Thứ Tư, 11 tháng 8, 2021

A.O. Smith ARGSS02708, homeappliance





Download!

Instruction Manual for Residential Power Vent Gas Water Heaters with Hot Surface Ignition NOT FOR USE IN MANUFACTURED (MOBILE) HOMES GAMA certification applies to all residential gas water heaters with capacities of 20 to 100 gallons with input rating of 75,000 BTU/Hr. or less. ALL TECHNICAL AND WARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COM PANY LISTED ON THE RATING PLATE ON THE WATER HEATER. For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER WARNING WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result, causing property damage, personal injury or death. –Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. –WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. –Installation and service must be performed by a qualified installer, service agency or the gas supplier. Save this Manual for Future Reference. Improper installation, adjustment, alteration, service or maintenance can cause DEATH, SERI OUS BODILY INJURY, OR PROPERTY DAM AGE. Refer to this manual for assistance or con sult the local gas utility for further information. WARNING Flammable vapors may be drawn by air cur rents from other areas of the structure to this appliance. WARNING READ THE GENERAL SAFETY SECTION BEGIN NING ON INSIDE COVER AND THEN THIS ENTIRE MANUAL BEFORE INSTALLING OR OPERATING THIS WATER HEATER. 184326-001 11-03 General Safety WARNING Improper installation, adjustment, alteration, service or main tenance can cause death, serious bodily injury, or property damage. Refer to this manual or consult your local gas utility for further assistance. WARNING At the time of manufacture this water heater was provided with a combination temperature-pressure relief valve certified by a nationally recognized testing laboratory that maintains period ic inspection of production of listed equipment or materials, as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, and the current edition of ANSI Z21.22 • CSA 4.4 and the code requirements of ASME. If replaced, the valve must meet the requirements of local codes, but not less than a combination temperature and pressure relief valve certified as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22 • CSA 4.4 by a nationally recog nized testing laboratory that maintains periodic inspection of production of listed equipment or materials. The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 lbs. p.s.i.) and a discharge capacity not less than the water heater input rate as shown on the model rating plate. (Electric heaters - watts divided by 1000 x 3412 equal BTU/Hr. rate.) Your local jurisdictional authority, while mandating the use of a temperature-pressure relief valve complying with ANSI Z21.22 • CSA 4.4 and ASME, may require a valve model dif ferent from the one furnished with the water heater. Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a locally pre scribed temperature-pressure relief valve installed in the des ignated opening in the water heater in place of the factory fur nished valve. For safe operation of the water heater, the relief valve must not be removed from it's designated opening or plugged. The temperature-pressure relief valve must be installed direct ly into the fitting of the water heater designated for the relief valve. Position the valve downward and provide tubing so that any discharge will exit only within 6 inches above, or at any distance below the structural floor. Be certain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circum stances. Excessive length, over 30 feet, or use of more than four elbows can cause restriction and reduce the discharge capaci ty of the valve. No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unless a 6″ air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage. The Discharge Pipe: —Must not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions. —Must not be plugged or blocked. —Must be of material listed for hot water distribution. —Must be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the discharge pipe. —Must terminate at an adequate drain. —Must not have any valve between the relief valve and tank. WARNING WATER HEATERS EQUIPPED FOR ONE TYPE GAS ONLY: This water heater is equipped for one type gas only. Check the model rating plate near the gas control valve for the correct gas. DO NOT USE THIS WATER HEATER WITH ANY GAS OTHER THAN THE ONE SHOWN ON THE MODEL RATING PLATE. Failure to use the correct gas can cause problems which can result in DEATH, SERI OUS BODILY INJURY, OR PROPERTY DAMAGE. If you have any questions or doubts consult your gas supplier or local utility. WARNING A fire can start if combustible materials such as clothing, cleaning materials, or flammable liquids are placed against or next to the water heater. WARNING INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS (VAPORS) ARE LIKELY TO BE PRESENT OR STORED (GARAGES, STORAGE, AND UTILITY AREAS, ETC): Flammable liquids (such as gasoline, solvents, propane (LP) or butane, etc.), all of which emit flammable vapors, may be improperly stored or used in such areas. The gas water heater ignitor or main burner can ignite such vapors. The resulting flashback and fire can cause death or serious burns to anyone in the area, as well as property damage. If installation in such areas is your only option, then the installa tion must be accomplished in a way that the ignitor and main burn er flame are elevated from the floor at least 18 inches. While this may reduce the chances of flammable vapors from a floor spill being ignited, gasoline and other flammable substances should never be stored or used in the same room or area containing a gas water heater or other open flame or spark producing appliance. NOTE: Flammable vapors may be drawn by air currents from other areas of the structure to the appliance. WARNING HOTTER WATER CAN SCALD: Water heaters are intended to pro duce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible tem perature setting that satisfies your hot water needs, some type of tempering device, such as a mixing valve, should be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores. Follow manufacturers instructions for installation of the valves. Before changing the factory setting on the thermostat, read the "Temperature Regulation" section in this manual. WARNING BEFORE OPERATING [PROPANE (L.P.) GAS WATER HEATERS]: Propane (L.P.) gas is heavier than air. Should there be a leak in the system, the gas will settle near the ground. Basements, crawl spaces, skirted areas under manufactured (mobile) homes (even when ventilated), closets and areas below ground level will serve as pockets for the accumulation of this gas. Before attempting to oper ate the water heater or turning on a nearby electrical light switch, be absolutely sure there is no accumulated gas in the area. Search for odor of gas by sniffing at ground level in the vicinity of the appli ance. If odor is detected, follow steps indicated at "For Your Safety" on the cover page of this manual then leave the premises. 2 General Safety (cont'd) WARNING This water heater must not be installed directly on carpeting. Car peting must be protected by a metal or wood panel beneath the appliance extending beyond the full width and depth of the ap pliance by at least 3 inches (76.2mm) in any direction, or if the ap pliance is installed in an alcove or closet, the entire floor must be covered by the panel. Failure to heed this warning may result in a fire hazard. WARNING A gas water heater cannot operate properly without the correct amount of air for combustion. Do not install in a confined area such as a closet, unless you provide air as shown in the "Locating The New Water Heater" section. Never obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas com pany. Failure to provide the proper amount of combustion air can result in a fire or explosion and can cause DEATH, SERIOUS BOD ILY INJURY, OR PROPERTY DAMAGE. WARNING If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken from out side these areas. Refer to the "Locating The New Water Heater" section of this manual and also the current edition of the National Fuel Gas Code, ANSI Z223.1, also referred to as NFPA 54 for specifics provided concerning air required. WARNING The power vent water heater requires its own (separate) venting system. It cannot be connected to an existing vent pipe or chim ney. It must be terminated to the outdoors. Failure to properly in stall the venting system can result in asphyxiation, a fire or explo sion and can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. WARNING No vent damper installation is compatible with this power vented water heater design. No vent damper, whether it is operated ther mally or otherwise is to be installed on this power vented water heater. Alteration of any part of the factory-furnished vent assembly could result in improper operation due to restriction of flue gases, spillage of flue gases and may cause carbon monoxide poisoning. WARNING 1. The appliance and its individual shutoff valve must be discon nected from the gas supply piping system during any pressure testing of the gas system at test pressures in excess of 1⁄2 pound per square inch (3.5kPa). 2. The appliance must be isolated from the gas supply piping sys tem by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pres sures equal or less than 1⁄2 pound per square inch (3.5kPa). WARNING Soot build-up indicates a problem that requires correction before further use. Turn "off" gas to water heater and leave "off" until re pairs are made, because failure to correct the cause of the sooting can result in a fire or explosion causing DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. WARNING The water heater with vent pipe installed must be properly vented outdoors. Never operate the water heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation, explosion or asphyxiation. WARNING Vent termination must not be within 4 feet of any items such as gas WARNING Obstructed or deteriorated vent systems may present a serious health risk or asphyxiation. WARNING Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can pro pellants, cleaning solvents, refrigerator and air conditioner refrig erants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach, and process chemicals are typical compounds which are potentially corrosive. WARNING Minimum clearances between the water heater and combustible and non-combustible construction are: 0 inches from sides, 0 inch es from back, 5 inches from front of jacket to closet door and 14 inches from top of jacket to combustible and non-combustible material. Minimum vent clearance: 0 inches. Provide 24 inches front clearance for servicing and adequate clearance between the jacket top & ceiling for servicing the flue area. WARNING HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possibility of injury under these condi tions, we recommend the hot water faucet be opened for several minutes at the kitchen sink before any electrical appliances which are connected to the hot water system are used (such as a dish washer or washing machine). If hydrogen gas is present, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near the faucet at the time it is open. WARNING INSULATING JACKETS: When installing an external water heater insulation jacket on a gas water heater: a. DO NOT cover the temperature-pressure relief valve. b. DO NOT put insulation over any part of the top of the gas water heater. c. DO NOT put insulation over the gas control valve or gas con trol valve/burner cover, or any access areas to the burner. d. DO NOT let insulation around the gas water heater to get with in 8 inches of the floor (air must get to the burner). e. DO NOT remove operating instructions, and safety related warn ing labels and materials affixed to the water heater. DO obtain new warning and instruction labels from the manufacturer for placement on the jacket directly over the existing labels. Failure to heed this will result in the possibility of a fire or explosion. WARNING Flood damage to a water heater may not be readily visible or imme diately detectible. However, over a period of time a flooded water heater will create dangerous conditions which can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Call a qual ified service technician or contractor to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced! CAUTION WATER HEATERS EVENTUALLY LEAK: Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow of water will not cause dam age to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Drain pans are available at your local hardware store. Such a drain pan must be not greater than 11⁄2 inches deep, have a mini mum length and width of at least 2 inches greater than the water heater dimensions and must be piped to an adequate drain. The pan meters, gas valves or other gas regulating equipment. 