glycol supplied to the condenser in response to refrigerant discharge pressure. The standard valve pressure rating is 28 kPa (400 psi). Extreme Low Temperature Kit (Direct Expansion units only) Extreme Low Temperature Kits for air cooled condensers are available for operation below –34.4°C (–30°F). The optional kit consists of pressure control valves and receivers for the liquid return side of the refrigerant piping. 4 InRoom Precision AC Tech Data Manual Condensate Pump a a 7 6 7 8 5 2 8 a 2 n a n 60 Hz 50 Hz Model # ACAC75107 ACAC75107 ACAC76106 Hz 60 60 50 Height mm (in) 259 (10 1/8) 259 (10 1/8) 210 (8 1/4) Width mm (in) 152 (6) 152 (6) 132 (5 1/4) Length 304 (12) 304 (12) 295 (11 1/2) Outlet mm (in) 13 (1/2) 13 (1/2) 6 (1/4) Volts 230 460 400 Amps 1.9 0.8 0.125 Watts 360 360 30 Weight Kg (Lb) Ea 5.8 (13) 5.8 (13) 3 (6.6) HP (motor only) 1/5 1/5 1/20 Tank Capacity Ltr (Gal) 3.785 (1) 3.785 (1) 1.4 (1/3) Model Liters (Gallons) per hour at 60 Hz/Rated Voltage Flow rate per pressure drop 1 ft 5 ft 10 ft 15 ft 20 ft 30 ft 40 ft ACAC75107 1839 (486) 1714 (453) 1559 (412) 1407 (372) 1275 (337) 942 (249) 635 (168) ACAC75108 1589 (420) 1438 (380) 1343 (355) 1248 (330) 1173 (310) 908 (240) 548 (145) Model Liters (Gallons) per hour at 50 Hz/Rated Voltage - Flow rate per pressure drop 1 m 2 m 3 m 4 m ACAC76106 135 (35.5) 100 (26.4) 60 (15.8) 20 (5.3) InRoom Precision AC Tech Data Manual 5 Upflow Discharge Plenums for 50 Hz and 60 Hz InRoom Cooling Units a 4 7 8 2 a n Upflow discharge plenums Cabinet size SKU Width mm (in) Depth mm (in) Height mm (in) 1 ACPL75100 1000 (39.37) 900 (35) 500 (19.7) 2 ACPL75101 1400 (55.11) 3 ACPL75102 1750 (68.90) 4 ACPL75103 2150 (84.65) 5 ACPL75104 2550 (100.39) Note: Plenums are delivered completely assembled. 6 InRoom Precision AC Tech Data Manual Downflow Discharge Plenums for 50 Hz InRoom Cooling Units a 6 2 0 3 a n Cabinet size SKU Width mm (in) Depth mm (in) Height mm (in) Unit Sub Base Plenum with no Grills 1 ACSB76100 960 (37.8) 865 (34) 450 (17.7) 2 ACSB76101 1360 (53.5) 3 ACSB76102 1710 (67.3) 4 ACSB76103 2110 (83.1) 5 ACSB76104 2510 (98.8) Unit Sub Base Plenum with Grills 1 ACSB76110 960 (37.8) 865 (34) 450 (17.7) 2 ACSB76111 1360 (53.5) 3 ACSB76112 1710 (67.3) 4 ACSB76113 2110 (83.1) 5 ACSB76114 2510 (98.8) Unit Sub Base Plenum with Damper (50Hz only) 1 ACSB76120 960 (37.8) 865 (34) 450 (17.7) 2 ACSB76121 1360 (53.5) 3 ACSB76122 1710 (67.3) 4 ACSB76123 2110 (83.1) 5 ACSB76124 2510 (98.8) Unit Sub Base Plenum with Flex Connector (not shown) 1 ACSB76130 960 (37.8) 865 (34) 450 (17.7) 2 ACSB76131 1360 (53.5) 3 ACSB76132 1710 (67.3) 4 ACSB76133 2110 (83.1) 5 ACSB76134 2510 (98.8) Note: • All three sub-base plenum models are attached to the cooling unit with 4x M10 screws. • Sub-base plenums with grills are equipped with adjustable horizontal fins to direct exiting air. • The plenums can be installed with the opening to the front or with the opening to the rear. InRoom Precision AC Tech Data Manual 7 Standard Floorstands for InRoom 60Hz Cooling Units a 4 3 8 2 a n Cabinet size Model Height mm (in) Width mm (in) Depth mm (in) 1 ACFS76000 254 (10) 960 (37.8) 864 (34) ACFS76001 305 (12) ACFS76002 381 (15) ACFS76003 457 (18) ACFS76004 609 (24) 2 ACFS76005 254 (10) 1359 (53.5) 864 (34) ACFS76006 305 (12) ACFS76007 381 (15) ACFS76008 457 (18) ACFS76009 609 (24) 3 ACFS76010 254 (10) 1712 (67.4) 864 (34) ACFS76011 305 (12) ACFS76012 381 (15) ACFS76013 457 (18) ACFS76014 609 (24) 4 ACFS76015 254 (10) 2108 (83.0) 864 (34) ACFS76016 305 (12) ACFS76017 381 (15) ACFS76018 457 (18) ACFS76019 609 (24) 5 ACFS76020 254 (10) 2512 (98.9) 864 (34) ACFS76021 305 (12) ACFS76022 381 (15) ACFS76023 457 (18) ACFS76024 609 (24) 8 InRoom Precision AC Tech Data Manual Bowling Alley Floorstands for InRoom 60Hz Cooling Units a 3 5 0 3 a n Cabinet size Model Height mm (in) Width mm (in) Depth mm (in) 1 ACFS76033 305 (12) 960 (37.8) 864 (34) ACFS76032 381 (15) ACFS76031 457 (18) ACFS76030 609 (24) 2 ACFS76037 305 (12) 1359 (53.5) 864 (34) ACFS76036 381 (15) ACFS76035 457 (18) ACFS76034 609 (24) 3 ACFS76041 305 (12) 1712 (67.4) 864 (34) ACFS76040 381 (15) ACFS76039 457 (18) ACFS76038 609 (24) 4 ACFS76045 305 (12) 2108 (83.0) 864 (34) ACFS76044 381 (15) ACFS76043 457 (18) ACFS76042 609 (24) 5 ACFS76049 305 (12) 2512 (98.9) 864 (34) ACFS76048 381 (15) ACFS76047 457 (18) ACFS76046 609 (24) InRoom Precision AC Tech Data Manual 9 Floorstands for InRoom 50 HzCooling Units a 7 8 0 3 a n Cabinet size Model Height mm (in) Width mm (in) Depth mm (in) 1 ACFS76025 250-500 (10-20) 960 (37.8) 864 (34) 2 ACFS76026 250-500 (10-20) 1359 (53.5) 864 (34) 3 ACFS76027 250-500 (10-20) 1712 (67.4) 864 (34) 4 ACFS76028 250-500 (10-20) 2108 (83.0) 864 (34) 5 ACFS76029 250-500 (10-20) 2512 (98.9) 864 (34) 10 InRoom Precision AC Tech Data Manual Condensers Air cooled condensers are designed to reject heat from refrigerant based cooling equipment and are designed to be installed outdoors. The condensers are self-contained in a lighweight aluminum cabinet designed for mounting to a horizontal surface. The cabinet houses condenser coils and fan assemblies. Each condenser coil is a copper turb, aluminum finned coil. The capacity of the condenser is based on the rated capacity of the coil. In the case of dual circuit units, the model number is based on the combined capacity of both coils. The coil is a closed-loop refrigerant condensing heat exchanger in which refrigerant is continuously circulated by the pressure differential created by a compressor. The compressor increases refrigerant pressure to a level sufficiently high for it to be cooled and condensed into liquid by the effect of ambient air being drawn over the condenser coil. The fans have corrosion resistant, multi-blade impellers designed for high aerodynamic efficiency which results in lower power consumption, lower noise levels and longer life. Each fan utilizes a direct driven motor with maintenance free bearings. The fan motors are internally protected from overload. Fans have finger guard grilles to protect operators from injury and keep large tools or other objects from falling into the fan. Electrical controls are in a weather proof enclosure and isolated from the rest of the equipment. The electrical box has a removable front access panel which is safety interlocked with the service disconnect switch, preventing the panel from being removed when the switch is in the ON position. The switch must be turned off to gain access to the electrical components. 60 Hz a 2 1 0 3 a n InRoom Precision AC Tech Data Manual 11 InRoom Standard Condensers - 60 Hz InRoom Remote Outdoor Condenser Data, 95°F ambient, 120°F condensation - R407C InRoom Cabinet Size 1 2 3 4 5 Total Heat Rejection (THR) BTU/h 96.219 165.496 225.435 279.262 380.436 CFM 8,394 19,325 18,609 17,604 27,963 Fan Diameter - in 19.69 24.80 24.80 24.80 24.80 Voltage Options 208-230/3/60 ACCD76000 ACCD76004 ACCD76008 ACCD76012 ACCD76016 Number of Fans 2 2 2 2 3 Fan RPM (Qty) 1490 1585(1), 1500(1) 1585(1), 1500(1) 1585(1), 1500(1) 1585(2), 1500(1) Motor HP (Qty) 1.23 Hp(2) 3.58(1), 3.85(1) 3.58(1), 3.85(1) 3.58(1), 3.85(1) 3.58(2), 3.85(1) Electrical Data FLA 8.6 19.7 19.7 19.7 29.1 MCA 9.8 22.1 22.1 22.1 31.5 MFS 15 30 30 30 40 460-480/3/60 ACCD76010 ACCD76005 ACCD76009 ACCD76013 ACCD76017 Number of Fans 2 2 2 2 3 Fan RPM (Qty) 1450(1), 1570(1)1650(1), 1500(1) 1650(1), 1500(1) 1650(1), 1500(1) 1650(2), 1500(1) Motor HP (Qty) 1.34(1), 1.64(1) 3.90(1), 3.85(1) 3.90(1), 3.85(1) 3.90(1), 3.85(1) 3.90(2), 3.85(1) Electrical Data FLA 3.9 9.5 9.5 9.5 14.57 MCA 4.3 10.7 10.7 10.7 15.85 MFS 15 15 15 15 20 575-600/3/60 ACCD76022 ACCD76023 ACCD76024 ACCD76025 ACCD76026 Number of Fans 2 2 2 2 3 Fan RPM (Qty) 1450(1), 1570(1)1650(1), 1500(1) 1650(1), 1500(1) 1650(1), 1500(1) 1650(2), 1500(1) Motor HP (Qty) 1.34(1), 1.64(1) 3.90(1), 3.85(1) 3.90(1), 3.85(1) 3.90(1), 3.85(1) 3.90(2), 3.85(1) Electrical Data FLA 3.4 8.0 8.0 8.0 12.3 MCA 37 9.0 9.0 9.0 13.4 MFS 15.0 15.0 15.0 15.0 15.0 Refrigerant Connections* Hot Gas Line - in 1 1/8 OD 1 1/8 OD 1 3/8 OD 1 3/8 OD 1 5/8 OD Liquid Line - in 7/8 OD 7/8 OD 1 1/8 OD 1 1/8 OD 1 3/8 OD Physical Data** Dimensions -HxWxD in 35.5x32.75x76 48x108.5x48.25 48x108.5x48.25 48x108.5x48.25 48x155.5x48.25 Approximate Weight - lb. 240 455 495 555 835 * Condenser connections may not represent actual line sizing. ** Dimensions are overall. Electrical enclosure and fan guard are included. Actual fan guard height is 4 in. Actual electrical enclosure depth is 6.5 in. 12 InRoom Precision AC Tech Data Manual InRoom Low Temperature (-30ºF) Condensers - 60 Hz InRoom Remote Outdoor Condenser Data, 95°F ambient, 120°F condensation - R407C InRoom Cabinet Size 1 2 3 4 5 Total Heat Rejection (THR) BTU/h 96.219 165.496 225.435 279.262 380.436 CFM 8,394 19,325 18,609 17,604 27,963 Fan Diameter - in 19.69 24.80 24.80 24.80 24.80 Voltage Options 208-230/3/60 ACCD76032 ACCD76033 ACCD76034 ACCD76035 ACCD76036 Number of Fans 2 2 2 2 3 Fan RPM (Qty) 1490 1585(1), 1500(1) 1585(1), 1500(1) 1585(1), 1500(1) 1585(2), 1500(1) Motor HP (Qty) 1.23(2) 3.58(1), 3.85(1) 3.58(1), 3.85(1) 3.58(1), 3.85(1) 3.58(2), 3.85(1) Electrical Data FLA 8.6 19.7 19.7 19.7 29.1 MCA 9.8 22.1 22.1 22.1 31.5 MFS 15 30 30 30 40 460-480/3/60 ACCD76037 ACCD76038 ACCD76039 ACCD76040 ACCD76041 Number of Fans 2 2 2 2 3 Fan RPM (Qty) 1450(1), 1570(1)1650(1), 1500(1) 1650(1), 1500(1) 1650(1), 1500(1) 1650(2), 1500(1) Motor HP (Qty) 1.34(1), 1.64(1) 3.90(1), 3.85(1) 3.90(1), 3.85(1) 3.90(1), 3.85(1) 3.90(2), 3.85(1) Electrical Data FLA 3.9 9.5 9.5 9.5 14.57 MCA 4.3 10.7 10.7 10.7 15.85 MFS 15 15 15 15 20 575-600/3/60 ACCD76042 ACCD76043 ACCD76044 ACCD76045 ACCD76046 Number of Fans 2 2 2 2 3 Fan RPM (Qty) 1450(1), 1570(1)1650(1), 1500(1) 1650(1), 1500(1) 1650(1), 1500(1) 1650(2), 1500(1) Motor HP (Qty) 1.34(1), 1.64(1) 3.90(1), 3.85(1) 3.90(1), 3.85(1) 3.90(1), 3.85(1) 3.90(2), 3.85(1) Electrical Data FLA 3.7 8.3 8.3 8.3 12.8 MCA 4.0 9.3 9.3 9.3 13.9 MFS 15.0 15.0 15.0 15.0 15.0 Low Ambient Kit ACCD76106 ACCD76107 ACCD76109(2) ACCD76106(2) ACCD76107(2) Refrigerant Connections* Hot Gas Line - in 1 1/8 OD 1 1/8 OD 1 3/8 OD 1 3/8 OD 1 5/8 OD Liquid Line - in 7/8 OD 7/8 OD 1 1/8 OD 1 1/8 OD 1 3/8 OD Physical Data** Dimensions -HxWxD in 35.5x32.75x76 48x108.5x48.25 48x108.5x48.25 48x108.5x48.25 48x155.5x48.25 Approximate Weight - lb. 240 455 495 555 835 each * Condenser connections may not represent actual line sizing. ** Dimensions are overall. Electrical enclosure and fan guard are included. Actual fan guard height is 4 in. Actual electrical enclosure depth is 6.5 in. InRoom Precision AC Tech Data Manual 13 InRoom High Temperature Condensers - 60 Hz InRoom Remote Outdoor Condenser Data, 105°F ambient, 125°F condensation - R407C InRoom Cabinet Size 1 2 3 4 5 Total Heat Rejection (THR) BTU/h 154,105 247,501 331,845 448,600 331,845 (2) CFM 19,325 17,604 27,791 25,227 27,791 (2) Fan Diameter - in 25.60 25.60 25.60 25.60 25.60 Voltage Options 208-230/3/60 ACCD76004 ACCD76006 ACCD76016 ACCD76014 ACCD76020(2) Number of Fans 2 2 3 3 3 Fan RPM (Qty) 1585(1), 1500(1) 1585(1), 1500(1) 1585(2), 1500(1) 1585(1), 1350(1) 1585(2), 1500(1) Motor HP (Qty) 3.58(1), 3.85(1) 3.58(1), 3.85(1) 3.58(2), 3.85(1) 3.58(2), 3.75(1) 3.58(2), 3.75(1) Electrical Data FLA 19.7 19.7 29.1 29.1 29.1 MCA 22.1 22.1 31.5 31.5 31.5 MFS 30 30 40 40 40 460-480/3/60 ACCD76005 ACCD76007 ACCD76017 ACCD76015 ACCD76021(2) Number of Fans 2 2 3 3 3 Fan RPM (Qty) 1650(1), 1500(1) 1650(1), 1500(1) 1650(2), 1500(1) 1650(2), 1350(1) 1650(2), 1500(1) Motor HP (Qty) 3.90(1), 3.85(1) 3.90(1), 3.85(1) 3.90(2), 3.85(1) 3.90(2), 3.75(1) 3.90(2), 3.85(1) Electrical Data FLA 9.5 9.5 14.57 14.57 14.57 MCA 10.7 10.7 15.85 15.85 15.85 MFS 15 15 20 20 20 575-600/3/60 ACCD76027 ACCD76028 ACCD76029 ACCD76030 ACCD76031(2) Number of Fans 2 2 3 3 3 Fan RPM (Qty) 1650(1), 1500(1) 1650(1), 1500(1) 1650(2), 1500(1) 1650(2), 1350(1) 1650(2), 1500(1) Motor HP (Qty) 3.90(1), 3.85(1) 3.90(1), 3.85(1) 3.90(2), 3.85(1) 3.90(2), 3.75(1) 3.90(2), 3.85(1) Electrical Data FLA 8.0 8.0 12.3 12.3 12.3 (2) MCA 9.0 9.0 13.4 13.4 13.4 (2) MFS 15.0 15.0 15.0 15.0 15.0 Refrigerant Connections* Hot Gas Line - in 1 1/8 OD 1 5/8 OD 1 5/8 OD 1 5/8 OD 2 1/8 OD Liquid Line - in 7/8 OD 1 3/8 OD 1 3/8 OD 1 3/8 OD 2 1/8 OD Physical Data** Dimensions -HxWxD in 48x108.5x48.25 48x108.5x48.25 48x155.5x48.25 48x155.5x48.25 48x155.5x48.25 Approximate Weight - lb. 455 555 835 1000 835 (2) * Condenser connections may not represent actual line sizing. ** Dimensions are overall. Electrical enclosure and fan guard are included. Actual fan guard height is 4 in. Actual electrical enclosure depth is 6.5 in. 14 InRoom Precision AC Tech Data Manual InRoom Condensers - 50 Hz 50 Hz a 6 5 8 2 a n InRoom Remote Outdoor Condenser Data, 97°F ambient, 120°F condensation - R407C InRoom Cabinet Size 1 2 3 4 5 Condenser Model (Qty) ACCD76002 ACCD76003 ACCD76002 (2) ACCD76003 (2) ACCD76011(2) Voltage 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Number of Fans 2 2 3 3 3 Airflow m3/h (cfm) 13600 (8024) 13000 (7670) 13600 (8024) each 13000 (7670) each 16800 (9912) each Motor kW (HP) - 2 x 0.69 (2 x 0.92) 2 x 0.69 (2 x 0.92) 2 x 0.69 (2 x 0.92) 2 x 0.69 (2 x 0.92) 3 x 0.69 (3 x 0.92) Refrigerant Connections* Hot Gas Line - in 7/8 OD 7/8 OD 7/8 OD 1 3/8 OD 7/8 OD Liquid Line - in 7/8 OD 7/8 OD 7/8 OD 7/8 OD 7/8 OD Weight - kg (lb) 72 (158) 81 (178) 2 x 72 (2 x 158) 2 x 81 (2 x 178) 2 x 144 (2 x 317) InRoom Remote Outdoor Condenser Data, 115°F ambient, 131°F condensation - R407C Condenser Model (Qty) ACCD76003 ACCD76011 ACCD76001 (2) ACCD76011 (2) ACCD76019(2) Voltage 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Number of Fans 2 2 3 3 3 Airflow m3/h (cfm) 13000 (7670) 16800 (9912) 13000 (7670) each 16800 (9912) each 24000 (14160) each Motor kW (HP) - 2 x 0.69 (2 x 0.92) 3 x 0.69 (3 x 0.92) 2 x 0.69 (2 x 0.92) 2 x 0.69 (2 x 0.92) 3 x 0.62 (3 x 0.83) Refrigerant Connections* Hot Gas Line - in 7/8 OD 7/8 OD 7/8 OD 7/8 OD 1 3/8 OD Liquid Line - in 7/8 OD 7/8 OD 7/8 OD 7/8 OD 7/8 OD Weight - kg (lb) 81 (178) 144 (317) 2 x 81 (2 x 178) 2 x 144 (2 x 317) 2 x 200 (2 x 440) * Condenser connections may not represent actual line sizing. InRoom Precision AC Tech Data Manual 15 Receivers Conformance. Each receiver conforms to UL, CSA or ASME requirements for 450 psi maximum working pressure. Models with an internal diameter under six inches are UL listed. All larger models are made according to ASME code and labeled appropriately. Pumpdown and refrigerant charge. All pumpdowns are calculated at 80% capacity of liquid. Approximately 10% of pumpdown capacity is required to operate the receiver properly. Pumpdown = (overall length – length correction) x (pumpdown per inch) Overall length = (pumpdown required / pumpdown per inch) = (length correction) 60 Hz S (Safety) P (Refrigerant Inlet) Q (Refrigerant Outlet) A B H a 2 9 8 Dna2 InRoom Cabinet Size 1 2 3 4 5 60 Hz Air-Cooled Condenser Model ACCD76032 ACCD76037 ACCD76042 ACCD76033 ACCD76038 ACCD76043 ACCD76034 ACCD76039 ACCD76044 ACCD76035 ACCD76040 ACCD76045 ACCD76036 ACCD76041 ACCD76046 60 Hz Receiver Model (Qty) ACAC76106 ACAC76107 ACAC76109 (2) ACAC76106 (2) ACAC76107 (2) Pumpdown capacities for R 407C kg (lb) * 11.79 (26) 19.58 (44) 8.1 (18) each 11.79 (26) each 27.7 (61) each Length correction mm (in) 45.7 (1.8) 58.4 (2.3) 45.7 (1.8) 45.7 (1.8) 66 (2.6) End to weld mm (in) 79.4 (3 1/8) 114.3 (4 1/2) 79.4 (3 1/8) 79.4 (3 1/8) 139.7 (5 1/2) D (OD) mm (in) 219 (8 5/8) 273 (10 3/4) 219 (8 5/8) 219 (8 5/8) 324 (12 3/4) H mm (in) 406.4 (16) 457.2 (18) 304.8 (12) 406.4 (16) 457.2 (18) A mm (in) 127 (5) 152.4 (6) 127 (5) 127 (5) 168.2 (6 5/8) B mm (in) 279.4 (11) 292.1 (11 1/2) 177.8 (7) 279.4 (11) 288.8 (11 3/8) P (ID) mm (in) 15.9 (5/8) 28.4 (1 1/8) 15.9 (5/8) 15.9 (5/8) 28.4 (1 1/8) Q (ID) mm (in) 15.9 (5/8) 22.2 (7/8) 15.9 (5/8) 15.9 (5/8) 28.4 (1 1/8) S (FPT) mm (in) 9.5 (3/8) 22.2 (7/8) 9.5 (3/8) 9.5 (3/8) 12.7 (1/2) Shipping Weight kg (lb) 15.87 (35) 27.2 (60) 13.15 (29) each 15.87 (35) each 36.28 (80) each Receiver Heater Watts 125 125 200 125 (2) 125 (2) Heater Width - mm (in) 25 (1) 25 (1) 25 (1) 25 (1) 25 (1) Heater Length - mm (in) 635 (25) 635 (25) 1015 (40) 635 (25) 635 (25) Lead Length - mm (in) ** 305 (12) 305 (12) 305 (12) 305 (12) 305 (12) Thermostat Setting 60/75 60/75 60/75 60/75 60/75 * All pumpdowns are calculated at 80% of receiver volume. ** 12 inches, UL 1180, Teflon® silicon rubber wire, round elements, rated @ 5 Watts per square inch 16 InRoom Precision AC Tech Data Manual InRoom Receivers - 50 Hz 50 Hz InRoom Cabinet Size 1 2 3 4 5 50 Hz Air-Cooled Condenser Model ACCD76002 ACCD76003 ACCD76002 (2) ACCD76003 (2) ACCD76011 (2) 50 Hz Receiver Model (Qty) ACAC76101 