Thứ Năm, 12 tháng 8, 2021
A.O. Smith BTH 300A, BTH 400A, homeappliance
Download!
Solar control SGE Condensing Gas - Solar Water Heater SGE - 40/60 Fully room-sealed condensing high efficiency gas-solar water heater with integrated solar heat exchanger (95 % gross) • Maximum solar contribution through fully integrated intelligent solar controller • 1 control and display unit for the complete installation • Very small footprint because of integrated solar heat exchanger • Flexible flue options (maximum length 100 meters) • Thermocontrol for easy flexible control / fault diagnosis • Programmable for legionella purge cycle • All models suitable for natural or LP gas • Scale formation is reduced through the improved design and location of the heat exchanger • Very easy maintenance and installation • Remote control connection • Voltage-free contact for general fault indication Innovation has a name. SGE Technical specifications 0 0 4 6 E E G G S S Gas data natural gas 2H (G20) Input* kW 44.4 63.2 Output kW 42.0 59.7 Inlet pressure mbar 20 20 Burner pressure mbar 8.0 10 Gas consumption ** m3/h 4.2 6.0 Diameter main orifice mm 6.30 8.70 Max. flue gas temperature °C 80 80 Flue gas discharge kg/h 82.3 111.1 Gas data butane 3+ (G30) Input* kW 43.3 61.7 Output kW 42.0 59.7 Inlet pressure mbar 30 30 Burner pressure mbar - - Gas consumption ** kg/h 3.2 4.5 Diameter main orifice mm 3.10 4.00 Max. flue gas temperature °C 80 80 Flue gas discharge kg/h 82.1 109.9 Gas data propane 3+ (G31) Input* kW 43.5 61.8 Output kW 42.0 59.7 Inlet pressure mbar 30 30 Burner pressure mbar - - Gas consumption ** kg/h 3.1 4.4 Diameter main orifice mm 4.70 6.00 Max. flue gas temperature °C 80 80 Flue gas discharge kg/h 83.1 108.8 Draw-off capacity Storage l 370 370 Max. temperature setting °C 80 80 Tcold = 10ºC / Tset = 65ºC 30 min ∆T=44°C l 693 718 60 min ∆T=44°C l 1249 1302 90 min ∆T=44°C l 1805 1886 120 min ∆T=44°C l 2361 2470 Continuous ∆T=44°C l/h 821 1168 Heating up time ∆T=44°C min 15 10 30 min ∆T=50°C l 610 632 60 min ∆T=50°C l 1099 1146 90 min ∆T=50°C l 1588 1659 120 min ∆T=50°C l 2078 2173 Continuous ∆T=50°C l/h 722 1028 Heating up time ∆T=50°C min 17 12 30 min ∆T=55°C l 554 574 60 min ∆T=55°C l 999 1041 90 min ∆T=55°C l 1444 1509 120 min ∆T=55°C l 1889 1976 Continuous ∆T=55°C l/h 657 934 Heating up time ∆T=55°C min 19 13 Electrical data Power consumption W 275 275 Power supply VAC/Hz 230(-15% / +10 % VAC) / 50 (+/- 1 Hz) r General a b m Fan rotational speed at ignition r.p.m. 4920 5040 5 Working speed of fan r.p.m. 5520 6300 2 , 3 Pressure differential Pa 735/705 675/645 1 0 1 Diameter of air restrictor mm 28.0 34.0 d n Anodes - 4 4 a C Maximum working pressure bar 8 8 ° e 5 u l 1 a t Shipping data v a s s n Empty weight kg 245 245 o o i r t g Maximum weight kg 615 615 p n m o Weight incl. packaging kg 256 256 u s a t n Width packaging mm 870 870 a o d c Height packaging mm 2075 2075 s s a a Depth packaging mm 945 945 G G * * * SGE Dimensions 0 0 4 6 E E G G S S A Total height 2055 2055 C Position on pallet 490 490 D Diameter unit 705 705 E Depth 925 925 F Width 755 755 G Diameter flue 100/150 100/150 H Height flue pipe 1995 1995 Hx X-position flue 260 260 Hy Y-position flue 370 370 K Height gas / burner connection 1945 1945 M Height cold water inlet 185 185 N Height hot water outlet 2055 2055 Ny Y-position hot water outlet 205 205 P Height clean out 365 365 R Height drain valve 180 180 S Height T&P connection 1555 1555 T Height coil inlet 630 630 U Height coil outlet 305 305 V Height recirculation connection 1035 1035 W Height condens outlet 765 765 X Height inlet plate heat exchanger 1465 1465 Y Height outlet plate heat exchanger 855 855 Z Height connection electrical element 755 755 1 Cold water inlet R11/2 R11/2 2 Hot water outlet R11/2 R11/2 3 Gas valve connection Rp3/4 Rp3/4 4 Drain valve connection 3/4" 3/4" 5 T&P connection 1-11.5 NPT 1-11.5 NPT 6 Clean out 95x70 95x70 7 Condens water connection Rp1 Rp1 9 Connection coil inlet Rp1 Rp1 10 Connection coil outlet Rp1 Rp1 11 Connection electric element R11/2 R11/2 12 Connection inlet plate heat exchanger Rp1 Rp1 13 Connection outlet plate heat exchanger Rp1 Rp1 14 Connection recirculation Rp1 Rp1 On all SGE water heaters 3 years of warranty apply on the tank and 1 year warranty on all parts. Solar control SGE Installation diagrams Vented Unvented 3 Temperature and pressure valve 4 Stop valve 5 Non-return valve 6 Circulation pump 9 Drain valve 10 Gas valve 11 Service valve 12 Temperature meter 13 Condensate drain 14 Hot water tap 16 Expansion vessel 17 3-way valve 18 Water tank 19 Float valve 23 P-valve 26 Air bleed 37 Flow sensor 38 Solar pump station S1 T-collector S2 T-tank S4 T-return solar A Cold water supply B Hot water outlet C Circulation pipe D Gas supply E Water overflow F Inlet Solar Heatexchanger G Outlet Solar Heatexchanger H Overflow 1 Pressure reducing valve 3 Temperature and pressure valve 4 Stop valve 5 Non-return valve 6 Circulation pump 9 Drain valve 10 Gas valve 11 Service valve 12 Temperature meter 13 Condensate drain 14 Hot water tap 15 Expansion valve 16 Expansion vessel 23 P-valve 26 Air bleed 37 Flow sensor 38 Solar pump station S1 T-collector S2 T-tank S4 T-return solar A Cold water supply B Hot water outlet C Circulation pipe D Gas supply F Inlet Solar Heatexchanger G Outlet Solar Heatexchanger SGE Electrical diagram SGE 40-60 Components controller A Controller B Ionisation rod C Glow ignitor D Gas control E Burner earth connection F Extra ON-mode switch G Continuous pump H Program controlled pump J Extra error signal K Isolating transformer L Double-pole main switch M ON / OFF switch control N Display O Fan P Temperature sensor (T2 - bottom of tank) Q Dummy R Temperature sensor (T1 - top of tank) S Selection resistor T Pressure switch U Controller solar system (BUS-link) F1 Fuse F3 Fuse Connections main controller 1 X5 BUS-link 2 X6 - - X3 X4 L5 N N L4 X2 X1 N L2 N L3 L1 3 n.a 4 n.a 5 External ON / OFF 6 7 8 Continuous pump 9 10 11 Program controlled pump 12 13 14 Extra error signal 15 16 Isolating transformer 17 (primary side) 18 19 Isolating transformer 20 (secundary side) 21 22 23 Power supply 24 N Components solar controller AA Controller BB Pump solar system (ON / OFF) CC Pump solar system (modulating) DD Temperature sensor (S1 - solar collector) EE Temperature sensor (S2 - tank) FF Q/T-measuring (incl. temperature sensor S4 - return solar collector) GG Controller (BUS-link) F2 