3 must not restrict combustion air flow. Table of Contents General Safety................................................................................................................................2,3 Table of Contents.........................................................................................................................4 Introduction.........................................................................................................................................5 Preparing for the New Installation..................................................................5 Typical Installation.....................................................................................................................6 Locating the New Water Heater....................................................................7-10 Facts to Consider About Location ..........................................................................................................................7 Combustion Air and Ventilation .........................................................................................................................8,9 Venting Clearances...........................................................................................................................................8,9 Combustion Air and Ventilation for Appliances Located in Unconfined Spaces.....................................................9 Combustion Air and Ventilation for Appliances Located in Confined Spaces.......................................................10 Installing the New Water Heater................................................................11-24 Water Piping .......................................................................................................................................................11 Temperature-Pressure Relief Valve ......................................................................................................................12 Filling the Water Heater ......................................................................................................................................13 Wiring............................................................................................................................................................13,14 Field Installed Wiring ..................................................................................................................................13,14 Wiring Diagram.................................................................................................................................................14 Venting ..........................................................................................................................................................15-22 Gas Piping......................................................................................................................................................22,23 Installation Checklist ...........................................................................................................................................24 Operating..........................................................................................................................................25-27 Temperature Regulation..................................................................................................28 For Your Information......................................................................................................29,30 Start Up Conditions .............................................................................................................................................29 Condensation ....................................................................................................................................................29 Smoke/Odor......................................................................................................................................................29 Thermal Expansion............................................................................................................................................29 Strange Sounds..................................................................................................................................................29 Operational Conditions ..................................................................................................................................29,30 Smelly Water................................................................................................................................................29,30 "Air" In Hot Water Faucet's...............................................................................................................................30 High Temperature Limit Switch .........................................................................................................................30 Venting Manual Reset Switch ............................................................................................................................30 Not Enough or No Hot Water............................................................................................................................30 Water Is Too Hot...............................................................................................................................................30 Periodic Maintenance....................................................................................................31-33 Venting System Inspection...................................................................................................................................31 Burner Inspection ................................................................................................................................................31 Burner Cleaning ..................................................................................................................................................31 L.P. Gas Control Valve & Burner Assembly Replacement Information .................................................................32 Housekeeping .....................................................................................................................................................32 Anode Rod Inspection .........................................................................................................................................32 Temperature-Pressure Relief Valve Operation......................................................................................................32 Draining..............................................................................................................................................................33 Drain Valve Washer Replacement.......................................................................................................................33 Service ................................................................................................................................................................33 Leakage Checkpoints............................................................................................................34 Troubleshooting.......................................................................................................................35-37 Repair Parts....................................................................................................................................38,39 4 Introduction Thank You for purchasing this water heater. Properly installed and maintained, it should give you years of trouble free service. Abbreviations Found In This Instruction Manual CSA - Canadian Standards Association ANSI - American National Standards Institute NFPA - National Fire Protection Association WARNING This gas-fired water heater is design certified by CSA INTERNATIONAL under American National Standard/CSA Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition). The installation must conform with this manual, Local Codes and with the current edition of the National Fuel Gas Code, ANSI Z223.1 / NFPA 54. This publication is available from your local government or public library, gas company, or by writing NFPA, Batterymarch Park, Quincy, MA 02269. Preparing for the New Installation 1. Read the "General Safety" section, pages 2 and 3 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE. This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings through out the manu al that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER. 2. The installation must conform with the instructions in this manual; gas company rules; and Local Codes, or in the absence of Local Codes, with the current edition of the National Fuel Gas code, ANSI Z223.1, also referred to as NFPA 54. This publication is available from your local government or public library or gas company or by writing NFPA, Batterymarch Park, Quincy, MA 02269. 3. If after reading this manual you have any questions or do not understand any portion of the instructions, call the local gas utility or the manufacturer whose name appears on the rating plate. 5 4. Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires. Examine the location to ensure the water heater com plies with the "Locating the New Water Heater" section in this manual. 5. For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation pro cedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814. 6. Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00. 7. Complies with SCAQMD rule #1121 and districts hav ing equivalent NOx requirements. Typical Installation VENT TO OUTDOORS HOT WATER OUTLET VACUUM RELIEF REQUIRED BY SOME CODES (REFER TO LOCAL CODES) COLD WATER INLET Some models are equipped with circulating loop fittings. *HOT (OUTLET) RECIRCULATING LOOP CONNECTION CAN BE INSTALLED WITHIN 360° RADIUS TEMPERATURE PRESSURE RELIEF VALVE DIRECTION OF FLOW CHECK VALVE MARKED WITH DIRECTION OF FLOW ARROW DISCHARGE PIPE TEMPERED WATER OUTLET MIXING VALVE 7' power cord (Factory supplied) GAS SUPPLY (Do not cap or plug) PROVIDE A 6″ AIR GAP BETWEEN THE END OF THE DISCHARGE PIPE AND DRAIN *COLD (RETURN) RECIRCULAT ING LOOP CONNECTION MUST BE INSTALLED ONLY IN THE UPRIGHT POSITION DIRECTION OF FLOW HEAT TRAP *Certain models do not have these connection assemblies shipped with the water heater. They (Part #9001262) are available through the manufacturer. See "Repair Parts" section for ordering information. This appliance has been design certified as complying with American National Standard/CSA Standard for water heaters and is considered suitable for: Water (Potable) Heating: All models are "considered suitable for water (potable) heating." Water (Potable) Heating and Space Heating: Certain models are "considered suitable for water (potable) heating and space heating." Refer to the model and rating plate of the water heater. WARNING When the system requires water at temperatures higher than required for other uses, the hot water system may require a means such as a mixing valve to be installed to temper the water at certain points of use. Some people are more likely to be permanently injured by hot water than others; these include the elderly, children, the infirm, or the physically/mentally handicapped. Before immersing yourself or anyone else in hot water, be sure to check the water temperature. WARNING: HOTTER WATER INCREASES THE RISK OF SCALD INJURY. (Also see "Temperature Regulation" section) Mixing valves are available at plumbing supply or hardware stores. Follow manufacturers instructions for installation of these valves. WARNING This water heater shall not be connected to any heating systems or component(s) previously used with a non potable water heating appliance. If this water heater is also used for space heating applica tions, all piping and components connected to the water heater shall be suitable for use with potable water. WARNING Toxic chemicals such as used for treatment of boilers or non-potable water heating appliances shall never be introduced into a potable water space heating system. NOTE: To protect against untimely corrosion of hot and cold water fittings, it is strongly recommended that di-electric unions or couplings be installed on this water heater when connected to copper pipe. 6 Locating the New Water Heater Facts to Consider About the Location You should carefully choose an indoor location for the new water heater, because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in manufactured (mobile) homes or outdoor installation. Whether replacing an old water heater or putting the water heater in a new location, the following critical points must be observed. 1. The location selected should be indoors as close as practical to the vent termination point, and as central ized with the water piping system as possible. The water heater, as all water heaters, will eventually leak. Do not install without adequate drainage provisions where water flow will cause damage. 2. 40,000 BTU/HR INPUT – If vented through an outside wall or through the roof, using 3″ vent piping the total vent run (vertical and horizontal) cannot exceed 115 feet with one 90˚ elbow (50 feet with one 90° elbow if optional 2″ vent piping is used). If more elbows are required the venting distance must be reduced 5 feet for every 90˚ elbow. See page 18 for vent charts. ALL OTHER INPUTS HIGHER THAN 40,000 BTU/HR – If vented through an outside wall or through the roof, using 3″ vent piping the total vent run (vertical and hor izontal) cannot exceed 70 feet with one 90˚ elbow (110 feet with one 90° elbow if optional 4″ vent piping is used). If more elbows are required the venting distance must be reduced 5 feet for every 90˚ elbow. See page 18 for vent chart. 3. Vent piping cannot slope downward and horizontal runs require 1⁄8″ per five foot rise. All horizontal runs require adequate support at 31⁄2 foot intervals and vertical runs supported at 5 foot intervals. 4. The water heater requires its own (separate) venting sys tem. It cannot be connected to an existing vent pipe or chimney. It must terminate to the outdoors. Whenever possible terminate the vent on the leeward side of the building if vented through an outside wall. Note: Condensation may be created, at times, as the com bustion gases exit the vent cap and discoloration of sur faces in proximity to the vent cap may occur. WARNING The power vent water heater requires its own (separate) vent ing system. It cannot be connected to an existing vent pipe or chimney. It must be terminated to the outdoors. Failure to properly install the venting system can result in asphyxiation, a fire or explosion and can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. 