ACAC76102 ACAC76103 (2) ACAC76104 (2) ACAC76105 (2) Max Refrigerant Charge 90% at 20°C (68°F) R-407C kg (lb) * 24.0 (53) 24.0 (53) 24.0 (53) each 24.0 (53) each 24.0 (53) each Connection inlet - mm (in) 22 (7/8) 22 (7/8) 22 (7/8) 22 (7/8) 22 (7/8) Connection thread/flange 1 1/4 in (12 UNF) 1 1/4 in (12 UNF) 1 1/4 in (12 UNF) 1 1/4 in (12 UNF) 1 1/4 in (12 UNF) Connection outlet - mm (in) 22 (7/8) 22 (7/8) 22 (7/8) 22 (7/8) 22 (7/8) Gauge 7/16 (20 UNF) 7/16 (20 UNF) 7/16 (20 UNF) 7/16 (20 UNF) 7/16 (20 UNF) Pressure relief valve connection 1 1/4 in (12 UNF) 1 1/4 in (12 UNF) 1 1/4 in (12 UNF) 1 1/4 in (12 UNF) 1 1/4 in (12 UNF) Height - mm (in) 287 (11.3) 287 (11.3) 287 (11.3) each 287 (11.3) each 287 (11.3) each Depth - mm (in) 276 (10.9) 276 (10.9) 276 (10.9) each 276 (10.9) each 276 (10.9) each Width - mm (in) 824 (32.4) 824 (32.4) 824 (32.4) each 824 (32.4) each 824 (32.4) each Weight - kg (lb) 23.6 (52) 23.6 (52) 23.6 (52) each 23.6 (52) each 23.6 (52)each InRoom Precision AC Tech Data Manual 17 Display Interface The display interface is standard on each system. The display interface provides precision control for the demanding requirements of these environments: • Data centers • Control rooms • Clean rooms • Switch rooms a • UPS rooms 3 7 7 2 a n The easy-to-use display allows the operator to select options from the display interface to control and monitor the InRoom precision air conditioning system. Logging The display interface displays the most recent alarms. Each alarm log contains a time/date stamp as well as operating conditions at the time of occurrence. The display interface also displays run time, in hours, for major components (compressors, heaters, humidifier, fans). Control Type The display interface utilizes proportional and integral derivative (PID), a time-proven precision environmental control method. This allows for custom tuning of control variables to achieve the desired system response. Functions • Audible and Visual Alarms • Sensor Status (Temperature, Humidity, and Pressure) • Component State (On/Off, %) • Component Runtimes • Event Logging • Configuration and Alarm Settings • Password Protection Open Architecture The InRoom precision air conditioning system is open for integration with all building management systems. The display interface on the system supports Modbus RTU RS485. Alarms • Local Stop • Compressor Low Pressure • Compressor Failure • E-heating Failure • Humidifier Failure • Humidifier 5uS • Humidifier 20uS • Fan Error • Filter Clocked • External Alarm • Pump Failure • Drycooler Failure • Water Detector • Room Temp Too High • Room Humidity Too High • Supply Temp Too High • Supply Humidity Too High • Room Temp Too Low • Room Humidity Too Low • Supply Temp Too Low • Supply Humidity Too Low • Water Temp Too High • Water Temp Too Low • Fire/Smoke Detector • Sensor Failure • Sensor Broken 18 InRoom Precision AC Tech Data Manual InRoom Model Sizes Different variations of the InRoom product range are defined by the airflow direction, the number of refrigerant circuits, and the type of cooling system. There are five cabinet sizes. The front service access for all cabinet sizes of the InRoom Precision Air Conditioner is 1 m (39 in). The InRoom Fluid Cooled (Glycol) system with Economizer Coil differs from the other versions by having a larger cabinet size, not a larger capacity. There are no Fluid Cooled (Glycol ) systems with Economizer Coils in Cabinet Size 1. 12 3 4 5 1980 (77.95) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) 2550 (100.39) 1980 (77.95) a 5 3 8 2 a n *Dimensions are in mm (in). Depth of all models is 890 mm (35 in). InRoom Direct Expansion Model Sizes Cabinet Size 1 2 3 4 5 1 refrigerant circuit PA211 PG211 PACW211 PGCW211 PA311 PG311 PACW311 PGCW311 2 refrigerant circuits PA452 PG452 PACW452 PGCW452 PA612 PG612 PACW612 PGCW612 PA862 PG862 PACW862 PGCW862 InRoom Fluid Cooled (Glycol) with Economizer Model Sizes 1 refrigerant circuit PGE211 PGE311 2 refrigerant circuits PGE452 PGE612 InRoom Chilled Water Model Sizes PCW400 PCW660 PCW900 PCW1100 PCW1500 InRoom Precision AC Tech Data Manual 19 InRoom Cooling Unit Configurations Fluid Cooled (Glycol) InRoom Fluid Cooled (Glycol) systems are completely charged and factory tested in a sealed system for reliability. In mid to low ambient climates, an economizer coil can be used to increase efficiency and extend compressor life. Economizer operation greatly reduces the energy consumption of the system. Water regulating valves control head pressure. • System is used with a fluid cooler. • Factory-tested as a sealed system. • Eliminates the need for field refrigerant piping. • No requirement for water treatment. • Economizer option provides high efficiency. a 7 3 8 2 a n • Low maintenance. The InRoom Fluid Cooled (Glycol) System with Economizer is configured with both the glycol factory sealed system and an Economizer coil. During cold ambient conditions, the compressorized system will shut down and utilize the cold outdoor air to cool the glycol system, rerouting it from the heat exchanger to the Economizer coil for efficient operation. Fluid Cooled (Glycol) System a 6 3 8 2 a n Fluid Cooled (Glycol) System with Economizer 20 InRoom Precision AC Tech Data Manual The InRoom Fluid Cooled (Glycol) System with Chilled Water System is a combination of a factory sealed glycol system and a chilled water system and contains two separate cooling coils. The controller microprocessor manages the systems to allow the glycol system to operate as standby to the chilled water system or vice versa, giving the added security of back-up cooling to the computer room. a 3 4 8 2 a n Chilled Water InRoom Chilled Water systems are available in a packaged fan-coil design. Room air is recirculated through the cooling coil, which transfers the heat load directly into the chilled water ring main. Water flow rate is regulated by a 2- or 3-way valve controlled by the controller microprocessor. Cooling towers are used as a source of heat rejection and can be used to serve multiple indoor units. Towers utilizing outdoor air require water treatment. • The system is used with a cooling tower or other source of water. • Factory sealed and tested system. • The need for field refrigerant piping is eliminated. Fluid Cooled (Glycol) System with Chilled Water Cooling System a 4 4 8 2 a n Chilled Water Cooling System InRoom Precision AC Tech Data Manual 21 Air Cooled (DX) Air cooled systems are not pre-charged from the factory and require field refrigerant piping. Each installation requires an engineered piping solution. APC strongly recommends installation by a highly qualified refrigeration contractor to avoid improper elevation and long piping runs. The Air Cooled system uses refrigerant as the heat transfer medium. Room air recirculates through the InRoom unit which houses the evaporator coil, scroll compressor, and refrigeration system. A remotely mounted air cooled condenser is connected to the unit. The sealed refrigeration circuit will absorb the room heat load and reject it to the outside atmosphere. • System used with a remote air cooled condenser • Field installed refrigerant piping is required • Low maintenance The MultiCool System is a combination of the Air Cooled System and the Chilled Water System and contains two separate cooling coils. The controller microprocessor manages the MultiCool System to allow the air cooled by the Air Cooled system to operate as a standby system to the Chilled Water (CW) system or vice versa, giving the added security of back-up cooling to the computer room. a 5 4 8 2 a n Air Cooled System a 6 4 8 2 a n MultiCool - Air Cooled System with Chilled Water Cooling System 22 InRoom Precision AC Tech Data Manual 60Hz Performance Specifications Chilled Water (CW) – 60Hz Chilled Water PCW400 Cabinet Size 1 PCW660 Cabinet Size 2 PCW900 Cabinet Size 3 PCW1100 Cabinet Size 4 PCW1500 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 53.6 (182,800) 86.1 (293,800) 120.1 (409,800) 153.4 (553,400) 197.8 (675,000) Sensible - kW (BTU/hr) 35.8 (128,999) 58.4 (206,099) 82.7 (288,999) 102.4 (356,199) 134.3 (465,099) Flow Rate - L/m (GPM) 139.3 (36.8) 229.4 (60.6) 324.0 (85.6) 410.3 (108.4) 534.1 (141.0) Total Pressure Drop Water Side - Kpa (ft) 91.8 (30.7) 129.2 (43.2) 112.1 (37.5) 124.7 (41.7) 189.0 (63.2) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 29.4 (100,300) 54.5 (186,000) 65.5 (223,500) 82.5 (281,500) 104.8 (357,600) Sensible - kW (BTU/hr) * 25.5 (93,799) 45.5 (162,099) 59.1 (208,499) 73.9 (258,999) 95.3 (331,999) Flow Rate - L/m (GPM) 80.3 (21.2) 147.6 (39.0) 182.8 (48.3) 227.1 (60.0) 293.4 (77.5) Total Pressure Drop Water Side - Kpa (ft) 29.6 (9.9) 62.8 (21.0) 38.9 (13.0) 43.4 (14.5) 59.8 (20.0) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 29.9 (102,000) 49.8 (169,900) 66.3 (226,200) 82.2 (280,500) 105.8 (361,000) Sensible - kW (BTU/hr) 27.9 (101,999) 47.8 (169,899) 64.3 (226,199) 80.2 (280,499) 103.8 (360,999) Flow Rate - L/m (GPM) 81.4 (21.5) 135.5 (35.8) 185.1 (48.9) 226.4 (59.8) 296.0 (78.2) Total Pressure Drop Water Side - Kpa (ft) 31.4 (10.5) 52.3 (17.5) 39.5 (13.2) 43.1 (14.54) 60.4 (20.2) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 25.0 (85,300) 42.0 (143,300) 54.8 (187,000) 68.2 (232,700) 86.3 (294,500) Sensible - kW (BTU/hr) 23.0 (85,299) 40.0 (143,299) 52.8 (186,999) 66.2 (232,699) 84.3 (294,499) Flow Rate - L/m (GPM) 68.9 (18.2) 115.1 (30.4) 155.2 (41.0) 190.0 (50.2) 245.7 (64.9) Total Pressure Drop Water Side - Kpa (ft) 22.4 (7.5) 39.8 (13.3) 28.4 (9.5) 31.1 (10.4) 42.5 (14.2) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 25.0 (85,300) 42.0 (143,300) 54.8 (187,000) 68.2 (232,700) 86.3 (294,500) Sensible - kW (BTU/hr) 23.0 (85,299) 40.0 (143,299) 52.8 (186,999) 66.2 (232,699) 84.3 (294,499) Flow Rate - L/m (GPM) 68.9 (18.2) 115.1 (30.4) 155.2 (41.0) 190.0 (50.2) 245.7 (64.9) Total Pressure Drop Water Side - Kpa (ft) 22.4 (7.5) 39.8 (13.3) 28.4 (9.5) 31.1 (10.4) 42.5 (14.2) 21.1°C DB, 14.0°C WB(70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 21.7 (74,000) 36.6 (124,900) 47.0 (160,400) 58.5 (199,600) 72.9 (248,700) Sensible - kW (BTU/hr) 19.7 (73,999) 34.6 (124,899) 45.0 (160,399) 56.5 (199,599) 70.9 (248,699) Flow Rate - L/m (GPM) 60.6 (16.0) 101.1 (26.7) 135.1 (35.7) 165.0 (43.6) 210.8 (55.7) Total Pressure Drop Water Side - Kpa (ft) 16.7 (5.6) 32.6 (10.9) 23.0 (7.7) 25.7 (8.6) 31.7 (10.6) 21.1°C DB, 14.0°C WB(70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 21.7 (74,000) 36.6 (124,900) 47.0 (160,400) 58.5 (199,600) 72.9 (248,700) Sensible - kW (BTU/hr) 19.7 (73,999) 34.6 (124,899) 45.0 (160,399) 56.5 (199,599) 70.9 (248,699) Flow Rate - L/m (GPM) 60.6 (16.0) 101.1 (26.7) 135.1 (35.7) 165.0 (43.6) 210.8 (55.7) Total Pressure Drop Water Side - Kpa (ft) 16.7 (5.6) 32.6 (10.9) 23.0 (7.7) 25.7 (8.6) 31.7 (10.6) Valve Size - mm (in) 32 (1 1/4) 38.1 (1.5) 50 (2.0) 50 (2.0) 50 (2.0) Temperature medium in - °C (°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) Temperature medium in - °C (°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) Chilled Water Coil Face Area - m² (ft²) 1.09 (11.77) 1.66 (17.82) 1.53 (16.52) 1.94 (20.86) 2.31 (24.88) Rows Deep 5 5 5 5 5 Face Velocity - m/min (ft/min) 130 (428) 132 (432) 112 (367) 102 (336) 114 (373) * Nominal Rating Point InRoom Precision AC Tech Data Manual 23 Chilled Water Continued PCW400 Cabinet Size 1 PCW660 Cabinet Size 2 PCW900 Cabinet Size 3 PCW1100 Cabinet Size 4 PCW1500 Cabinet Size 5 Fan Information Number of Fans 1 1 2 2 3 Air Flow - M³/hr (CFM) 8495 (5,000) 12997 (7,650) 18995 (11,180) 22002 (12,950) 29495 (17,360) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 72.1 75.2 71.0 74.4 73.10 Total Fan Power Consumption - kW (hp) 1.7 (2.3) 2.6 (3.5) 5.3 (7.1) 5.4 (7.2) 8.8 (11.8) Connection Sizes Upflow Chilled Water In/Out - mm (in) 35 (1 3/8) 42 (1 5/8) 54 (2 1/8) 70 (2 3/4) 70 (2 3/4) Downflow Chilled Water In/Out - mm (in) 35 (1 3/8) 42 (1 5/8 54 (2 1/8) 54 (2 1/8) 54 (2 1/8) Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU/hr) - Includes Motor Heat 460 V 12.0 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) 230 V 9.0 (30736.8) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) Number of Stages 1 2 2 3 3 Downflow Filters - mm Quantities 836 x 546 x 92 G4 N/A N/A 3 3 3 836 x 393 x 92 G4 N/A 1 N/A 1 2 836 x 446 x 92 G4 2 2 N/A N/A N/A Upflow Filters - mm Quantities 795 x 508 x 92 G4 N/A N/A 1 2 2 795 x 341 x 92 G4 1 1 N/A 1 1 795 x 333 x 92 G4 N/A 1 N/A N/A 1 795 x 365 x 92 G4 N/A N/A 1 1 1 795 x 516 x 92 G4 N/A N/A 1 N/A N/A 795 x 502 x 92 G4 1 1 N/A N/A N/A Physical Data Weight - kg (lb) 307 (677) 362 (798) 547 (1206) 568 (1252) 755 (1664) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.12) 1750 (68.90) 2150 (84.65) 2550 (100.39) Depth - mm (in) 890 (35) 890 (35) 890.0 (35) 890.0 (35) 890 (35) 24 InRoom Precision AC Tech Data Manual Air Cooled (DX) System – 60Hz Air Cooled PA211 Cabinet Size 1 PA311 Cabinet Size 2 PA452 Cabinet Size 3 PA612 Cabinet Size 4 PA862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 19.8 (67,450) 29.9 (102,000) 44.2 (151,000) 55.2 (188,290) 84.9 (290,000) Sensible - kW (BTU/hr) 19.8 (67,450) 29.9 (102,000) 41.3 (141,000) 55.2 (188,290) 75.4 (257,000) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 18.1 (61,940) 27.6 (94,000) 40.5 (138,000) 50.8 (173,470) 78.8 (269,000) Sensible - kW (BTU/hr) * 18.1 (61,940) 27.6 (94,000) 40.5 (138,000) 50.8 (173,470) 72.8 (249,000) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 18.1 (61,940) 27.6 (94,000) 40.5 (138,000) 50.8 (173,470) 77.2 (264,000) Sensible - kW (BTU/hr) 18.1 (61,940) 27.6 (94,000) 40.5 (138,000) 50.8 (173,470) 77.2 (264,000) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 17.1 (58,330) 26.4 (90,000) 38.7 (132,000) 48.2 (164,635) 75.1 (256,000) Sensible - kW (BTU/hr) 17.1 (58,330) 26.4 (90,000) 38.7 (132,000) 48.2 (164,635) 71.0 (242,000) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 17.1 (58,330) 26.4 (90,000) 38.6 (132,000) 48.2 (164,635) 75.1 (256,000) Sensible - kW (BTU/hr) 17.1 (58,330) 26.4 (90,000) 38.6 (132,000) 48.2 (164,635) 71.0 (242,000) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 16.7 (57,095) 25.6 (87,000) 37.4 (128,000) 47.1 (160,740) 74.4 (253,840) Sensible - kW (BTU/hr) 16.7 (57,095) 25.6 (87,000) 37.4 (128,000) 47.1 (160,740) 74.4 (253,840) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 16.7 (57,095) 25.6 (87,000) 37.4 (128,000) 47.1 (160,740) 74.4 (253,840) Sensible - kW (BTU/hr) 16.7 (57,095) 25.6 (87,000) 37.4 (128,000) 47.1 (160,740) 74.4 (253,840) Condensing temperature for all above conditions: 52°C (125° F) Refrigerant type for all models: R-407C Refrigerant Charge per Circuit - kg (lbs) 2.8 (6.17) 3.9 (8.6) 4.4 (9.7) 3.9 (8.6) 4.6 (10.1) Compressor Information – COP** (ARI*** Conditions): 7.2°C (45°F) Evaporating, 54°C (130°F) Condensing Number of compressors 1 1 2 2 2 COP 3.0 3.0 3.0 3.0 3.1 Evaporator Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 5 Face Velocity - m/min (ft/min) 125 (410) 104 (342) 117 (383) 130 (428) 141 (461) * Nominal Rating Point ** Coefficient of Performance *** Air Conditioning and Refrigeration Institute InRoom Precision AC Tech Data Manual 25 Air Cooled (DX) Continued PA211 Cabinet Size 1 PA311 Cabinet Size 2 PA452 Cabinet Size 3 PA612 Cabinet Size 4 PA862 Cabinet Size 5 Fan Information Number of Fans 1 1 2 2 3 Air Flow - M³/hr (CFM) 7493 (4,410) 10007 (5,890) 14000 (8,240) 20116 (11,890) 24007 (14,130) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 75.40 79.30 77.40 83.20 81.50 Total Fan Power Consumption - kW (hp) 1.7 (2.3) 2.1 (2.8) 3.1 (4.2) 6.1 (8.2) 6.2 (8.3) Connection Sizes Number of DX Circuits 1 1 2 2 2 Liquid Line O.D. - mm (in) 12 (1/2) 16 (5/8) 16 (5/8) 16 (5/8) 16 (5/8) Discharge Line O.D. - mm (in) 16 (5/8) 22 (7/8) 22 (7/8) 22 (5/8) 22 (5/8) Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1) 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU/hr) - Includes Motor Heat 460 V 12.0 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) 230 V 9.0 (30736.8) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) Number of Stages 2 3 3 3 3 Downflow Filters - mm Quantities 1050 x 453 x 47 G4 2 2 1 1 1 1050 x 398 x 47 G4 N/A 1 3 4 5 Upflow Filters - mm Quantities 700 x 340 x 47 G4 1 1 N/A 1 1 700 x 332 x 47 G4 N/A 1 N/A N/A 1 700 x 502 x 47 G4 1 1 1 1 1 700 x 508 x 47 G4 N/A N/A 1 2 2 700 x 508 x 47 G4 N/A N/A 1 N/A N/A Physical Data Weight - kg (lb) 353 (778) 453 (999) 556 (1226) 680 (1499) 807 (1779) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) 2550 (100.39) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) 890 (35) 26 InRoom Precision AC Tech Data Manual MultiCool – Air Cooled (DX) with CW – 