Fuse Connections solar controller 1 L N - - - L1 N N L2 - - - - - - - - 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 1 2 1 2 2 Power supply 3 4 n.a. 5 n.a. 6 n.a. 7 Pump solar system 8 (ON / OFF) 9 10 11 Pump solar system 12 (modulating) 13 14 n.a. 15 n.a. 16 n.a. 17 n.a. 18 n.a. 19 n.a. 20 n.a. n.a. J3 n.a. n.a. n.a. Power supply 5V Sensor return J12 solar collector (S4) Earth Flow signal n.a. J13 Sensor solar collector (S1) n.a. Sensor solar collector (S1) n.a. J14 Sensor tank (S2) n.a. Sensor tank (S2) J15 n.a. n.a. J16 BUS-link n.a. J17 n.a. 3 n.a. Flue systems SGE Installation options C13 A SGE water heater should be installed according category B23, C13, C33, C43 or C53*. Concentric 0 4 E GS 0 6 E GS B23 C53 C33 Diameter (mm) 100/150 100/150 Max. length (m) 15 15 Max. 45/90° bends 4 4 Parallel (standard diameter) Diameter (mm) 100 100 Max. length (m) 25 25 Lequivalent/bend 90° (m) 4,6 4,6 Lequivalent/bend 45º (m) 1,2 1,2 Parallel (larger diameter for more length) Diameter (mm) 130 130 Max. length (m) 100 100 Lequivalent/bend 90º (m) 2,4 2,4 Lequivalent/bend 45º (m) 1,4 1,4 * All SGE water heaters are also approved for installations where the unit is supplied without venting materials (C63). Concentric flues It is not permitted to use more than the specified number of bends, even when the duct is shorter than the maximum length. A 45° bend is equivalent to a 90° bend. Parallel flues - The maximum permissible length should be reduced by the equivalent length of each bend. (Note: for a parallel installation this means that 3 changes in direction amount to 6 bends (3 in the supply duct and 3 in the flue). - The maximum length also applies if a parallel installation has Flue systems SGE C43 different supply and flue duct lengths (B23, C53). - Combined flues (C43) shall be fitted with a condensate drain. Note: horizontal flue runs must be installed with a fall of at least 5 mm per metre. Minimum space requirements 0 0 4 6 E E G G S S Y V W X W V Y X Ø100/150 Ø100/150 Minimal space for wall duct (mm) V 550 550 W 790 790 X 2335 2335 Y 1475 1475 . e Y * 1025 1025 t i s 3 b 0 e / w E Minimal space for roof duct (mm) r G u S o / V 1500 1500 o 8 t 0 W 1035 1035 r 1 e f 1 X 3585 3585 e / r T e X ** 2520 2520 s N I a e l Y 1415 1415 e p g , y Y ** 465 465 n l p a p h a c s For the parts numbers of components and flue gas ducts, etc. n o o t i t please refer to the "Maintenance and accessories" chapter. i t d c n e o j c b * Distance without concentric pipe between bend and wall duct. d u n s ** Distance without concentric pipe between appliance and roof duct. a s a t m r a e D T www.aosmithinternational.com
Đăng ký:
Đăng Nhận xét (Atom)
Black & Decker Black&Decker Vacuum NV4820CN, homeappliance
Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...
-
Download! BCM7255CN06EFM3.qxd 8/24/06 09:44 Page 1 Digital COOL MIST Humidifier MODEL BCM7255-CN HUMIDIFIER SAFETY PLEASE READ AN...
-
Download! BEFORE AFTER MODEL TH110A-DP-P B 240 VAC B B SUMMARY 60 HZ OPTIONS SELECTION B At the back of the thermostat...
-
Download! Storage Tank Solar control SGS SGS Condensing High Efficiency Gas-Solar Water Heater SGS - 28/30/50/60/80/100 Fully...
Không có nhận xét nào:
Đăng nhận xét