5. The water heater comes equipped with a 7 foot power cord which can be used to connect to a 110/120 volt power source if (1) local codes allow, and (2) there is a three prong receptacle available. WARNING Do not use an extension cord. If there is not a suitable receptacle and/or local codes prohibit use of a power cord, field wiring must be provided. CAUTION WATER HEATERS EVENTUALLY LEAK: Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow of water will not cause damage to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Drain pans are available at your local hardware store. Such a drain pan must be not greater than 11⁄2 inches deep, have a minimum length and width of at least 2 inches greater than the water heater dimen sions and must be piped to an adequate drain. The pan must not restrict combustion air flow. 6. The location selection must provide adequate clear ances for servicing and proper operation of the water heater. WARNING INSTALLATION IN AREAS WHERE FLAMMABLE LIQUIDS (VAPORS) ARE LIKELY TO BE PRESENT OR STORED (GARAGES, STORAGE AND UTILITY AREAS, ETC): Flammable liquids (such as gasoline, solvents, propane (LP) or butane, etc.) or other substances (such as adhesives, etc.), all of which emit flammable vapors, may be improperly stored or used in such areas. The gas water heater ignitor or main burner can ignite such vapors. The resulting flashback and fire can cause death or serious burns to anyone in the area, as well as property damage. If installation in such areas is your only option, then the installation must be accomplished in a way that the ignitor and main burner flame are elevated from the floor at least 18 inches. While this may reduce the chances of flammable vapors from a floor spill being ignited, gasoline and other flammable substances should never be stored or used in the same room or area containing a gas water heater or other open flame or spark producing appliance. Also, the water heater must be located and/or protected so it is not subject to physical damage by a moving vehicle. NOTE: Flammable vapors may be drawn by air currents from other areas of the structure to the appliance. 7 Locating the New Water Heater (cont'd) Facts to Consider About the Location (cont'd) WARNING Propellants of aerosol sprays and volatile compounds, (cleaners, chlorine based chemicals, refrigerants, etc.) in addition to being highly flammable in many cases, will also change to corrosive hydrochloric acid when exposed to the combustion products of the water heater. The results can be hazardous, and also cause product failure. WARNING This water heater must not be installed directly on carpeting. Carpeting must be protected by a metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches (76.2mm) in any direction, or if the appliance is installed in an alcove or clos et, the entire floor must be covered by the panel. Failure to heed this warning may result in a fire hazard. WARNING If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that com bustion and ventilation air be taken from outside these areas. Refer to the "Locating The New Water Heater" section of this manual and also the current edition of the National Fuel Gas Code, ANSI Z223.1, also referred to as NFPA 54 for specifics provided concerning air required. Combustion Air and Ventilation When determining the installation location for a power vent water heater, snow accumulation and drifting should be considered in areas where applicable. Venting Through an Outside Wall – Clearances • 0″ clearance for 3″ (or optional 2″ and 4″) PVC, ABS, or CPVC Schedule 40 piping from combustible surfaces. • 18″ minimum in all directions from any obstruction that may interfere. 12" MAX. 6" MIN. 0" 0" 100 Sq In Minimum MIN. MIN. • 12″ minimum from the ground, 9″ ceiling overhangs. Figure 2. WATER HEATER WATER WARNING VENTILATION • The Power Vent outlet terminal shall terminate at least 36″ 5" Minimum clearances between the water heater and com AIR MIN. 0" MIN. above any forced air inlet into the building located within 10 OPENINGS bustible and non-combustible construction are: 0 inches TOP VIEW DOOR 0" MIN. feet. Figure 3a. from sides, 0 inches from back, 5 inches from front of jack 100 Sq In Minimum OF CLOSET WITHOUT DOOR TOP VIEW OF CLOSET • The Power Vent outlet terminal shall terminate at least 4 feet et to closet door and 14 inches from top of jacket to com 6" MIN. DOOR 12" MAX. WITH DOOR bustible and non-combustible material. Minimum vent clear FRONT VIEW OF DOOR RECTANGULAR AIR 3" MIN. DUCT below, 4 feet horizontally from or 1 foot above any door, win ance: 0 inches. Provide 24 inches front clearance for ser vicing and adequate clearance between the jacket top & AIR DUCT ceiling for servicing the flue area. (See Figure 1). HEATER TOP VIEW OF ALCOVE Figure 1 WARNING A gas water heater cannot operate properly without the correct amount of air for combustion. Do not install in a confined area such a closet, unless you provide air as shown in the "Locating The New Water Heater" section. Never obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas company. Failure to provide the proper amount of combustion air can result in a fire or explosion and can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. 8 dow or gravity air inlet into the building. Figure 3a. • 18″ minimum from other natural draft (gravity) direct vent, power vent or power direct vent appliance inlet and/or outlet vent(s) when directly above or 135° to either side of center line. Standards. Figure 3c. • 24″ minimum from any appliance inlet and/or outlet vents when directly below or 45° to either side of center line. Figure 3c. • The location selection must provide clearances for servicing and proper operation of the water heater. Figure 4. • Vent termination must not be within 4 feet of any items such as gas meters, gas valves or other gas regulating equipment. • The venting system must be installed in a manner which allows inspection of the installation of the venting pipes and joints as well as periodic inspection after installation as required by ANSI WARNING Vent termination must not be within 4 feet of any items such as gas meters, gas valves or other gas regulating equipment. WARNING Failure to have required clearances between water heater and combustible material will result in a fire hazard. Locating the New Water Heater (cont'd) Must maintain adequate service and maintenance accessibility. 9″ min. from any overhang Figure 2 CLof Flue 12″ min. POWER VENT TERMINAL IF "B" DIMENSION IS LESS THAN 10' Range of degrees pipe installation. Figure 4 available for vent Venting Through Roof – Clearances • 0″ clearance for 3″ (or optional 2″ and 4″) PVC, ABS, or CPVC Schedule 40 piping from combustible surfaces. • The Power Vent outlet terminal shall terminate at least 18 inch es above the roof surface. Figure 5. • The location selection must provide clearances for servicing and proper operation of the water heater. Figure 4. • The venting system must be installed in a manner which allows inspection of the installation of the venting pipes and joints as well as periodic inspection after installation as required by ANSI Standards. 48″ min. POWER VENT 48″ min. 12″ min. B45° VENT CAP W/SCREEN90° STREET ELL 36″ min. TERMINAL Figure 3a 12″ min. GRADE VENT TERMINAL FORCED AIR INLET INTO BLDG. 18″ 18″ MIN. 18″ MIN. Figure 3b POWER VENT TERMINAL 18″ 18″ TO WALL OR OTHER OBSTRUCTIONS THAT MAY INTERFERE WITH VENTING. VENT TERMINAL CORNER OF BUILDING NATURAL DRAFT (GRAVITY), DIRECT VENT, POWER VENT OR POWER DIRECT VENT Figure 5 Combustion Air and Ventilation for Appliances Located in Unconfined Spaces Unconfined Space is a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space. APPLIANCE INLET AND/OR 24″ OUTLET VENT(S) 45° Figure 3c In unconfined spaces in buildings, infiltration may be adequate to provide air for combustion, ventilation and dilution of flue gases. However, in buildings of tight construction (for example, weather stripping, heavily insulated, caulked, vapor barrier, etc.), additional air may need to be provided using the methods described in Combustion Air and Ventilation for Appliances Located in Confined Spaces. 9 Locating the New Water Heater (cont'd) Combustion Air and Ventilation for Appliances Located in Confined Spaces Confined Space is a space whose volume is less than 50 cubic feet per 1,000 Btu per hour of the aggregate input rating of all appliances installed in that space. a. ALL AIR FROM INSIDE BUILDINGS: (See Page 8 Figure 1, and Figure 6 below) The confined space shall be provided with two permanent openings communicating directly with an additional room(s) of sufficient volume so that the combined volume of all spaces meets the criteria for an unconfined space. The total input of all gas utilization equipment installed in the combined space 2. When communicating with the outdoors through vertical ducts, each opening shall have a minimum free area of 1 square inch per 4,000 BTU per hour of total input rating of all equipment in the enclosure. (See Figure 8.) VENTILATION LOUVERS (each end of attic) VENT THROUGH ROOF shall be considered in making this determination. Each open ing shall have a minimum free area of one square inch per 1,000 BTU per hour of the total input rating of all gas utiliza tion equipment in the confined space, but not less than 100 square inches. One opening shall commence within 12 inch es of the top and one commencing within 12 inches of the bottom of the enclosure. VENT THROUGH AIR OUTLET INLET AIR DUCT (ends 1″ above floor) Figure 8 VENT TO OUTDOORS WATER HEATER ROOF VENT TO 3. When communicating with the outdoors through horizon- tal ducts, each opening shall have a minimum free area of 1 square inch per 2,000 BTU per hour of total input rating of all equipment in the enclosure. (See Figure 9.) Figure 6 OPENINGS WATER HEATER OUTDOORS OUTLET AIR DUCT INLET AIR DUCT VENT THROUGH ROOF VENT TO OUTDOORS b. ALL AIR FROM OUTDOORS: (see Figures 7-9) The confined space shall be provided with two permanent openings, one commencing within 12 inches of the top and one commencing within 12 inches from the bottom of the enclosure. The openings shall communicate directly, or by ducts, with the outdoors or spaces (crawl or attic) that freely communicate with the outdoors. VENTILATION LOUVERS (each end of attic) VENT THROUGH ROOF VENT TO OUTDOORS WATER Figure 9 4. When ducts are used, they shall be of the same cross-sec- tional area as the free area of the openings to which they connect. The minimum short side dimension of rectangular air ducts shall not be less than 3 inches. (See Figure 9.) 5. Louvers and Grilles: In calculating free area, consideration shall be given to the blocking effect of louvers, grilles or screens protecting openings. Screens used shall not be small er than 1⁄4 inch mesh. If the free area through a design of lou ver or grille is known, it should be used in calculating the size opening required to provide the free area specified. If INLET AIR DUCT Figure 7 HEATER the design and free area is not known, it may be assumed that wood louvers will be 20-25 percent free area and metal louvers and grilles will have 60-75 percent free area. Louvers and grilles shall be fixed in the open position or interlocked with the equipment so that they are opened automatically during equipment operation. VENTILATION LOUVERS 1. When directly communicating with the outdoors, each opening shall have a minimum free area of 1 square inch per 4,000 BTU per hour of total input rating of all equip ment in the enclosure. (See Figure 6.) 10 6. Special Conditions Created by Mechanical Exhausting or Fireplaces: Operation of exhaust fans, ventilation systems, clothes dryers or fireplaces may create conditions requiring special attention to avoid unsatisfactory operation of installed gas utilization equipment. Installing the New Water Heater Water Piping WARNING HOTTER WATER CAN SCALD: Water heaters are intend ed to produce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be per manently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, some type of temper ing device, such as a mixing valve, should be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores. Follow manufacturers instructions for installation of the valves. Before changing the factory set ting on the thermostat, read the "Temperature Regulation" section in this manual. This water heater shall not be connected to any heating systems or component(s) used with a non-potable water heating appliance. If a water heater is installed in a closed water supply sys tem; such as one having a back-flow preventer, check valve, water meter with a check valve, etc... in the cold water supply; means shall be provided to control thermal expansion. Contact the water supplier or plumbing con tractor on how to control this situation. NOTE: To protect against untimely corrosion of hot and cold water fittings, it is strongly recommended that dielec tric unions or couplings be installed on this water heater when connected to copper pipe. The illustration shows the attachment of the water piping to the water heater. The water heater is equipped with 3/4 inch water connections for 40 and 50 gallon models and 1 inch water connections for 75 gallon models. NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the cold water inlet con nection. Do not solder the cold water supply line directly to the cold water inlet or it will harm the dip tube. NOTE: This water heater is insulated to minimize heat loss from the tank. Further reduction in heat loss can be accomplished by insulating the hot water lines from the water heater. VENT TO OUTDOORS HOT OUTLET TO HOUSE DISCHARGE PIPE (Do not cap or plug) PROVIDE A 6″ AIR GAP BETWEEN THE END OF THE DISCHARGE PIPE AND DRAIN 11 SHUTOFF VALVE GAS SUPPLY COLD INLET WATER LINE TEMPERATURE PRESSURE RELIEF VALVE Installing the New Water Heater (cont'd) Temperature-Pressure Relief Valve WARNING At the time of manufacture this water heater was provided with a combination temperature-pressure relief valve certi fied by a nationally recognized testing laboratory that main tains periodic inspection of production of listed equipment or materials, as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, and the current edition of ANSI Z21.22 • CSA 4.4 and the code requirements of ASME. If replaced, the valve must meet the requirements of local codes, but not less than a combination temperature and pressure relief valve certi fied as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22 • CSA 4.4 by a nationally recognized testing laboratory that maintains periodic inspection of pro duction of listed equipment or materials. The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 lbs./sq. in.) and a discharge capacity not less than the water heater input rate as shown on the model rating plate. (Electric heaters - watts divided by 1000 x 3412) equal BTU/Hr. rate. Your local jurisdictional authority, while mandating the use of a temperature-pressure relief valve complying with ANSI Z21.22 • CSA 4.4 and ASME, may require a valve model dif ferent from the one furnished with the water heater. Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a local ly prescribed temperature-pressure relief valve installed in the designated opening in the water heater in place of the factory furnished valve. For safe operation of the water heater, the relief valve must not be removed from it's designated opening or plugged. The temperature-pressure relief valve must be installed directly into the fitting of the water heater designated for the relief valve. Position the valve downward and provide tubing so that any discharge will exit only within 6 inches If after manually operating the valve, it fails to com pletely reset and continues to release water, immedi ately close the cold water inlet to the water heater, fol low the draining instructions, and replace the tempera ture-pressure relief valve with a new one. WARNING The temperature-pressure relief valve must be manually operated at least once a year. Caution should be taken to ensure that (1) no one is in front of or around the out let of the temperature-pressure relief valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot. COLD TEMPERATURE-PRESSURE RELIEF VALVE OPENING RELIEF VALVE ATURE-PRESSURE RELIEF VALVE. FOR SAFE OPERATION OF THE WATER HEATER, THE RELIEF VALVE(S) MUST NOT BE REMOVED FROM ITS DESIGNATED POINT OF INSTALLATION OR PLUGGED." HOT YOUR LOCAL JURISDICTIONAL AUTHORITY, WHILE MANDATING THE USE OF A TEMPERATURE-PRESSURE RELIEF VALVE COMPLYING DISCHARGE PIPE (Do not cap or plug) FERENT FROM THE ONE FURNISHED WITH THE WATER HEATER. PROVIDE A 6″ AIR GAP BETWEEN THE FIED BY THE INSTALLER OR END USER OF THE WATER HEATER END OF THE WITH A LOCALLY PRESCRIBED TEMPERATURE-PRESSURE RELIEF DISCHARGE PIPE VALVE INSTALLED IN THE DESIGNATED OPENING IN THE WATER above, or at any distance below the structural floor. Be cer HEATER. AND DRAIN tain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 30 feet, or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve. No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unless a 6″ air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage. The discharge pipe: —Must not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restriction. —Must not be plugged or blocked. —Must be of material listed for hot water distribution. —Must be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the discharge pipe. —Must terminate at an adequate drain. —Must not have any valve between the relief valve and tank. SEE MANUAL HEADING—"TEMPERATURE-PRESSURE RELIEF VALVES" FOR INSTALLATION AND MAINTENANCE OF RELIEF VALVE, "THIS WATER HEATER IS PROVIDED WITH A COMBINATION TEMPER WITH ANSI Z21.22 AND ASME, MAY REQUIRE A VALVE MODEL DIF COMPLIANCE WITH SUCH LOCAL REQUIREMENTS MUST BE SATIS DISCHARGE LINE AND OTHER SAFETY PRECAUTIONS. 12 Installing the New Water Heater (cont'd) Filling the Water Heater CAUTION Never use this water heater unless it is completely filled with water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning "ON" gas to the water heater. To fill the water heater with water: 1. Close the water heater drain valve by turning the han- dle to the right (clockwise). The drain valve is on the lower front of the water heater. 2. Open the cold water supply valve to the water heater. NOTE: The cold water supply valve must be left open when the water heater is in use. 3. To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the water heater and the piping. 4. Check all new water piping for leaks. Repair as needed. Wiring The water heater comes equipped with a 7 foot power cord which can be used to connect to a 110/120 volt power source if, (1) local codes allow, and (2) there is a three prong grounded receptacle available. This unit must have a grounded outlet to operate. 7' MAXIMUM CORD LENGTH (Factory supplied) You must provide all wiring, (1) to a receptacle or, (2) between the water heater and junction box when the power cord is not used. WARNING Do not use an extension cord. If there is not a suitable receptacle and/or local codes prohibit use of a power cord, field wiring must be provided. You must provide all wiring of the proper size outside of the water heater. You must obey local codes and electric company requirements when you install this wiring. If you are not familiar with electric codes and practices, or if you have any doubt in your ability to connect the wiring to this water heater, obtain the service of a competent elec trician. Contact a local electrical contractor and/or the local electric utility. WARNING WATER HEATERS EQUIPPED FOR ONE TYPE VOLTAGE ONLY: This water heater is equipped for 110/120 volts only. DO NOT USE THIS WATER HEATER WITH ANY VOLTAGE OTHER THAN THE ONE SHOWN ABOVE. Failure to use the correct voltage can cause problems which can result in DEATH, SERIOUS BODILY INJURY OR PROPERTY DAMAGE. If you have any questions or doubts consult your electric company. CAUTION If wiring from the fuse box or circuit breaker box was alu minum for the old water heater, replace it with copper wire. If you wish to reuse the existing aluminum wire, have the connection at the water heater made by a competent electrician. Contact a local electrical contractor and/or the local electric utility. OPTIONAL Field Installed Wiring 1. Provide a way to easily shut off the electric power when working on the water heater. This could be with a cir cuit breaker or fuse block in the entrance box or a sepa rate disconnect switch. 2. Install and connect a circuit directly from the main fuse or circuit breaker box. This circuit must be the right size and have its own fuse or circuit breaker. 3. A standard 1⁄2″ conduit opening has been made in the water heater junction box for the conduit connection. 4. Use wire nuts and connect the power supply wiring to the wires inside the water heaters junction box. 13 Installing the New Water Heater (cont'd) Wiring (cont'd) OPTIONAL Field Installed Wiring (cont'd) 5. The water heater must be electrically "grounded" by the installer. A green ground screw has been provided on the water heaters junction box. Connect ground wire to this location. For complete grounding details and all allowable exceptions, refer to local codes or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 (current edition). 6. Replace the wiring junction cover using the screw provided. WIRING DIAGRAM CAUTION Label all wires prior to disconnection when servicing con trols. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. WIRE NUTS CONDUIT GREEN GROUND SCREW 14 Installing the New Water Heater (cont'd) Venting WARNING WARNING To insure proper venting of this gas-fired water heater, the correct vent pipe diameter must be utilized. Do not install any other gas appliances on the same vent with this water heater as this will adversely affect the operation of the water heater. The combustion and ventilation air flow must not be obstructed. WARNING The water heater outlet must be connected to a vent which terminates to the outdoors. Never operate the water heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper opera tion, explosion or asphyxiation. WARNING Obstructed or deteriorated vent systems may present serious health risk or asphyxiation. WARNING The vent pipe from the water heater must slope upward 1⁄8 inch per five linear feet for any horizontal run. All vent gases must be completely vented to the outdoors of the structure (dwelling). Min. rise 1⁄8″ per five feet WARNING Failure to have required clearances between water heater and combustible material will result in a fire hazard. Be sure vent pipe is properly connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation. WARNING Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chem ical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive. 31⁄2' STRAPPING Horizontal runs must be securely supported at 31⁄2 foot intervals and vertical runs supported at 5 foot intervals. VENTING THROUGH AN OUTSIDE WALL 75 GALLON 70,000 and 75,000 BTU/HR, 50 GALLON 52,500, 55,000 and 62,500 BTU/HR, 40 GALLON 50,000 BTU/HR MODELS ONLY (See rating plate for BTU/HR rating) 3″ PVC, ABS or CPVC Schedule 40 vent piping: 1. A 3″ PVC Schedule 40-45° vent cap with wire screen is supplied with the water heater. 2. A 3″ PVC, ABS or CPVC Schedule 40-90° street ell; used to connect the vent pipe to the water heater when the vent pipe is to be turned horizontally directly off the blower (supplied locally). 3. 3″ PVC, ABS or CPVC Schedule 40 pipe (must be sup- plied locally). 3″ PVC, ABS OR CPVC SCHEDULE 40 90° STREET ELBOW 3″ PVC, ABS OR CPVC SCHEDULE 40 PIPE VENT CAP WITH SCREEN 15 Installing the New Water Heater (cont'd) Venting (cont'd) VENTING THROUGH AN OUTSIDE WALL (cont'd) 75 GALLON 70,000 and 75,000 BTU/HR, 50 GALLON 52,500, 55,000 and 62,500 BTU/HR, 40 GALLON 50,000 BTU/HR MODELS ONLY 4. The water heater requires its own (separate) venting system. 5. 3″ PVC, ABS, or CPVC Schedule 40 piping and fittings are acceptable materials for the vent system on all 75 gallon 70,000 and 75,000 BTU/HR, 50 gallon 52,500, 55,000 and 62,500 BTU/HR models, 40 gallon 50,000 BTU/HR models. 6. It cannot be connected to existing vent piping or chimney. 7. It must terminate horizontally to the outdoors. 75 GALLON 70,000 and 75,000 BTU/HR, 50 GALLON 52,500, 55,000 and 62,500 BTU/HR, 40 GALLON 50,000 BTU/HR MODELS ONLY — OPTIONAL 4″ VENT PIPING 4″ PVC, ABS or CPVC Schedule 40 vent piping: 1. A wire screen to fit a 4″ PVC, ABS or CPVC Schedule 40-45° vent cap is supplied with the water heater. 2. A 4″ PVC, ABS or CPVC Schedule 40-45° vent cap (elbow) (must be supplied locally). 3. A 3″ PVC, ABS or CPVC Schedule 40 pipe, minimum length of 3″ (must be supplied locally), to make vent connection at the blower outlet. 4. A 4″ to 3″ PVC, ABS or CPVC Schedule 40 reducer (must be supplied locally). 5. A 4″ PVC, ABS or CPVC Schedule 40-90° street ell; used to connect the vent pipe to the reducer when the vent pipe is to be turned horizontally off the blower (supplied locally). 6. 4″ PVC, ABS or CPVC Schedule 40 pipe (must be sup plied locally). 4″ PVC, ABS OR CPVC 7. The water heater requires its own (separate) venting system. 8. 4″ and 3″ PVC, ABS, or CPVC Schedule 40 piping and fittings are acceptable materials for the vent system on all 75 gallon 70,000 and 75,000 BTU/HR, 50 gallon 52,500, 55,000 and 62,500 BTU/HR models, 40 gallon 50,000 BTU/HR models. 9. It cannot be connected to existing vent piping or chimney. 10.It must terminate horizontally to the outdoors. ALL 40 AND 50 GALLON 40,000 BTU/HR MODELS ONLY 3″ PVC, ABS or CPVC Schedule 40 vent piping: 1. A 3″ PVC Schedule 40-45° vent cap with wire screen is supplied with the water heater. 2. A 3″ PVC, ABS or CPVC Schedule 40-90° street ell; used to connect the vent pipe to the water heater when the vent pipe is to be turned horizontally directly off the blower (supplied locally). 3. 3″ PVC, ABS or CPVC Schedule 40 pipe (must be sup plied locally). 3″ PVC, ABS OR CPVC SCHEDULE 40 90° STREET ELBOW3″ PVC, ABS OR CPVC SCHEDULE 40 PIPE VENT CAP WITH SCREEN 4. The water heater requires its own (separate) venting system. 5. 3″ PVC, ABS, or CPVC Schedule 40 piping and fittings are acceptable materials for the vent system on all 40 and 50 gallon 40,000 BTU/HR models. 6. It cannot be connected to existing vent piping or 4″ PVC, ABS OR CPVC SCHEDULE 40 90° STREET ELBOW SCHEDULE 40 PIPE 4″ TO 3″ PVC, ABS OR CPVC REDUCER 3″ PVC, ABS OR CPVC SCHEDULE 40 PIPE (MINIMUM LENGTH 3″) 4″ VENT CAP WITH SCREEN 16 chimney. 7. It must terminate horizontally to the outdoors. ALL 40 AND 50 GALLON 40,000 BTU/HR MODELS — OPTIONAL 2″ VENT PIPING 2″ PVC, ABS or CPVC Schedule 40 vent piping: 1. A wire screen to fit a 2″ PVC, ABS or CPVC Schedule 40-45° vent cap is supplied with the water heater. 2. A 2″ PVC, ABS or CPVC Schedule 40-45° vent cap (elbow) (must be supplied locally). Installing the New Water Heater (cont'd) 3. A 3″ PVC, ABS or CPVC Schedule 40 pipe, minimum length of 3″ (must be supplied locally), to make vent connection at the blower outlet. 4. A 3″ to 2″ PVC, ABS or CPVC Schedule 40 reducer (must be supplied locally). 5. A 2″ PVC, ABS or CPVC Schedule 40-90° street ell; used to connect the vent pipe to the reducer when the vent pipe is to be turned horizontally off the blower (supplied locally). 6. 2″ PVC, ABS or CPVC Schedule 40 pipe (must be sup- plied locally). 2″ PVC, ABS OR CPVC The vent piping may be installed as follows: 3 ELBOW EXAMPLE MIN. RISE 1⁄8″ PER FIVE FEET 3 ELBOW EXAMPLE 2″ PVC, ABS OR CPVC SCHEDULE 40 90° STREET ELBOW SCHEDULE 40 PIPE 3″ TO 2″ PVC, ABS OR CPVC REDUCER 3″ PVC, ABS OR CPVC SCHEDULE 40 PIPE (MINIMUM LENGTH 3″) VENT CAP AND SCREEN MIN. RISE 1⁄8″ PER FIVE FEET MIN. RISE 1⁄8″ PER FIVE FEET 7. The water heater requires its own (separate) venting system. 8. 2″ and 3″ PVC, ABS, or CPVC Schedule 40 piping and fittings are acceptable materials for the vent system on all 40 and 50 gallon 40,000 BTU/HR models. 9. It cannot be connected to existing vent piping or chimney. 