60Hz Operational Mode: Air Cooled (DX) Net Cooling Capacity PACW211 Cabinet Size 1 PACW311 Cabinet Size 2 PACW452 Cabinet Size 3 PACW612 Cabinet Size 4 PACW862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 19.2 (65,455) 29.7 (101,460) 43.7 (149,150) 54.5 (186,105) 83.9 (286,235) Sensible - kW (BTU/hr) 19.2 (65,455) 29.7 (101,460) 40.8 (139,365) 54.5 (186,105) 74.4 (253,840) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 17.8 (60,895) 27.6 (94,050) 40.0 (136,515) 50.3 (171,760) 77.8 (265,525) Sensible - kW (BTU/hr) * 17.8 (60,895) 27.6 (94,050) 40.0 (136,515) 50.3 (171,760) 71.8 (245,100) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 17.8 (60,895) 27.6 (94,050) 40.0 (136,515) 50.3 (171,760) 76.2 (260,015) Sensible - kW (BTU/hr) 17.8 (61,895) 27.6 (94,050) 40.0 (136,515) 50.2 (171,475) 76.2 (260,015) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 16.8 (57,380) 26.3 (89,775) 38.2 (130,340) 47.8 (163,020) 74.1 (252,890) Sensible - kW (BTU/hr) 16.8 (57,380) 26.3 (89,775) 38.2 (130,340) 47.8 (163,020) 70.0 (238,825) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 16.8 (57,380) 26.3 (89,775) 38.2 (130,340) 47.7 (163,020) 73.3 (250,230) Sensible - kW (BTU/hr) 16.8 (57,380) 26.3 (89,775) 38.2 (130,340) 47.7 (163,020) 73.3 (250,230) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 16.4 (56,050) 25.6 (87,485) 36.9 (126,065) 46.1 (157,225) 71.1 (242,820) Sensible - kW (BTU/hr) 16.4 (56,050) 25.6 (87,485) 36.9 (126,065) 46.1 (157,225) 71.1 (242,820) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 16.4 (56,050) 25.6 (87,485) 36.9 (126,065) 46.1 (157,225) 71.1 (242,820) Sensible - kW (BTU/hr) 16.4 (56,050) 25.6 (87,485) 36.9 (126,065) 46.1 (157,225) 71.1 (242,820) Condensing temperature for all above conditions: 52°C (125°F) Refrigerant type for all models: R-407C Refrigerant Charge per Circuit - kg (lbs) 2.8 (6.17) 3.9 (8.6) 4.4 (9.7) 3.9 (8.6) 4.6 (10.1) Compressor Information – COP** (ARI*** Conditions): 7.2°C (45°F) Evaporating, 54°C (130°F) Condensing Number of compressors 1 1 2 2 2 COP 3.0 3.0 3.0 3.0 3.1 Connection Sizes Liquid Line OD - mm (in) 12 (1/2) 16 (5/8) 16 (5/8) 16 (5/8) 16 (5/8) Discharge Line OD - mm (in) 16 (5/8) 22 (7/8) 22 (7/8) 22 (7/8) 22 (7/8) Evaporator Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 4 Face Velocity - m/min (ft/min) 125 (410) 104 (342) 117 (383) 124 (407) 141 (461) * Nominal Rating Point ** Coefficient of Performance *** Air Conditioning and Refrigeration Institute InRoom Precision AC Tech Data Manual 27 Operational Mode: Chilled Water (CW) Net Cooling Capacity - 7.2°C (45°F) EWT PACW211 Cabinet Size 1 PACW311 Cabinet Size 2 PACW452 Cabinet Size 3 PACW612 Cabinet Size 4 PACW862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 34.3 (117,040) 48.6 (165,965) 63.4 (216,505) 83.9 (286,520) 104.3 (355,965) Sensible - kW (BTU/hr) 25.9 (88,540) 36.6 (124,830) 47.9 (163,400) 63.3 (215935) 78.5 (268,090) Flow Rate - L/m (GPM) 98.4 (26.0) 138.2 (36.5) 182.1 (48.1) 244.5 (64.6) 302.5 (79.9) Total Pressure Drop Water Side - Kpa (ft) 88.8 (29.7) 58.0 (19.4) 79.5 (26.6) 76.5 (25.6) 58.6 (19.6) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 36.9 (125,780) 48.1 (164,065) 60.2 (205,485) Sensible - kW (BTU/hr) * 20.0 (68,115) 27.7 (94,620) 36.9 (125,780) 48.1 (164,065) 57.6 (196,460) Flow Rate - L/m (GPM) 59.4 (15.7) 81.4 (21.5) 109.4 (28.9) 146.9 (38.8) 182.8 (48.3) Total Pressure Drop Water Side Kpa (ft) 32.0 (10.7) 19.1 (6.4) 28.1 (9.4) 27.2 (9.1) 20.3 (6.8) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 36.9 (125,780) 48.1 (164,065) 61.7 (210,425) Sensible - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 36.9 (125,780) 48.1 (164,065) 61.7 (210,425) Flow Rate - L/m (GPM) 59.4 (15.7) 81.4 (21.5) 109.4 (28.9) 146.9 (38.8) 186.6 (49.3) Total Pressure Drop Water Side - Kpa (ft) 32.0 (10.7) 19.1 (6.4) 28.1 (9.4) 27.2 (9.1) 21.8 (7.3) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 29.3 (100,130) 37.4 (127,680) 48.6 (165,965) Sensible - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 29.3 (100,130) 37.4 (127,680) 48.5 (165,680) Flow Rate - L/m (GPM) 49.2 (13.0) 67.0 (17.7) 89.3 (23.6) 118.1 (31.1) 151.0 (39.9) Total Pressure Drop Water Side - Kpa (ft) 21.8 (7.3) 13.2 (4.4) 19.4 (6.5) 18.5 (6.2) 14.4 (4.7) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 14.7 (50,255) 22.4 (76,475) 29.3 (100,130) 37.4 (127,680) 48.5 (165,680) Sensible - kW (BTU/hr) 14.7 (50,255) 22.4 (76,475) 29.3 (100,130) 37.4 (127,680) 48.5 (165,680) Flow Rate - L/m (GPM) 49.2 (13.0) 67.0 (17.7) 89.3 (23.6) 118.1 (31.1) 151.0 (39.9) Total Pressure Drop Water Side - Kpa (ft) 21.8 (7.3) 13.2 (4.4) 19.4 (6.5) 18.5 (6.2) 14.4 (4.7) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 24.2 (82,650) 29.9 (102,125) 39.1 (133,570) Sensible - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 24.2 (82,650) 29.9 (102,125) 39.1 (133,570) Flow Rate - L/m (GPM) 42.4 (11.2) 57.2 (15.1) 75.3 (19.9) 97.7 (25.8) 125.3 (33.1) Total Pressure Drop Water Side - Kpa (ft) 16.1 (5.4) 9.6 (3.2) 14.1 (4.7) 12.3 (4.1) 10.5 (3.5) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 24.2 (82,650) 29.9 (102,125) 39.1 (133,570) Sensible - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 24.2 (82,650) 29.9 (102,125) 39.1 (133,570) Flow Rate - L/m (GPM) 42.4 (11.2) 57.2 (15.1) 75.3 (19.9) 97.7 (25.8) 125.3 (33.1) Total Pressure Drop Water Side - Kpa (ft) 16.1 (5.4) 9.6 (3.2) 14.1 (4.7) 12.3 (4.1) 10.5 (3.5) Valve Size - mm (in) 25 (1.0) 32 (1.25) 32 (1.25) 40 (1.5) 50 (2.0) Temperature medium in - °C (°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) Temperature medium in - °C (°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) Chilled Water Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 5 Face Velocity - m/min (ft/min) 161 (529) 142 (466) 160 (524) 173 (569) 179 (588) Connection Sizes Chilled Water In/Out. - mm (in) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) 54 (2 1/8) 54 (2 1/8) * Nominal Rating Point 28 InRoom Precision AC Tech Data Manual Information common to both modes PACW211 Cabinet Size 1 PACW311 Cabinet Size 2 PACW452 Cabinet Size 3 PACW612 Cabinet Size 4 PACW862 Cabinet Size 5 Connection Sizes Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Fan Information Number of Fans 1 1 2 2 3 Air Flow M³/hr (CFM) 7034 (4,140) 10007 (5,890) 14000 (8,240) 19386 (11,410) 24007 (14,130) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 76.6 79.7 78.6 83.4 82.7 Total Fan Power Consumption - kW (hp) 2.0 (2.7) 2.3 (3.1) 3.6 (4.8) 6.3 (8.4) 7.3 (9.8) Humidification - Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU/hr) - Includes Motor Heat 460 V 12.0 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) 230 V 9.0 (30736.8) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) Number of Stages 2 3 3 3 3 Downflow Filters - mm Quantities 1050 x 453 x 47 G4 2 2 1 1 1 1050 x 398 x 47 G4 N/A 1 3 4 5 Upflow Filters - mm Quantities 700 x 340 x 47 G4 1 1 N/A 1 1 700 x 332 x 47 G4 N/A 1 N/A N/A 1 700 x 502 x 47 G4 1 1 1 1 1 700 x 508 x 47 G4 N/A N/A 1 2 2 700 x 508 x 47 G4 N/A N/A 1 N/A N/A Physical Data Weight - kg (lb) 372 (820) 480 (1056) 600 (1322) 740 (1631) 884 (1949) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) 2550 (100.39) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) 890 (35) InRoom Precision AC Tech Data Manual 29 Fluid Cooled (Glycol 40%) – 60Hz Net Cooling Capacity PG211 Cabinet Size 1 PG311 Cabinet Size 2 PG452 Cabinet Size 3 PG612 Cabinet Size 4 PG862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 19.8 (67,450) 30.0 (102,410) 44.2 (150,785) 55.2 (188,290) 84.9 (289,750) Sensible - kW (BTU/hr) 19.8 (67,450) 30.0 (102,410) 41.3 (140,980) 55.2 (188,290) 75.4 (257,355) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 18.1 (61,940) 27.8 (95,000) 40.5 (138,130) 50.8 (173,470) 78.8 (269,040) Sensible - kW (BTU/hr) * 18.1 (61,940) 27.8 (95,000) 40.5 (138,130) 50.8 (173,470) 72.8 (248,615) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 18.1 (61,940) 27.8 (95,000) 40.5 (138,130) 50.8 (173,470) 77.2 (263,530) Sensible - kW (BTU/hr) 18.1 (61,940) 27.8 (95,000) 40.5 (138,130) 50.8 (173,470) 77.2 (263,530) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 17.1 (58,330) 26.6 (90,725) 38.7 (131,955) 48.2 (164,635) 75.1 (256,405) Sensible - kW (BTU/hr) 17.1 (58,330) 26.6 (90,725) 38.7 (131,955) 48.2 (164,635) 71.0 (242,440) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 17.1 (58,330) 26.4 (90,725) 38.7 (131,955) 48.2 (164,635) 74.4 (253,840) Sensible - kW (BTU/hr) 17.1 (58,330) 26.4 (90,725) 38.7 (131,955) 48.2 (164,635) 74.4 (253,840) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 16.7 (57,095) 25.9 (88,540) 37.4 (127,680) 47.1 (160,740) 72.2 (246,335) Sensible - kW (BTU/hr) 16.7 (57,095) 25.9 (88,540) 37.4 (127,680) 47.1 (160,740) 72.2 (246,335) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 16.7 (57,095) 25.9 (88,540) 37.4 (127,680) 47.4 (161,785) 72.2 (246,335) Sensible - kW (BTU/hr) 16.7 (57,095) 25.9 (88,540) 37.4 (127,680) 47.1 (160,740) 72.2 (246,335) Condensing temperature for all above conditions: 52°C (125°F) Refrigerant type for all models: R-407C Refrigerant Charge per Circuit - kg (lbs) 2.8 (6.17) 3.9 (8.6) 4.4 (9.7) 3.9 (8.6) 4.6 (10.1) Compressor Information – COP** (ARI*** Conditions): 7.2°C (45°F) Evaporating, 54°C (130°F) Condensing Number of compressors 1 1 2 2 2 COP 3.0 3.0 3.0 3.0 3.1 Evaporator Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 5 Face Velocity - m/min (ft/min) 125 (410) 104 (342) 117 (383) 130 (428) 141 (461) * Nominal Rating Point ** Coefficient of Performance *** Air Conditioning and Refrigeration Institute 30 InRoom Precision AC Tech Data Manual Fluid Cooled (Glycol 40%) Continued PG211 Cabinet Size 1 PG311 Cabinet Size 2 PG452 Cabinet Size 3 PG612 Cabinet Size 4 PG862 Cabinet Size 5 Fan Information Number of Fans 1 1 2 2 3 Air Flow - M³/hr (CFM) 7493 (4,410) 10007 (5,890) 14000 (8,240) 20116 (11,890) 24007 (14,130) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 75.4 79.2 77.4 83.2 83.2 Total Fan Power Consumption - kW (hp) 1.7 (2.3) 2.0 (2.7) 3.1 (4.2) 6.1 (8.2) 6.2 (8.3) Condenser Data Total Heat Rejection (THR) - kW (BTU/hr) 27.4 (93,400) 41.3 (141,100) 61.0 (208,200) 79.2 (270,400) 118.8 (405,600) Flow rate - L/m (GPM) 61.7 (16.3) 53.4 (14.1) 133.2 (35.2) 176.8 (46.7) 265.0 (70.0) Total pressure drop water side - kPa (ft) 87.3 (29.2) 34.1 (11.4) 84.9 (28.4) 106.4 (35.6) 141.7 (47.4) Valve size - mm (in) 20 (0.75) 25 (1.0) 32 (1.25) 32 (1.25) 40 (1.5) Connection Sizes Condenser In/Out - mm (in) 28 (1 1/8) 35 (1 3/8) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU) - Includes Motor Heat 460 V 12.0 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) 230 V 9.0 (30736.8) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) Number of Stages 2 3 3 3 3 Downflow Filters - mm Quantities 700 x 508 x 47 G4 1 N/A N/A N/A N/A 1050 x 453 x 47 G4 N/A 2 1 1 1 1050 x 398 x 47 G4 N/A 1 3 4 5 Upflow Filters - mm Quantities 700 x 340 x 47 G4 N/A 1 N/A 1 1 700 x 332 x 47 G4 N/A 1 N/A N/A 1 700 x 502 x 47 G4 N/A 1 1 1 1 700 x 508 x 47 G4 N/A N/A 1 1 2 700 x 516 x 47 G4 1 N/A 1 N/A N/A Physical Data Weight - kg (lb) 356 (785) 460 (1014) 564 (1243) 693 (1528) 825 (1819) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) 2550 (100.39) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) 890 (35) InRoom Precision AC Tech Data Manual 31 Fluid Cooled (Glycol 0%) – 60Hz Net Cooling Capacity PG211 Cabinet Size 1 PG311 Cabinet Size 2 PG452 Cabinet Size 3 PG612 Cabinet Size 4 PG862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 19.8 (67,450) 30.0 (102,410) 44.2 (151,765) 55.2 (188,290) 84.9 (290,750) Sensible - kW (BTU/hr) 19.8 (67,450) 30.0 (102,410) 41.3 (140,098) 55.2 (188,290) 75.4 (257,355) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 18.1 (61,940) 27.8 (95,000) 40.5 (138,130) 50.8 (173,470) 78.8 (269,040) Sensible - kW (BTU/hr) * 18.1 (61,940) 27.8 (95,000) 40.5 (138,130) 50.8 (173,470) 72.8 (248,615) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 18.1 (61,940) 27.8 (95,000) 40.5 (138,130) 50.8 (174,000) 77.2 (264,000) Sensible - kW (BTU/hr) 18.1 (61,940) 27.8 (95,000) 40.5 (138,130) 50.8 (174,000) 77.2 (264,000) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 17.1 (58,330) 26.6 (90,725) 38.7 (131,955) 48.2 (164,635) 75.1 (256,405) Sensible - kW (BTU/hr) 17.1 (58,330) 26.6 (90,725) 38.7 (131,955) 48.2 (164,635) 71.0 (242,440) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 17.1 (58,330) 26.6 (90,725) 38.7 (131,955) 48.2 (164,635) 74.4 (253,840) Sensible - kW (BTU/hr) 17.1 (58,330) 26.6 (90,725) 38.7 (131,955) 48.2 (164,635) 74.4 (253,840) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 16.7 (57,095) 25.9 (88,540) 37.4 (127,680) 47.1 (160,740) 72.2 (246,335) Sensible - kW (BTU/hr) 16.7 (57,095) 25.9 (88,540) 37.4 (127,680) 47.1 (160,740) 72.2 (246,335) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 16.7 (57,095) 25.9 (88,540) 37.4 (127,680) 47.4 (161,785) 72.2 (246,335) Sensible - kW (BTU/hr) 16.7 (57,095) 25.9 (88,540) 37.4 (127,680) 47.1 (160,740) 72.2 (246,335) Condensing temperature for all above conditions: 52°C (125° F) Refrigerant type for all models: R-407C Refrigerant Charge per Circuit - kg (lbs) 2.8 (6.17) 3.9 (8.6) 4.4 (9.7) 3.9 (8.6) 4.6 (10.1) Compressor Information – COP** (ARI*** Conditions): 7.2°C (45°F) Evaporating, 54°C (130°F) Condensing Number of compressors 1 1 2 2 2 COP 3.0 3.0 3.0 3.0 3.1 Evaporator Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 5 Face Velocity - m/min (ft/min) 125 (410) 104 (342) 117 (383) 130 (425) 141 (461) * Nominal Rating Point ** Coefficient of Performance *** Air Conditioning and Refrigeration Institute 32 InRoom Precision AC Tech Data Manual Fluid Cooled (Glycol 0%) Continued PG211 Cabinet Size 1 PG311 Cabinet Size 2 PG452 Cabinet Size 3 PG612 Cabinet Size 4 PG862 Cabinet Size 5 Fan Information Number of Fans 1 1 2 2 3 Air Flow - M³/hr (CFM) 7493 (4,410) 10007 (5,890) 14000 (8,240) 20116 (11,890) 24007 (14,130) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 75.40 79.20 77.20 83.20 83.20 Total Fan Power Consumption - kW (hp) 1.7 (2.3) 2.0 (2.7) 3.1 (4.2) 6.1 (8.2) 6.2 (8.3) Condenser Data Total Heat Rejection (THR) - kW (BTU/hr) 27.4 (93,400) 41.3 (141,100) 77.4 (264,200) 79.2 (270,400) 118.8 (405,600) Flow rate - L/m (GPM) 50.0 (13.2) 75.0 (19.8) 99.9 (26.4) 145.0 (38.3) 196.8 (52.0) Total pressure drop water side - kPa (ft) 54.7 (18.3) 59.8 (20.0) 52.3 (17.5) 68.8 (23.0) 76.8 (25.7) Valve size - mm (in) 20 (0.75) 25 (1.0) 20 (0.75) 25 (1.0) 25 (1.0) Connection Sizes Condenser In/Out - mm (in) 28 (1 1/8) 35 (1 3/8) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 20 (3/4) 20 (3/4) 20 (3/4) 20 (3/4) 20 (3/4) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU/hr) - Includes Motor Heat 460 V 12.0 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) 230 V 9.0 (30736.8) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) Number of Stages 2 3 3 3 3 Downflow Filters - mm Quantities 700 x 508 x 47 G4 1 N/A N/A N/A N/A 1050 x 453 x 47 G4 N/A 2 1 1 1 1050 x 398 x 47 G4 N/A 1 3 4 5 Upflow Filters - mm Quantities 700 x 340 x 47 G4 N/A 1 N/A 1 1 700 x 332 x 47 G4 N/A 1 N/A N/A 1 700 x 502 x 47 G4 N/A 1 1 1 1 700 x 508 x 47 G4 N/A N/A 1 1 2 700 x 516 x 47 G4 1 N/A 1 N/A N/A Physical Data Weight - kg (lb) 356 (785) 460 (1014) 564 (1243) 693 (1528) 825 (1819) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) 2550 (100.39) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) 890 (35) InRoom Precision AC Tech Data Manual 33 Fluid Cooled (Glycol 0%) with CW – 60Hz Operational Mode: Fluid Cooled (Glycol 0%) Net Cooling Capacity PGCW211 Cabinet Size 1 PGCW311 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 19.5 (66,405) 29.7 (101,460) 43.7 (149,150) 54.3 (185,440) 83.9 (286,235) Sensible - kW (BTU/hr) 19.5 (66,405) 29.7 (101,460) 40.8 (139,365) 54.3 (185,440) 74.4 (253,840) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 17.8 (60,895) 27.6 (94,050) 40.0 (136,515) 50.2 (171,190) 77.8 (265,525) Sensible - kW (BTU/hr) * 17.8 (60,895) 27.6 (94,050) 40.0 (136,515) 50.2 (171,190) 71.8 (245,100) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 17.8 (60,895) 27.6 (94,050) 40.0 (136,515) 50.2 (171,190) 76.2 (260,015) Sensible - kW (BTU/hr) 17.8 (60,895) 27.6 (94,050) 40.0 (136,515) 50.2 (171,190) 776.2 (260,015) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 16.8 (57,380) 26.3 (89,775) 38.2 (130,340) 47.6 (162,450) 74.1 (252,890) Sensible - kW (BTU/hr) 16.8 (57,380) 26.3 (89,775)) 38.2 (130,340) 47.6 (162,450) 70.0 (238,925) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 16.8 (57,380) 26.3 (89,775) 38.2 (130,340) 47.6 (162,450) 73.3 (250,230) Sensible - kW (BTU/hr) 16.8 (57,380) 26.3 (89,775)) 