Thứ Năm, 12 tháng 8, 2021

A.O. Smith SDV, homeappliance





Download!

Residential Gas Water Heaters PROMAX® PLUS HIGH RECOVER FEATURES HIGHEST RECOVERIES AND FIRST HOUR RATINGS Capacity/input combinations up to 98 gallons/75,100 BTUs produce recoveries up to 81 gallons per hour, with deliverable hot water up to 150 gallons. A. O. SMITH DYNACLEAN™ DIFFUSER DIP TUBE Helps reduce lime and sediment buildup, maximizes hot water output. Made from long lasting PEX cross-link polymer. GREEN CHOICE® GAS BURNER Patented "Eco-Friendly" design reduces NOx emissions by up to 33%, complies with Texas requirements for NOx emissions. COREGARD™ ANODE ROD A. O. Smith's exclusive aluminum anode has a stainless steel core, protects tank against corrosion longer versus ordinary mild steel anodes. PUSH-BUTTON PIEZO IGNITER Makes lighting pilot fast and easy with one-hand push-button spark ignition. Standard on C3 Technology ® models. HEAT TRAP NIPPLES* Factory installed on most models. DURABLE TAMPER-RESISTANT BRASS DRAIN VALVE THICK CFC-FREE FOAM INSULATION Improves efficiency. A. O. SMITH PERMAGLAS® GLASS COATING Protects steel tank from rust. FACTORY-INSTALLED TEMPERATURE AND PRESSURE (T&P) RELIEF VALVE Top-mounted T&P Valve available as option on C3 Technology models. CODE COMPLIANCE: UBC, CEC, SBCC, CABO, HUD, BOCA NATIONAL CODES, ASHRAE/IES 90.1-1999 AND 2004 NAECA DESIGN-CERTIFIED BY CSA INTERNATIONAL According to ANS Z21.10.1* standards governing storage-type water heaters. *75 and 100 models certified to ANS Z21.10.3 6-YEAR LIMITED TANK AND PARTS WARRANTY For complete information, consult written warranty or A. O. Smith Water Products Company. EQUIPPED WITH C3 TECHNOLOGY ® See other side. Revised September 2008 Series 100/101 ® Page 1 of 2 AOSRG45400 Residential Gas Water Heaters MODEL FIRST GALLON RECOVERY ENERGY BTU INPUT R DIMENSIONS (INCHES)DRAFT APPROX. NUMBER HOUR RATING CAPACITY 90°F RISE PER HOUR FACTOR PER HOUR NATURAL† VALUE A B C D E F HOOD OUTLET SHIPPING WEIGHT (LBS) (GPH) GCVT-40 88 38 48 0.60 50,000 16 58-1/2 54-3/4 20-1/2 13-3/8 8 48-7/8 4 138 172 GCVT-50 90 48 51 0.58 50,000 8 60-7/8 56-1/2 20 13-3/8 8 50-3/8 4 195 GCVX-50 93 50 67 0.58 65,000 16 63-7/8 59-1/2 22 15-1/2 8 54-1/8 4 215 GCV-65 116 65 67 0.57 65,000 16 65 60 24 15-1/2 8 54-1/4 4 FCG-75* N/A 74 81 N/A 75,100 16 61 57 26-1/2 14-3/4 16 50-1/4 4 275 350 FCG-100* N/A 98 81 N/A 75,100 10 68-1/2 65 27-3/4 15-3/16 16 57-3/8 4 Recovery capacity based on actual performance tests. Water Connections – 1" on 75-gallon model, 1-1/4" on 100-gallon model, 3⁄4" on all other models. * Not equipped with C3 Technology. 75 and 100 gallon models have factory installed (non heat trap) nipples, 75-gallon model has 80% efficiency, 998 BTU/hr. standby loss; 100-gallon model has 80% efficiency, 1146 BTU/hr. standby loss. † Propane Gas – GCVT-40: 47,000 BTU input; GCVT-50: 45,000 BTU input; GCVX-50: 55,000 BTU input; GCV-65: 62,500 BTU input. For 10-Year Tank and 6-Year Parts Warranty, change "G" to "X" in Model Number (example: XCVT-40), or change "F" to "P" in model number (example: PCG-75). The standard FVIR models are certified for installations to 7700 feet elevation. For high attitude versions of the 75 & 100-gallon models add SMR "S19" Flammable Vapor Ignition Resistant C3 Technology ® Water Heaters Corderite Combustion Containment (C3) design meets American National Standards Institute standards (ANS Z21.10.1) that deal with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline. Covered by four U.S. patents, C3 Technology gas water heaters feature a sealed combustion chamber with air intake screen and a fireproof Corderite flame arrestor built into the water heater base. In addition, a thermal cutoff (TCO) device, integral with the thermocouple, is designed to shut off gas flow to the burner and pilot if poor combustion is detected. If flammable vapors accidentally enter the HOT CONNECTION E C T&P VALVE 1/2" GAS ANODE ROD* COLD CONNECTION B A combustion chamber, the Corderite flame arrestor is designed so flames burn off the top surface and cannot escape down through the arrestor. CONNECTION F D A. Easy-to-light piezo igniter B. View port for easy burner inspection inside sealed combustion chamber *Location for optional top-mounted T&P Valve if ordered from factory. (C3 models only) For Technical Information and Automated Fax Service, call 800-527-1953. A.O. Smith Corporation reserves the right to make product changes or improvements without prior notice. Revised September 2008 Page 2 of 2 www.hotwater.com AOSRG45400

Không có nhận xét nào:

Đăng nhận xét

Black & Decker Black&Decker Vacuum NV4820CN, homeappliance

Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...