10.It must terminate horizontally to the outdoors. NOTE: See pages 21 and 22 for vertical venting through a roof. VENTING SYSTEM EXAMPLE INSTALLATIONS FOR ALL MODELS The vent piping cannot under any circumstances be run downhill. 3 ELBOW EXAMPLE MIN. RISE 1⁄8″ PER FIVE FEET MIN. RISE 1⁄8″ PER FIVE FEET 1. Horizontal runs require a minimum 1⁄8″ rise per five feet. 40 AND 50 GALLON MODELS 50,000 BTU/HR AND HIGHER, 75 GALLON MODELS (3″ VENT) SEE CHART ON PAGE 18 FOR MAX. LENGTH 16″ MIN. 131⁄2″ MIN. 12″ MIN. MIN. RISE 1⁄8″ PER FIVE FEET 17 Installing the New Water Heater (cont'd) Venting (cont'd) VENTING THROUGH AN OUTSIDE WALL (cont'd) 40 AND 50 GALLON 40,000 BTU/HR MODELS (3″ VENT) SEE CHART BELOW FOR MAX. LENGTH 4′ MIN. ALL 40 and 50 GALLON 40,000 BTU/HR MODELS — OPTIONAL 2″ VENT PIPING 2″ DIA. VENT NUMBER OF MAX. LENGTH (FT.) 90° ELBOWS* 50 1 45 2 40 3 35 4 151⁄2″ MIN. 14″ MIN. MIN. RISE 1⁄8″ PER FIVE FEET 30 5 25 6 *NOTE: Two 45° elbows are equivalent to one 90° elbow. One 90° elbow equals 5 feet of equivalent vent length. 2. The total vertical and horizontal vent run cannot exceed the maximum length with the number of 90° elbows as specified in the tables below. If more elbows are required the venting distance must be reduced 5 feet for every 90˚ elbow: 75 GALLON 70,000 and 75,000 BTU/HR, 50 GALLON 52,500, 55,000 and 62,500 BTU/HR and 40 GALLON 50,000 BTU/HR MODELS ONLY 3″ DIA. VENT NUMBER OF MAX. LENGTH (FT.) 90° ELBOWS* 70 1 65 2 60 3 20' (EXAMPLE) 95' MAX. ONE ELBOW EXAMPLE 3″ VENT PIPE MIN. RISE 1⁄8″ PER FIVE FEET 40 GALLON 40,000 BTU/HR MODEL EXAMPLE 55 4 50 5 45 6 75 GALLON 70,000 and 75,000 BTU/HR, 50 GALLON 52,500, 55,000 and 62,500 BTU/HR and 40 GALLON 50,000 BTU/HR MODELS ONLY – OPTIONAL 4″ VENT PIPING 4″ DIA. VENT NUMBER OF MAX. LENGTH (FT.) 90° ELBOWS* 110 1 105 2 100 3 95 4 90 5 85 6 ALL 40 and 50 GALLON 40,000 BTU/HR MODELS ONLY 3″ DIA. VENT NUMBER OF MAX. LENGTH (FT.) 90° ELBOWS* 115 1 110 2 105 3 100 4 95 5 90 6 18 3. Minimum vent length for all 40,000 BTU/HR input models is 4 feet and 16 inches for all other models. VENTING THROUGH AN OUTSIDE WALL WITH LOW GROUND CLEARANCE 1. When the vent piping cannot pass through an outside wall at a height greater than or equal to 12″ above the ground (or above snow accumulation level), then the installation can be modified as shown below. 12″ MIN. ABOVE GROUND OR SNOW ACCUMULATION LEVEL Installing the New Water Heater (cont'd) 2. Refer to the tables below for maximum vent lengths for low ground clearance installations. All installations assume the use of two additional 90° elbows and the standard 45° vent cap with screen outside of the exteri or wall. 75 GALLON 70,000 and 75,000 BTU/HR, 50 GALLON 52,500, 55,000 and 62,500 BTU/HR and 40 GALLON 50,000 BTU/HR MODELS ONLY 3″ DIA. VENT NUMBER OF MAX. LENGTH (FT.) 90° ELBOWS* (inside bldg.) 60 1 55 2 50 3 45 4 40 5 35 6 75 GALLON 70,000 and 75,000 BTU/HR, 50 GALLON 52,500, 55,000 and 62,500 BTU/HR and 40 GALLON 50,000 BTU/HR MODELS ONLY – OPTIONAL 4″ VENT PIPING 4″ DIA. VENT NUMBER OF MAX. LENGTH (FT.) 90° ELBOWS* (inside bldg.) 100 1 95 2 90 3 85 4 80 5 75 6 ALL 40 and 50 GALLON 40,000 BTU/HR MODELS ONLY 3″ DIA. VENT NUMBER OF MAX. LENGTH (FT.) 90° ELBOWS* (inside bldg.) 105 1 100 2 95 3 90 4 85 5 80 6 ALL 40 and 50 GALLON 40,000 BTU/HR MODELS — OPTIONAL 2″ VENT PIPING 2″ DIA. VENT NUMBER OF MAX. LENGTH (FT.) 90° ELBOWS* (inside bldg.) 40 1 35 2 30 3 25 4 20 5 15 6 *NOTE: Two 45° elbows are equivalent to one 90° elbow. One 90° elbow equals 5 feet of equivalent vent length. 19 Cementing PVC, ABS or CPVC Pipe and Fittings Read and observe all safety information printed on primer, cleaner, and cement containers. DANGER Primer, cleaner, and cements are extremely flammable. They are harmful or fatal if swallowed. The vapors are harmful. They may irritate eyes and skin and can be absorbed through the skin. PRECAUTIONS Always store primers, cleaner, and cements in cool, dry, well ventilated places. Do not store them near heat, sparks, or flames. Keep containers closed. Use them in well ventilated areas. Wear impervious clothing while handling. Do not smoke, eat, or drink while handling. Wash thoroughly after handling and before eating. Wear eye protection when handling. If swallowed, drink water, do not induce vomiting, and call a physician or poison control center immediately. If inhaled, get fresh air and seek medical attention if ill feelings persist. In case of eye and skin contact, immediately flush with plenty of water for 15 minutes and seek medical attention if irritation persists. KEEP OUT OF REACH OF CHILDREN. All primers, cleaners, and cements must meet all local codes and applicable standards of the American Society For Testing Materials Standards. Before using primers, cleaners, and cements, stir or shake, making sure contents are liquid. Do not use if found to be lumpy or jelly-like. 1. Cut pipe ends squarely removing all burrs and dirt. 2. Dry fit pipe and fittings to be connected for proper fit. 3. Clean pipe and fitting with a primer/cleaner. 4. Apply a thin coat of cement to fitting, avoiding puddling inside. 5. Apply a liberal coat of cement to pipe leaving no voids. 6. QUICKLY assemble parts while cement is fluid! If you wait too long, re-coat pipes. 7. Push pipe completely into socket of fitting, turning as it goes until it bottoms. 8. Hold pipe and fitting together for 30 seconds. Then care fully clean off excess with a cloth. Allow connections a sufficient time to cure before disturbing. 9. Remember that vent pipes must be adequately and securely supported. APPROXIMATE SETTING TIME FOR 21⁄2″ TO 4″ PIPE JOINTS MOVEMENT COMPLETE OF JOINT SET 90°F to 150°F 3⁄4 hr. 8 hrs. 50°F to 90°F 1 hr. 15 hrs. 0°F to 50°F 11⁄3 hr. 18 hrs. Installing the New Water Heater (cont'd) Venting (cont'd) CUTTING OPENING THROUGH AN OUTSIDE WALL AND COLLAR INSTALLATION After reading the manual and you have determined the location of the opening in the wall, (using the drawing below), cut a 21⁄2″ hole for 2″ vent piping, 31⁄2″ hole for 3″ vent piping or a 41⁄2″ hole for 4″ vent piping hole through an exterior wall. NOTE: When determining location of the opening in the outside wall allow for the 1⁄8″ rise per five feet that has taken place in the horizontal run. INSTALLATION SHOWING USE OF PVC, ABS OR CPVC PIPE EXTERIOR WALL SILICONE SEALER 11⁄2″ MIN. EXTENSION THROUGH EXTERIOR WALL CL OF FLUE 14″ MIN. 40,000 BTU/HR 12″ MIN. ALL OTHER MODELS MIN. RISE 1⁄8″ PER FIVE FEET SCREW SCREW COLLAR SILICONE SEALER SCREW SCREW COLLAR SCREEN VENT CAP MUST BE POSITIONED DOWNWARD 40 GAL.– 60″ 50 GAL.– 591⁄2″ 75 GAL.– 63″ The 3″ (or optional 2″ and 4″) PVC, ABS or CPVC Schedule 40 vent pipe can be run from the water heater through the wall or from the wall to the water heater, whichever is most con venient. The vent pipe must extend a minimum of 11⁄2″ through the exterior wall. Extending the vent cap as far as possible from the surface of the exterior wall will help minimize discol oration of the wall in this area which may be caused by the flue gases. Note that the inside collar must be slipped over the vent piping before locating the pipe through the wall. Before securing the inside and outside collars to the wall, use a silicone sealer between pipe and opening to insure a water and air tight seal. 20 CONNECTING VENT TO BLOWER 1. If making an immediate horizontal run of vent off the blower, a 3″ PVC, ABS or CPVC Schedule 40 elbow (supplied locally) is required. Place the elbow in the required direction on the blower and using 3 sheet metal screws, attach the elbow. SEAL WITH RTV SEALANT 2. If there is to be a vertical run of vent from the blower, the 3″ PVC, ABS or CPVC pipe must be attached to the blow- er using 3 sheet metal screws. SEAL WITH RTV SEALANT 3. If the optional 2″ vent piping is to be used (40,000 BTU/Hr. models only), the 2″ street elbow, 3″ to 2″ reduc er and 3″ (minimum) section of 3″ PVC, ABS or CPVC pipe must be supplied locally. The 3″ (minimum) section of 3″ PVC, ABS or CPVC pipe must be attached to the blower using 3 sheet metal screws. Installing the New Water Heater (cont'd) 4. If the optional 4″ vent piping is to be used (50,000 BTU/Hr. and higher models only), the 4″ street elbow, 4″ to 3″ reducer and 3″ (minimum) section of 3″ PVC, ABS or CPVC pipe must be supplied locally. The 3″ (mini mum) section of 3″ PVC, ABS or CPVC pipe must be attached to the blower using 3 sheet metal screws. VENTING THROUGH A ROOF ALL MODELS 3″ PVC, ABS or CPVC Schedule 40 vent piping: 1. A 3″ PVC Schedule 40-45° vent cap with wire screen is supplied with the water heater. 2. 3″ PVC, ABS, or CPVC Schedule 40 piping and fittings are acceptable materials for the vent system on all mod els and must be supplied locally. 75 GALLON 70,000 and 75,000 BTU/HR, 50 GALLON 52,500, 55,000 and 62,500 BTU/HR, 40 GALLON 50,000 BTU/HR MODELS ONLY — OPTIONAL 4″ VENT PIPING 4″ PVC, ABS or CPVC Schedule 40 vent piping: 1. A wire screen to fit a 4″ PVC, ABS or CPVC Schedule 40-45° vent cap is supplied with the water heater. 2. A 3″ PVC, ABS or CPVC Schedule 40 pipe, minimum length of 3″ (must be supplied locally), to make vent connection at the blower outlet. 3. A 4″ to 3″ PVC, ABS or CPVC Schedule 40 reducer (must be supplied locally). 4. 4″ and 3″ PVC, ABS, or CPVC Schedule 40 piping and fittings are acceptable materials for the vent system on all 75 gallon 70,000 and 75,000 BTU/HR , 50 gallon 52,500, 55,000 and 62,500 BTU/HR, 40 gallon 50,000 BTU/HR models and must be supplied locally. 4″ PVC, ABS OR CPVC SCHEDULE 40 PIPE 4″ TO 3″ PVC, ABS OR CPVC REDUCER 3″ PVC, ABS OR CPVC SCHEDULE 40 PIPE (MINIMUM LENGTH 3″) ALL 40 AND 50 GALLON 40,000 BTU/HR MODELS — OPTIONAL 2″ VENT PIPING 2″ PVC, ABS or CPVC Schedule 40 vent piping: 1. A wire screen to fit a 2″ PVC, ABS or CPVC Schedule 40-45° vent cap is supplied with the water heater. 2. A 3″ PVC, ABS or CPVC Schedule 40 pipe, minimum length of 3″ (must be supplied locally), to make vent connection at the blower outlet. 3. A 3″ to 2″ PVC, ABS or CPVC Schedule 40 reducer (must be supplied locally). 4. 2″ and 3″ PVC, ABS, or CPVC Schedule 40 piping and fittings are acceptable materials for the vent system on all 40 and 50 gallon 40,000 BTU/HR models and must be supplied locally. 2″ PVC, ABS OR CPVC SCHEDULE 40 PIPE 3″ TO 2″ PVC, ABS OR CPVC REDUCER 3″ PVC, ABS OR CPVC SCHEDULE 40 PIPE (MINIMUM LENGTH 3″) 1. The water heater requires its own (separate) venting system. 2. It cannot be connected to existing vent piping or chimney. 3. It must terminate vertically to the outdoors. 4. Typical installation(s) shown on page 22. 5. Refer to "Cementing PVC, ABS or CPVC Pipe and Fittings" on page 19 and "Connecting Vent to Blower" on pages 20 and 21. 21 Installing the New Water Heater (cont'd) VENTING THROUGH A ROOF (cont'd) 90˚ STREET 75 GALLON 70,000 and 75,000 BTU/HR, 50 GALLON 52,500, 55,000 and 62,500 BTU/HR and 40 GALLON 50,000 BTU/HR MODELS ONLY – OPTIONAL 4″ VENT PIPING 4″ DIA. VENT NUMBER OF 45˚ VENT CAP SCREEN VENT CAP MUST ELL SEAL AROUND FLASHING MAX. LENGTH (FT.) 90° ELBOWS* 110 1 105 2 100 3 BE POSITIONED DOWNWARD 18″ MIN. EACH VENT MAINTAIN LISTED CLEARANCE SUPPORT LATERALS MAINTAIN LISTED CLEARANCE 45° ELBOW 95 4 90 5 85 6 ALL 40 and 50 GALLON 40,000 BTU/HR MODELS ONLY 3″ DIA. VENT NUMBER OF MAX. LENGTH (FT.) 90° ELBOWS* 115 1 SUPPORT IF NECESSARY MAINTAIN LISTED CLEARANCE CERTIFIED WATER HEATER MIN. EVERY 31/2' POSITION FIRESTOP EXHAUST VERTICAL VENT TOTAL VERTICAL AND HORIZONTAL RUNS - SEE ITEM 6. 110 2 105 3 100 4 95 5 90 6 ALL 40 and 50 GALLON 40,000 BTU/HR MODELS — OPTIONAL 2″ VENT PIPING 2″ DIA. VENT NUMBER OF MAX. LENGTH (FT.) 90° ELBOWS* 50 1 45 2 40 3 35 4 30 5 25 6 *NOTE: Two 45° elbows are equivalent to one 90° elbow. One 90° elbow equals 5 feet of equivalent vent length. 6. The total vertical and horizontal vent run cannot exceed the maximum length with the number of 90˚ elbows as specified in the tables below and in the next column. If more elbows are required the venting dis tance must be reduced 5 feet for every 90˚ elbow. Gas Piping WARNING 75 GALLON 70,000 and 75,000 BTU/HR, 50 GALLON 52,500, 55,000 and 62,500 BTU/HR and 40 GALLON 50,000 BTU/HR MODELS ONLY 3″ DIA. VENT NUMBER OF MAX. LENGTH (FT.) 90° ELBOWS* 70 1 65 2 60 3 55 4 50 5 45 6 Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 10.5 in. water column (2.6kPa) for natural gas or 13 in. water column (3.2kPa) for propane (L.P.) gas. The mini mum inlet gas pressure listed on the rating plate is for the purpose of input adjustment. WARNING If the gas control valve is subjected to pressure exceeding 1/2 pound per square inch (3.5kPa), the damage to the gas con trol valve could result in a fire or explosion from leaking gas. WARNING If the main gas line shutoff serving all gas appliances is used, also turn "OFF" the gas at each appliance. Leave all gas appliances turned "OFF" until the water heater instal lation is complete. 