38.2 (130,340) 47.6 (162,450) 73.3 (250,230) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 16.4 (56,050) 25.6 (87,495) 36.9 (126,065) 46.5 (158,840) 71.1 (242,820) Sensible - kW (BTU/hr) 16.4 (56,050) 25.6 (87,495) 36.9 (126,065) 46.5 (158,840) 71.1 (242,820) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 16.4 (56,050) 25.6 (87,495) 36.9 (126,065) 46.5 (158,840) 71.1 (242,820) Sensible - kW (BTU/hr) 16.4 (56,050) 25.6 (87,495) 36.9 (126,065) 46.5 (158,840) 71.1 (242,820) Condensing temperature for all above conditions: 52°C (125°F) Refrigerant type for all models: R-407C Refrigerant Charge per Circuit - kg (lbs) 2.8 (6.17) 3.9 (8.6) 4.4 (9.7) 3.9 (8.6) 4.6 (10.1) Compressor Information – COP** (ARI*** Conditions): 7.2°C (45°F) Evaporating, 54°C (130°F) Condensing Number of compressors 1 1 2 2 2 COP 3.0 3.0 3.0 3.0 3.1 Evaporator Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 5 Face Velocity - m/min (ft/min) 125 (410) 104 (342) 117 (383) 124 (408) 141 (461) Condenser Data THR - kW (BTU/hr) 27.4 (93,400) 41.3 (141,100) 61.0 (208,200) 79.2 (270,400) 118.8 (405,600) Flow rate - L/m (GPM) 58.3 (15.4) 73.4 (19.4) 101.8 (26.9) 146.5 (38.7) 210.1 (55.5) Total pressure drop water side - kPa (ft) 73.9 (24.7) 57.4 (19.2) 70.3 (23.5) 70.3 (23.5) 86.1 (28.8) Valve size - mm (in) 20 (3/4) 25.4 (1.0) 32 (1.25) 32 (1.25) 40 (1.5) Temperature medium in - °C (°F) 40.5°C (105°F) 40.5°C (105°F) 40.5°C (105°F) 40.5°C (105°F) 40.5°C (105°F) Temperature medium in - °C (°F) 46.1°C (115°F) 46.1°C (115°F) 46.1°C (115°F) 46.1°C (115°F) 46.1°C (115°F) Connection Sizes In/Out - mm (in) 28 (1 1/8) 35 (1 3/8) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) * Nominal Rating Point ** Coefficient of Performance *** Air Conditioning and Refrigeration Institute 34 InRoom Precision AC Tech Data Manual Operational Mode: Chilled Water (CW) Net Cooling Capacity -7.2°C (45°F) EWT PGCW211 Cabinet Size 1 PGCW311 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 34.3 (117,040) 48.6 (165,965) 61.5 (210,045) 83.6 (285,285) 104.6 (356,915) Sensible - kW (BTU/hr) 25.9 (88,540) 36.6 (123,830) 47.0 (160,455) 63.1 (215,270) 78.6 (268,375) Flow Rate - L/m (GPM) 98.4 (26.0) 138.2 (36.5) 166.9 (44.1) 243.4 (64.3) 297.5 (78.6) Total pressure drop water side - kPa (ft) 88.8 (29.7) 58.0 (19.4) 68.2 (22.8) 76.2 (25.5) 57.1 (19.1) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 34.8 (118,940) 47.9 (163,400) 60.2 (205,485) Sensible - kW (BTU/hr) * 20.0 (68,115) 27.7 (94,620) 34.8 (118,940) 47.9 (163,400) 57.6 (196,460) Flow Rate - L/m (GPM) 59.4 (15.7) 81.4 (21.5) 98.0 (25.9) 146.1 (38.6) 182.8 (48.3) Total pressure drop water side - kPa (ft) 32.0 (10.7) 19.1 (6.4) 22.4 (7.5) 26.9 (9.0) 20.3 (6.8) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 34.8 (118,940) 47.9 (163,400) 61.7 (210,425) Sensible - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 34.8 (118,940) 47.9 (163,400) 61.7 (210,425) Flow Rate - L/m (GPM) 59.4 (15.7) 81.4 (21.5) 98.0 (25.9) 146.1 (38.6) 186.6 (49.3) Total pressure drop water side - kPa (ft) 32.0 (10.7) 19.1 (6.4) 22.4 (7.5) 26.9 (9.0) 21.8 (7.3) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 27.3 (93,005) 37.2 (127,110) 48.6 (165,965) Sensible - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 27.3 (93,005) 37.2 (127,110) 48.6 (165,965) Flow Rate - L/m (GPM) 49.2 (13.0) 67.0 (17.7) 78.7 (20.8) 117.3 (31.0) 151.0 (39.9) Total pressure drop water side - kPa (ft) 21.8 (7.3) 13.2 (4.4) 14.7 (4.9) 18.2 (6.1) 14.1 (4.7) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 27.3 (93,005) 37.2 (127,110) 48.6 (165,965) Sensible - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 27.3 (93,005) 37.2 (127,110) 48.6 (165,965) Flow Rate - L/m (GPM) 49.2 (13.0) 67.0 (17.7) 78.7 (20.8) 117.3 (31.0) 151.0 (39.9) Total pressure drop water side - kPa (ft) 21.8 (7.3) 13.2 (4.4) 14.7 (4.9) 18.2 (6.1) 14.1 (4.7) 21.1°C DB, 14.0°C WB(70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 22.2 (75,810) 29.8 (101,745) 39.1 (133,570) Sensible - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 22.2 (75,810) 29.8 (101,745) 39.2 (134,570) Flow Rate - L/m (GPM) 42.4 (11.2) 57.2 (15.1) 65.9 (17.4) 97.3 (25.7) 125.3 (33.1) Total pressure drop water side - kPa (ft) 16.1 (5.4) 9.6 (3.2) 11.1 (3.7) 12.3 (4.1) 10.5 (3.5) 21.1°C DB, 14.0°C WB(70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 22.2 (75,810) 29.8 (101,745) 39.1 (133,570) Sensible - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 22.2 (75,810) 29.8 (101,745) 39.1 (133,570) Flow Rate - L/m (GPM) 42.4 (11.2) 57.2 (15.1) 65.9 (17.4) 97.3 (25.7) 2.1 (33.1) Total pressure drop water side - kPa (ft) 16.1 (5.4) 19.1 (6.4) 11.1 (3.7) 12.3 (4.1) 125.3 (3.5) CW Valve Size - mm (in) 25 (1.0) 32 (1.25) 32 (1.25) 40 (1.5) 50 (2.0) Temperature medium in - °C (°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) Temperature medium in - °C (°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) Chilled Water Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 4 Face Velocity - m/min (ft/min) 161 (529) 142 (466) 156 (512) 173 (568) 179 (588) Connection Sizes Chilled Water In/Out - mm (in) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) 54 (2 1/8) 54 (2 1/8) * Nominal Rating Point InRoom Precision AC Tech Data Manual 35 Information common to both modes PGCW211 Cabinet Size 1 PGCW311 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 Connection Sizes Condenser In/Out - mm (in) 28 (1 1/8) 35 (1 3/8) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Fan Information Number of Fans 1 1 2 2 3 Air Flow - M³/hr (CFM) 125 (4,410) 167 (5,890) 233 (8,240) 323 (11,390) 400 (14,130) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 72.5 77.0 75.8 81.4 80.2 Total Fan Power Consumption - kW (hp) 2.0 (2.7) 2.3 (3.1) 3.6 (4.8) 6.2 (8.3) 7.3 (9.8) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU/hr) - Includes Motor Heat 460 V 12.0 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) 230 V 9.0 (30736.8) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) Number of Stages 2 3 3 3 3 Downflow Filters - mm Quantities 700 x 508 x 47 G4 1 N/A N/A N/A N/A 1050 x 453 x 47 G4 N/A 2 1 1 1 1050 x 398 x 47 G4 N/A 1 3 4 5 Upflow Filters - mm Quantities 700 x 340 x 47 G4 N/A 1 N/A 1 1 700 x 332 x 47 G4 N/A 1 N/A N/A 1 700 x 502 x 47 G4 N/A 1 1 1 1 700 x 508 x 47 G4 N/A N/A 1 1 2 700 x 516 x 47 G4 1 N/A 1 N/A N/A Physical Data Weight - kg (lb) 377 (831) 490 (1080) 608 (1340) 751 (1656) 900 (1984) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) 2550 (100.39) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) 890 (35) 36 InRoom Precision AC Tech Data Manual Fluid Cooled (Glycol 40%) with CW – 60Hz Operational Mode: Fluid Cooled (Glycol 40%) Net Cooling Capacity PGCW211 Cabinet Size 1 PGCW311 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 19.4 (66,120) 29.7 (101,460) 43.7 (149,150) 54.3 (185,440) 83.9 (286,235) Sensible - kW (BTU/hr) 19.4 (66,120) 29.7 (101,460) 40.8 (139,365) 54.3 (185,440) 74.4 (253,840) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 17.8 (60,895) 27.6 (94,050) 40.0 (136,515) 50.2 (171,190) 77.8 (265,525) Sensible - kW (BTU/hr) * 17.8 (60,895) 27.6 (94,050) 40.0 (136,515) 50.2 (171,190) 71.8 (245,100) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 17.8 (60,895) 27.6 (94,050) 40.0 (136,515) 50.2 (171,190) 76.2 (260,015) Sensible - kW (BTU/hr) 17.8 (60,895) 27.6 (94,050) 40.0 (136,515) 50.2 (171,190) 776.2 (260,015) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 16.8 (57,380) 26.3 (89,775) 38.2 (130,340) 47.6 (162,450) 74.1 (252,890) Sensible - kW (BTU/hr) 16.8 (57,380) 26.3 (89,775)) 38.2 (130,340) 47.6 (162,450) 70.0 (238,925) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 16.8 (57,380) 26.3 (89,775) 38.2 (130,340) 47.6 (162,450) 73.3 (250,230) Sensible - kW (BTU/hr) 16.8 (57,380) 26.3 (89,775)) 38.2 (130,340) 47.6 (162,450) 73.3 (250,230) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 16.4 (56,050) 25.6 (87,495) 36.9 (126,065) 46.5 (158,840) 71.1 (242,820) Sensible - kW (BTU/hr) 16.4 (56,050) 25.6 (87,495) 36.9 (126,065) 46.5 (158,840) 71.1 (242,820) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 16.4 (56,050) 25.6 (87,495) 36.9 (126,065) 46.5 (158,840) 71.1 (242,820) Sensible - kW (BTU/hr) 16.4 (56,050) 25.6 (87,495) 36.9 (126,065) 46.5 (158,840) 71.1 (242,820) Condensing temperature for all above conditions: 52°C (125°F) Refrigerant type for all models: R-407C Refrigerant Charge per Circuit - kg (lbs) 2.8 (6.17) 3.9 (8.6) 4.4 (9.7) 3.9 (8.6) 4.6 (10.1) Compressor Information – COP** (ARI*** Conditions): 7.2°C (45°F) Evaporating, 54°C (130°F) Condensing Number of compressors 1 1 2 2 2 COP 3.0 3.0 3.0 3.0 3.1 Evaporator Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 5 Face Velocity - m/min (ft/min) 125 (410) 104 (342) 117 (383) 124 (408) 141 (461) Condenser Data THR - kW (BTU/hr) 27.4 (93,400) 41.3 (141,100) 61.0 (208,200) 79.2 (270,400) 118.8 (405,600) Flow rate - L/m (GPM) 58.3 (15.4) 73.4 (19.4) 101.8 (26.9) 146.5 (38.7) 210.1 (55.5) Total pressure drop water side - kPa (ft) 73.9 (24.7) 57.4 (19.2) 70.3 (23.5) 70.3 (23.5) 86.1 (28.8) Valve size - mm (in) 20 (3/4) 25.4 (1.0) 32 (1.25) 32 (1.25) 40 (1.5) Temperature medium in - °C (°F) 40.5°C (105°F) 40.5°C (105°F) 40.5°C (105°F) 40.5°C (105°F) 40.5°C (105°F) Temperature medium in - °C (°F) 46.1°C (115°F) 46.1°C (115°F) 46.1°C (115°F) 46.1°C (115°F) 46.1°C (115°F) Connection Sizes In/Out - mm (in) 28 (1 1/8) 35 (1 3/8) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) * Nominal Rating Point ** Coefficient of Performance *** Air Conditioning and Refrigeration Institute InRoom Precision AC Tech Data Manual 37 Operational Mode: Chilled Water (CW) Net Cooling Capacity -7.2°C (45°F) EWT PGCW211 Cabinet Size 1 PGCW311 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 34.3 (117,040) 48.6 (165,965) 61.5 (210,045) 83.6 (285,285) 104.6 (356,915) Sensible - kW (BTU/hr) 25.9 (88,540) 36.6 (123,830) 47.0 (160,455) 63.1 (215,270) 78.6 (268,375) Flow Rate - L/m (GPM) 98.4 (26.0) 138.2 (36.5) 166.9 (44.1) 243.4 (64.3) 297.5 (78.6) Total pressure drop water side - kPa (ft) 88.8 (29.7) 58.0 (19.4) 68.2 (22.8) 76.2 (25.5) 57.1 (19.1) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 34.8 (118,940) 47.9 (163,400) 60.2 (205,485) Sensible - kW (BTU/hr) * 20.0 (68,115) 27.7 (94,620) 34.8 (118,940) 47.9 (163,400) 57.6 (196,460) Flow Rate - L/m (GPM) 59.4 (15.7) 81.4 (21.5) 98.0 (25.9) 146.1 (38.6) 182.8 (48.3) Total pressure drop water side - kPa (ft) 32.0 (10.7) 19.1 (6.4) 22.4 (7.5) 26.9 (9.0) 20.3 (6.8) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 34.8 (118,940) 47.9 (163,400) 61.7 (210,425) Sensible - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 34.8 (118,940) 47.9 (163,400) 61.7 (210,425) Flow Rate - L/m (GPM) 59.4 (15.7) 81.4 (21.5) 98.0 (25.9) 146.1 (38.6) 186.6 (49.3) Total pressure drop water side - kPa (ft) 32.0 (10.7) 19.1 (6.4) 22.4 (7.5) 26.9 (9.0) 21.8 (7.3) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 27.3 (93,005) 37.2 (127,110) 48.6 (165,965) Sensible - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 27.3 (93,005) 37.2 (127,110) 48.6 (165,965) Flow Rate - L/m (GPM) 49.2 (13.0) 67.0 (17.7) 78.7 (20.8) 117.3 (31.0) 151.0 (39.9) Total pressure drop water side - kPa (ft) 21.8 (7.3) 13.2 (4.4) 14.7 (4.9) 18.2 (6.1) 14.1 (4.7) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 27.3 (93,005) 37.2 (127,110) 48.6 (165,965) Sensible - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 27.3 (93,005) 37.2 (127,110) 48.6 (165,965) Flow Rate - L/m (GPM) 49.2 (13.0) 67.0 (17.7) 78.7 (20.8) 117.3 (31.0) 151.0 (39.9) Total pressure drop water side - kPa (ft) 21.8 (7.3) 13.2 (4.4) 14.7 (4.9) 18.2 (6.1) 14.1 (4.7) 21.1°C DB, 14.0°C WB(70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 22.2 (75,810) 29.8 (101,745) 39.1 (133,570) Sensible - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 22.2 (75,810) 29.8 (101,745) 39.2 (134,570) Flow Rate - L/m (GPM) 42.4 (11.2) 57.2 (15.1) 65.9 (17.4) 97.3 (25.7) 125.3 (33.1) Total pressure drop water side - kPa (ft) 16.1 (5.4) 9.6 (3.2) 11.1 (3.7) 12.3 (4.1) 10.5 (3.5) 21.1°C DB, 14.0°C WB(70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 22.2 (75,810) 29.8 (101,745) 39.1 (133,570) Sensible - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 22.2 (75,810) 29.8 (101,745) 39.1 (133,570) Flow Rate - L/m (GPM) 42.4 (11.2) 57.2 (15.1) 65.9 (17.4) 97.3 (25.7) 2.1 (33.1) Total pressure drop water side - kPa (ft) 16.1 (5.4) 19.1 (6.4) 11.1 (3.7) 12.3 (4.1) 125.3 (3.5) CW Valve Size - mm (in) 25 (1.0) 32 (1.25) 32 (1.25) 40 (1.5) 50 (2.0) Temperature medium in - °C (°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) Temperature medium in - °C (°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) Chilled Water Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 4 Face Velocity - m/min (ft/min) 161 (529) 142 (466) 156 (512) 173 (568) 179 (588) Connection Sizes Chilled Water In/Out - mm (in) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) 54 (2 1/8) 54 (2 1/8) * Nominal Rating Point 38 InRoom Precision AC Tech Data Manual Information common to both modes PGCW211 Cabinet Size 1 PGCW311 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 Connection Sizes Condenser In/Out - mm (in) 28 (1 1/8) 35 (1 3/8) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Fan Information Number of Fans 1 1 2 2 3 Air Flow - M³/hr (CFM) 125 (4,410) 167 (5,890) 233 (8,240) 323 (11,390) 400 (14,130) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 72.5 77.0 75.8 81.4 80.2 Total Fan Power Consumption - kW (hp) 2.0 (2.7) 2.3 (3.1) 3.6 (4.8) 6.2 (8.3) 7.3 (9.8) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU/hr) - Includes Motor Heat 460 V 12.0 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) 230 V 9.0 (30736.8) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) Number of Stages 2 3 3 3 3 Downflow Filters - mm Quantities 700 x 508 x 47 G4 1 N/A N/A N/A N/A 1050 x 453 x 47 G4 N/A 2 1 1 1 1050 x 398 x 47 G4 N/A 1 3 4 5 Upflow Filters - mm Quantities 700 x 340 x 47 G4 N/A 1 N/A 1 1 700 x 332 x 47 G4 N/A 1 N/A N/A 1 700 x 502 x 47 G4 N/A 1 1 1 1 700 x 508 x 47 G4 N/A N/A 1 1 2 700 x 516 x 47 G4 1 N/A 1 N/A N/A Physical Data Weight - kg (lb) 377 (831) 490 (1080) 608 (1340) 751 (1656) 900 (1984) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) 2550 (100.39) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) 890 (35) InRoom Precision AC Tech Data Manual 39 Fluid Cooled (Glycol 40%) with Economizer - 60Hz Operational Mode: Fluid Cooled (Glycol 40%) - Summer Net Cooling Capacity PGE211 Cabinet Size 2 PGE311 Cabinet Size 3 PGE452 Cabinet Size 4 PGE612 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 20.0 (68,115 31.1 (106,305) 45.6 (155,610) 58.6 (196,745) Sensible - kW (BTU/hr) 20.0 (68,115) 31.1 (106,305) 43.1 (147,000) 58.6 (196,745) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 19.2 (65,455) 28.9 (98,515) 41.5 (141,645) 54.1 (184,775) Sensible - kW (BTU/hr) * 19.2 (65,455) 28.9 (98,515) 41.5 (141,645) 54.1 (184,775) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 19.2 (65,455) 28.9 (98,515) 41.5 (141,645) 54.1 (184,775) Sensible - kW (BTU/hr) 19.2 (65,455) 28.9 (98,515) 41.5 (141,645) 54.1 (184,775) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 18.2 (62, 225) 27.4 (93,670) 40.0 (136,515) 51.9 (177,270) Sensible - kW (BTU/hr) 18.2 (62, 225) 27.4 (93,670) 40.0 (136,515) 51.9 (177,270) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 18.2 (62, 225) 27.4 (93,670) 40.0 (136,515) 51.9 (177,270) Sensible - kW (BTU/hr) 18.2 (62, 225) 27.4 (93,670) 40.0 (136,515) 51.9 (177,270) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 17.6 (59,945) 26.9 (91,770) 38.7 (132,240) 50.0 (170,810) Sensible - kW (BTU/hr) 17.6 (59,945) 26.9 (91,770) 38.7 (132,240) 50.0 (170,810) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 17.6 (59,945) 26.9 (91,770) 38.7 (132,240) 50.0 (170,810) Sensible - kW (BTU/hr) 17.6 (59,945) 26.9 (91,770) 38.7 (132,240) 50.0 (170,810) Condensing temperature for all above conditions: 52 °C (105°F) Glycol 40% temperature for all above conditions: Inlet temperature 40.5°C (105°F) - Outlet temperature 46.1°C (115°F) Refrigerant type for all models: R-407C Refrigerant Charge per Circuit - kg (lbs) 3.9 (8.6) 4.4 (9.7) 3.9 (8.6) 4.6 (10.1) Refrigeration Circuits 1 1 2 2 Compressor Information – COP** (ARI*** Conditions): 7.2°C (45°F) Evaporating, 54°C (130°F) Condensing Number of compressors 1 1 2 2 COP 3.0 3.0 3.0 3.0 Evaporator Coil Face Area - m² (ft²) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 5 Face Velocity - m/min (ft/min) 94 (309) 114 (375) 125 (411) 153 (502) Condenser Data THR - kW (BTU/hr) 27.4 (93,400) 41.8 (142,700) 61.8 (211,000) 81.0 (276,600) Flow rate - L/m (GPM) 60.2 (15.9) 86.7 (22.9) 135.1 (35.7) 176.8 (46.7) Total pressure drop water side - kPa (ft) 44.0 (14.7) 36.5 (12.2) 61.0 (20.4) 52.6 (17.6) 2-way Valve size 32 (1.25) 40 (1.5) 32 (1.25) 40 (1.5) Connection Sizes In/Out - mm (in) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) 54 (2 1/8) * Nominal Rating Point ** Coefficient of Performance *** Air Conditioning and Refrigeration Institute 40 InRoom Precision AC Tech Data Manual Operational Mode: Fluid Cooled (Glycol 40%) - Winter Net Cooling Capacity PGE211 Cabinet Size 2 PGE311 Cabinet Size 3 PGE452 Cabinet Size 4 PGE612 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 20.0 (68,115) 28.9 (98,515) 39.1 (133,570) 51.1 (174,420) Sensible - kW (BTU/hr) 20.0 (68,115) 28.9 (98,515) 38.3 (130,625) 51.1 (174,420) Flow rate - L/m (GPM) 60.2 (22.9) 86.7 (37.5) 135.1 (46.7) 176.8 (46.7) Total pressure drop water side - kPa (ft) 31.1 (10.4) 28.4 (9.5) 52.0 (17.4) 46.9 (15.7) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 17.6 (59,945) 24.4 (83,315) 33.2 (113,145) 44.5 (152,000) Sensible - kW (BTU/hr) * 17.6 (59,945) 24.4 (83,315) 3.2 (113,145) 44.5 (152,000) Flow rate - L/m (GPM) 60.2 (22.9) 86.7 (35.7) 135.1 (46.7) 176.8 (46.7) Total pressure drop water side - kPa (ft) 31.1 (10.4) 28.4 (9.5) 52.0 (17.4) 46.9 (15.7) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 17.6 (59,945) 24.4 (83,315) 33.2 (113,145) 44.5 (152,000) Sensible - kW (BTU/hr) 17.6 (59,945) 24.4 (83,315) 33.2 (113,145) 44.5 (152,000) Flow rate - L/m (GPM) 60.2 (22.9) 86.7 (37.5) 135.1 (46.7) 176.8 (46.7) Total pressure drop water side - kPa (ft) 31.1 (10.4) 28.4 (9.5) 52.0 (17.4) 46.9 (15.7) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 15.8 (53,770) 21.9 (74,575) 29.6 (101,175) 39.6 (135,185) Sensible - kW (BTU/hr) 15.8 (53,770) 21.9 (74,575) 29.6 (101,175) 39.6 (135,185) Flow rate - L/m (GPM) 60.2 (22.9) 86.7 (37.5) 135.1 (46.7) 176.8 (46.7) Total pressure drop water side - kPa (ft) 31.1 (10.4) 28.4 (9.5) 52.0 (17.4) 46.9 (15.7) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 15.8 (53,770) 21.9 (74,575) 29.6 (101,175) 39.6 (135,185) Sensible - kW (BTU/hr) 15.8 (53,770) 21.9 (74,575) 29.6 (101,175) 39.6 (135,185) Flow rate - L/m (GPM) 60.2 (22.9) 86.7 (37.5) 135.1 (46.7) 176.8 (46.7) Total pressure drop water side - kPa (ft) 31.1 (10.4) 28.4 (9.5) 52.0 (17.4) 46.9 (15.7) 21.1°C DB, 14.8°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 14.6 (49,875) 20.2 (69,065) 27.3 (93,005) 36.4 (135,185) Sensible - kW (BTU/hr) 14.6 (49,875) 20.2 (69,065) 27.3 (93,005) 36.4 (135,185) Flow rate - L/m (GPM) 60.2 (22.9) 86.7 (37.5) 135.1 (46.7) 176.8 (46.7) Total pressure drop water side - kPa (ft) 31.1 (10.4) 28.4 (9.5) 52.0 (17.4) 46.9 (15.7) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 14.6 (49,875) 20.2 (69,065) 27.3 (93,005) 36.4 (135,185) Sensible - kW (BTU/hr) 14.6 (49,875) 20.2 (69,065) 27.3 (93,005) 36.4 (135,185) Flow rate - L/m (GPM) 60.2 (22.9) 86.7 (37.5) 3.0 (47.6) 176.8 (46.7) Total pressure drop water side - kPa (ft) 31.1 (10.4) 28.4 (9.5) 62.8 (21.0) 46.9 (15.7) Condensing temperature for all above conditions: 52°C (125°F) Cooling Fluid (40% Glycol) Coil Face Area - m² (ft²) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 5 Face Velocity m/min (ft/min) 94 (309) 114 (375) 125 (411) 153 (502) Valve size 32 (1.25) 40 (1.5) 32 (1.25) 40 (1.5) Connection Sizes In/Out - mm (in) 35 (1 3/8) 42 (1 5/8) 42 (1 5/8) 55 (2 1/8) * Nominal Rating Point InRoom Precision AC Tech Data Manual 41 Information common to both modes PGE211 Cabinet Size 2 PGE311 Cabinet Size 3 PGE452 Cabinet Size 4 PGE612 Cabinet Size 5 Connection Sizes Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Fan Information Number of Fans 1 2 2 3 Air Flow - M³/hr (CFM) 6643 (3,910) 10007 (5,890) 14000 (8,240) 400 (14,130) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 71.2 71.9 76.7 79.5 Total Fan Power Consumption - kW (hp) 0.7 (0.9) 1.4 (1.9) 32.5 (3.4) 4.7 (6.3) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU/hr) - Includes Motor Heat 460 V 12.0 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 230 V 9.0 (30736.8) 18 (61473.6) 18 (61473.6) 27 (92210.4) Number of Stages 2 3 3 3 Downflow Filters - mm Quantities 1050 x 453 x 47 G4 2 1 1 1 1050 x 398 x 47 G4 1 3 4 5 Upflow Filters - mm Quantities 700 x 340 x 47 G4 1 N/A 1 1 700 x 332 x 47 G4 1 N/A N/A 1 700 x 502 x 47 G4 1 1 1 1 700 x 508 x 47 G4 N/A 1 1 2 700 x 516 x 47 G4 N/A 1 N/A N/A Physical Data Weight - kg (lb) 470 (1036) 584 (1287) 716 (1578) 893 (1969) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) 42 InRoom Precision AC Tech Data Manual 60Hz InRoom Electrical Specifications Air Cooled (DX) and Fluid Cooled (Glycol) Electrical Data With Reheat and Humidification Without Reheat and Humidification Compressor Data Model Size Airflow Pattern Cooling System Voltage (3ph/60Hz) MCA MOP Power (kW) MCA MOP Power (kW) LRA RLA 211 Up/ Down PAXXX PGXXX PACWXXX PGCWXXX 208-230 67.3 70 20.6 33.3 50 10.6 137 19.3 460-480 34.5 35 21.0 15.6 20 9.9 62 9.1 575-600 30.2 35 29.3 15.2 20 11.3 62 9.1 PGEXXX 208-230 84.3 90 25.7 33.3 50 10.6 137 19.3 460-480 43.8 50 26.6 15.6 20 9.9 62 9.1 575-600 37.7 40 39.3 15.2 20 11.3 62 9.1 311 Up/ Down PAXXX PGXXX PACWXXX PGCWXXX 208-230 100.3 125 30.4 49.3 80 15.3 195 32.1 460-480 53.0 60 32.0 24.7 40 15.3 95 16.4 575-600 42.2 45 32.3 19.9 30 14.3 95 16.4 PGEXXX 208-230 109.5 125 30.4 49.3 80 15.3 195 32.1 460-480 57.2 60 32.0 24.7 40 15.3 95 16.4 575-600 45.8 50 35.7 23.3 35 17.7 95 16.4 452 Up/ Down PAXXX PGXXX PACWXXX PGCWXXX 208-230 116.0 125 37.3 65.0 80 22.2 156 20.7 460-480 59.2 60 37.8 30.9 40 21.0 75 10.0 575-600 42.5 45 36 29.3 35 24.7 75 10.0 PGEXXX 208-230 141.6 150 44.9 65.0 80 22.2 156 20.7 460-480 73.4 80 46.2 30.9 40 21.0 75 10.0 575-600 53.7 60 43.5 29.3 35 24.7 75 10.0 612 Up/ Down PAXXX PGXXX PACWXXX PGCWXXX 208-230 167.3 175 53.3 90.6 100 30.6 195 32.1 460-480 87.8 90 55.7 45.3 60 30.5 95 16.4 575-600 57.1 60 44.7 35.3 45 27.1 95 16.4 PGEXXX 208-230 176.5 200 56.7 99.8 125 34.0 195 32.1 460-480 92.0 100 58.8 49.5 60 33.6 95 16.4 575-600 60.5 70 48.1 38.7 50 30.5 95 16.4 862 Up/ Down PAXXX PGXXX PACWXXX PGCWXXX 208-230 210.2 225 67.8 133.6 175 45.1 245 47.1 460-480 104.8 125 67.3 62.3 80 42.1 125 22.1 575-600 65.4 70 51.9 47.5 60 38.1 125 22.1 Note: Above data is based on maximum operating conditions Installation must comply with all local and/or national electrical codes. MCA - Minimum Circuit Ampacity MOP - Maximum Overcurrent Protection LRA - Compressor Locked Rotor Amps RLA - Compressor Rated Load Amps InRoom Precision AC Tech Data Manual 43 Chilled Water (CW) Electrical Data With Reheat and Humidification Without Reheat and Humidification Model Size Airflow Pattern Cooling System Voltage (3ph/60Hz) MCA MOP Power (kW) MCA MOP Power (kW) 400 Down PCWXXX 208-230 59.0 60 18.8 9.9 15 3.1 460-480 32.7 35 20.8 4.4 15 2.8 575-600 28.7 30 22.9 6.2 15 4.9 400 Up PCWXXX 208-230 60.6 70 19.3 11.5 20 3.7 460-480 33.5 35 21.4 5.3 15 3.3 575-600 28.7 30 22.9 6.2 15 4.9 660 Up/Down PCWXXX 208-230 91.6 100 29.2 19.8 25 6.3 460-480 46.5 50 29.6 8.9 15 5.7 575-600 39.7 40 31.7 9.7 15 7.7 900 Up/Down PCWXXX 208-230 109.4 125 34.9 23.0 25 7.3 460-480 56.4 60 35.9 10.5 15 6.7 575-600 47 50 37.6 10.4 15 8.3 1100 Up/Down PCWXXX 208-230 135.0 150 43.0 23.0 25 7.3 460-480 70.6 80 45.0 10.5 15 6.7 575-600 47 50 37.6 10.4 15 8.3 1500 Up/Down PCWXXX 208-230 146.5 150 46.7 34.5 35 11.0 460-480 75.9 80 48.4 15.8 20 10.0 575-600 62.5 70 50 14.7 20 11.7 Note: Above data is based on maximum operating conditions Installation must comply with all local and/or national electrical codes. MCA - Minimum Circuit Ampacity MOP - Maximum Overcurrent Protection LRA - Compressor Locked Rotor Amps RLA - Compressor Rated Load Amps 44 InRoom Precision AC Tech Data Manual 50Hz Performance Specifications Chilled Water (CW) - 50Hz Net Cooling Capacity PCW400 Cabinet Size 1 PCW660 Cabinet Size 2 PCW900 Cabinet Size 3 PCW1100 Cabinet Size 4 PCW1500 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 53.6(182,800) 86.1 (293,800) 120.1 (409,800) 1513.4 (523,400) 197.9 (675,300) Sensible - kW (BTU/hr) 35.8 (128,999) 58.4 (206,099) 82.7 (288,999) 102.4 (356,199) 134.3 (465,099) Flow Rate - L/m (GPM) 139.3 (36.8) 229.4 (60.6) 324.0 (85.6) 410.3 (108.4) 534.1 (141.1) Total Pressure Drop Water Side - Kpa (ft) 91.8 (30.7) 129.2 (43.2) 112.1 (37.5) 124.7 (41.7) 189.0 (63.2) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 27.4 (100,300) 54.5 (186,000) 65.5 (223,500) 82.5 (281,500) 104.8 (357,600) Sensible - kW (BTU/hr) * 25.5 (93,799) 45.5 (162,099) 59.1 (208,499) 73.9 (258,999) 95.3 (331,999) Flow Rate - L/sm(GPM) 80.0 (21.2) 147.6 (39.0) 182.8 (48.3) 3227.1 (60.0) 293.4 (77.5) Total Pressure Drop Water Side - Kpa (ft) 29.6 (9.9) 62.8 (21.0) 38.9 (13.0) 43.4 (14.5) 59.8 (20.0) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 29.9 (102,000) 49.8 (169,900) 66.3 (226,200) 82.2 (280,500) 105.8 (361,000) Sensible - kW (BTU/hr) 27.9 (101,999) 47.8 (169,0899) 64.3 (226,199) 80.2 (280,499) 103.8 (360,999) Flow Rate - L/m (GPM) 81.4 (21.5) 135.5 (35.8) 185.1 (48.9) 226.4 (59.8) 296.0 (78.2) Total Pressure Drop Water Side - Kpa (ft) 31.4 (10.5) 52.3 (17.5) 39.5 (13.2) 43.1 (14.4) 60.4 (20.2) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 25.0 (85,300) 42.0 (143,300) 54.8 (187,000) 68.2 (232,700) 86.3 (294,500) Sensible - kW (BTU/hr) 23.0 (85,299) 40.0 (13,299) 52.8 (186,999) 66.2 (232,699) 84.3 (294,499) Flow Rate - L/m (GPM) 68.9 (18.2) 115.1 (30.4) 155.2 (41.0) 190.0 (50.2) 245.7 (64.9) Total Pressure Drop Water Side - Kpa (ft) 22.4 (7.5) 39.8 (13.3) 28.4 (9.5) 31.1 (10.4) 42.5 (14.2) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 25.0 (85,300) 42.0 (143,300) 54.8 (187,000) 68.2 (232,700) 86.3 (294,500) Sensible - kW (BTU/hr) 23.0 (85,299) 40.0 (143,299) 52.8 (186,999) 66.2 (232,699) 84.3 (294,499) Flow Rate - L/m (GPM) 68.9 (18.2) 115.1 (30.4) 155.2 (41.0) 190.0 (50.2) 245.7 (64.9) Total Pressure Drop Water Side - Kpa (ft) 22.4 (7.5) 39.8 (13.3) 28.4 (9.5) 31.1 (10.4) 42.5 (14.2) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 21.7 (74,000) 36.6 (124,900) 47.0 (160,400) 58.5 (199,600) 72.9 (248,700) Sensible - kW (BTU/hr) 19.7 (73,999) 34.7 (124,899)) 45.0 (160,399) 56.5 (199,599) 70.9 (248,699) Flow Rate - L/m (GPM) 60.6 (16.0) 101.1 (26.7) 135.1 (35.7) 165.0 (43.6) 210.8 (55.7) Total Pressure Drop Water Side - Kpa (ft) 16.7 (5.6) 32.6 (10.9) 23.0 (7.7) 25.7 (8.6) 31.7 (10.6) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 21.7 (74,000) 36.6 (124,900) 47.0 (160,400) 58.5 (199,600) 72.9 (248,700) Sensible - kW (BTU/hr) 19.7 (73,999) 34.7 (124,899)) 45.0 (160,399) 56.5 (199,599) 70.9 (248,699) Flow Rate - L/m (GPM) 60.6 (16.0) 101.1 (26.7) 135.1 (35.7) 165.0 (43.6) 210.8 (55.7) Total Pressure Drop Water Side - Kpa (ft) 16.7 (5.6) 32.6 (10.9) 23.0 (7.7) 25.7 (8.6) 31.7 (10.6) Valve Size - mm (in) 32 (1.25) 40 (1.5) 50 (2.0) 50 (2.0) 50 (2.0) Temperature medium in - °C (°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) Temperature medium in - °C (°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) Chilled Water Coil Face Area - m² (ft²) 1.09 (11.77) 1.66 (17.82) 1.53 (16.52) 1.94 (20.86) 2.31 (24.88) Rows Deep 5 5 5 5 5 Face Velocity - m/min (ft/min) 130 (428) 132 (432) 112 (367) 102 (336) 114 (373) * Nominal Rating Point InRoom Precision AC Tech Data Manual 45 Chilled Water Continued PCW400 Cabinet Size 1 PCW660 Cabinet Size 2 PCW900 Cabinet Size 3 PCW1100 Cabinet Size 4 PCW1500 Cabinet Size 5 Fan Information Number of Fans 1 2 2 2 3 Air Flow - M³/hr (CFM) 8495 (5,000) 12997 (7,650) 18995 (11,180) 22002 (12,950) 29495 (17,360) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 72.1 75.2 79.1 85.7 86.7 Total Fan Power Consumption - kW (hp) 1.7 (2.3) 2.6 (3.5) 5.3 (7.1) 5.4 (7.2) 8.8 (11.8) Connection Sizes Upflow Chilled Water In/Out - mm (in) 35 (1 3/8) 42 (1 5/8) 54 (2 1/8) 70 (2 3/4) 70 (2 3/4) Downflow Chilled Water In/Out - mm (in) 35 (1 3/8) 42 (1 5/8 54 (2 1/8) 54 (2 1/8) 54 (2 1/8) Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU/hr) - Includes Motor Heat 400 V 12 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) Number of Stages 1 2 2 3 3 Downflow Filters - mm Quantities 836 x 546 x 92 G4 N/A N/A 3 3 3 836 x 393 x 92 G4 N/A 1 N/A 1 2 836 x 446 x 92 G4 2 2 N/A N/A N/A Upflow Filters - mm Quantities 795 x 508 x 92 G4 N/A N/A 1 2 2 795 x 341 x 92 G4 1 1 N/A 1 1 795 x 333 x 92 G4 N/A 1 N/A N/A 1 795 x 365 x 92 G4 N/A N/A 1 1 1 795 x 516 x 92 G4 N/A N/A 1 N/A N/A 795 x 502 x 92 G4 1 1 N/A N/A N/A Physical Data Weight - kg (lb) 307 (677) 362 (798) 547 (1206) 568 (1252) 755 (1664) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) 2550 (100.39) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) 890 (35) 46 InRoom Precision AC Tech Data Manual Air Cooled (DX) System - 50Hz Net Cooling Capacity PA211 Cabinet Size 1 PA311 Cabinet Size 2 PA452 Cabinet Size 3 PA612 Cabinet Size 4 PA862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 18.9 (64,505) 28.4 (96,900) 41.8 (142,595) 53.9 (184,110) 80.6 (275,215) Sensible - kW (BTU/hr) 18.9 (64,505) 28.4 (96,900) 41.8 (142,595) 53.9 (184,110) 73.9 (252,225) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 17.7 (60,325) 26.1 (89,110) 38.7 (132,240) 49.7 (169,575) 73.2 (249,945) Sensible - kW (BTU/hr) * 17.7 (60,325) 26.1 (89,110) 38.7 (132,240) 49.7 (169,575) 73.2 (249,945) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 17.7 (60,325) 26.1 (89,110) 38.7 (132,240) 49.7 (169,575) 73.4 (250,610) Sensible - kW (BTU/hr) 17.7 (60,325) 26.1 (89,110) 38.7 (132,240) 49.7 (169,575) 73.4 (250,610) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 16.9 (57,665) 25.1 (85,595) 36.9 (126,065) 47.7 (162,640) 70.2 (239,590) Sensible - kW (BTU/hr) 16.9 (57,665) 25.1 (85,595) 36.9 (126,065) 47.7 (162,640) 70.2 (239,590) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 16.9 (57,665) 25.1 (85,595) 36.9 (126,065) 47.7 (162,640) 70.2 (239,590) Sensible - kW (BTU/hr) 16.9 (57,665) 25.1 (85,595) 36.9 (126,065) 47.7 (162,640) 70.2 (239,590) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 16.9 (57,665) 24.2 (82,650) 35.7 (121,885) 45.9 (156,560) 68.0 (232,085) Sensible - kW (BTU/hr) 16.9 (57,665) 24.2 (82,650) 35.7 (121,885) 45.9 (156,560) 68.0 (232,085) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 16.9 (57,665) 24.2 (82,650) 35.7 (121,885) 45.9 (156,560) 68.0 (232,085) Sensible - kW (BTU/hr) 16.9 (57,665) 24.2 (82,650) 35.7 (121,885) 45.9 (156,560) 68.0 (232,085) Condensing temperature for all above conditions: 52°C (125°F) Refrigerant type for all models: 407C Refrigerant Charge per Circuit - kg (lbs) 2.8 (6.17) 3.9 (8.6) 4.4 (9.7) 3.9 (8.6) 4.6 (10.1) Compressor Information – COP** (ARI*** Conditions): 7.2°C (45°F) Evaporating, 54°C (130°F) Condensing Number of compressors 1 1 2 2 2 COP 3.1 3.1 3.0 3.1 3.0 Evaporator Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 5 Face Velocity - m/min (ft/min) 125 (410) 104 (342) 117 (383) 124 (407) 141 (461) * Nominal Rating Point ** Coefficient of Performance *** Air Conditioning and Refrigeration Institute InRoom Precision AC Tech Data Manual 47 Air Cooled Continued PA211 Cabinet Size 1 PA311 Cabinet Size 2 PA452 Cabinet Size 3 PA612 Cabinet Size 4 PA862 Cabinet Size 5 Fan Information Number of Fans 1 1 2 2 3 Air Flow - M³/hr (CFM) 7493 (4,410) 10007 (5,890) 14000 (8,240) 20116 (11,970) 24007 (14,130) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 75.40 79.30 77.40 83.20 81.50 Total Fan Power Consumption - kW (hp) 1.7 (2.3) 2.1 (2.8) 3.1 (4.2) 6.1 (8.2) 6.2 (8.3) Connection Sizes Number of DX Circuits 1 1 2 2 2 Air Liquid Line O.D. - mm (in) 12 (1/2) 16 (5/8) 16 (5/8) 16 (5/8) 16 (5/8) Air Discharge Line O.D. - mm (in) 16 (5/8) 22 (7/8) 22 (7/8) 22 (5/8) 22 (5/8) Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1) 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU/hr) - Includes Motor Heat 400 V 12 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) Number of Stages 2 3 3 3 3 Downflow Filters - mm Quantities 1050 x 453 x 47 G4 2 2 1 1 1 1050 x 398 x 47 G4 N/A 1 3 4 5 Upflow Filters - mm Quantities 700 x 340 x 47 G4 1 1 N/A 1 1 700 x 332 x 47 G4 N/A 1 N/A N/A 1 700 x 502 x 47 G4 1 1 1 1 1 700 x 508 x 47 G4 N/A N/A 1 2 2 700 x 508 x 47 G4 N/A N/A 1 N/A N/A Physical Data Weight - kg (lb) 353 (778) 453 (999) 556 (1226) 680 (1499) 807 (1779) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) 2550 (100.39) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) 890 (35) 48 InRoom Precision AC Tech Data Manual MultiCool - Air Cooled (DX) with CW - 50Hz Operational Mode: Air (DX) Net Cooling Capacity PACW211 Cabinet Size 1 PACW311 Cabinet Size 2 PACW452 Cabinet Size 3 PACW612 Cabinet Size 4 