22 Installing the New Water Heater (cont'd) A gas line of sufficient size must be run to the water heater. Consult the current edition of National Fuel Gas Code ANSI Z223.1, also referred to as NFPA 54 and the gas company concerning pipe size. There must be: — A readily accessible manual shut off valve in the gas supply line serving the water heater, and — A drip leg (sediment trap) ahead of the gas control valve to help prevent dirt and foreign materials from entering the gas control valve. — A flexible gas connector or a ground joint union between the shutoff valve and control valve to permit servicing of the unit. Be sure to check all the gas piping for leaks before lighting the water heater. Use a soapy water solution, not a match or open flame. Rinse off soapy solution and wipe dry. When installed at elevations above 2,000 feet, input ratings should be reduced at the rate of 4 percent for each 1,000 feet above sea level. Installations above 4,000 ft. require replace ment of the burner orifice in accordance with the National Fuel Gas Code ANSI Z223.1 / NFPA 54. WARNING Failure to replace the orifice could result in improper and inefficient operation of the appliance, producing carbon monoxide gas in excess of safe limits, which could result in serious injury or death. Contact your gas supplier for any specific changes which may be required in your area. WARNING Contaminant's in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion. Before attaching the gas line be sure that all gas pipe is clean on the inside. To trap any dirt or foreign material in the gas supply line, a drip leg (some times called a sediment trap) must be incorporated in the piping. The drip leg must be readily accessible. Install in accordance with the "Gas Piping" section. Refer to the current edition of the National Fuel Gas Code, ANSI Z223.1, also referred to as NFPA 54. GAS PIPING WITH FLEXIBLE CONNECTOR GAS SUPPLY PIPING MANUAL SHUTOFF VALVE FLEXIBLE GAS CONNECTOR LABELED AS COMPLYING WITH ANSI STANDARDS GROUND JOINT UNION (OPTIONAL) WARNING The appliance and its individual shutoff valve must be dis connected from the gas supply piping system during any pres sure testing of that system at test pressures in excess of 1/2 pound per square inch (3.5kPa). The appliance must be isolated from the gas supply piping sys tem by closing its individual manual shutoff valve during any 3″ MIN. DRIP LEG (SEDIMENT TRAP) CAP GAS CONTROL VALVE pressure testing of the gas supply piping system at test pres sures equal to or less than 1/2 pound per square inch (3.5kPa). WARNING The appliance and its gas connection must be leak tested before placing the appliance in operation. WARNING Use pipe joint compound or teflon tape marked as being resis tant to the action of petroleum [Propane (L.P.)] gases. SEDIMENT TRAP A sediment trap shall be installed as close to the inlet of the water heater as practical at the time or water heater instal lation. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recog nized as an effective sediment trap. If a tee fitting is used, it shall be installed in conformance with one of the methods GAS PIPING WITH ALL BLACK IRON PIPE TO GAS CONTROL GAS SUPPLY PIPING MANUAL SHUTOFF VALVE GROUND JOINT UNION BLACK PIPE of installation shown. Connecting the gas piping to the gas control valve of the water heater can be accomplished by either of the two methods shown. 3″ MIN. DRIP LEG (SEDIMENT TRAP) CAP GAS CONTROL VALVE 23 Installing the New Water Heater (cont'd) Installation Checklist BEFORE OPERATING THE HEATER: 1. Check the gas line for leaks. a. Use a soapy water solution. DO NOT test for gas leaks using a match or open flame. b. Brush the soapy water solution on all gas pipes, joints and fittings. c. Check for bubbling soap. This means you have a leak. Turn "OFF" gas and make the necessary repairs. d. Recheck for leaks. e. Rinse off soapy solution and wipe dry. 2. Is the new temperature-pressure relief valve properly installed and piped to an adequate drain? See "Temperature-Pressure Relief Valve" section. 3. Are the cold and hot water lines connected to the water heater correctly? See "Water Piping" instructions in the "Installing the New Water Heater" section. VENT PIPE TO OUTDOORS 4. Is the water heater completely filled with water? See "Filling the Water Heater" instructions in the "Installing the New Water Heater" section. 5. Will a water leak damage anything? See the "Locating the New Water Heater" section. 6. Is there proper clearance between the water heater and anything that might catch fire? See the "Locating the New Water Heater" section. 7. Do you have adequate ventilation so that the water heater will operate properly? See "Combustion Air and Ventilation" in the "Locating the New Water Heater" section. 8. Is the vent piping properly secured? See "Venting" instructions in the "Installing the New Water Heater" section. 9. Is there proper clearance between the vent pipe and anything that might catch fire? See "Venting" instruc tions in the "Installing the New Water Heater" section. 10. Is the vent pipe properly sloped and does the vent ter minate outdoors? See "Venting" instructions in the "Installing the New Water Heater" section. 11. Do you need to call your gas company to check the gas pipe and its hookup? HOT SHUTOFF VALVE TEE DRIP LEG (Sediment trap) PIPE CAP SHUTOFF VALVE COLD HOT GAS SUPPLY COLD TEMPERATURE-PRESSURE RELIEF VALVE DISCHARGE PIPE (Do not cap or plug) MODEL RATING PLATE SUITABLE FOR WATER (POTABLE) HEATING AND SPACE HEATING AUTOMATIC STORAGE WATER HEATER ELECTRICAL RATING: VOLTS 115/HZ60/AMPS 2 24 Operating This water heater is equipped with an electrically operated venting system and electronic control. For the burner to come on, the water heater thermostat must call for heat. Then the system will begin sequencing, each section prov ing itself before gas is allowed to flow to the burner. BEFORE THE WATER HEATER WILL OPERATE: 1. The control system must be connected to a grounded 110/120 volt power supply. The control system has an overall rating of 2 amps. The water heater must be securely and adequately grounded in accordance with local codes and with the current edition of the National Electrical Code ANSI/NFPA 70. 2. The ON/OFF rocker switch, located on the control box above the thermostat must be in the "ON" position for the electrical control system to operate allowing the gas portion to operate (ignite burner). 3. The venting manual reset switch must be in the closed position. See "Venting Manual Reset Switch" in the "For Your Information" section. 4. There is a non-resettable hi-limit switch in the thermo stat, which must be good (closed) for the thermostat to be operated. See "High Temperature Shut Off System" in the "For Your Information" section. OPERATION When the thermostat calls for heat, gas is allowed to flow to a (N/O) pressure switch closing it. An electrical circuit is then made to the blower, turning it on. When the blower has achieved sufficient venting, the air pressure switch will close. A 120 volt circuit will be completed through the venting manual reset switch and on to the 120 volt gas valve. The 120 volt gas valve will open allowing gas to flow to the burner. The hot surface ignitor will establish a main burner flame. ALL 40 GALLON AND 50 GALLON 40,000 BTU/HR MODELS ONLY BLOWER MOTOR VENTING MANUAL RESET SWITCH DRAFT HOOD 75 GALLON 70,000 AND 75,000 BTU/HR, 50 GALLON 52,500, 55,000 AND 62,500 BTU/HR, AND 40 GALLON 50,000 BTU/HR MODELS ONLY BLOWER MOTOR VENTING MANUAL RESET SWITCH DRAFT HOOD AIR PRESSURE SWITCH ON/OFF SWITCH ALL MODELS DILUTION AIR INTAKE DILUTION AIR INTAKE ON/OFF SWITCH AIR PRESSURE SWITCH 120V GAS VALVE BURNER HOT SURFACE IGNITOR 25 Operating (cont'd) WARNING BEFORE OPERATING [PROPANE (L.P.) GAS WATER HEATERS]: Propane (L.P.) gas is heavier than air. Should there be a leak in the system, the gas will settle near the ground. Basements, crawl spaces, skirted areas under manufactured (mobile) homes (even when ventilated), closets and areas below ground level will serve as pock ets for the accumulation of this gas. Before attempting to operate the water heater or turning a nearby electri cal light switch, be absolutely sure there is no accumu lated gas in the area. Search for odor of gas by sniffing at ground level in the vicinity of the appliance. If odor is detected, follow the steps indicated at "For Your Safety" on the cover page of this manual, then leave the premises. Operating instructions are located on front of the water heater, above or to one side of the gas control valve. See page 27. WARNING AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER. FOR YOUR SAFETY IF YOU SMELL GAS: 1. Do not try to light any appliance. 2. Do not touch any electrical switch; do not use any phone in your building. 3. Immediately call you gas supplier from a neighbor's phone. Follow the gas supplier's instructions. 4. If you cannot reach your gas supplier, call the fire department. CHECK FOR LEAKS Be sure to check all your gas pipes for leaks before operat ing your water heater. Use a soapy water solution, not a match or open flame. Check the factory gas fittings when the main burner is turned "ON". WATER HEATING IGNITION SEQUENCE (Make sure gas and electric power are connected properly) 1. The ignition control module is powered and monitors the system, waiting for a call for heat from the thermostat. 2. The thermostat calls for heat by reading a resistance value within a given range directly proportional to water temperature. 3. The control module: a) Checks the pressure switch for an open circuit. b) Energizes the blower. c) Checks the pressure switch for a closed circuit to prove draft. d) Sends line voltage to the hot surface igniter with a 20-second warm up period. e) Opens the gas valve and checks the sensing rod for flame. 4. The burner heats the water to the desired thermostat setting. a) The resistance in the thermostat rises to the value selected by the temperature control knob. b) The control module closes the gas valve and 5 seconds later, removes power from the blower. 5. Cycle is completed. CONTROL SEQUENCE - HOT SURFACE DIRECT IGNITION Pre-purge 5 sec. HSI Warm-up 20 sec. Ignition Activation Period 4 sec. Flame Recognition Period 1sec. Ignition Trial 4 sec. Interpurge 5 sec. Post-purge 5 sec. Retries 2 Reset from Lockout 1 hr. Flame Sensing (Nominal) HSI Off/Run Mode 4.0 µ DC 26 of life. Operating (cont'd) FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do NOT try to light the burner by hand. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will VACATION • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in the gas control but tons. Never use tools. If the control buttons will not push in, don't try to repair them, call a qualified ser vice technician. Force or attempted repair may settle on the floor. A B C VERY result in a fire or explosion. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. COOLER HOTTER • Do not touch any electric switch; do not use any phone in your building. HOT D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has • Immediately call your gas supplier from a neighbor's WARM-------------- ----------------------- ---------------------- ------------------------------ phone. Follow the gas supplier's instructions. ------------------------------------------------------ * ----------------------------------------------------------------------- * ---------------------------------------------------------- -------------------------------------------------------------------------------------- -------------------------------------------------------------------------------------- been under water. OPERATING INSTRUCTIONS * ------------------------------------------------------------------------ ----------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------ -------------------------------------------------------- 1. STOP! Read the safety information above on this label. 2. Set the ON/OFF switch on the control box to the "ON" position. 3. Set the thermostat to the lowest setting by first press ing the COOLER and HOTTER buttons together and holding for 1 second. Then press the COOLER button until the WARM indicator light appears. 4. Set the ON/OFF switch on the control box to the "OFF" position. 5. This appliance is equipped with a device which auto matically lights the burner. DO NOT TRY TO LIGHT THE BURNER BY HAND. 6. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step. 7. Turn on all electrical power to the appliance. 8. Set the ON/OFF switch on the control box to the "ON" position. 9. Set the thermostat to desired setting by first pressing the COOLER and HOTTER buttons together and holding for 1 second. Then press the HOTTER button . 10. WATER TEMPERATURE ADJUSTMENT is approximately 120˚F. CAUTION: Hotter water increases the risk of scald injury. Consult the instruction manual before changing temperature. 11. If the appliance will not operate, follow the instruc tions "TO TURN OFF GAS TO APPLIANCE" and call your technician or gas supplier. WARNING: TURN OFF ALL ELECTRIC POWER BEFORE SERVICING TO TURN OFF GAS TO APPLIANCE 1. Set thermostat to the lowest setting by first pressing the COOLER and HOTTER buttons together and holding for 1 second. Then press the COOLER button until the WARM indicator light appears. 2. Set the ON/OFF switch on the control box to the "OFF" position. 3. Turn off all electric power to the appliance if service is to be performed. 