PACW862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 19.5 (66,405) 28.2 (95,235) 41.3 (140,980) 53.3 (181,830) 79.6 (271,605) Sensible - kW (BTU/hr) 19.5 (66,405) 28.2 (95,235) 41.3 (140,980) 53.3 (181,830) 72.8 (248,615) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 17.4 (59,280) 25.9 (88,540) 38.3 (130,625) 49.1 (167,580) 72.2 (246,335) Sensible - kW (BTU/hr) * 17.4 (59,280) 25.9 (88,540) 38.3 (130,625) 49.1 (167,580) 72.2 (246,335) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 17.4 (59,280) 25.9 (89,540) 38.3 (130,625) 49.1 (167,580) 72.4 (247,000) Sensible - kW (BTU/hr) 17.4 (59,280) 25.9 (89,540) 38.3 (130,625) 49.1 (167,580) 72.4 (247,000) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 16.6 (56,715) 24.9 (84,930) 36.5 (124,450) 46.6 (159,125) 69.1 (235,980) Sensible - kW (BTU/hr) 16.6 (56,715) 24.9 (84,930) 36.5 (124,450) 46.6 (159,125) 69.1 (235,980) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 16.6 (56,715) 24.9 (84,930) 36.5 (124,450) 46.6 (159,125) 69.1 (235,980) Sensible - kW (BTU/hr) 16.6 (56,715) 24.9 (84,930) 36.5 (124,450) 46.6 (159,125) 69.1 (235,980) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 16.1 (55,100) 24.0 (81,985) 35.2 (124,450) 45.5 (155,230) 67.0 (228,570) Sensible - kW (BTU/hr) 16.1 (55,100) 24.0 (81,985) 35.2 (124,450) 45.5 (155,230) 67.0 (228,570) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 16.1 (55,100) 24.0 (81,985) 35.2 (124,450) 45.5 (155,230) 67.0 (228,570) Sensible - kW (BTU/hr) 16.1 (55,100) 24.0 (81,985) 35.2 (124,450) 45.5 (155,230) 67.0 (228,570) Condensing temperature for above conditions: 48.8°C (120° F) Refrigerant type for all models: 407C Refrigerant Charge per Circuit - kg (lbs) 2.8 (6.17) 3.9 (8.6) 4.4 (9.7) 3.9 (8.6) 4.6 (10.1) Compressor Information – COP** (ARI*** Conditions): 7.2°C (45°F) Evaporating, 54°C (130°F) Condensing Number of compressors 1 1 2 2 2 COP 3.0 3.1 3.0 3.1 3.0 Connection Sizes Liquid Line OD - mm (in) 12 (1/2) 16 (5/8) 16 (5/8) 16 (5/8) 16 (5/8) Discharge Line OD - mm (in) 16 (5/8) 22 (7/8) 22 (7/8) 22 (7/8) 22 (7/8) Evaporator Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 4 Face Velocity - m/min (ft/min) 125 (410) 104 (342) 117 (383) 124 (407) 141 (461) * Nominal Rating Point ** Coefficient of Performance *** Air Conditioning and Refrigeration Institute InRoom Precision AC Tech Data Manual 49 Operational Mode: Chilled Water Net Cooling Capacity - 7.2°C (45°F) EWT PACW211 Cabinet Size 1 PACW311 Cabinet Size 2 PACW452 Cabinet Size 3 PACW612 Cabinet Size 4 PACW862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 34.3 (117,040) 48.6 (168,965) 63.4 (216,505) 83.9 (286,520) 104.3 (355,965) Sensible - kW (BTU/hr) 25.9 (88,540) 36.6 (124,830) 47.9 (163,400) 63.3 (215,935) 78.5 (268,090) Flow Rate - L/m (GPM) 98.4 (26.0) 138.2 (36.5) 182.1 (48.1) 244.5 (64.5) 302.5 (79.9) Total Pressure Drop Water Side - Kpa (ft) 88.8 (29.7) 58.0 (19.4) 79.5 (26.6) 76.5 (25.6) 58.6 (19.6) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 36.9 (125,780) 48.1 (164,065) 60.2 (205,485) Sensible - kW (BTU/hr) * 20.0 (68,115) 27.7 (94,620) 36.9 (125,780) 48.1 (164,065) 57.6 (196,460) Flow Rate - L/m (GPM) 59.4 (15.7) 81.4 (21.5) 109.4 (28.9) 146.9 (38.8) 182.8 (48.3) Total Pressure Drop Water Side - Kpa (ft) 32.0 (10.7) 19.1 (6.4) 28.1 (9.4) 27.2 (9.1) 20.3 (6.8) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 36.9 (125,780) 48.1 (164,065) 61.7 (210,425) Sensible - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 36.9 (125,780) 48.1 (164,065) 61.7 (210,425) Flow Rate - L/m (GPM) 59.4 (15.7) 81.4 (21.5) 109.4 (28.9) 146.9 (38.8) 186.6 (49.3) Total Pressure Drop Water Side - Kpa (ft) 32.0 (10.7) 19.1 (6.4) 28.1 (9.4) 26.9 (9.0) 21.8 (7.3) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 29.3 (100,130) 37.4 (127,680) 48.6 (165,965) Sensible - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 29.3 (100,130) 37.4 (127,680) 48.5 (165,680) Flow Rate - L/m (GPM) 49.2 (13.0) 67.0 (17.7) 89.3 (23.6) 118.1 (31.2) 151.0 (39.9) Total Pressure Drop Water Side - Kpa (ft) 21.8 (7.3) 13.2 (4.4) 19.4 (6.5) 18.5 (6.2) 14.1 (4.7) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 29.3 (100,130) 37.4 (127,680) 48.5 (165,680) Sensible - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 29.3 (100,130) 37.4 (127,680) 48.5 (165,680) Flow Rate - L/m (GPM) 49.2 (13.0) 67.0 (17.7) 89.3 (23.6) 118.1 (31.2) 151.0 (39.9) Total Pressure Drop Water Side - Kpa (ft) 21.8 (7.3) 13.2 (4.4) 19.4 (6.5) 18.5 (6.2) 14.4 (4.7) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 24.2 (82,650) 29.9 (102,125) 39.1 (133,570) Sensible - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 24.2 (82,650) 29.9 (102,125) 39.1 (133,570) Flow Rate - L/m (GPM) 42.4 (11.2) 57.2 (15.1) 75.3 (19.9) 97.7 (25.8) 125.3 (33.1) Total Pressure Drop Water Side - Kpa (ft) 16.1 (5.4) 9.6 (3.2) 14.1 (4.7) 12.3 (4.1) 10.5 (3.5) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 24.2 (82,650) 29.9 (102,125) 39.1 (133,570) Sensible - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 24.2 (82,650) 29.9 (102,125) 39.1 (133,570) Flow Rate - L/m (GPM) 42.4 (11.2) 57.2 (15.1) 75.3 (19.9) 97.7 (25.8) 125.3 (33.1) Total Pressure Drop Water Side - Kpa (ft) 16.1 (5.4) 9.6 (3.2) 14.1 (4.7) 12.3 (4.1) 10.5 (3.5) CW Valve Size - mm (in) 25 (1.0) 32 (1.3) 32 (1.3) 40 (1.5) 50 (2.0) Temperature medium in - °C (°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) Temperature medium in - °C (°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) Chilled Water Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 5 Face Velocity - m/min (ft/min) 161 (529) 142 (466) 160 (524) 173 (566) 179 (588) Connection Sizes In/Out. - mm (in) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) 54 (2 1/8) 54 (2 1/8) * Nominal Rating Point 50 InRoom Precision AC Tech Data Manual Information common to both modes PACW211 Cabinet Size 1 PACW311 Cabinet Size 2 PACW452 Cabinet Size 3 PACW612 Cabinet Size 4 PACW862 Cabinet Size 5 Connection Sizes Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Fan Information Number of Fans 1 1 2 2 3 Air Flow - M³/hr (CFM) 7034 (4,140) 10007 (5,890) 14000 (8,240) 19386 (11,390) 24007 (14,130) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 76.6 79.7 78.6 83.4 82.7 Total Fan Power Consumption - kW (hp) 2.0 (2.7) 2.3 (3.1) 3.6 (4.8) 6.3 (8.4) 7.3 (9.8) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1) 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU/hr) - Includes Motor Heat 400 V 12 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) Number of Stages 2 3 3 3 3 Downflow Filters - mm Quantities 1050 x 453 x 47 G4 2 2 1 1 1 1050 x 398 x 47 G4 N/A 1 3 4 5 Upflow Filters - mm Quantities 700 x 340 x 47 G4 1 1 N/A 1 1 700 x 332 x 47 G4 N/A 1 N/A N/A 1 700 x 502 x 47 G4 1 1 1 1 1 700 x 508 x 47 G4 N/A N/A 1 2 2 700 x 508 x 47 G4 N/A N/A 1 N/A N/A Physical Data Weight - kg (lb) 372 (820) 480 (1056) 600 (1322) 740 (1631) 884 (1949) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) 2550 (100.39) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) 890 (35) InRoom Precision AC Tech Data Manual 51 Fluid Cooling (Glycol 40%) – 50Hz Net Cooling Capacity - 40.5°C (105°F) EWT PG211 Cabinet Size 1 PG311 Cabinet Size 2 PG452 Cabinet Size 3 PG612 Cabinet Size 4 PG862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 18.9 (64,505) 28.5 (97,280) 41.8 (142,595) 53.9 (184,110) 80.6 (275,215) Sensible - kW (BTU/hr) 18.9 (64,505) 28.5 (97,280) 41.8 (142,595) 53.9 (184,110) 73.9 (252,225) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 17.7 (60,325) 26.2 (89,490) 38.7 (132,240) 49.7 (169,575) 73.2 (249,945) Sensible - kW (BTU/hr) * 17.7 (60,325) 26.2 (89,490) 38.7 (132,240) 49.7 (169,575) 73.2 (249,945) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 17.7 (60,325) 26.2 (89,490) 38.7 (132,240) 49.7 (169,575) 73.4 (250,610) Sensible - kW (BTU/hr) 17.7 (60,325) 26.2 (89,490) 38.7 (132,240) 49.7 (169,575) 73.4 (250,610) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 16.9 (57,665) 25.2 (85,880) 36.9 (126,065) 47.7 (162,735) 70.2 (239,590) Sensible - kW (BTU/hr) 16.9 (57,665) 25.2 (85,880) 36.9 (126,065) 47.7 (162,735) 70.2 (239,590) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 16.9 (57,665) 25.2 (85,880) 36.9 (126,065) 47.7 (162,735) 70.2 (239,590) Sensible - kW (BTU/hr) 16.9 (57,665) 25.2 (85,880) 36.9 (126,065) 47.7 (162,735) 70.2 (239,590) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 16.4 (56,050) 24.3 (83,030) 35.7 (121,885) 45.9 (156,560) 68.0 (232,085) Sensible - kW (BTU/hr) 16.4 (56,050) 24.3 (83,030) 35.7 (121,885) 45.9 (156,560) 68.0 (232,085) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 16.3 (55,765) 24.3 (83,030) 35.7 (121,885) 45.9 (156,560) 68.0 (232,085) Sensible - kW (BTU/hr) 16.4 (56,050) 24.3 (83,030) 35.7 (121,885) 45.9 (156,560) 68.0 (232,085) Condensing temperature for all above conditions: 52°C (125° F) Refrigerant type for all models: R-407C Refrigerant Charge per Circuit - kg (lbs) 2.8 (6.17) 3.9 (8.6) 4.4 (9.7) 3.9 (8.6) 4.6 (10.1) Compressor Information – COP** (ARI*** Conditions): 7.2°C (45°F) Evaporating, 54°C (130°F) Condensing Number of compressors 1 1 2 2 2 COP 3.0 3.0 3.0 3.0 3.1 Evaporator Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 5 Face Velocity - m/min (ft/min) 125 (410) 104 (342) 117 (383) 130 (425) 132 (432) * Nominal Rating Point ** Coefficient of Performance *** Air Conditioning and Refrigeration Institute 52 InRoom Precision AC Tech Data Manual Fluid Cooled (Glycol 40%) Continued PG211 Cabinet Size 1 PG311 Cabinet Size 2 PG452 Cabinet Size 3 PG612 Cabinet Size 4 PG862 Cabinet Size 5 Fan Information Number of Fans 1 1 2 2 3 Air Flow - M³/hr (CFM) 7493 (4,410) 10007 (5,890) 14000 (8,240) 20116 (11,840) 24007 (14,130) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 75.4 79.2 77.4 83.2 81.5 Total Fan Power Consumption - kW (hp) 1.7 (2.3) 2.0 (2.7) 3.1 (4.2) 6.1 (8.2) 6.2 (8.3) Condenser Data (40% Glycol inlet temperature 40.5°C (105°F), outlet temperature 46.1°C (115°F) Total Heat Rejection (THR) - kW (BTU/hr) 26.5 (90,300) 39.1 (133,100) 58.4 (199,400) 77.3 (263,800) 113.3 (386,600) Flow rate - L/m (GPM) 58.3 (15.4) 78.4 (20.7) 123.4 (32.6) 160.1 (42.3) 246.8 (65.2) Total pressure drop water side - kPa (ft) 78.6 (26.3) 70.3 (23.5) 73.6 (24.6) 88.5 (29.6) 124.1 (41.5) Valve size - mm (in) 20 (0.75) 25 (1.0) 32 (1.25) 32 (1.25) 40 (1.50) Connection Sizes Condenser In/Out - mm (in) 28 (1 1/8) 35 (1 3/8) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU/hr) Includes Motor Heat 400 V 12 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) Number of Stages 2 3 3 3 3 Downflow Filters - mm Quantities 700 x 508 x 47 G4 1 N/A N/A N/A N/A 1050 x 453 x 47 G4 N/A 2 1 1 1 1050 x 398 x 47 G4 N/A 1 3 4 5 Upflow Filters - mm Quantities 700 x 340 x 47 G4 N/A 1 N/A 1 1 700 x 332 x 47 G4 N/A 1 N/A N/A 1 700 x 502 x 47 G4 N/A 1 1 1 1 700 x 508 x 47 G4 N/A N/A 1 1 2 700 x 516 x 47 G4 1 N/A 1 N/A N/A Physical Data Weight - kg (lb) 356 (785) 460 (1014) 564 (1243) 693 (1528) 825 (1819) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) 2550 (100.39) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) 890 (35) InRoom Precision AC Tech Data Manual 53 Fluid Cooled (Glycol 0%) – 50Hz Net Cooling Capacity PG211 Cabinet Size 1 PG311 Cabinet Size 2 PG452 Cabinet Size 3 PG612 Cabinet Size 4 PG862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 18.9 (64,505) 28.5 (97,280) 41.8 (142,595) 53.9 (184,110) 80.6 (275,215) Sensible - kW (BTU/hr) 18.9 (64,505) 28.5 (97,280) 41.8 (142,595) 53.9 (184,110) 80.6 (275,215) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 17.7 (60,325) 26.2 (89,490) 38.7 (132,240) 49.7 (169,575) 73.2 (249,945) Sensible - kW (BTU/hr) * 17.7 (60,325) 26.2 (89,490) 38.7 (132,240) 49.7 (169,575) 73.2 (249,945) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 17.7 (60,325) 26.2 (89,490) 38.7 (132,240) 49.7 (169,575) 73.4 (250,610) Sensible - kW (BTU/hr) 17.7 (60,325) 26.2 (89,490) 38.7 (132,240) 49.7 (169,575) 73.4 (250,610) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 16.9 (57,665) 25.2 (85,880) 36.9 (126,065) 47.7 (162,735) 70.2 (239,590) Sensible - kW (BTU/hr) 16.9 (57,665) 25.2 (85,880) 36.9 (126,065) 47.7 (162,735) 70.2 (239,590) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 16.9 (57,665) 25.2 (85,880) 36.9 (126,065) 47.7 (162,735) 70.2 (239,590) Sensible - kW (BTU/hr) 16.9 (57,665) 25.2 (85,880) 36.9 (126,065) 47.7 (162,735) 70.2 (239,590) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 16.4 (56,050) 24.3 (83,030) 35.7 (121,885) 45.9 (156,560) 68.0 (232,085) Sensible - kW (BTU/hr) 16.4 (56,050) 24.3 (83,030) 35.7 (121,885) 45.9 (156,560) 68.0 (232,085) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 16.3 (55,765) 24.3 (83,030) 35.8 (121,885) 45.9 (156,560) 68.0 (232,085) Sensible - kW (BTU/hr) 16.4 (56,050) 24.3 (83,030) 35.8 (121,885) 45.9 (156,560) 68.0 (232,085) Condensing temperature for all above conditions: 52°C (125° F) Refrigerant type for all models: R-407C Refrigerant Charge per Circuit - kg (lbs) 2.8 (6.17) 3.9 (8.6) 4.4 (9.7) 3.9 (8.6) 4.6 (10.1) Compressor Information – COP** (ARI*** Conditions): 7.2°C (45°F) Evaporating, 54°C (130°F) Condensing Number of compressors 1 1 2 2 2 COP 3.0 3.0 3.0 3.0 3.1 Evaporator Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 5 Face Velocity - m/min (ft/min) 120 (393) 104 (342) 117 (383) 130 (425) 132 (432) * Nominal Rating Point ** Coefficient of Performance *** Air Conditioning and Refrigeration Institute 54 InRoom Precision AC Tech Data Manual Fluid Cooled (Glycol 0%) Continued PG211 Cabinet Size 1 PG311 Cabinet Size 2 PG452 Cabinet Size 3 PG612 Cabinet Size 4 PG862 Cabinet Size 5 Fan Information Number of Fans 1 1 2 2 3 Air Flow - M³/hr (CFM) 7493 (4,410) 10007 (5,890) 14000 (8,240) 20116 (11,890) 24007 (14,130) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 75.40 79.20 77.40 83.20 81.50 Total Fan Power Consumption - kW (hp) 1.7 (2.3) 2.0 (2.7) 3.1 (4.2) 6.1 (8.2) 6.2 (8.3) Condenser Data Total Heat Rejection (THR) - kW (BTU/hr) 26.5 (90,300) 39.1 (133,300) 58.4 (199,400) 77.4 (264,200) 113.3 (386,600) Flow rate - L/m (GPM) 48.5 (12.8) 71.5 (18.9) 101.8 (26.9) 145.0 (38.3) 206.7 (54.6) Total pressure drop water side - kPa (ft) 51.4 (17.2) 54.4 (18.2) 52.3 (17.5) 68.8 (23.0) 84.9 (28.4) Valve size - mm (in) 20 (0.75) 25 (1.0) 20 (0.75) 25 (1.0) 25 (1.0) Connection Sizes Condenser In/Out - mm (in) 28 (1 1/8) 35 (1 3/8) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1) 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU/hr) - Includes Motor Heat 400 V 12.0 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) Number of Stages 2 3 3 3 3 Downflow Filters - mm Quantities 700 x 508 x 47 G4 1 N/A N/A N/A N/A 1050 x 453 x 47 G4 N/A 2 1 1 1 1050 x 398 x 47 G4 N/A 1 3 4 5 Upflow Filters - mm Quantities 700 x 340 x 47 G4 N/A 1 N/A 1 1 700 x 332 x 47 G4 N/A 1 N/A N/A 1 700 x 502 x 47 G4 N/A 1 1 1 1 700 x 508 x 47 G4 N/A N/A 1 1 2 700 x 516 x 47 G4 1 N/A 1 N/A N/A Physical Data Weight - kg (lb) 356 (785) 460 (1014) 564 (1243) 693 (1528) 825 (1819) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) 2550 (100.39) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) 890 (35) InRoom Precision AC Tech Data Manual 55 Fluid Cooled (Glycol 40%) with CW - 50Hz Operational Mode: Fluid Cooled (Glycol 40%) Net Cooling Capacity PGCW211 Cabinet Size 1 PGCW311 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 19.4 (66,120) 28.2 (96,235) 41.3 (140,980) 53.2 (181,545) 79.6 (271,605) Sensible - kW (BTU/hr) 19.4 (66,120) 28.2 (96,235) 39.4 (135,000) 53.2 (181,545) 72.8 (248,615) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 17.4 (59,280) 25.9 (88,540) 38.3 (130,625) 49.0 (167,295) 72.2 (246,335) Sensible - kW (BTU/hr) * 17.4 (59,280) 25.9 (88,540) 38.3 (130,625) 49.0 (167,295) 72.2 (246,335) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 17.4 (59,280) 25.9 (88,540) 38.3 (130,625) 49.1 (167,580) 72.4 (247,000) Sensible - kW (BTU/hr) 17.4 (59,280) 25.9 (88,540) 38.3 (130,625) 49.1 (167,580) 72.4 (247,000) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 16.6 (56,715) 24.9 (84,930) 36.5 (124,450) 47.0 (160,455) 69.1 (235,980) Sensible - kW (BTU/hr) 16.6 (56,715) 24.9 (84,930) 36.5 (124,450) 47.0 (160,455) 69.1 (235,980) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 16.6 (56,715) 24.9 (84,930) 36.5 (124,450) 47.0 (160,455) 69.1 (235,980) Sensible - kW (BTU/hr) 16.6 (56,715) 24.9 (84,930) 36.5 (124,450) 47.0 (160,455) 69.1 (235,980) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 16.1 (55,100) 24.0 (81,985) 35.2 (120,270) 45.4 (154,945) 67.0 (228,570) Sensible - kW (BTU/hr) 16.1 (55,100) 24.0 (81,985) 35.2 (120,270) 45.4 (154,945) 67.0 (228,570) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 16.1 (55,100) 24.0 (81,985) 35.2 (120,270) 45.4 (154,945) 67.0 (228,570) Sensible - kW (BTU/hr) 16.1 (55,100) 24.0 (81,985)) 35.2 (120,270) 45.4 (154,945) 67.0 (228,570) Condensing temperature for all above conditions: 52°C (125° F) Refrigerant type for all models: R-407C Refrigerant Charge per Circuit - kg (lbs) 2.8 (6.17) 3.9 (8.6) 4.4 (9.7) 3.9 (8.6) 4.6 (10.1) Compressor Information – COP** (ARI*** Conditions): 7.2°C (45°F) Evaporating, 54°C (130°F) Condensing Number of compressors 1 1 2 2 2 COP 3.0 3.1 3.0 3.3 3.0 Evaporator Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 5 Face Velocity - m/min (ft/min) 125 (410) 104 (342) 117 (383) 124 (408) 141 (461) Condenser Data THR - kW (BTU/hr) 26.5 (90,300) 39.1 (133,100) 58.2 (198,600) 77.3 (263,800) 113.3 (386,600) Flow rate - L/m (GPM) 58.3 (15.4) 83.3 (22.0) 116.6 (30.8) 160.1 (42.3) 218.4 (57.7) Total pressure drop water side - kPa (ft) 78.6 (26.3) 78.9 (26.4) 66.4 (22.2) 88.5 (29.6) 99.0 (33.1) Valve size 20 (0.75) 25 (1.0) 32 (1.25) 32 (1.25) 40 (1.5) Temperature medium in - °C (°F) 40.5°C (105°F) 40.5°C (105°F) 40.5°C (105°F) 40.5°C (105°F) 40.5°C (105°F) Temperature medium in - °C (°F) 46.1°C (115°F) 46.1°C (115°F) 46.1°C (115°F) 46.1°C (115°F) 46.1°C (115°F) Connection Sizes In/Out - mm (in) 28 (1 1/8) 35 (1 3/8) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) * Nominal Rating Point ** Coefficient of Performance *** Air Conditioning and Refrigeration Institute 56 InRoom Precision AC Tech Data Manual Operational Mode: Chilled Water Net Cooling Capacity - 7.2°C (45°F) EWT PGCW211 Cabinet Size 1 PGCW311 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 34.3 (117,040) 48.6 (165,965) 61.5 (210,045) 83.6 (285,285) 104.3 (355,965) Sensible - kW (BTU/hr) 25.9 (88,540) 36.6 (124,830) 47.0 (160,455) 63.1 (215,270) 78.5 (268,090) Flow Rate - L/m (GPM) 98.4 (26.0) 138.2 (36.5) 166.9 (44.1) 243.4 (64.3) 297.5 (78.6) Total pressure drop water side - kPa (ft) 88.8 (29.7) 58.0 (19.4) 68.2 (22.8) 76.2 (25.5) 57.1 (19.1) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 34.8 (118,940) 47.9 (163,400) 60.2 (205,485) Sensible - kW (BTU/hr) * 20.0 (68,115) 27.7 (94,620) 34.8 (118,940) 47.9 (163,400) 57.6 (196,460) Flow Rate - L/m (GPM) 59.4 (15.7) 81.4 (21.5) 98.0 (25.9) 146.1 (38.6) 182.8 (48.3) Total pressure drop water side - kPa (ft) 32.0 (10.7) 19.1 (6.4) 22.4 (7.5) 26.9 (9.0) 20.3 (6.8) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 34.8 (118,940) 47.9 (163,400) 60.2 (205,485) Sensible - kW (BTU/hr) 20.0 (68,115) 27.7 (94,620) 34.8 (118,940) 47.9 (163,400) 57.6 (196,460) Flow Rate - L/m (GPM) 59.4 (15.7) 81.4 (21.5) 98.0 (25.9) 146.1 (38.6) 182.8 (498.3) Total pressure drop water side - kPa (ft) 32.0 (10.7) 19.1 (6.4) 22.4 (7.5) 26.9 (9.0) 20.3 (6.8) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 27.3 (93,005) 37.2 (127,110) 48.6 (165,965) Sensible - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 27.3 (93,005) 37.2 (127,110) 48.6 (165,965) Flow Rate - L/m (GPM) 49.2 (13.0) 67.0 (17.7) 78.7 (20.8) 117.3 (31.0) 151.0 (39.9) Total pressure drop water side - kPa (ft) 21.8 (7.3) 13.2 (4.4) 14.7 (4.9) 18.2 (6.1) 14.1 (4.7) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 27.3 (93,005) 37.2 (127,110) 48.6 (165,965) Sensible - kW (BTU/hr) 16.1 (55,100) 22.4 (76,475) 27.3 (93,005) 37.2 (127,110) 48.6 (165,965) Flow Rate - L/m (GPM) 49.2 (13.0) 67.0 (17.7) 78.7 (20.8) 117.3 (31.0) 151.0 (39.9) Total pressure drop water side - kPa (ft) 21.8 (7.3) 13.2 (4.4) 14.7 (4.9) 18.2 (6.1) 14.1 (4.7) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 22.2 (75,810) 29.8 (101,745) 39.1 (133,570) Sensible - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 22.2 (75,810) 29.8 (101,745) 39.1 (133,570) Flow Rate - L/m (GPM) 42.4 (11.2) 57.2 (15.1) 65.9 (17.4) 97.3 (25.7) 125.3 (33.1) Total pressure drop water side - kPa (ft) 16.1 (5.4) 9.6 (3.2) 11.1 (3.7) 12.3 (4.1) 10.5 (3.5) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 22.2 (75,810) 29.8 (101,745) 39.1 (133,570) Sensible - kW (BTU/hr) 13.7 (46,645) 18.9 (64,505) 22.2 (75,810) 29.8 (101,745) 39.1 (133,570) Flow Rate - L/m (GPM) 42.4 (11.2) 57.2 (15.1) 65.9 (17.4) 97.3 (25.7) 125.3 (33.1) Total pressure drop water side - kPa (ft) 16.1 (5.4) 9.6 (3.2) 11.1 (3.7) 12.3 (4.1) 10.5 (3.5) Valve Size - mm (in) 25 (1.0) 32 (1.25) 32 (1.25) 40 (1.5) 50 (2.0) Temperature medium in - °C (°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) 7.2°C (45°F) Temperature medium in - °C (°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) 12.8°C (55°F) Chilled Water Coil Face Area - m² (ft²) 0.77 (8.32) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 4 4 Face Velocity - m/min (ft/min) 161 (529) 142 (466) 156 (512) 173 (568) 179 (588) Connection Sizes In/Out - mm (in) 35 (1-3/8) 35 (1-3/8) 42 (1-5/8) 54 (2-1/8) 54 (2-1/8) * Nominal Rating Point InRoom Precision AC Tech Data Manual 57 Information common to both modes PGCW211 Cabinet Size 1 PGCW311 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 Connection Sizes Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Fan Information Number of Fans 1 1 2 2 3 Air Flow - M³/hr (CFM) 7493 (4,410) 10007 (5,890) 14000 (8,240) 19267 (11,390) 24007 (14,130) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 76.6 79.7 78.6 83.3 82.7 Total Fan Power Consumption - kW (hp) 2.0 (2.7) 2.3 (3.1) 3.6 (4.8) 6.2 (8.3) 7.3 (9.8) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1) 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU/hr) - Includes Motor Heat 400 V 12.0 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 27 (92210.4) Number of Stages 2 3 3 3 3 Downflow Filters - mm Quantities 700 x 508 x 47 G4 1 N/A N/A N/A N/A 1050 x 453 x 47 G4 N/A 2 1 1 1 1050 x 398 x 47 G4 N/A 1 3 4 5 Upflow Filters - mm Quantities 700 x 340 x 47 G4 N/A 1 N/A 1 1 700 x 332 x 47 G4 N/A 1 N/A N/A 1 700 x 502 x 47 G4 N/A 1 1 1 1 700 x 508 x 47 G4 N/A N/A 1 1 2 700 x 516 x 47 G4 1 N/A 1 N/A N/A Physical Data Weight - kg (lb) 377 (831) 490 (1080) 608 (1340) 751 (1656) 900 (1984) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) 2550 (100.39) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) 890 (35) 58 InRoom Precision AC Tech Data Manual Fluid Cooled (Glycol 40%) with Economizer - 50Hz Operational Mode: Fluid Cooled (Glycol 40%) - Summer Net Cooling Capacity PGE211 Cabinet Size 2 PGE311 Cabinet Size 3 PGE452 Cabinet Size 4 PGE612 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 19.8 (67,450) 29.3 (100,130) 43.3 (147,820) 57.6 (196,460) Sensible - kW (BTU/hr) 19.8 (67,450) 29.3 (100,130) 43.3 (147,820) 57.6 (196,460) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 18.7 (63,840) 27.2 (92,720) 40.1 (136,800) 53.2 (181,545) Sensible - kW (BTU/hr) * 18.7 (63,840) 27.2 (92,720) 40.1 (136,800) 53.2 (181,545) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 18.7 (63,840) 27.2 (92,720) 40.1 (136,800) 53.2 (181,545) Sensible - kW (BTU/hr) 18.7 (63,840) 27.2 (92,720) 40.1 (136,800) 53.2 (181,545) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 17.8 (60,610) 26.1 (89,110) 38.2 (130,340) 50.6 (172,805) Sensible - kW (BTU/hr) 17.8 (60,610) 26.1 (89,110) 38.2 (130,340) 50.6 (172,805) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 17.8 (60,610) 26.1 (89,110) 38.2 (130,340) 50.6 (172,805) Sensible - kW (BTU/hr) 17.8 (60,610) 26.1 (89,110) 38.2 (130,340) 50.6 (172,805) 21.1°C DB, 14.0°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 17.4 (59,280) 25.2 (85,880) 36.9 (126,065) 49.4 (168,530) Sensible - kW (BTU/hr) 17.4 (59,280) 25.2 (85,880) 36.9 (126,065) 49.4 (168,530) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 17.4 (59,280) 25.2 (85,880) 36.9 (126,065) 49.4 (168,530) Sensible - kW (BTU/hr) 17.4 (59,280) 25.2 (85,880) 36.9 (126,065) 49.4 (168,530) Condensing temperature for all above conditions: 52°C (125°F) Glycol 40% temperature for all above conditions: Inlet temperature 40.5°C (105°F) - Outlet temperature 46.1°C (115°F) Refrigerant type for all models: R-407C Refrigerant Charge per Circuit - kg (lbs) 3.9 (8.6) 4.4 (9.7) 3.9 (8.6) 4.6 (10.1) Refrigeration Circuits 1 1 2 2 Compressor Information – COP** (ARI*** Conditions): 7.2°C (45°F) Evaporating, 54°C (130°F) Condensing Number of compressors 1 1 2 2 COP 3.0 3.1 3.0 3.1 Evaporator Coil Face Area - m² (ft²) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 5 Face Velocity - m/min (ft/min) 94 (309) 114 (375) 125 (411) 153 (502) Condenser Data THR - kW (BTU/hr) 26.5 (90,300) 39.6 (135,100) 59.4 (202,600) 79.6 (271,800) Flow rate - L/m (GPM) 58.3 (15.4) 90.1 (23.8) 129.8 (34.3) 158.2 (41.8) Total pressure drop water side - kPa (ft) 41.3 (13.8) 38.9 (13.0) 56.5 (18.9) 42.2 (14.1) 2-way valve size 32 (1.25) 40 (1.5) 32 (1.25) 40 (1.5) Connection Sizes In/Out - mm (in) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) 54 (2 1/8) * Nominal Rating Point ** Coefficient of Performance *** Air Conditioning and Refrigeration Institute InRoom Precision AC Tech Data Manual 59 Operational Mode: Fluid Cooled (Glycol 40%) - Winter Net Cooling Capacity PGE211 Cabinet Size 2 PGE311 Cabinet Size 3 PGE452 Cabinet Size 4 PGE612 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH Total - kW (BTU/hr) 19.8 (67,450) 29.3 (99,845) 38.5 (131,290) 49.5 (168,910) Sensible - kW (BTU/hr) 19.8 (67,450) 28.3 (96,615) 38.5 (131,290) 49.5 (168,910) Flow rate - L/m (GPM) 58.3 (15.4) 90.1 (23.8) 129.8 (34.3) 158.2 (41.8) Total pressure drop water side - kPa (ft) 29.6 (9.9) 29.9 (10.0) 48.7 (16.3) 37.7 (12.6) 23.9°C DB, 16.9°C WB (75°F DB, 62.5°F WB) 50% RH Total - kW (BTU/hr) 17.5 (59,660) 24.9 (84,930) 32.7 (111,530) 41.5 (141,645) Sensible - kW (BTU/hr) * 17.5 (59,660) 24.9 (84,930) 32.7 (111,530) 41.5 (141,645) Flow rate - L/m (GPM) 58.3 (15.4) 90.1 (23.8) 129.8 (34.3) 158.2 (41.8) Total pressure drop water side - kPa (ft) 29.6 (9.9) 29.9 (10.0) 48.7 (16.3) 37.7 (12.6) 23.9°C DB, 16.1°C WB (75°F DB, 61°F WB) 45% RH Total - kW (BTU/hr) 17.5 (59,660) 24.9 (84,930) 32.7 (111,530) 41.5 (141,645) Sensible - kW (BTU/hr) 17.5 (59,660) 24.9 (84,930) 32.7 (111,530) 41.5 (141,645) Flow rate - L/m (GPM) 58.3 (15.4) 90.1 (23.8) 129.8 (34.3) 158.2 (41.8) Total pressure drop water side - kPa (ft) 29.6 (9.9) 29.9 (10.0) 48.7 (16.3) 37.7 (12.6) 22.2°C DB, 15.5°C WB (72°F DB, 60°F WB) 50% RH Total - kW (BTU/hr) 15.7 (53, 485) 22.3 (76,190) 29.0 (98,895) 36.9 (126,065) Sensible - kW (BTU/hr) 15.7 (53, 485) 22.3 (76,190) 29.0 (98,895) 36.9 (126,065) Flow rate - L/m (GPM) 58.3 (15.4) 90.1 (23.8) 129.8 (34.3) 158.2 (41.8) Total pressure drop water side - kPa (ft) 29.6 (9.9) 29.9 (10.0) 48.7 (16.3) 37.7 (12.6) 22.2°C DB, 14.8°C WB (72°F DB, 58.6°F WB) 45% RH Total - kW (BTU/hr) 15.7 (53, 485) 22.3 (76,190) 29.0 (98,895) 36.9 (126,065) Sensible - kW (BTU/hr) 15.7 (53, 485) 22.3 (76,190) 29.0 (98,895) 36.9 (126,065) Flow rate - L/m (GPM) 58.3 (15.4) 90.1 (23.8) 129.8 (34.3) 158.2 (41.8) Total pressure drop water side - kPa (ft) 29.6 (9.9) 29.9 (10.0) 48.7 (16.3) 37.7 (12.6) 21.1°C DB, 14.8°C WB (70°F DB, 58.5°F WB) 50% RH Total - kW (BTU/hr) 14.4 (49,305) 20.6 (70,300) 26.7 (91,105) 33.9 (115,710) Sensible - kW (BTU/hr) 14.4 (49,305) 20.6 (70,300) 26.7 (91,105) 33.9 (115,710) Flow rate - L/m (GPM) 58.3 (15.4) 90.1 (23.8) 129.8 (34.3) 158.2 (41.8) Total pressure drop water side - kPa (ft) 29.6 (9.9) 29.9 (10.0) 48.7 (16.3) 37.7 (12.6) 21.1°C DB, 14.0°C WB (70°F DB, 57.2°F WB) 45% RH Total - kW (BTU/hr) 14.4 (49,305) 20.6 (70,300) 26.7 (91,105) 33.9 (115,710) Sensible - kW (BTU/hr) 14.4 (49,305) 20.6 (70,300) 26.7 (91,105) 33.9 (115,710) Flow rate - L/m (GPM) 58.3 (15.4) 90.1 (23.8) 129.8 (34.3) 158.2 (41.8) Total pressure drop water side - kPa (ft) 29.6 (9.9) 29.9 (10.0) 48.7 (16.3) 37.7 (12.6) Condensing temperature for all above conditions: 52°C (125°F) Glycol 40% temperature for all above conditions: Inlet temperature 40.5°C (105°F) - Outlet temperature 46.1°C (115°F) Cooling Fluid (40% Glycol) Coil Face Area - m² (ft²) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 5 Face Velocity - m/min (ft/min) 94 (309) 114 (375) 125 (411) 153 (502) 2-way valve size 32 (1.25) 40 (1.5) 32 (1.25) 40 (1.5) Connection Sizes In/Out - mm (in) 35 (1 3/8) 35 (1 3/8) 42 (1 5/8) 54 (2 1/8) * Nominal Rating Point 60 InRoom Precision AC Tech Data Manual Information common to both modes PGE211 Cabinet Size 2 PGE311 Cabinet Size 3 PGE452 Cabinet Size 4 PGE612 Cabinet Size 5 Connection Sizes Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Fan Information Number of Fans 1 2 2 3 Air Flow - M³/hr (CFM) 6643 (3,910) 10007 (5,890) 14000 (8,240) 20507 (12,070) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 71.2 71.9 76.7 79.5 Total Fan Power Consumption - kW (hp) 0.7 (0.9) 1.4 (1.9) 2.5 (43.4) 4.7 (6.3) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1 Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU) - Includes Motor Heat 400 V 12.0 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) Number of Stages 2 3 3 3 Downflow Filters - mm Quantities 1050 x 453 x 47 G4 2 1 1 1 1050 x 398 x 47 G4 1 3 4 5 Upflow Filters - mm Quantities 700 x 340 x 47 G4 1 N/A 1 1 700 x 332 x 47 G4 1 N/A N/A 1 700 x 502 x 47 G4 1 1 1 1 700 x 508 x 47 G4 N/A 1 1 2 700 x 516 x 47 G4 N/A 1 N/A N/A Physical Data Weight - kg (lb) 470 (1036) 584 (1287) 716 (1578) 893 (1969) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.9) 2150 (84.65) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) InRoom Precision AC Tech Data Manual 61 50Hz InRoom Electrical Specifications Air Cooled (DX) and Fluid Cooled (Glycol) Electrical Data With Reheat and Humidification Without Reheat and Humidification Compressor Data Model Size Airflow Pattern Cooling System Voltage (3ph/ 50Hz) FLA FLA LRA RLA 211 U/D A/G/ACW/ GCW 400 32 14.7 75 10.0 GE 40.9 14.7 75 10.0 311 U/D A/G/ACW/ GCW 400 48.2 22.0 114 17.3 GE 52.9 26.7 114 17.3 452 U/D A/G/ACW/ GCW 400 59.6 33.4 100 12.0 GE 72.6 33.4 100 12.0 612 U/D A/G/ACW/ GCW 400 83.2 44.0 114 17.3 GE 87.9 48.7 114 17.3 862 U/D A/G/ACW/ GCW 400 102.3 63.1 135 24.5 Chilled Water (CW) Electrical Data With Reheat and Humidification Without Reheat and Humidification Model Size Airflow Pattern Cooling System Voltage (3ph/ 50Hz) FLA FLA 400 D CW 400 29.5 3.5 400 U CW 400 30.7 4.7 660 U/D CW 400 43.1 8.2 900 U/D CW 400 51.8 9.4 1100 U/D CW 400 64.8 9.4 1500 U/D CW 400 69.5 14.1 62 InRoom Precision AC Tech Data Manual General Specifications Technical Specifications Application Limits The InRoom precision air conditioning units operate within the following ranges: Room Conditions: Between 18°C (64°F), 40% Relative Humidity (RH), and 27°C (81°F), 55% RH Outdoor ambient conditions: Lower limit: Standard air cooled condenser: -28.9°C (-20°F) Optional Extreme Low Temperature Kit: -34.4°C (-30°F) Upper limit: Standard air cooled condenser: 35°C (95°F) High temperature air cooled condenser: 46.1°C (115°F) Voltage: 460V / 3ph / 60 Hz 208-230V / 3ph / 60 Hz 400V / 3ph / 50 Hz Voltage tolerance: +/- 10% Voltage tolerance: +/- 10% Voltage imbalance: <3% Voltage imbalance: <3% Frequency: 60 Hz +/- 1% Frequency: 50 Hz +/- 1% Chilled water-/cooling water pipes: Maximum water head pressure: 10 bar (145 psi) Maximum equivalent length of piping between the cooling unit and the air-cooled condenser: 60 m (200 ft) Maximum level difference between the condenser and the cooling unit: 5 m (16 ft) when the condenser is below the cooling unit Storage conditions: Temperature: -20 to +42°C (-4 to +107.6°F) Humidity: (% RH): 5 to 95 Atmospheric pressure: 70 to 110 kPa (10 to 16 psi) Design Conditions Return air conditions for evaporator capacity (DX): 24°C (75°F) 50% RH Return air conditions for cooling capacity (CW): 24°C (75°F) 50% RH Entering water temperature (EWT) for CW coil: 7°C (44.6°F) Leaving water temperature (LWT) for CW coil: 12°C (53.6°F) Condensing temperature: 45°C (113°F) Maximum condensing temperature: 60°C (140°F) Cooling fluid (DX): 40% Glycol Fluid inlet temperature (G): 30°C (86°F) Fluid outlet temperature (G): 40°C (104°F) Chilled water medium (CW): 0% Glycol Data is valid for these electrical ratings: 460V / 3ph / 60 Hz and 400V / 3ph / 50 Hz Downflow units with an external static pressure: 20 Pa (0.08 in WC) Upflow units with an external static pressure: 20 Pa (0.08 in WC) InRoom Precision AC Tech Data Manual 63 Transporting and Storage Delivery of the unit The cooling unit is mounted on a pallet, wrapped in plastic film, and surrounded with cardboard for added protection. The unit must be transported in the upright position. PAXXX models are delivered with 1 kg. (2.2 lb) refrigerant charge. PGXXX models are delivered with a complete refrigerant charge. Check the unit against the shipping invoice to verify contents. Check the unit for damage. In case of damage, first notify the carrier of a claim. Moving the unit Use a forklift to move the cooling unit while it is still packaged on the pallet. Make sure the unit is upright when moving it. Do not move the unit on rollers and do not move it on a forklift without a pallet. The cooling unit can be moved with lifting devices and ropes. The ropes must be fixed to the pallet and the upper edges of the unit must be protected to avoid damage. Storage If the unit is placed into storage before being installed, make sure to protect it from damage and corrosion. • Make sure that the water connections have protective covers. If the unit will be stored for longer than two months, the piping should be filled with nitrogen. • The temperature of the storage area should not exceed 42°C (107.6°F). • The unit should not be stored where it will be exposed to direct sunlight. • Do not leave the unit outside or in any storage area that allows the unit to be exposed to the elements. • Store the unit in the original packaging when possible to avoid damage and corrosion. 64 InRoom Precision AC Tech Data Manual Guidelines for Installation Room preparation During the design of the room, consideration should be given to the following factors: ease of entry for the system, floor-loading factors, and accessibility of piping and wiring. The room must be sealed with a vapor barrier to minimize migration of moisture. Polyethylene film (plastic sheeting) is a good vapor barrier for ceiling and wall applications. Rubber- or plastic-based paints should be applied to concrete floors and walls. The room should be thoroughly insulated to minimize thermal loads and make-up air (if required) should be preconditioned to reduce additional temperature, filtration, and moisture loads. A room using a raised-floor plenum for air distribution should have a finished floor height no less than (305 mm) 12 in. The area under the floor should be free from obstructions. Pay special attention to the location of pipe chases, electrical conduits and other obstructions under the floor. These objects can block air circulation and cause loss of air pressure, thus reducing system efficiency and causing hot spots in the room. Unit location The location of the unit is important for efficient and balanced environmental control in the room. Contact an APC representative for assistance in locating equipment in the room. If poorly installed, erratic control or mechanical failure can result. Service access At least 1 meter (39 in) of clear space must be left in front of the unit for routine service (filters, humidifier). Downflow units with a ducted return should have a field-installed access panel to allow for filter replacement. Receiving the unit The unit has been completely tested and inspected prior to shipment. To ensure that the unit received is in excellent condition, perform a careful inspection of the crating and the unit immediately upon receipt. Verify that all parts ordered were received as specified and that the unit is the correct size and voltage necessary to fulfill the environmental control needs. Report any damage discovered to the freight carrier. If necessary, contact the APC field service department for help in repairing or replacing damaged parts. While APC is not responsible for damage incurred in transit, APC will work with you to make sure that there are no undue delays in the system start-up. Rigging The unit is manufactured with a formed steel frame for maximum strength and unit integrity. However, as with all electrical and mechanical equipment, take care with proper rigging of the unit. When using a forklift to move the unit, use the shipping skid to protect the bottom of the unit. When hoisting the unit from above, use spreader bars to prevent damage to the unit. Floorstand Follow the directions provided with the floorstand for proper installation. Utility connections All connections are made through the bottom left of the unit (the left side of upflow discharge units) for ease of service connections. See the installation manual for pipe sizes and specific locations for the unit. Power to the unit The unit uses 3-phase power for operation. Power connections are routed through the bottom of the unit. InRoom Precision AC Tech Data Manual 65 Chilled Water Power Supply Inlet Location a 2 2 0 3 a n Illustration Number Cabinet Size Airflow Direction 1 and 2 Downflow 1 and 2 Upflow 3 through 5 Downflow 3 through 5 Upflow 66 InRoom Precision AC Tech Data Manual Piping Connections Downflow Chilled Water Cooling Units Model PCW400 PCW660 PCW900 PCW1100 PCW1500 In/Out Pipe Size 35 mm (1 3/8 in) 42 mm (1 5/8 in) 54 mm (2 1/8 in) 70 mm (2 3/4 in) 70 mm (2 3/4 in) Note: The 70 mm (2 3/4 in) pipe size on models CPW1100 and CPW1500 is decreased after the screw connection to 64 mm (2 1/2 in) diameter for the external pipe connection. PCW400 View from the bottom of the unit. ) 8 . 7 3 ( 0 69 ) 1. 6 ( 5 51 ) 9. 2 ( 37 0 * Dimensions are in mm (in). 76 (3) 142 (5.6) 866 (34.1) a 35 82 a n Item Description Water outlet, 35 mm (1 3/8 in) ID Water inlet, 35 mm (1 3/8 in) ID Condensate drain, 25 mm (1 in) NPT Rear of unit Humidifier inlet, 6 mm (1/4 in) compression fitting Control wire inlet, 10 mm (0.375 in) pilot hole Power wire inlet, 10 mm (0.375 in) pilot hole InRoom Precision AC Tech Data Manual 67 PCW660 View from the bottom of the unit ) ) ) ) 9 5 . . 0 5 3 . 9 . 5 0 4 8 ( ( 0 2 ( ( 0 8 6 0 6 4 0 3 2 2 0 1 0 1 7 * Dimensions are in mm (in). 115 (4.5) 679 (26.7) 71 (2.8) 866 (34.1) a 5 5 8 2 a n Item Description Power wire inlet, 10 mm (0.375 in) pilot hole Water outlet, 42 mm (1 5/8 in) ID Control wire inlet, 10 mm (0.375 in) pilot hole Water inlet, 42 mm (1 5/8 in) ID Condensate drain, 25 mm (1 in) NPT Rear of unit Humidifier inlet, 6 mm (1/4 in) compression fitting 68 InRoom Precision AC Tech Data Manual PCW900 View from the bottom of the unit ) ) ) ) 3 . ) 6 7 3 7 . . . 0 ) 4. 2 ( 06 7. 4 ( 02 1 0 3 ( 67 7 3 3 ( 55 8 6 3 ( 22 9 ) 1. 4 ( 4 01 6 ( 0 17 1 82 (3.2) 132 (5.2) 866 (34.1) a 2 5 8 2 a n * Dimensions are in mm (in). Item Description Water inlet, 54 mm (2 1/8 in) ID Water outlet, 54 mm (2 1/8 in) ID Power wire inlet, 10 mm (0.375 in) pilot hole Control wire inlet, 10 mm (0.375 in) pilot hole Rear of unit Humidifier inlet, 6 mm (1/4 in) compression fitting Condensate drain, 25 mm (1 in) NPT InRoom Precision AC Tech Data Manual 69 PCW1100 View from the bottom of the unit. ) ) ) ) 1 5 2 . . 4 ) . . 3 1 ) 4 7 ) 8 8 . 4 4 4 ( ( 3 1 . 4 ( ( . ( 2 0 5 4 ( 2 6 ( 1 1 5 2 7 1 1 2 0 1 3 0 9 2 6 1 1 1 0 1 82 (3.2) 132 (5.2) a 4 5 8 2 866 (34.1)na* Dimensions are in mm (in). Item Description Water inlet, 70 mm (2 3/4 in) ID Water outlet, 70 mm (2 3/4 in) ID Power wire inlet, 10 mm (0.375 in) pilot hole Control wire inlet, 10 mm (0.375 in) pilot hole Rear of unit Humidifier inlet, 6 mm (1/4 in) compression fitting Condensate drain, 25 mm (1 in) NPT 70 InRoom Precision AC Tech Data Manual PCW1500 View from the bottom of the unit. ) ) ) ) 8 . 1 1 ) 4 8 . . . ) ) 4 9 4 6 0 . 1 4 ( . 3 3 . 3 4 ( ( ( ( 4 2 0 ( ( 6 8 1 6 1 3 6 1 5 1 1 7 0 0 6 1 7 8 9 1 2 82 (3.2) 132 (5.2) 866 (34.1) a 1 5 8 2 a n * Dimensions are in mm (in). Item Description Water inlet, 70 mm (2 3/4 in) ID Water outlet, 70 mm (2 3/4 in) ID Power wire inlet, 10 mm (0.375 in) pilot hole Control wire inlet, 10 mm (0.375 in) pilot hole Rear of unit Humidifier inlet, 6 mm (1/4 in) compression fitting Condensate drain, 25 mm (1 in) NPT InRoom Precision AC Tech Data Manual 71 Upflow Chilled Water Cooling Units On upflow cooling units the supply and return pipes and power cables can be introduced from either the left or right side through openings in the side wall. The actual connection points are on the right side. Left Side Connections Right Side Connections 230 (9.1) L7 60 L5 L3 L1 60 R1 R3 R5 R7 230 (9.1) 110 (4.3) 0 L8 L6 L4 L2 210 (8.3) 405 (15.9) 525 (20.7) 680 (26.8) R2 R4 R6 R8 210 (8.3) 365 (14.4) a 485 (19.1) 9 4 8 680 (26.8) 2 a n 110 (4.3) 0 Dimensions are in mm (in). Model PCW400 PCW660 PCW900 PCW1100 PCW1500 In/Out Pipe Size 35 mm (1 3/8 in) 42 mm (1 5/8 in) 54 mm (2 1/8 in) 70 mm (2 3/4 in) 70 mm (2 3/4 in) Left Side Openings Used L1, L2, L3, L4, L5, L6 L1, L2, L3, L4, L5, L6 L1, L2, L3, L4, L5, L6 L1, L2, L3, L4, L5, L6 L1, L2, L3, L4, L5, L6 Right Side Openings Used R1, R2, R3, R4, R5, R6 R3, R4, R5, R6 R1, R2, R3, R4, R5, R6 R1, R2, R3, R4 R1, R2, R3, R4 Note: The 70 mm (2 3/4 in) pipe size on models CPW1100 and CPW1500 is decreased to 64 mm (2 1/2 in) diameter after the screw connection for the external pipe connection. 72 InRoom Precision AC Tech Data Manual Refrigerant Piping a 1 5 0 3 a n Dimensions in mm (in). Model PA211 1 circuit PA311 1 circuit PA452 2 circuits PA612 2 circuits PA862 2 circuits Pressure Line 16 mm (5/8 in) 22 mm (7/8 in) 16 mm(5/8 in) 22 mm (7/8 in) 22 mm (7/8 in) Liquid Line 12 mm (1/2 in) 16 mm (5/8 in) 22 mm (7/8 in) 16 mm (5/8 in) 16 mm (5/8 in) Considerations The refrigerant connections are located near the compressor and are labelled pressure pipe and liquid pipe. Models containing two circuits will be labelled pressure pipe 1 and pressure pipe 2. To ensure oil return in ascending hot gas lines, particularly at partial load, the minimum refrigeration capacity must not fall below the value on the table below. Minimum refrigeration outputs required for oil transportation in rising pressure lines for R407C refrigerant at dew point of 48°C (118.4°F) Pipe Diameter mm (in) 15 (5/8) 18 (3/4) 22 (7/8) 28 (1 1/8) 35 (1 3/8) 42 (1 5/8) Refrigerant Capacity kW (MBH) 4.41 (15) 5.17 (17.7) 7.14 (24.4) 10.0 (34.2) 16.58 (56.6) 25.9 (88.4) The horizontal lines must always be routed with a slope towards the condenser. Establish the shortest route for pipework from the unit to the condenser. InRoom Precision AC Tech Data Manual 73 InRoom Guide Specifications PART 1 GENERAL 1.01 SUMMARY A. The InRoom environmental control system shall be designed specifically for precision temperature and humidity control applications. It will automatically monitor and control heating, cooling, humidifying, dehumidifying, and filtering functions for the conditioned space. The system shall be built to the highest quality engineering and manufacturing standards, and shall be floor mounted and configured for ____(up/down) discharge of conditioned airflow, with draw through air pattern, to provide uniform air distribution over the entire face of the coil. 1.02 DESIGN REQUIREMENTS A. The system shall be as described in the following specification as manufactured by APC. 1. Model: ____________________________ 2. Total cooling capacity: _______________ kW (MBH) 3. Sensible cooling capacity: _____________ kW (MBH) 4. Return air temperature: _______________ º C (º F) DB 5. Return air temperature: _______________ º C (º F) WB 6. Humidity: __________________________% RH 7. Air quantity: _______________________ L/s (CFM) 8. External Static Pressure: _______________Pa (PSI) 9. Humidifier capacity: _________________ kg/hr (lb/hr) 10.Electrical supply: ________ V, _________ ph, _____ HZ 1.03 SUBMITTALS A. Submittals shall be provided with the proposal and shall include: capacity data, electrical data, physical data, electrical connection drawing and piping connection drawing. 1.04 QUALITY ASSURANCE A. The system shall be completely factory-tested prior to shipment. Testing shall include, but not be limited to: complete pressure and leak testing to ensure system integrity to include controls calibration and settings. Each system shall ship with a completed test report to verify completion of factory testing procedure. The system shall be ETL/CETL, NTRL listed, MCA, and the electrical system shall be UL Listed to UL 1995 and CSA 22.2 No. 236. 1.05 WARRANTY A. 1 year parts without factory start-up and 1 year parts and labor with factory start-up. 74 InRoom Precision AC Tech Data Manual PART 2 PRODUCT 2.01 STANDARD COMPONENTS A. CABINET CONSTRUCTION 1. Exterior panels: Shall be 16 gauge steel sheet metal for maximum strength. All exterior panels and frame are powder coated for durability. Front panels shall have removable hinges with a locking handle. The side panels are double wall construction with insulation between. Interior panel wall shall be insulated with 1/2 in (1.5 lb) density fiber insulation. Insulation shall be completely protected from the air stream by the panel wall or air blocks. Exterior frame and panel color shall have color values: L = 14.02, a = 0.13, b = 3.68. Main bezel color shall have color values: L = 13.44, a = 0.43, b = –2.63. 2. Frame: Shall be constructed of welded 16 gauge formed steel for maximum strength. 3. All units shall have full service access from the front, allowing the units to be placed side by side. B. ELECTRONICALLY COMMUTATED (EC) FANS 1. Electronically commutated (EC) Fans: The cooling unit shall be equipped with EC fan modules that have anti-vibration mountings to isolate each fan module from the structure of the cooling unit. The cooling unit shall be configured with a draw-through air pattern, to provide uniform air flow over the entire face of the coil. C. REFRIGERATION COMPONENTS 1. Dual Circuit Refrigeration System: The system shall operate under the coordination of the main controller. Suction and discharge pressures shall be monitored and electronically controllable. Each refrigeration system shall consist of a fully-protected scroll compressor, evaporator coil mounted over an anti-fungal, formed-plastic condensate drip pan, electronic expansion valve, hot gas bypass valve, filter-drier, sight glass, high pressure switch, and low pressure switch. 2. Scroll Compressors: The unit shall contain scroll compressors for optimized performance, efficiency and reliability. The heavy-duty scroll compressors shall be designed for year-round usage. Scroll compressors shall have Advanced Scroll Temperature Protection (ASTP) to protect the Scroll Compressor from excessively high discharge gas temperatures. Compressor crankcase heaters shall be a standard feature for all units with the Scroll Technology. 3. Electronic Expansion Valve: The unit shall contain an electronic expansion valve that is used to modulate the amount of refrigerant flow within the system. The EEV shall be constructed of stainless steel with ceramic slide and port parts for highly accurate flow and minimal wear. EEV has a fast reaction time (1.5 seconds), optimizing saturation of the evaporator coil. InRoom Precision AC Tech Data Manual 75 D. CONTROLLER 1. Controller: Shall be standard on each unit and provide precision control for the demanding requirements of Mission Critical Environments. 2. Monitoring and Configuration: The display shall allow monitoring and configuration of the precision air conditioning unit through a menu-based control. Functions include status reporting, setup, and temperature and humidity set points. Three LEDs report the operational status of the connected precision air conditioning unit. 3. Controls: The microprocessor shall come equipped with control keys that allow the user to navigate between menus, to select menu items, and to input alphanumeric information. 4. Alarms: The microprocessor controller shall activate a visible and audible alarm in the occurrence of any of the following events: a. Local Stop b. Compressor Low Pressure c. Compressor Failure d. E-heating Failure e. Humidifier Failure f. Humidifier 5uS g. Humidifier 20uS h. Fan Error i. Filter Clogged j. External Alarm k. Pump Failure l. Drycooler Failure m.Water Detector n. Room Temp Too High o. Room Humidity Too High p. Supply Temp Too High q. Supply Humidity Too High r. Room Temp Too Low s. Room Humidity Too Low t. Supply Temp Too Low u. Supply Humidity Too Low v. Water Temp Too High w.Water Temp Too Low x. Fire/Smoke Detector y. Sensor Failure z. Sensor Broken 5. Logging: The microprocessor controller shall log and display the 200 most recent events and alarms. Each alarm log shall contain time and date stamp as well as operating conditions at the time of occurrence. The controller shall display the run time hours for major components (compressors, heaters, humidifier, and blower motors). 76 InRoom Precision AC Tech Data Manual
Đăng ký:
Đăng Nhận xét (Atom)
Black & Decker Black&Decker Vacuum NV4820CN, homeappliance
Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...
-
Download! BERNINA® www.berninausa.com What is BSR? The BERNINA® Stitch Regulator The revolutionary Bernina Stitch Regulator (BSR) all...
-
Download! Power Vent & Power Direct Vent Replacement Parts No. Part Name and Description Repair Parts Illustration Repair Part...
-
Download! Service Handbook RESIDENTIAL HYBRID ELECTRIC HEAT PUMP WATER HEATER FOR MODELS: HPE10260H045DV (60 GAL.) HPE10280H045DV (...
Không có nhận xét nào:
Đăng nhận xét