27 Temperature Regulation Due to the nature of the typical gas water heater, the water temperature in certain situations may vary up to 30°F high er or lower at the point of use such as, bathtubs, showers, sink, etc. Any water heaters intended purpose is to heat water. Hot water is needed for cleaning, (bodies, dishes, clothing). Hot water will present a scald hazard. Depending on the time element, and the people involved (normal adults, children, toddlers, elderly, infirm, etc.) scalding may occur at differ ent temperatures. WARNING HOTTER WATER CAN SCALD: Water heaters are intend ed to produce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be perma nently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally hand icapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, some type of tempering device, such as a mixing valve, should be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores. A qualified plumber should be consulted. Follow manufac turers instructions for installation of the valves. Before changing the factory setting on the thermostat, read the "Temperature Regulation" section in this manual. WARNING Never allow small children to use a hot water tap, or to draw their own bath water. Never leave a child or hand icapped person unattended in a bathtub or shower. The thermostat of this water heater has been factory set at its lowest position, to reduce the risk of scald injury. It is adjustable and must be reset to the desired temperature set ting. The mark ( ▼ ) (on temperature setting of gas valve) indicative of approximately 120°F is preferred starting point. Some states have a requirement for a lower setting. If you need hotter water, follow directions for temperature adjustment, but beware of the warnings in this section. Pressing the "COOLER" ● button decreases temperature ▲ and pressing the "HOTTER" ● button increases the tem ▲ perature. To avoid any unintentional changes in water temperature settings, the control has a tamper resistant feature for changing the temperature setting. To change the tempera ture setting follow these instructions: 1. "Wake Up" the temperature indicators by holding down both "COOLER" and "HOTTER" temperature adjust ment buttons at the same time for one second (See Figure below). One or two of the temperature indicators will light up. These indicators will only remain on for 30 seconds if no further buttons are pressed. After 30 seconds the control will go back to "Sleep" mode. 2. Release both of the temperature adjustment buttons. A. To decrease the temperature press and release the "COOLER" button until the desired setting is reached. b. To increase the temperature press and release the "HOTTER" button until the desired setting is reached. NOTE: Holding down the button will not continue to lower or raise the temperature setting. The button must be pressed and released for each temperature change desired. TEMPERATURE INDICATORS TEMPERATURE ADJUSTMENT BUTTONS Time to Produce Display 2nd & 3rd Degree Temperature Setting ▼ A B C Burns on Adult Skin C - Flashing = approx. 160°F ● ● ● ● ● ● About 1/2 seconds C = approx. 150°F ● ● ● ● ● ● About 1-1/2 seconds B = approx. 140°F ● ● ● ● ● ● Less than 5 seconds A = approx. 130°F ● ● ● ● ● ● About 30 seconds ▼ = approx. 120°F ● ● ● ● ● ● More than 5 minutes WARM = approx. 80°F ● ● ● ● ● ● - - - - - - - - - - - - - - - - NOTE: Water temperature range of 120°–140°F recom mended by most dishwasher manufacturers. WARNING Should overheating occur or the gas supply fail to shut off, turn "OFF" the manual gas control valve to the appliance. 28 For Your Information Start Up Conditions CONDENSATION Whenever the water heater is filled with cold water, a cer tain amount of condensation will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensing. This usually happens when: a. When a new water heater is filled with cold water for the first time. b. When gas burns and water vapor is produced in water heaters, particularly high efficiency models where flue temperatures are lower. c. When you use large amounts of hot water in a short time and the refill water is very cold. Moisture from the products of combustion condenses on the cooler tank surfaces and form drops of water which may fall onto the burner or other hot surfaces and produce a "sizzling" or "frying" noise. Because of the suddenness and amount of water, conden sation water may be diagnosed as a "tank leak". After the water in the tank warms up (about 1-2 hours), the condition should disappear. Do not assume the water heater is leaking until there has been enough time for the water in the tank to warm up. An undersized water heater will cause more condensation. The water heater must be sized properly to meet the fami ly's demands for hot water including dishwashers, wash ing machines and shower heads. Excessive condensation may be noticed during the winter and early spring months when incoming water tempera tures are at their lowest. Good venting is essential for a gas fired water heater to operate properly as well as to carry away products of com bustion and water vapor. SMOKE/ODOR It is not uncommon to experience a small amount of smoke and odor during the initial start-up. This is due to burning off of oil from metal parts, and will disappear in a short while. THERMAL EXPANSION Water supply systems may, because of such events as high line pressure, frequent cut-offs, the effects of water ham mer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc...to control these types of problems. When these devices are not equipped with an internal by-pass, and no other measures are taken, the devices cause the water sys tem to be closed. As water is heated, it expands (thermal expansion) and closed systems do not allow for the expan sion of heated water. 29 The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of the water heaters temperature-pres sure relief valve is reached, the valve will relieve the excess pressure. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This is an unacceptable condition and must be corrected. It is recommended that any devices installed which could create a closed system have a by-pass and/or the system have an expansion tank to relieve the pressure built by ther mal expansion in the water system. Expansion tanks are available for ordering through local plumbing supply hous es. Contact the local water supplier and/or plumbing inspector for assistance in controlling these situations. STRANGE SOUNDS Possible noises due to expansion and contraction of some metal parts during periods of heat-up and cool-down do not represent harmful or dangerous conditions. Condensation causes sizzling and popping with the burn er area during heating and cooling periods and should be considered normal. See "Condensation" in this section. Operational Conditions SMELLY WATER In each water heater there is installed at least one anode rod (see parts section) for corrosion protection of the tank. Certain water conditions will cause a reaction between this rod and the water. The most common complaint associat ed with the anode rod is one of a "rotten egg smell". This odor is derived from hydrogen sulfide gas dissolved in the water. The smell is the result of four factors which must all be present for the odor to develop: a. a concentration of sulfate in the supply water. b. little or no dissolved oxygen in the water. c. a sulfate reducing bacteria within the water heater. (This harmless bacteria is non-toxic to humans.) d. an excess of active hydrogen in the tank. This is caused by the corrosion protective action of the anode. Smelly water may be eliminated or reduced in some water heater models by replacing the anode(s) with one of less active material, and then chlorinating the water heater tank and all hot water lines. Contact the local water heater sup plier for further information concerning an Anode Replacement Kit #9000029 and this Chlorination Treatment. For Your Information (cont'd) SMELLY WATER (cont'd) If the smelly water persists after the anode replacement and chlorination treatment, we can only suggest that continuous chlorination and filtering conditioning equipment be con sidered to eliminate the water problem. Do not remove the anode leaving the tank unprotected. By doing so, all warranty on the water heater tank is voided. "AIR" IN HOT WATER FAUCET'S WARNING HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long peri od of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possibility of injury under these conditions, we recom mend the hot water faucet be opened for several minutes at the kitchen sink before any electrical appliances which are connected to the hot water system are used (such as a dishwasher or washing machine). If hydrogen gas is present, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near the faucet at the time it is open. VENTING MANUAL RESET SWITCH There is a venting manual reset switch located on the draft hood. If the venting manual reset switch is activated, it will not reset itself. Before resetting this venting manual reset switch, check for flue blockage and propriety of the venting system. To reset the venting manual reset switch, press the red reset button. HIGH TEMPERATURE LIMIT SWITCH (Single-Use Type Energy Cut Off) The thermostat has a built-in limit switch which will actu ate in case of excessive water temperatures. The heater can not be relit until the gas control valve is replaced. It is important that a serviceman be called to determine the rea son for limit operation and thus avoid repeated thermostat replacement. Lower the temperature adjustment setting on new control. WARNING Should overheating occur or the gas supply fail to shut off, turn "off" the manual gas control valve to the appliance. NOT ENOUGH OR NO HOT WATER 1. Check the manual gas shut off valve to be sure it is open. 2. The ON/OFF switch on the control box must be "ON". 3. The temperature button adjustment may be set too low. See the "Temperature Regulation" section. 4. The gas company can check the gas input to see if it is correct. An underfired water heater will not heat water as quickly. 5. Look for leaking or open hot water faucet's. Make sure all are closed. 6. The cold water inlet temperature may be colder during the winter months. It will take longer to heat the water and seem like less hot water. 7. If you cannot find what is wrong, call the local gas util- ity and/or plumbing contractor. WATER IS TOO HOT 1. The temperature adjustment setting may be set too high. See the "Temperature Regulation" section. VENTING MANUAL RESET SWITCH BLOWER MOTOR OR DRAFT HOOD VENTING MANUAL RESET SWITCH 30 NOTE: A period of time is necessary after an adjust ment has been made for the water temperature to reach the new temperature setting. 2. If lower temperature settings will not lower the water temperature, call the local gas utility. Periodic Maintenance Venting System Inspection At least once a year a visual inspection should be made of the venting system. You should look for: 1. Obstructions which could cause improper venting. The combustion and ventilation air flow must not be obstructed. 2. Damage or deterioration which could cause improper venting or leakage of combustion products. 3. Rusted flakes around top of water heater. WARNING Be sure the vent piping is properly connected to prevent escape of dangerous flue gasses which could cause deadly asphyxiation. WARNING Obstructions and deteriorated vent systems may present serious health risk or asphyxiation. WARNING Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemi cal vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive. WARNING If after inspection of the vent system you found sooting or deterioration, something is wrong. Call the local gas utility to correct the problem and clean or replace the flue and venting before resuming operation of the water heater. Burner Inspection WARNING Flood damage to a water heater may not be readily visi ble or immediately detectible. However, over a period of time a flooded water heater will create dangerous conditions which can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Contact a qualified service technician or contractor to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced! Check main burner every 12 months for proper flame char acteristics. This is done by removing outer and inner doors on heater. The main burner should provide complete com bustion of gas; ignite rapidly; give reasonably quiet opera tion; cause no excessive flame lifting from burner ports. Make sure that the flow of combustion and ventilation air is not blocked. If proper flame characteristics are not evident, check for accumulation of lint or other foreign material that restricts or blocks the air openings in the heater or burner. Also check Combustion Air and Ventilation requirements. WARNING Soot build-up indicates a problem that requires correc tion before further use. Turn "OFF" gas to water heater and leave "OFF" until repairs are made, because failure to correct the cause of the sooting can result in a fire. Burner Cleaning NOTE: Burner assembly must be handled carefully to avoid damaging the hot surface ignitor. In the event your burner needs cleaning, use the following instructions: If inspection of the burner shows that cleaning is required, turn the ON/OFF rocker switch located on the control box to "OFF" position and allow the burner to cool. Loose deposits on or around the burner can be removed by carefully using the hose of a vacuum cleaner inserted through the access door of the water heater. If the burner needs to be removed for additional cleaning, call the local gas utility or qualified service agent to remove and clean the burner with a soft brush. Clean main burner orifice with a suitable soft material. Correct the problem that required the burner to be cleaned. 31 Periodic Maintenance (cont'd) L.P. Gas Control Valve & Burner Assembly Replacement Information WARNING PROPANE (L.P.) GAS CONTROL VALVE AND BURNER ASSEMBLY REPLACEMENT INFORMATION. For Propane (L.P.) Gas Models Only: Your water heater is equipped with a Propane (L.P.) gas control valve and a main burner assembly with left hand threads for the following fittings and their connections. (1) The connection between the manifold and the gas control valve (A to B) are left hand threads. (2) The connection between the main burner orifice and the manifold (C to D) are left hand threads. For ordering these replacement parts, please refer to the "Repair Parts" section of this manual. A B C D Housekeeping Vacuum around base of water heater for dust, dirt, and lint on a regular basis. WARNING INSTALLED IN SUITABLE AREA: To insure sufficient ventilation and combustion air supply, proper clear ances from the water heater must be maintained. See "Locating the New Water Heater" section. Combustible materials such as clothing, cleaning materials, or flammable liquids, etc. must not be placed against or adjacent to the water heater which can cause a fire. Anode Rod Inspection The anode rod is used to protect the tank from corrosion. Most hot water tanks are equipped with an anode rod. The submerged rod sacrifices itself to protect the tank. Instead of corroding the tank, water ions attack and eat away the anode rod. This does not affect the water's taste or color. The rod must be maintained to keep the tank in operating condition. Anode deterioration depends on water conductivity, not necessarily water condition. A corroded or pitted anode rod indicates high water conductivity and should be checked and/or replaced more often than an anode rod that appears to be intact. Replacement of a depleted anode rod can extend the life of your water heater. Inspection should be conducted by a qualified technician, and at a minimum should be checked annually after the warranty period. Temperature-Pressure Relief Valve Operation The temperature-pressure relief valve must be manually operated at least once a year. TEMPERATURE-PRESSURE RELIEF VALVE DISCHARGE PIPE WARNING When checking the temperature-pressure relief valve operation, make sure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) that the water manually discharged will not cause any property damage because the water may be extremely hot. If after manually operating the valve, it fails to complete ly reset and continues to release water, immediately close the cold water inlet to the water heater, follow the drain ing instructions, and replace the temperature-pressure relief valve with a new one. Failure to install and maintain a new properly listed tem perature-pressure relief valve will release the manufacturer from any claim which might result from excessive tempera ture or pressure. WARNING If the temperature-pressure relief valve on the appliance weeps or discharges periodically, this may be due to thermal expansion. Your water heater may have a check valve installed in the water line or a water meter with a check valve. Consult the water supplier and/or plumbing contractor for further information. Do not plug the tem perature-pressure relief valve. 32 Periodic Maintenance (cont'd) Draining The water heater should be drained if being shut down dur ing freezing temperatures. Also periodic draining and clean ing of sediment from the tank may be necessary. 1. Turn "OFF" gas supply to water heater. 2. CLOSE the cold water inlet valve to the water heater. 3. OPEN a nearby hot water faucet and leave open to allow for draining. 4. Connect a hose to the drain valve and terminate to an adequate drain. 5. OPEN the water heater drain valve to allow for tank draining. NOTE: If the water heater is going to be shut down and drained for an extended period, the drain valve should be left open with hose connected allowing water to ter minate to an adequate drain. 6. Close the drain valve. 7. Follow instructions in the "Filling The Water Heater" section. 8. Follow the lighting instructions in the "Lighting" section to restart the water heater. Drain Valve Washer Replacement NOTE: For replacement, use a 17⁄32″ x 13⁄64″ x 1⁄8″ thick washer available at your nearest hardware store. For ordering replacement washers, refer to the "Repair Parts" section. 1. Turn "OFF" gas supply to water heater. 2. Follow "Draining" instructions. 3. Turning counter clockwise, remove the hex cap below the screw handle. 4. Remove the washer and put the new one in place. 5. Screw the handle and cap assembly back into the drain valve and retighten using a wrench. DO NOT OVER TIGHTEN. 6. Follow instructions in the "Filling The Water Heater" section. 7. Check for leaks. 8. Follow the lighting instructions in the "Lighting" section to restart the water heater. HANDLE AND CAP ASSEMBLY WASHER Service If a condition persists or you are uncertain about the oper ation of the water heater, let a qualified person check it out. Call the local utility and/or plumbing contractor. 33 Leakage Checkpoints Use this guide to check a "Leaking" water heater. Many sus pected "Leakers" are not leaking tanks. Often the source of the water can be found and corrected. If you are not thoroughly familiar with gas codes your water heater, and safety practices, contact the gas utility to check the water heater. A CAUTION Read this manual first. Then before checking the water heater make sure the gas supply has been turned "OFF", and never turn the gas "ON" before the tank is com pletely full of water. CAUTION Never use this water heater unless it is completely filled with water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning "ON" gas to the water heater. C B H G I B F E D Water at the vent pipe is water vapor which has con densed out of the combustion products. This is A caused by a problem in the vent. Contact the gas utility. * Condensation may be seen on pipes in humid B weather or pipe connections may be leaking. * The primary anode rod fitting may be leaking. C Small amounts of water from temperature-pressure D relief valve may be due to thermal expansion or high water pressure in your area. * The temperature-pressure relief valve may be leak ing at the tank fitting. E Water from a drain valve may be due to the valve F opened slightly. * The drain valve may be leaking at the tank fitting. G Combustion products contain water vapor which H can condense on the cooler surfaces of the tank. Droplets form and drip into the fire or run on the floor. This is common at the time of startup after installation and when incoming water is cold. Water in the water heater bottom or on the floor may I be from condensation, loose connections, or the relief valve. DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken. Leakage from other appliances, water lines, or ground seepage should also be checked. * To check where threaded portion enters tank, insert cotton swab between jacket opening and fitting. If cotton is wet, follow "Draining" instructions in the "Periodic Maintenance" section and then remove fitting. Put pipe dope or teflon tape on the threads and replace. Then follow "Filling the Water Heater" instructions in the "Installing the New Water Heater" section. 34 Troubleshooting WARNING This troubleshooting guide has been supplied for use by qualified service personnel who have a complete under standing of both electricity and gas. WARNING Label all wiring before disconnecting any wiring; to ensure correct reconnection. Failure to follow this instruction could cause improper and possible danger ous operation, resulting in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. THERMOSTAT AND GAS SUPPLY CHECK No Yes Is gas being supplied to the thermostat? Turn "ON" gas supply. Is thermostat calling for heat? Run (hot) water from heater and set adjustment button higher. Check using a manometer at thermostat pressure tap. Yes Is there a minimum gas pressure 4″ W.C. for natural gas or 10″ W.C. for propane (L.P.) gas? Call gas company to increase No gas pressure. Yes GO TO SYSTEMS CHECK SECTION, PAGE 36 35 Troubleshooting (cont'd) SYSTEMS CHECK Please check guidelines below. For your safety, water heater service should be performed only by a qualified service technician. WARNING DO NOT BY-PASS ANY CONTROLS TO MAKE HEATER OPERATE. OPERATE ONLY AS WIRED FROM FACTORY. LED STATUS PROBLEM SOLUTION An open earth ground circuit to the 1. Check that the earth ground connection is ▼ ABC ● ● ● ● ● ● ▼ ABC ● ● ● ● ● ● ▼ ABC ● ● ● ● ● ● ▼ ABC ● ● ● ● ● ● ▼ ABC ● ● ● ● ● ● ▼ ABC ● ● ● ● ● ● ▼ ABC ● ● ● ● ● ● ▼ ABC ● ● ●●● ● ▼ ABC ●●●●●● ▼ ABC ● ● ● ● ● ● ▼ ABC ● ● ● ●●● ▼ ABC ● ● ● ● ● ● ▼ ABC ● ● ● ● ● ● ignition system. properly connected. 2. Check that the ground conductor on the water heater is properly connected. Wiring error or a high resistance to 1. Check for proper connection of line neutral earth ground. and hot wires. 2. Check that the water heater is securely connected to earth ground. Pressure switch remained closed longer 1. Pressure switch wiring is incorrect. than 5 seconds after the call for heat 2. Replace pressure switch. began. Pressure switch remained opened longer 1. Pressure switch wiring is incorrect. than 5 seconds after the combustion 2. Pressure switch tubing not connected blower was energized. correctly. 3. Air intake or exhaust obstructed. Error in the hot surface ignitor circuit. 1. Check that all wiring is correct and secure. 2. Replace hot surface ignitor. System in lockout. 1. Gas supply is off or too low to operate. 2. Hot surface ignitor not positioned correctly. 3. Low voltage to the water heater. 4. Electric polarity to unit is incorrect - test and correct. Problem in the gas valve driver circuit. 1. Turn power to the water heater off for 10 seconds and then back on. 2. Replace gas control valve. Problem with the internal circuit. 1. Turn power to the water heater off for 10 seconds and then back on. 2. Replace gas control valve. Problem with the internal circuit. 1. Turn power to the water heater off for 10 seconds and then back on. 2. Replace gas control valve. Flame signal sensed out of proper 1. Replace gas control valve. sequence. ECO activated. 1. Replace gas control valve. One of the temperature adjust buttons 1. Press and release each of the buttons once. stuck closed. 2. Replace gas control valve. Water temperature sensor is either 1. Check that all wiring is correct and secure. open or short circuited. 2. Replace gas control valve. 36 Troubleshooting (cont'd) PROBLEM CAUSE SOLUTION Blower will not run. A) "ON/OFF" control switch turned off. Turn switch to the "ON" position. B) Blower unplugged. Plug blower back into 115 VAC. outlet. C) No power at outlet. Repair service to outlet. D) Thermostat defective. Replace thermostat. E) Control harness defective. Replace control harness. F) High limit control circuit open. Replace ECO. NOT ENOUGH G) Blower motor defective. Replace Blower Assembly. HOT WATER Thermostat problems. A) Thermostat set too low. Set temperature control higher. B) Thermostat or ECO defective. Replace thermostat or ECO as required. Others A) Heater undersized. Reduce hot water use. B) Low gas pressure. Contact dealer. C) Incoming water is unusually cold. Allow more time for heater to reheat. D) Leaking hot water pipes or fixtures. Have plumber check and repair leaks. A) Not enough dilution air to mix with Proper dilution air must be provided for dilution flue gases. of flue temp. Refer to "INSTALLING THE NEW VENT PIPE TOO HOT WATER HEATER" section. (ABOVE 170˚F) B) Dilution air too hot for mixing with Check for heat sources around and/or blockage flue gases. of dilution air intake at draft hood. (See page 25). C) Wrong burner orifice. Install correct orifice. A) Dirt in burner ports Turn off heater and gas, clean burner head. B) Combustion air path restricted. Check dilution air intake exhaust venting, and YELLOW FLAME air openings in bottom base pan for obstructions or blockage. C) Not enough dilution air for proper Check dilution air intake for obstructions or combustion. blockage. A) Water on the floor under heater. See "CONDENSATION" section. CONDENSATION B) Water dripping from blower assembly. Provide drip "TEE" to catch condensation from horizontal section of exhaust vent close to blower assembly. Improperly sealed, hot or cold supply Tighten threaded connections. connections, relief valve, drain valve WATER LEAKS or thermostat threads. Leakage from other appliances or water Inspect other appliances near water heater. lines. Condensation of flue products. See "CONDENSATION" section. Thermal expansion in closed water Install thermal expansion tank (DO NOT plug LEAKING T&P system. T&P valve). Improperly seated valve. Check relief valve for proper operation (DO NOT plug T&P valve). HOT WATER ODORS High sulfate or mineral content in Drain and flush heater thoroughly then refill. (Refer to SMELLY WATER) water supply. Bacteria in water supply. Chlorinate water supply. WATER TOO HOT Thermostat set too high. Refer to TEMPERATURE REGULATION. WATER HEATER SOUNDS Condensation dripping on burner. See "CONDENSATION" section. SIZZLING-RUMBLING Sediment at bottom of heater tank. Clean sediment from tank. Refer to DRAINING instruction in Maintenance section of manual. SOOTING Improper combustion. Refer to COMBUSTION AIR AND VENTILATION on pages 9, 10 and 11. HEATER LIGHTS BUT Outlet polarity is reversed. Test polarity and correct. GOES OUT IN 4-5 SECONDS 37 Repair Parts 1 2 3 4 5 6 7 PVC, ABS or CPVC items for all models supplied locally 25 24 26 23 28 27 20 8 12 14 13 15 17 OR 9 8 9 10 11 21 29 Blower/Draft Hood Assembly for 40,000 Btu/Hr Models Only 22 or 19 18 16 30 38 Repair Parts (cont'd) KEY PART NO. DESCRIPTION 1. Vent Cap w/Screen (PVC) 2. Wall Collar 3. PVC, ABS or CPVC Schedule 40 Vent Pipe (supplied locally) 4. 90° PVC, ABS or CPVC Schedule 40 Elbow (supplied locally) 5. Vent/Blower Adapter 6. Blower 7. Blower Gasket 8. Venting Manual Reset Switch 9. Draft Hood Assembly 10. Dip Tube 11. Anode Rod 12. Temperature-Pressure Relief Valve 13. Drain Valve 14. Drain Valve Washer (17/32″ x 13/64″ x 1/8″ thick) 15. Inner Door 16. Hot Surface Ignition Assembly 17. Burner Assembly (Natural) 17. Burner Assembly (L.P.) 18. Orifice (Natural) 18. Orifice (L.P.) KEY PART NO. DESCRIPTION 19. Manifold (Natural) 19. Manifold (L.P.) 20. Gas Thermostat (Natural) 20. Gas Thermostat (L.P.) 21. Wiring Harness 22. Manifold Cover 23. Control Cover 24. On/Off Switch 25. Pressure Switch 26. Power Cord 27. Flue Baffle 28. Restrictor Ring 29. Drain Pan 30. Water Heater Stand Now that you have purchased this Water Heater, should a need ever exist for repair parts or service, simply contact the com pany it was purchased from or the manufacturer listed on the model rating plate on the water heater. Be sure to provide all pertinent facts when you call or visit. Selling prices will be furnished on request or parts will be shipped at prevailing price and you will be billed accordingly. The model number of your Gas Water Heater will be found on the model rating plate located above the gas control valve. WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: MODEL NUMBER (TYPE GAS) NATURAL OR PROPANE (L.P.) SERIAL NUMBER PART DESCRIPTION THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST. 39

Không có nhận xét nào:

Đăng nhận xét

Black & Decker Black&Decker Vacuum NV4820CN, homeappliance

Download! NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NW3620N NW4820N ACE 2 BDF 3 GHI 4 ENGLISH (Original instructions) Int...